Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-03-2023 | Engineers cost 20.03.2023 | Other | 28-03-2023 |
| 2 | 27-02-2023 | Corrigendum dated 27.02.2023 | Other | 28-03-2023 |
| Sl. No. | Item Description |
| 1 | Part A : Civil Work |
| 2 | EARTH WORK |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m and all lift upto 1.5m, disposed earth to be levelled and neatly dressed:All kinds of soil |
| 4 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas(exceeding30cmindepth,1.5minwidthaswellas10sqmonplan)including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: |
| 5 | Oridinary Rock |
| 6 | Hard Rock (Blasting Prohibited) useful material 30 % |
| 7 | Earthworkinexcavationbymechanicalmeans(HydraulicExcavator)/manualmeansin foundation trenchesordrains(notexceeding1.5min width or10sqmonplan)including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soilanddepositingandrefillingofjhiriwithwatering&ramminganddisposalofsurplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. |
| 8 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sum on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available. |
| 9 | Oridinary Rock |
| 10 | Hard Rock (Blasting Prohibited) useful material 30 % |
| 11 | Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in |
| 12 | In all kind of soils. |
| 13 | In Ordinary rock and hard rock. |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 15 | SupplyingandFillinginplinthwithriversandunderfloorsincludingwateringramming consolidating and dressing complete including cost of sand |
| 16 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 17 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRECONSTRUCTIONALAntitermitetreatmentasperIS6313partIIIasamendedfrom time to time and creating a continuous chemical barrier under and around the column pits, walltrenches,basementexcavation,topsurfaceofplinthfilling,junctionofwallandfloor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 18 | Carriage of earth etc by mechanical transport includeing, loading, unloading and stacking |
| 19 | Up to 5 Km |
| 20 | Construction of embankment with approved material obtained from borrow pits with all lifts andleads,transportingtosite,spreading,gradingtorequiredslopeandcompactingby vibratory roller 8-10 Tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with ALL lead As per MoRTH specification Clause No. 305. |
| 21 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 22 | CONCRETE |
| 23 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 24 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls,returnwalls,walls(anythickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15gradeNominalMix.1:2:4(1cement:2coarsesand:4gradedstone aggregate 20mm nominal size). |
| 25 | Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as perspecification . 50 mm thick. |
| 26 | REINFORCEDCEMENTCONCRETE |
| 27 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 28 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level |
| 29 | Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 30 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor locks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 31 | Columns, pillars, posts and struts etc. |
| 32 | Grid roofing with panel area less than 2.25 Sqm. (contact area to be measured). |
| 33 | Add extra for shuttering in circular work (in respective centering and shuttering items) |
| 34 | Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof . |
| 35 | Addextraforadditionalheightincentring,shutteringwhereeverrequiredwithadequate bracing,proppingetc.includingcostofde-shutteringanddecentringatalllevels,overa heightof3.5m,foreveryadditionalheightof1metreorpartthereof(Planareaistobe measured) |
| 36 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 37 | Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 38 | Add extra for reinforcementin superstructure above floor five level for each four flooror part thereof . |
| 39 | Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20\M 25\M 30 grade Design Mix by using cementas per codal provision. |
| 40 | Add extra for RCC work in superstructure above floor five level for each four flooror part thereof . |
| 41 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shadeofwalltreatment. Aluminum fluted strips 2 mm thick |
| 42 | Providingandfixingexpansion jointboardforbuildingRCCcolumnbeams,walls,slabof Polyethylene foam of density 30 to 35 Kg/m3 of Armour Board. |
| 43 | 40 mm Thick |
| 44 | Supplyingandprovidingoftwocomponentspolysulphidesealantcontainingsolid contents, confirming tostandard specification and approved compatibleprimer, for primingverticalfacespriortoapplicationofpolysulphidesealantincludingall labour charges for sealing of expansion joints after drillmixing of twocomponents sealingcompound.Cleaningandpreparationofexpansionjointusingwirebrush sandpaperingwithemerypaperandfilingwithsuitablemechanicalmeans.The work includes racking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant in joint. |
