Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur, jaipur-Rajasthan

Public Works Department-PWD has published Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur. Submission Date for this Tender is 08-03-2023. Coats and Jackets Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36505422
Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur
Open Tender
Indian
Rajasthan
jaipur
08-03-2023

Tender Details

Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur -Supplying, Installation, Testing & Commissioning Ofelectrical Driven Fire Fighting Duty Terrace Pump As Per Tac Andis 12469-1988., Factory Assembledin Pump Make Oemsuitable For Automatic Operation And Consisting Of Following Details Given Asa, B, C, D, E, F, G And H. 2 ( A ) Horizontal End Suction Centrifugal Back Pull Type Pump Complete For Delivery Of Below Mentioned Discharge And Head 3 ( B ) Material Of Construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - Ss 410, Packing - Mechanical Seal 4 ( C ) Squirrel Cage Induction Motor ( Ie-3 Class ) Suitable For 3 Phase, 415 V, 50 Hz, Ac Supply , Class -F Insulation, Synchronous Speed Not Exceeding 3000 Rpm, T.E.F.C Confirming To Ip:55 , Of Required Hp Suitable For The Above Pump , Along With Flexible ( Love Joy Type ) Coupling , Coupling Guard Complete In All Respect . 5 ( D ) Common Bed Plate Fabricated Frommild Steel Channel For Installation Of Pump And Motor Including Anti Vibration Pads. 6 ( E ) The Hydrostatic Tests ( 2 Times Of Design Operating Head Or 1.5 Times The Shut Off Head Whichever Is Higher ) And Performance Tests ( To Determine Developed Head, Pump Bhp And Efficiency V / S Flow ) Of Pumps Along With Trip Test Shall Be Carried Out At Manufacturer’S Works In Virtual / Physical Presence Of Department’S Representatives. 7 ( F ) Physical & Chemical Test Reports Of I ) Pump Casing ( Ii ) Impeller ( Iii ) Shaft ( Iv ) Shaft Sleeveand Dynamic Balance Certificate Is To Be Submitted By Oem 8 ( G ) Suitable Size Reinforced Cementconcreat ( M-30 ) Foundation With Foundation Bolt, Nozing Angle Of Size 40Mm X40mm X5 Mm ( Cost Of Rcc Foundation To Be Paid Extra ) 9 ( H ) Weather Proof Hood Fabricated From 5Mm Thick Uv Stablised Frp Sheet Supported By 50 Mm X 50 Mm X 5 Mm Angle Iron Fram Above Pumpset To Protect It From Weather All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 10 900 Lpm With 35 Mtr Head 11 Providing, Fixing, Jointing, Testing & Commissioning Of Heavy Duty Ms C Class ( Heavy ) Pipes Conforming To Is 3589 / 1239 Part-I For Hydrant And Sprinkler Applicationsincluding Cutting, Screwing, Welding Etc. & Forged Steel Fittings Like Elbows, Tees, Tapers, Reducer, Gaskets Etc. Fixing The Pipe On The Wall / Ceiling With Suitable Clamps, Hanger And Nuts Bolts Including Cutting Hole And Chase In Brick Or Rcc Walls / Slab And Making Good The Same. Complete With Painting Of One Coats Of Red Oxide And Two Or More Coats Of Synthetic Enamel Paint Of Requiredshade Complete As Required. ( Pipe To Be Tested @ 10Kgf / Sqcm For 2 Hrs. ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 12 25 Mm Dia 13 32 Mm Dia 14 40Mm Dia 15 50Mm Dia 16 80 Mm Dia 17 100 Mm Dia 18 Supplying And Fixing Of Pn 16 Flanged Y Strainer Fabricated Out Of Cast Iron Body, Ss 304 Strainer With Perforated Screen With 3 Mm. Dia Holesin Existing Ms / Gi Pipe Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 19 100 Mm Dia 20 Supplying And Fixing Of Pn 16 Cast Iron Dual Plate Wafer Type Check Valve / Non Return Valve With Ss / Bronze Flap Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 21 100 Mm Dia 22 Supplying And Fixing Of Pn 1.6Butterfly Valve ( Wafer Type ) With S.G Iron Disc And Confirming To Is:13095 Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 23 100Mmdia 24 Supplying And Fixing Of Pn 16 Brass / Gm Ball Valves With Screwed End, Ss Ball Including Teflon Tape Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 25 25 Mm Dia. 26 Supplying And Fixing Of Ss 304 Single / Double Headed Oblique Pattern Hydrant Landing Valve ( Internal / External ) With 75 / 100 Mm Dia Flanged Inlet & 63 Mm Dia Instantaneous Type Female Outlet Coupling With Cast Iron Wheel Complete With Abs Cap And Chain And All Accessories As Per Is:5290-93 ( Type-A ) In Cluding Matching Flange ( 14 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 27 Single Headed With 75 Mm Dia. Flanged Inlet 28 Supplying & Fixing Ss-304 Short Branch Pipeconforming To Is: 903:93 Fitted With 20Mm ( Nominal Internal Diameter ) Bore Nozzle, For Projecting Water In Form Of Solid Jet. The Branch Shall Have 63Mm Male Instantaneous Inlet, Suitable For Use With 63 Mm Size Fire Fighting Hoses. H.P. Tested To 21 Kgf / Cm² For 2.5 Minutes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 29 Supplying And Fixing Of Flexible Hose Made With 100% Polyester, Black Epdm Internal Rubber Lining With External Coat Of Synthetic Elastomer ( Is:636, Type-A ) 63 Mm Dia, 15 Mtr. Long Rrl Hose Pipe With Instanteneous Type 63 Mm Dia Ss-304Male And Female Couplings ( Is:903 ) Duly Bound And Riveted To Hose Pipes With Copper Rivets And Ss Wire Etc. As Required.Appropriate Test Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. 30 Supplying And Fixing First -Aid Fire Hose Reel Drum Wall Mounted Swinging Type With Ms Construction Powder Painted In Post Office Red, Conforming To Is 884-1985 With Upto Date Amendments, Complete With The Following As Required. ( A ) Thermoplastic / Rubber Hose ( B ) 20 Mmdia Ul, Fm Bronze / Ss Nozzle With 5Mm Orifice ( C ) Drum And Brackets For Fixing The Equipments On Wall. ( D ) Connections From Riser With 20 / 25 Mm Dia Brass / Gm Gate Valves With Screwed End And Conforming To Is:778 Class-1Through Forged Steel Screwed Union & M.S. Pipe. Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 31 With 30 M X 20 Mm Thermoplastic Hose As Per Is:12585 Type-2 And Bursting Pressure 42 Kg / Sqcm 32 Providing & Fixing Stainless Steel Pressure Gauge With Dial Of 150 Mm Dia Size And Range 0 To 20 Kg / Sq.Cmwith 3 / 8 Bsp Bottom Entry , Ball Valve , Ss Syphon Tube All Fittings Etc, Dulycalibrated Before Installation In Mks And Fps Units, Accuracy Level + / - 1% Including Making Drilling In Existing Ms Pipeetc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 33 Sitc Of Ul 10Th Edition / En54 / Vds Certified Microprocessor Based Inteligent, Analogue Addressable, Modular, Expandable Networkableloop Fire Alarm Control Panel With Each Loop Capacity Of Min 125 Detectors Per Loop With Total Of 125 Detectors & Devices With Loop Length Up To 1 Km As Per Nfpa 72 Approval. The Panel Shall Be Able To Give Pin Point Location Of Addressable Units Via The Address Code For Each Unit. The Panel Shall Also Be Able To Automatically Switch Off All Control Switches When-Ever Any Alarm Is Triggered. . The Panel Shall Have 230 + 5 % Volts Power Supply, Automatic Battery Charger 24V, Sealed Lead Acid Maintanence Free Battries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During Emergency Condtion. Loop Interface Cards, Communication Module, Lcd / Led Unit To Indicate Fire / Fault Signal Of Individual Unit, Inbuilt Networking Port ( Both Rs485&Ethernet ) , Serial Port For Printer, Two Supervisory Inputs, Two Position Key Switch And Usb Port For Programming.Including The Cost Of All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 34 1 - Loop Panel 35 Sitc Of Pressure Switches Ofpressure Range 3 To 15 Bar For Main, Jockey, Terrace Pumpanddiesel Pumps, Etc. As Required ( Control Cable From Pressure Switch To Panel To Be Paid Extra ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 36 Supplying And Fixing Of 750 Mm X 600 Mm X 250 Mm Outdoor Application Fire Hose Cabinet Made Of 1.6 Mm Thick Ms Sheetduly Powder Coated In Red Color Externally And White Internally With 6 Mm Thick Glazeddoors With Expanded Metal 2 Mm Thick Jali Including Necessary Locking Arrangement Suitable To Accommodate 2 Nos 15 Mtr. Long Rrl Hose And 1 No. Branch Pipe On Existing Wall / Angle Iron Frame As Required. ( Cost Of Ms Structure For Mounting Frame Is To Be Paid Extra ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 37 Providing And Fixing Of 15 Mm Dia Bronze Quartzoid Bulb Type Sprinkler Headswith Maximum Working Pressure 11.6 Kg / Sqcm And Suitable For 68 Degree Centigrade Rating Standard Response ( Ul Listed ) Chrome Plated Complete In All Respect Of The Following Type. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 38 Pendant / Upright Type 39 Sitc Of Ul 10Th Edition / En54 / Vds Certifiedautomatic Floating Sensitivity Type Analog Addressable Multi Criteria ( Two Optical / Smoke Sensor To Reduce False Alarm ) Detector With Mounting Base & Led Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 40 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addessable Manual Call Point ( Mcp ) With Led / Fire Indication Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 41 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addressable Sounder With Strobe Light, Loop Powered / Direct Powered From Facp With Sound Level 90 Db And Programmablefrom The Panel Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 42 Supplying And Fixing Inlet Breeching Connection Of Ci Body With Gun Metal Male Instantaneous Inlet Couplings With Inbuilt Nrv, Drainage Connection With 50 Mm Brass Gate Valvecomplete With Pvc Blank Cap And Chain As Required For 150Mm Dia Outlet With 1 No. Matching Flange ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Ways. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 43 2 Way 44 Supplying And Drawing Fire Resistant Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation ( Shielded ) Cables Voltage Grade 300 / 500 V As Per Bs / En 50288-7 In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 45 2 X 1.5 Sq.Mm Armoured With Outer Sheath In Red Color 46 Supply & Fixing Of Co2 Type Fire Extinguisher Conforming To Is:15683:2018, Charged With Co2 Gas ( Purity 99.7% Conforming To Is 15222 ) , Powder Coated Internal & External Surface Manganese Steel Isi Marked As Per Is 7285 Cylinder Body , Wheel Type Forged Brass Release Valve Isi Marked As Per Is 3224 With Inbuilt Safety Release Device ( ( Fusible Plug And Rupture Disc Type ) , 1.0 Mtr. Metal Wire Braided Hose Having Minimum Bursting Pressure Of 140 Kgf / Cm2, Horn With Metallic Thread Connection, Qr Code For Product Traceability, Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 47 Capacity 4.5 Kg. 48 Supply & Fixing Of Dry Powder Agent ( As Per Is 4308:2019 ) , Abc Typefire Extinguisher ( Stored Pressure Type ) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 49 4 Kg 50 Supply & Fabrication Steel Structure With Ms Channel / Angle / Joist / Ismb / Sheet Etc. Including Welding, Rivetting, Cutting, Nut & Bolt , One Coat Of Primer & Two Coat Of Enamel Paint Etc. As Requiredcomplete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 51 S&F Following Sizes ( Dia. ) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along Withisi Marked ( Is:14768 P-Ii 2003 ) Accessories Inrecessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Includingcutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 52 25 Mm 53 Supply & Fixing Of Ceiling Mounted Ul Listed Clean Agent ( Hfc-236Fa ) , Modular Typefire Extinguisher , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Fixed Bulb With Temerature 68 Deg C, Qr Code For Product Traceability Including Fixing On Ceiling With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 54 5 Kg Capacity

Key Value

Document Fees
INR 500 /-
EMD
INR 33460.0 /-
Tender Value
INR 16.73 Lakhs /-

BOQ Items

Name of Work: SITC of Fire detection and Fire Fighting System Work in Simulator Block and Firing rang for NCC Campus JLN Marg Jaipur
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.
2(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head
3(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal
4(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .
5(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.
6(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.
7(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM
8(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )
9(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
10900 LPM with 35 mtr head
11Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS "C " class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
1225 mm dia
1332 mm dia
1440mm dia
1550mm dia
1680 mm dia
17100 mm dia
18Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holesin existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick),nuts, bolts, washers, gaskets etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
19100 mm dia
20Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
21100 mm dia
22Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
23100mmdia
24Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
2525 mm dia.
26Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
27Single Headed with 75 mm Dia. Flanged Inlet
28Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
29Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.
30Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
31With 30 m x 20 mm Thermoplastic hose as per IS:12585 Type-2 and Bursting pressure 42 Kg/sqcm
32Providing & fixing Stainless Steel pressure gauge with dial of 150 mm dia size and range 0 to 20 kg/sq.cmwith 3 / 8 " BSP bottom entry , Ball valve , SS Syphon tube all fittings etc, dulycalibrated before installation in MKS and FPS units, Accuracy Level +/- 1% including Making Drilling in Existing MS PipeEtc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
33SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkableloop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module,LCD/LED unit to indicate Fire / Fault Signal of individual unit,inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
341 - Loop Panel
35SITC of pressure switches ofpressure range 3 to 15 Bar for Main, Jockey, Terrace pumpandDiesel pumps, Etc. as Required ( Control Cable from Pressure switch to Panel to be Paid Extra ). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
36Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
37Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler headswith Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
38Pendant/ Upright type
39SITC of UL 10th edition / EN54 / VDS certifiedAutomatic Floating Sensitivity type Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm) detector with mounting base & LED etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
40SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
41SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
42Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
432 Way
44Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
452 x 1.5 Sq.mm Armoured With Outer Sheath in Red Color
46Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
47Capacity 4.5 Kg.
48Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
494 kg
50Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
51S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
5225 mm
53Supply & Fixing of Ceiling mounted UL listed clean Agent (HFC-236fa), Modular typeFire Extinguisher , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Fixed Bulb with Temerature 68 deg C, QR code for Product Traceability including Fixing on Ceiling with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
545 Kg Capacity
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail