Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains And Allied Works I, dewas-Madhya Pradesh

Public Health Engineering Department-PHED has published Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains And Allied Works I. Submission Date for this Tender is 04-03-2023. Machine Tools Tenders in dewas Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36505527
Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains And Allied Works I
Open Tender
Indian
Madhya Pradesh
dewas
04-03-2023

Tender Details

Operation And Maintenance Of 4.54 Mld Capacity Bank Note Press Water Supply Scheme In Block And District Shajapur & Dewas Comprising Of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains And Allied Works Including All Required Materials, Consumables, Chemicals, All Labour Etc Complete ( Excluding Raw Water & Energy Charges ) Required For Successful Operation Of The Scheme For Three Years

Key Value

Document Fees
INR 15000 /-
EMD
INR 253852.0 /-
Tender Value
INR 2.53 Crore /-

BOQ Items

Name of Work:- Operation and Maintenance of 4.54 MLD capacity Bank Note Press Water Supply Scheme in Block and District Shajapur & Dewas comprising of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains and allied works including all required materials, consumables, chemicals, all labour etc complete (excluding raw water & energy charges) required for successful operation of the scheme for three years.
Sl. No. Item Description
1Operation and Maintenance of 4.54 MLD capacity Bank Note Press Water Supply Scheme in Block and District Shajapur & Dewas comprising of Raw Water & Clear Water Pumping Stations, Water Treatment Plant, Electric Sub Station, Pumping Mains and allied works including all required materials, consumables, chemicals, all labour etc complete (excluding raw water & energy charges) required for successful operation of the scheme for three years.
2Operation& routinemaintenance of raw water pumping station including required T & P, staff, consumable items like oil, grease, gland etc with Charges for commercial vehicle for operation and maintenance of whole scheme .
3Operation & routinemaintenance of Water treatment plant and Clear water pump including required T & P staff, consumable item like oil, grease, chemical/Glassware etc for water purification and water testing complete.
4Operation& routinemaintenance of clear water pumping station including required T & P, staff, consumable items like oil, grease, gland etcfor operation and maintenance of whole scheme .
5Operation and routinemaintenance of raw/clear water pumping main includingall labour ,required T&P and etc complete.
6Repairing and rewinding of raw water motor i/c dismantling, repairing and reinstallation with cost of all material and all labour complete
7Repairing and rewinding ofclear water motor i/c dismantling, repairing and reinstallation with cost of all material and all labour complete
8Opening overhauling of oil chamber of 120 HP raw water centrifugal motor pump of intake at lakhunder and filling fresh oil of Servo, Castrol or equivalent make as per direction of Engineer in Charge including cost of oil , all labour etc complete.
9Opening overhauling of gear boxes ofWTP and filling fresh oil of Servo, Castrol or equivalent make as per direction of Engineer in Charge including cost of oil , all labour etc complete.
10Job work for repairing of panel board,Air Compressor,blower, agitator/ motor for alum tank,gates, chlorinator /chlorine supply system ,bridge & otherE/M miscelleneous item etcof WTP in a year
11Provision for repairing of electrical accessories, fixtures,bulbs, tubelights , helogen lamps,CFL ,LED lights as per requirements at Intake , WTP, Administrative bulildings etc complete including cost of all material, labour etc complete.
12Replacement of gland of 120 HP Raw water centrifugal motor pumps at lakhunder Intake of both ends DE & NDE including all material, labour, testing and commissioning etc complete . 2 pumps x 12 months = 24 Job per year
13Replacement of gland of 12.5 HP Clear water centrifugal motor pumps at WTP of both ends DE & NDE including all material, labour, testing and commissioning etc complete.2 pumps x 12 months = 24 Jobs per year
14Replacement of gland of 5 HP Wash water centrifugal motor pumps at WTPof both ends DE & NDE including all material, labour, testing and commissioning etc complete.2 pumps x 12 months = 24 Jobs per year
15Supplying and fitting of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB with Breaking Capacity 35 KA at 415 V, Current Rating -63-100 Amps & Adjustable: 80% -100% thermal
16Supplying and fitting of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB with Breaking Capacity 35 KA at 415 V, Current Rating -160 Amps & Adjustable: 80% -100% thermal
17Supplying and fitting of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB with Breaking Capacity 35 KA at 415 V, Current Rating -200 Amps & Adjustable: 80% -100%thermal
18Supplying and fitting of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828, MCCB with Breaking Capacity 35 KA at 415 V, Current Rating -400 Amps & Adjustable: 80% -100%thermal
19Supplying and fitting of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP), 0.5 Amp to 5 Amp Rating
20Supplying and fitting of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP), For 40 Amps. Rating only.
21Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification - Digital Ampere Meter with CTs with selector switch per set 1950
22Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification -Digital Volt Meter with selector switch & HRC fuse per set 2100
23Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification -Copper Bus bar strips with PVC sleeves Kg 650
24Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification -Aluminium bus bar strips with PVC sleeves
25Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per pececification -LED lamp indicator each 20049
26Providing and fixingon off switch.
27Providing and fixing single phase preventor.
28Providing and fixing new timer.
29Providing and erection of non linear resister polymertype lightning arrester for 33 KV overhead lines/ sub station with anomonal discharge current rating and complete with galvanised clamping arrangement G.I. bolt nuts as required . complete with all labour materialand all taxes with transportatioin up to site at raw water sub station Lakhunder dam site .
30Providing and filling EHV GR-II Transformer Oil
31Filtration of Oil
32Providing & Fixing 33 KV D.O Post Insulator
33Providing & Fixing 33 KV A.B. Post Insulator
34Providing and fitting 33 KV D.O. Fuse
35Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed. All kind of soil
36Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed. All kind of soil - In muddy area
37Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed. Soft rock with or without blasting or bituminous pavement / cement concrete road.In ordinary or Soft rock with or without blasting or bituminous pavement / cement concrete road.
38Pumping out water caused by springs, tides or river seepage, broken water mains or drains or the like
39Filling available excavated earth in trenches, lead up to 50m and lift up to 1.5m in all kind of soil excluding watering and ramming.
40Providing & laying mechanically mixed cement concrete 20mm nominal size graded crushed stone excluding cost of centering & shuttering.1:11/2:3 (M-20 )
41Providing & laying mechanically mixed R.C.C. excluding centering & shuttering and reinforcement in foundation/plinth (20mm graded metal)
42Providing and placing in position cold twisted steel and hot rolled deformed steel reinforcement for R.C.C. work i/c cutting, bending, binding etc. complete i/c cost of binding wire and wastage.
43Providing & fixing form work i/c centering and shuttering including strutting, propping etc. and removal of form work for:Foundation , footing, bases of columns ,etc for mass concrete
44Providing & fixing form work i/c centering and shuttering including strutting, propping etc. and removal of form work for:Columns, pillars, piers, Abutments, posts and Struts
45Fabrication of M.S. pipes & specials as per relevant IS specifications inclusive of cost of all materials taxes and duties inspection charges, transit insurance, loading/unloading FOR site and stacking etc. complete as for direction of Engineer-in-Charge Fabricating pipes and specials from Steel plates (all thickness as per design) including Labour only for laying of MS pipe and specials as per approved specification complete as directed by Engineer incharge
46Providing and Laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen and internal cement mortar lining. 300 mm dia
47Providing and Laying Ductile Iron any type of specials having dimension as per relevant tableof IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 300 mm dia
48Providing Rubber ISI marked Gasket (push on) joint as per IS-5382/85 to following DI pipes class K-7 and K-9 including testing of joints and cost of jointing materials (Rubber Gasket and soap solution etc.) 300 mm dia
49Labour charges for repairing of 80 to 300 mm dia Sluice/NR valves including cost of required materials and all labour complete.
50Labour Charges for repairing of any type and any size of air valves including cost of required materials and all labour complete.
51Supply and providing lead of best quality for repairing of pipe lines.
52Supply and providing rubber gaskets suitable for 300 mm dia DI pipes of best quality for repairing of pipe lines.
53Providing and supplying of 100kg capacity filled chlorine cylinder at BNP water treatment plant Dewas i/c loading unloading transportation with hydraulic testing report and BIS cirtyficate complete.
54Lalour only for installation of induction or submersible motor pump set with fitting of suction and delavery pipesfitting of foot valve etc. i/c transportation of above material from intaketo site of work with loading and unloading complete.
55Labour charges for electrician cum pump operator for operation of the motor pump at up stream side of dam. 300 daysx 3 shift = 900 mandays per year
56Labour charges forwatch man for safety of pipe line ,motor pump eletric cable etc.300 daysx 3 shift = 900 mandays per year
57Providing and fitting of bearing of standard make in raw water 120 H.P. electric moter i/c dismantling, opening and fitting of new bearing and reinstallation work include cost of all material and labour complete.bearing No6314/C-3
58Providing and fitting of bearing of standard make in raw water 120 H.P. electric moter i/c dismantling, opening and fitting of new bearing and reinstallation work include cost of all material and labour complete.bearing No316ECJ/C3
59Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete 80 mm dia.PN 1.0
60Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete 80 mm dia.PN 1.6
61Report of examination of pressel vessels in form No. 9 ,prescribed under rule 67 of m p factory rule 1962by comptent authority. Air Receiver
62Report of examination of pressel vessels in form No. 9 ,prescribed under rule 67 of m p factory rule 1962by comptent authority. Chlorine pipe line.
63Report of examination of lifting machine,chaine,rope,lifting ackles under sub section (a) iii of section 29 of m p factory rule 1962by comptent authority.
64Charges for hydraulic testing of 100 kg capacity empty chlorine cylinder and providing test report in standard form as per department of health and safety i/c loading unloading transportation complete.
65providing and fitting of Gravityfeed chlorinator as per specification i/c transportation to site ,installation testing, commisning and making connection with existing pipe system complete with all labour ,material etc complete.
66Providing and fitting of connecting terminal plate of 120 HP electric moter i/c removing of burnt plate and fitting of new plate with all labour and material complete with testing .
67Repairing and rewinding of ATS transformer of control pannel of 120 HP electric moter pump set work include dismantling and reinstallation after rewinding complete with all material and labour.
68Re filling offireExtinquisher. ABC type,capacity 5kg
69Re filling offireExtinquisher. BC type,capacity 5kg
70Re filling offireExtinquisher. ABC type,capacity 1 kg
71Providing & fitting of ABC type 5 kg capacity complete filled fire Extinquisher
72Providing and fitting of 150 mm dia.cast iron flanged footvalve for clear water pumps.
73Charges for jointing of 25/35 sq.mm armod cable including detaction of fault, cutting jointing and testing work with all labour and material charges complete.
74Leakage repairing work of 160 mm dia. HDPE pipe line with all required labour, material and machinery including testing of work.
75Labour only for laying and jointing of electric armod power cable of 25/35 sq. mmfrom LBC to motor pump set with required all labour and required lunks and nut bolts etc.
76Providing and fitting of100 m.m. dia. Flexible heavypvc pipefor connection between HDPE pipe and submerssible moter pump set at U/S of lakhunder dam.
77Lalour only for dismantlingof induction or submersible motor pump set with fitting of suction and delavery pipes,fitting of foot valve etc. i/c transportation of above material from site of work to intake with loading and unloading complete.
78Removing and folding of armod cable and stacking properly at intake storei/c all labour,transportation ,loading unloading etc .complete.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail