| 1 | Taking down carefully copper/ aluminium point wiring of light, fan, socket 5/15Amps or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards/sunken box and making good the disturbed of wall/ceiling/floors etc so as to match with the existing surface complete all as specified and as directed. |
| 2 | Taking down carefully sub main wiring including copper/ aluminium/ GI earth continuity conductor and making good the disturbed surfaces complete all as specified and directed. |
| 3 | Taking down main/ sub main MCB DB with MCBs of any size and capacity along with teakwood boards and including all fittings/furniture carefully and making good the disturbed surfaces complete all as specified and directed. |
| 4 | Material and labour for point wiring for one light point controlled by one way switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable(Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including white/ ivory colour heavy duty pvc casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) and fixing on wall/ ceiling including PVC board with cover (ISI marked)for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copperconductor cable as earth continuity wireand connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed. |
| 5 | (a)For one light point controllled by one switch |
| 6 | (b)For one ceiling fan point controllled by one switch |
| 7 | (c)For one exhaustfan point controllled by one switch |
| 8 | (d)For one bell point controlled by one switch |
| 9 | (e)For one 5 Amp independent socket point controlled by one switch |
| 10 | (f)For one 5 Amp socket point controlled by one switch on same board |
| 11 | M & L for point wiring complete with and including single core PVC, FRLSH, insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn thorough and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceilling including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing totally concealed in walls with 3 mm thick industrial laminated sheet top cover fixed flush with wall surface by means of brass screws and sunk/cupwashers for mounting of switches,socketsfan regulators etc including 1.5 Sqmm (22/0.30 mm ) 1100 Volts grade PVC, FRLSH insulated unsheathed flexiable multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/fans etc at one end and to common earth dolly at other end all as specified directed |
| 12 | (a)For one light point controllled by one switch |
| 13 | (b)For one ceiling fan point controllled by one switch |
| 14 | (c )For one exhaust fan point controllled by one switch |
| 15 | (d ) For one bell point controlled by one switch |
| 16 | (e)One 6A, 5 pin socket outlet point on same board with other switches including earth wire and connected to common earth and earth terminal |
| 17 | (f)One 6A, 5 pin socket outlet point on independent board withincluding earth wire and connected to common earth and earth terminals |
| 18 | (g) One 16A 5 pin switch/socket out let point on independent board but cable of size 2.5 sqmm and earth cable of size 2.5 sqmm and connected to common earth and earth terminals. |
| 19 | Material and labour for point wiring for 15Amp independent socket point controlled by one switch complete with 1100 Volts grade 2.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable(Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) and fixing on wall/ ceiling including PVC board with cover (ISI marked)for mounting switches, sockets, regulators etc and providing one run of 2.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copperconductor cable as earth continuity wireand connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed. |
| 20 | Supply and fix switch flush type, single pole, one way, 6Amps, 240 Volts, white finish complete all as specified and directed. |
| 21 | Supply and fix switch flush type 16Amps, 240 Volts, single pole white finish complete all as specified and directed. |
| 22 | Supply and fix bell push, 5Amps, 240 Volts white finish complete all as specified and directed. |
| 23 | Supply and fix socket outlet, 5 pin, 6 Amps, flush type, white finish complete all as specified and directed. |
| 24 | Supply and fix socket outlet, 2 in1, 3 pin, 6/16 Amps, flush type universal, 240 Volt, white finish complete all as specified and directed. |
| 25 | Supply and fix electronic socket size, rotary, 5 speed step type regulator, 220-230Volts, and white finish complete all as specified and directed. |
| 26 | Supply and fix call bell, ding dong type, AC 230 Volts single pole |
| 27 | Supply and fix ceiling rose, surface bakelite of size 65mm x 20mm three terminals complete all as specified and directed. |
| 28 | Supply and fix lamp holder insulated body with back plate suitable for angle/ batten fitting complete all as specified and directed. |
| 29 | Supply and fix Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 30 | Supply and fix Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 31 | Supply and fix modular Bell push 6A 1 modulecomplete all as specified and directed. |
| 32 | Supply and fix Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 33 | Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 34 | Supply and fix Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 35 | Supply and fix White cover plate with frame,1 module complete all as specified and directed. |
| 36 | Supply and fix White cover plate with frame, 2 module complete all as specified and directed. |
| 37 | Supply and fix White cover plate with frame, 3 module complete all as specified and directed. |
| 38 | Supply and fix White cover plate with frame, 4 module complete all as specified and directed. |
| 39 | Supply and fix White cover plate with frame, 6 module complete all as specified |
| 40 | Supply and fix the following double door SDN 4 way metallic sheet metal enclosurefor DB when MCBs to be used 240 Volts with 100Amps rated bus bar complete fixed properly on/ in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified Make : Legrand or equivalent |
| 41 | All as per item No 27 above but SPN 8 way |
| 42 | Supply and fix sheet metal enclosure double door, vertical type for DB’s when MCB’s to be used triple pole and neutral 4ways, 415volts with 100amps rated bus bar fixed sunk/ flush to wall complete all as specified Make Legrand or equivalent |
| 43 | Supply and fix sheet metal enclosure double door, vertical type for DB’s when MCCB’s to be used as incomer including MCCB 100 Amp triple pole and neutral 4 ways, 415 volts with 100amps rated bus bar fixed sunk/ flush to wall complete all as specified Make Legrand/L&T/Havells/C&S |
| 44 | Supply and fix MCB SP 240volts, 6Amp to 32Amp, 10KA capacity having C-series connected with suitable lugs including testing and commissioning complete all as specified and as directed. Make: Havell\"s/ Schneider/ L&T/Legrand |
| 45 | -do- but SPN 16 to 32 Amps -do- |
| 46 | -do- but TPN 40 to 63 Amps -do- |
| 47 | Material and labour for sub main wiring with two single core PVC-FRLSH insulated unsheathed stranded copper conductor cable of size 4 Sqmm (Make: Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) with one single core PVC-FRLSH insulated unsheathed stranded copper conductor cable of size 4 Sqmm as a continuous earth wire complete all as specified and directed. Note: Two single core cables and one run of earth copper conductor/ casing capping will be measured and paid as one unit length. |
| 48 | Material and labour for sub main wiring with two single core PVC-FRLSH insulated unsheathed stranded copper conductor cable of size 6 Sqmm (Make: Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy duty PVC conduit with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) with one single core PVC-FRLSH insulated unsheathed stranded copper conductor cable of size 6 Sqmm as a continuous earth wire complete all as specified and directed. Note:- Two single core cables and one run of earth copper conductor/ conduit will be measured and paid as one unit length. |
| 49 | Material and labour for earthingcomplete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25metre deep below natural ground level) with top edge of the plate not less than 1.5metre below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to main switch board/ main DB’s/ earth test point with and including necessary excavation and earth work in any type of strata, PCC 1:3:6, type C1 in chamber wall with 50mm thick, RCC cover 1:2:4, type B0 duly reinforced with 6 mm diabar, @100mm both way with suitable lifting handle, charcoal dust and common salt mixed and packed in 150mm thick layer all around the earth plate, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh, GI protection pipe 15mm dia light grade up to 7.5m from electrode and engraving of earth marking on nearby structure/ building with cement motor 1:4 plate of size 200mm x 150mm x 15mm thick and writing of earth results with paint complete all as shown in electrical plate No. 5 of SSR Part-I complete all as specified and as directed. Note: - On testing if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 50 | Material and labour for cutting/ boring of PCC hard standing at a depth not more than 15cm deep and 15cm in breadth for passing earthling conductor and making good the disturbed surfaces with PCC 1:2:4 type B-0 or cement mortar 1:3 complete all as specified and as directed. |
| 51 | Supply and fix GI pipe light grade of size 15 mm bore for laying in trenches/ floors or walls including all fittings as required complete all as specified and as directed. |
| 52 | Material and labour for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/ pipe all as required at site complete all as specified and as directed. |
| 53 | Supply and Fixing LED lights fitting 1 x 20 watt, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 54 | Material and labour for bracket made out of GI pipe 40 mm dia medium grade, 1.2metre long bent to shape fixed with MS flat iron clamps made out of 40mm x 6mm thick, nuts, bolts complete all as specified and directed. |
| 55 | Supply and Fixing LED security light fitting 70 watt 230 V AC outdoor type with hight pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. |
| 56 | Supply and Fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with implact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 57 | Supply and fix switch flush type, single pole, one way, 6Amps, 240 Volts, white finish fixed in repairs including removing the old one complete all as specified and directed |
| 58 | Supply and fix switch flush type 16Amps, 240 Volts, single pole white finish fixed in repairs including removing the old one complete all as specified and directed. |
| 59 | Supply and fix bell push, 5Amps, 240 Volts white finish including fixed in repairs removing the old one complete all as specified and directed. |
| 60 | Supply and fix socket outlet, 5 pin, 6Amps, flush type, white finish fixed in repairs including removing the old one complete all as specified and directed. |
| 61 | Supply and fix socket outlet, 2 in1, 3 pin, 6/16Amps, flush type universal, 240 Volt, white finish fixed in repairs including removing the old one complete all as specified and directed. |
| 62 | Supply and fix electronic socket size, rotary, 5 speed step type regulator, 220-230Volts, and white finish fixed in repairs including removing the old one complete all as specified and directed. |