| 45 | Tojoints in flooring, as per drawing with first layer of poly sulphide sealant in size20mmwidthand10mmdepthoverPEFoamandthenprovidingpolyethylene foambackuprod25mmdiasizeandfinallyprovidinganotherlayerofpoly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge. |
| 46 | BRICK/ RRSM WORK |
| 47 | Random Rubble stone masonry for with hard stone in Foundation and Plinth in Cement Sand mortar above 30 CM thick wall in: |
| 48 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 49 | Random Rubble stone masonry with hard stone in Superstructure above Plinth level and upto five levelabove 30cm. thick walls in : |
| 50 | Cement Mortar 1:4 ( 1-Cement : 4-Sand). |
| 51 | Brickworkwith F.P.Sbricksofclassdesignation 7.5in superstructureabove plinth level upto floor five level in all shapes and sizes in : |
| 52 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 53 | Add extra for brick work in superstructure above floor five level, for each four floors or partthereof. |
| 54 | Quantity in Cum. |
| 55 | Quantity in Sqm. |
| 56 | Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonary 150mm/230mm/300mm thick with Grade-I AAC blocks in superstructure above plinth level upto floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 57 | Half brick masonry with mechanised autoclaved flyash lime bricks conforming to IS: 12894-2002of class designation 100 in Superstructure, above plinth level upto floor fivelevel. |
| 58 | Cement mortar 1:4 (1-Cement:4-coarse sand). |
| 59 | Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry |
| 60 | MARBLE WORK / STONE WORK |
| 61 | ProvidingandfixingGranitestoneslabmirrorpolishedandmachineedgecutinwalls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 62 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) |
| 63 | Up to 1500 Cm2 Tiles |
| 64 | 1501 Cm2 to 3600 Cm2 Tiles |
| 65 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls,steps,pillarsetc.laidon abedofneatcementslurryfinishedwith flush pointinginthewhitecementmixedwithpigmenttomatchtheshadeofthetilecomplete (excluding the cost of cement plaster on walls and pillar). |
| 66 | Extraforusingsize above 200x300mm in glazed tiles |
| 67 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite, grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazed tilesandMATfinishedtiles. |
| 68 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming toIS:13755andIS:15622coloursuchaswhite,grey,ivory,fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed withpigment tomatchthe shadeof thetile complete(including thecost of cement mortar bed 1:4). |
| 69 | Extra for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 70 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite, grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazed tilesandMATfinishedtiles. |
| 71 | Providingandfixing75 mm wide DecorativeBorderindifferentshadesandin all coloures in glazed tileslaidover12mmthickbedofcementmortar1:3(1 cement:3coarsesand)[email protected] including pointing in white mixed with pigment of matching shade complete. |
| 72 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 73 | Granite/Kota Stone Work Full Edge moulding |
| 74 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holesfor pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 75 | Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m heightwith 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filledwithagroutof12mmthickcementmortar1:3(1cement:3coarsesand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) |
| 76 | Exposed face Machine cut |
| 77 | Providing and fixing Stainless Steel Cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 Coarse sand) including making the necessary chases in stone and holes in walls wherever required |
| 78 | WOOD WORK & PVC WORK |
| 79 | Providing and fixing external grade board solid core single leaf flush door shutters IS:2202(Part-II)1996markedusingPhenolformaldehyderesin ingluebothsideswith approved stainless steel fittings complete as per annexure \"A\": |
| 80 | 35 mm thick shutter Decorative Teak veener both side |
| 81 | 35 mm thick shutter Commercial Veneer both side |
| 82 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item |
| 83 | Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area ofdoor shutter to be measured) : |
| 84 | Extra if louvers (not exceeding 0.2 sum) are provided in flush door shutters (overall area of door shutters to be measured).. |
| 85 | Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured). |
| 86 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : |
| 87 | Kota stone minimum 30mm thick. |
| 88 | Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : |
| 89 | 12mm thick Acoustical Board |
| 90 | Providing and fixing 50 mm thick resin bounded glass wool 32 kg/cum density wrapped in julities cloth bag (box type) and held in position using chicken mesh |
| 91 | Providing and fixing Hassian cloth of approved colour and texture over soft wood frame glass wool & fibre glass tissuse paper |
| 92 | Providing and fixing expandable fastners of specified size with necessary plastic sleeves and galvanisedM.S.screwsincludingdrillingholesinmasonrywork/CC/R.C.C.andmaking good etc. complete |
| 93 | 50 mm long |
| 94 | STEEL WORK |
| 95 | Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. |
| 96 | Electric resistance or induction butt welded tubes |
| 97 | ProvidingandfixingT-ironframesfordoors,windowsandventilatorsofmildsteelTee- sections,jointsmitredandweldedwith15x3mmlugs10cmlongembeddedincement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize)orwith woodenplugsandscrewsorrawlplugsandscrewsorwith fixingclipsorwith boltsandnutsasrequireincludingfixingofnecessarybutthingesand screws and applying a priming coat of approved steel primer. |
| 98 | ProvidingandfixingpressedsteeldoorframesconfirmingtoIS4351manufacturedfrom commercialmild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead andifrequiredanglethresholdofmildsteelangleofsection50x25mm,orbasetiesof 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugswithsplitendtailtoeachjambincludingsteelbutthinges2.5mmthickwithmortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steelprimerafterpre-treatmentofthesurfaceincludingfillingwithCC1:2:4(M15grade) complete as directed by Engineer-in-charge : |
| 99 | Profile E |
| 100 | Supplyandfixingin cementmortarweldedhandrailingmadeoutofMSroundorsquare bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. |
| 101 | Extrafor providing D type pipe head as top of hand railing |
| 102 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats or blackpipewith holdfastandfittingscompleteasperdesign anddrawingincludingcutting welding and fabrication with priming coat of red oxide |
| 103 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). |
| 104 | Supplyingandfixingrollingshuttersof approvedmake, madeof 80x 1.25mm.M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for insideandoutsidelockingwithpushandpulloperationcompleteincludingcostofspring hooks, providing and fixing necessary 27.5cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design and IS 6248:1979 (Clear openable area to be measured for payment). |
| 105 | Providing and fixing boll bearing for rolling shutters |
| 106 | Extraforprovidingmechanicaldevicechainandcrankoperationforoperatingrollingshutters. |
| 107 | Exceeding 16.80 Sqm in the area. |
| 108 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of16gaugethickness,jointmitredwelded andgrindedincludingholdfastofsteellugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge |
| 109 | Window fixed. |
| 110 | Window openable. |
| 111 | ExtraforadditionalshutterinpipesectionwindowswithGalvanisedM.S.Wire gauge 14 mesh x 24 gauge |
| 112 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 |
| 113 | Providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelISI section 80x25 mmx1.25 mm thickwith 1.00 mm MS sheet to spot weldedincludingholdfastsof15x3mm,MSoxidizedfittingssuchasbutthinges, slidingdoorsbolts,handles,towerboltsandtwinpegetccomplete including applying priming coat of approved steel primer of red oxide zinc chromate andspray paintinginapprovedshadewithdeco paintofapprovedqualitycompleteasper direction of Engineer In Charge |
| 114 | ROOFING |
| 115 | Providing & fixing calcium silicate ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:- |
| 116 | 8 mm thick |
| 117 | Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling withdashfastener12.5mmdiax40mmlongwith6mmdiaboltstotheanglehangersof 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board w / weather resistant sealed against air and water complete as per drawings, requirements , specificatio |
| 118 | the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also includingthecostofmakingopeningsforlightfittings,grills,diffusers,cutoutsmadewith frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. |
| 119 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm andlayingfalseceilingtilesofapprovedtexturein thegridincluding,wherever,required, cutting/making,openingforserviceslikediffusers,grills,lightfittings,fixtures,smoke detectors etc. Main “T” runners to be suspender IGBC scheme. und conforming to IS : 2645. iling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineerin-Charge. |
| 120 | Providing&fixingUVstabilisedfiberglassreinforcedplasticsheetroofinguptoanypitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufacturedoutof2400TEXpanelrovigsincorporatingminimum0.3%Ultra-voilet stabiliserinresinsystemunderapproximately2400psiandhotcured.Theyshallbeof uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. |
| 121 | 5.0 mm thick (Wt.8.4 Kg./Mtr.Sq.) |
| 122 | Extra for corrugated Fiberglass Reinforced Plastic (FRP) (2.5\" /4.2\"/6\") or step down (2.5\"/4.2\"/6\") as specified |