| 63 | Supply and fix call bell, ding dong type, AC 230 Volts single pole fixed in repairs including removing the old one complete all as specified and directed. |
| 64 | Supply and fix lamp holder insulated body with back plate suitable for angle/ batten fitting fixed in repairs including removing the old one complete all as specified and directed. |
| 65 | Supply and Fixing LED lights fitting 1 x 20 watt,220 V AC decorative box type with driver, holder including LED tube light conncting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 66 | Supply and Fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 67 | Disconnecting and taking down ceiling fan of any sweep any make from any position at site, transporting to MES store Yard and dismantling blades, opening the stator and rotor of ceiling fan and providing new lubricating grease in bearing/bushes, re-assembling, commissioning and testing complete and rehanging/ re-fixing/ placing fan at same location at site includingproviding nuts, bolts, locking bolts, blade\"s screws, split pin, rubber real, PVC connector, washers etc. as required complete all as directed.Note: - All major repairs such as replacement of bush, bearing, condenser, shaft, connection wire, winding & painting will be measured and paid separately under appropriate item of Schedule. |
| 68 | Disconnecting and taking down exhaust fanof any sweep any make from any position at site, transporting to MES store Yard and dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/ bushes, re-assembling, commissioning and testing complete and rehanging/ re-fixing/ placing fan at same location/ other location at site, includingproviding nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers etc., as required complete all as directed.Note: - All major repairs such as replacement of bush, bearing, condenser, shaft, connection wire, winding and painting will be measured and paid separately under appropriate item of Schedule. |
| 69 | Material and labour for removing of burnt winding from ceiling fan 1200/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing and testing on completion, including transportation of fan to contractor\"s work shop and bringing back to store etc. complete all as directed. |
| 70 | Material and labour for removing of burnt winding from exhaust fan 300mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing including spray painting of grey colour and testing on completion, including transportation of fan to contractor\"s work shop and bringing back to store etc. complete all as directed. |
| 71 | Material and labour for removing of burnt winding from exhaust fan 450mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing including spray painting grey colour and testing on completion, including transportation of fan to contractor\"s work shop and bringing back to store etc. complete all as directed. |
| 72 | Material and labour for removing of burnt winding from wall/table fan 400/300mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing, painting of existing colour and testing on completion, including transportation of fan to contractor\"s work shop and bringing back to store etc. complete all as directed. |
| 73 | Material and labour for painting of ceiling fans of 1200/1400mm sweep by scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod as preparatory work for painting of ceiling fan and painting with one coat of supper enameled white paint with spray painting technique and writing of MES No. with capital letter of size 20mm height and 3mm width with synthetic enameled black paint complete all as directed. |
| 74 | Supply and fix gun metal bush suitable for ceiling fan/ exhaust fan all as per site requirement including removing the old one complete all as directed. |
| 75 | Supply and fix capacitor with PVC clamp of 2.5MFD capacity suitable to fans including removing the old one complete all as directed. |
| 76 | Supply and fix capacitor with PVC clamp of 4MFD capacity suitable to fans including removing the old one complete all as directed. |
| 77 | Material and labour for ceiling fan/ exhaust fan/ wall fan shaft complete of size and quality as per existing in repairs complete all as directed. |
| 78 | Supply and fix ball bearing of No 6201 Suitable to ceiling fans including removing the old one complete all as directed. |
| 79 | Supply and fix ball bearing of No 6202 Suitable to ceiling fans including removing the old one complete all as directed. |
| 80 | Supply and fix PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5Sqmm suitable to fan including removing the old one complete all as directed. |
| 81 | Supply and fix PVC insulated three core wire copper conductor 1100 Volt grade of size 1 Sqmm suitable to fan including removing the old one complete all as directed. |
| 82 | Taking down ceiling fan, remove the down rod and providing new down rod made out of GI tubing medium grade cutting, threading and drilling holes both ends (dual arrangement), making holes 02 Nos, painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan including electric connections complete all as directed. Note: - GI down rod shall be measured and paid for separately under appropriate item of schedule as supply only. |
| 83 | Material and labour for removing and refixing of celing fan at the same place or any other place by connecting with 3 core flaxible wire from ceiling rose to connector asdirected by Engineer -in- Charge. |
| 84 | Supply and fix GI tubing 15mm bore medium grade ISI marked complete all as directed. |
| 85 | Taking down carefully existing storage type water heater (Geysers) of any make and capacity (25/ 50 litres) including disconnecting water connection (inlet and outlet) for repairing/ painting etc and refixing the same or any other location by providing 04 Nos of anchor bolts and connecting up after cleaning, repairing and painting complete all as directed. Note:(a) Defect developed while taking out the geysers, such as leaking of joints, damaging of thread of pipe/ geyser and other GI fittings such as elbow, nipple, union, socket, etc shall be rectified/ replaced by the contractor at his own cost. (b) Replacing the PVC connection, heating element, thermostat, safety valve, inner tank and painting work shall be measured and paid separately under relevant item of schedule. |
| 86 | Material and labour for scrapping the old painted surfaces of geyser, cleaning and painting with two coats of white synthetic enamel paint over a coat of red oxide primer including writing MES No. with black paint with minimum 25mm size of letters for 25 litres capacity geysers complete all as directed. |
| 87 | Material and labour for taking out geyser inner tank from geyser body, 25/ 50 litre capacity making the tank leak proof by necessary brazing/ welding work, repair to collar, testing for leakage and fixing back to the body with collar gasket complete all as directed. |
| 88 | Material and labour for taking out geyser inner tank from geyser body by opening bottom plate, 25 litre capacity replacing with new inner copper tank of existing size, re-assembling, testing and fixing back to the body complete all as directed. |
| 89 | Supply and fix heating element push type 1.5 KW/ 2KW ISI Marked fixed in repairs including removing the old one complete all as specified and directed. |
| 90 | Supply and fix geyser thermostat of ISI marked, suitable for 20 degree to 80 degree centigrade in 25/ 50liter capacity geyser fixed in repairs including removing the old one complete all as specified and directed. |
| 91 | Supply and fix safety valve, vertical type made out of brass chromium plated, size 15mm, heavy duty fixed in repairs including removing the old one complete all as specified and directed. |
| 92 | Supply and fix non return valve, vertical type, made out of brass suitable for 15 mm GI pipe including cutting and threading of G.I. pipe and G.I. fittings such as socket, union, elbow, nipple, etc. fixed in repairs including removing the old one complete all as specified and directed. |
| 93 | Supply and fix PVC connection hot water grade 450mm long 15 mm dia with two Nos coupling nut of brass, heavy duty fixed in repairs including removing the old one complete all as specified and directed. |
| 94 | Supply and fix heavy duty water connection pipe (flexible steel) 450mm long and 15mm dia with two Nos coupling nut of brass, heavy duty fixed in repairs including removing the old one complete all as specified and directed. |
| 95 | Supply and fix flexible copper wire 3 core PVC insulated and PVC sheathed size 2.5Sqmm x 3core including removing the old one complete all as specified and directed. Make : Plaza/ Finolex/ Polycab |
| 96 | Supply and fix sheet metal single pole and neutral enclosure for 2 pole and earth metal plug and socket for incorporating 20 Amp SPN MCB with and including 20amp SPN MCB including removing the old one complete all as specified and directed. |
| 97 | Supply and fix glass wool for 25/ 50 litre capacity geyser by taking out inner and outer tank and reassembling complete all as specified and directed. |
| 98 | Taking down the existing old unserviceable Electric KWH meter\"s SP/TP upto 60 Amps from any position including disconnecting the all incoming/ outgoing electrical connection, all as directed by Engineer-in-charge.Note :- KWH energy meters property of the department, will be deposited in the E/M store at the respective station under AGE E/M Panaji |
| 99 | Supply and fix microprocessor based electronic energy meter, AC Three phase, tamper proof in polycarbonate casing 10 to 60Amps, 2wire, class1.0, 240Volt, 50Hz with down load and TOD facility all as per E-in-Cs policy, having LCD display low power consumption less than 1.0watt, LED indication for current reversal tampering, phase available indication all anti tamper futures, meter records correct energy with same accuracy under reverse current connection as per IEC 61036 and IS 13799 including necessary fixing arrangements and connecting up incoming and outgoing electric connections complete all as specified and as directed. Make: L&T/ HPL/ Secure. Note: (i) The digital type, flame proof electronic meter shall have following configuration :- (a) Indicator LED for reverse indication, Phase available indication, earth tamper indication, calibration.(b) Base bakelite 2 wire, single phase. (ii) The Initial reading at the time of installation of digital type meter shall be recorded and submitted to Engr-in-Charge. (iii) Accessories required for fixing to energy meters will be provided by contractor at no extra cost to the Government. |
| 100 | Supply & Fixing electronic energy meter SP upto 10-60 Amps and connecting up incoming & outgoing electric connection complete all as specified |
| 101 | Supply and fix SMC box with hinge type fitting arrangement moulded in engineering plastic, including taking down old unserviceable cupboards complete all as directed. Make : HPL/ Havell’s/ Sintex |
| 102 | Supply and fix teak wood board, close recessed type 50mm deep, well-seasoned, polished and finished of size 30cm x 25cm covered with additional mica top fixed in position, including PCC cement work if required at site complete all as directed. |
| 103 | Material & labour for painting sheet metal metering box including inner portion with super enamelled paint over a coat of primer complete all as specified and directed. |