| 123 | Providing and laying integral cement based water proofing treatment including preparation of surfaceasrequiredfortreatmentofroofs,balconies,terracesetcconsistingof following operations.(a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed withproprietarywaterproofingcompoundconformingtoIS.2645overtheRCCslab including cleaning the surface before treatment.(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cementmortar1:4(1cement:4coarsesand)admixedwithproprietarywaterproofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4(1 cement :4 coarse sand)admixed with proprietary water proofing compound conforming to IS:2645torequiredslopeandtreatingsimilarlytheadjoiningwallsupto300mmheight including rounding of junctions of walls and slabs.(c)Aftertwodaysofpropercuringapplyinga secondcoat ofcement slurryadmixed with proprietary waterr IGBC scheme. und conforming to IS : 2645.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarsesand)admixedwithproprietarywaterproofingcompoundconformingtoIS:2645 and finally finishing the surfacewithtrowel withneatcement slurryand makingof 300x300xmm square(e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge.With average thickness of 120mm and minimumthickness at khurra as65 mm. |
| 124 | Makingkhurras450x450mmwithaverageminimumthickness50mm cementconcrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1:3 and onecoat of neat cement, rounding edges and making and finishing the out let complete. |
| 125 | FLOORING |
| 126 | Cementconcreteflooring1:2:4(1cement:2coarsesand:4gradedstoneaggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. |
| 127 | 40 mm thick with 20 mm thick nominal size aggregate. |
| 128 | Cement plaster in skirting and/dado 18 mm thick with cement mortar 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement including rounding of junctions with floor |
| 129 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. |
| 130 | 40 mm wide and 4 mm thick. |
| 131 | Providing&layingChequerredterrazzotilesofapprovedmake22mmthickwithmarble chipsofsizeupto6mm,infloors,jointedwithneatcementslurrymixedwithpigmentto matchtheshadeoftilesincludingrubbingandpolishingcompleteinallrespectasper specification, on 28 mm thick bed of C.M. 1:4 |
| 132 | Medium shade using approximately 50% white cement and 50% ordinary cement. |
| 133 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 134 | For area of each slab from 2001 to 5000Sq. Cm : |
| 135 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 136 | For area of each slab upto 2001Sqcm |
| 137 | Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete. |
| 138 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. |
| 139 | size 600 mm X 600 mm |
| 140 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mmthickness instead of cement mortar. |
| 141 | Providing and fixing Marble stone flooring table rubbed, 15 -18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointingwith whitecement mortar1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 142 | Rajnagar 1st quality/Ageria with light spots. |
| 143 | Up to 1500 Cm2 Tiles |
| 144 | Keseriaji/ Abu Ambaji (Green Marble) |
| 145 | 1501 Cm2 to 3600 Cm2 Tiles |
| 146 | Crazymarblestoneflooring20mmthickmarblestonewithblackorofspecifiedcolour toppingincludingfillingthegapswithcementmarblechipsmixinproportionof4:7(4- Cement:7-White black or white or black marble chips) size from 1 mm to 4 mm by volume and under layer of 25 mm thick cement concrete [1:2:4, graded stone aggregate 12.5 mm nominal size] rubbing and polishing and cement slurry etc. complete : In ordinary cement |
| 147 | Random rubble dry stone Kharanjaunder floor. |
| 148 | FINISHING |
| 149 | Plasteronnewsurfaceonwallsincementsandmortar1:6includingrackingofjointetc. complete fine finished: |
| 150 | 12 mm thick. |
| 151 | Plasteronnewsurfaceonwallsincementsandmortar1:4includingrakingofjointsetc. complete fine finish: |
| 152 | 20 mm thick. |
| 153 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 154 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 155 | Finishing with neat cement (Punning). |
| 156 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 157 | Extra for making Ornamentaldesign like KangoorasGola etc.asperJaipur practice in 12 mmcementplaster |
| 158 | Extra for making Ornamentaldesign like KangoorasGola etc.asperJaipur practice in 20mmcementplaster |
| 159 | 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) : |
| 160 | Flush band. |
| 161 | Sunkband. |
| 162 | Mouldedband. |
| 163 | Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish : |
| 164 | 12 mm thick. |
| 165 | Extraforplasteringexteriorwallsofheightmorethan10mfromgroundlevelforevery additional height of 3 m or part thereof. |
| 166 | External Plaster |
| 167 | Providing and Fixing Chiken wire mesh at the joint of masonry members/ R.C.C. Members with Nails complete in all respect. |
| 168 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: |
| 169 | New work (two or more coats) over and including scrapping andpriming coat with cementprimer. |
| 170 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 171 | Newwork(Twoormorecoats) includingprepartionofbasewithprimer,putty,lippyetc complete in all respect. |
| 172 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) |
| 173 | Paintingwith syntheticenamelpaintofapprovedbrandandmanufactureto givean evenshade : |
| 174 | Two or more coats on new work |
| 175 | French sprit polishing |
| 176 | Two or more coats on new work including a coat of wood filler. |
| 177 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. Newwork([email protected]/10sqmoverandincludingbasecoatof water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 178 | Finishingwallswithtexturedexteriorpaintofrequiredshadeasperapprovedcolour completeaspermanufacturersspecificationsincludingprimercoatandprotectingcoat including scaffolding and safety provision |
| 179 | Trowel Finish av. thickness 1000 to 1200 microns. |
| 180 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc.Good soil of earth |
| 181 | DISMANTLING AND DEMOLISHING WORK |
| 182 | DemolishingR.C.C.workmanually/bymechanicalmeansincludingstacking ofsteelbars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 183 | Demolishingbrickworkmanually/bymechanicalmeansincludingstackingofserviceable materialanddisposalofunserviceablematerialwithin50metresleadasperdirectionof Engineer-in-charge. |
| 184 | In Cement mortar. |
| 185 | Dismantlingbricktilescoveringin terracingincludingstackingofserviceablematerialand disposal of unserviceable material within 50 meters lead. |
| 186 | Demolishingmudphuska/Limedhar/Kharanjain terracinganddisposalofunserviceable material within 50 meters lead. |
| 187 | WATER PROOFING |
| 188 | Providing & applyingone coatof UVresistant polymercement basedwaterproofing slurry coating of approved make and quality on concrete or plastered surface as perspecifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemicalwith 2 parts of cement and 2 partsofwater(coveringarea 1.86Sq.M/Kg ofchemical) includingcost ofcement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge.Note: Undulations/cracks found on the surface should be rectified with Cement Motor before application and the same will be paid under relavent items. |
| 189 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours.b)Secondlayerofslurry [email protected]/sqmmixedwithwaterproffingcement compound @ 0.126 kg/sqm Thislayer willbe allowedto aircure for 4 hoursfollowed by water curing for 48 hours.The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry.Note : Rendering/ Plastering as protective layer, if required will be paid seperately) |
| 190 | ALLUMINIUM & PVC WORKS |
| 191 | Providingandfixing aluminumwork fordoors,windows,ventilatorsandpartitionwith extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawlplugs and screws orwith fixing clips, or with expansion hold fasteners including necessary filling up of gap. at junctions, at top,bottomandsideswithrequiredPVC/neoprenefeltetc.Aluminiumsectionshallbe smooth,rustfree,straight,miteredandjointedmechanicallywhereverrequiredincluding cleat angle Aluminium snap beading for glazing /paneling, C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc., all complete as per architectural drawings and thedirections of Engineer- in – charge. (Glazing and paneling to be paid for separately). |
| 192 | For fixed portion |
| 193 | Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 194 | Forshuttersbuiltupstandardtubularsectionsofopenabledoors,windows&ventilators includingproviding&fixinghinges/rollersetc.andmakingprovisionforfixingoffittings wherever required (lockes shall be paid for separately). |
| 195 | Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 196 | Extra for shutters of slidingaluminum windows |
| 197 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. withPVS/neoprenegasketetc.completeasperthearchitecturaldrawingsandthe directionsofengineer-in-charge.(Costofaluminiumsnapbeadingshallbepaidinbasic item.) |
| 198 | With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 199 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. |
| 200 | With stainless steel cover plate |
| 201 | Providingandfixingexpandedgrillmadeofaluminumasperdesignanddrawinghaving members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middlejointsr+C395espectivelycompleteinallrespectasperdirectionofengineerin charge. |
| 202 | Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 203 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 204 | S & f fixed wire gauge of stainless steelof 14meshx24gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150 mm distance at all heights with all lead and lift with scafolding. |
| 205 | Providing and fixing Structural glazing work with toughened glass of 6mm thick and reflective colour as approved in dark shade like Blue/Dark Blue etc. with frame work of curtain section 65x60mm (Weight 1.64 kg/m min.) made of aluminium with chrome plating. Internal frame work will also be of curtain section 65x60mm of chrome plated aluminium section with20x20mm aluminium tube section andstructural spacer made of rubber. The aluminium frame work size as per instruction of Engineer-in-charge and including openable panels with all necesary sections and fitting.The work include silicon structural adhesive for completegripping of glass with framing members and silicon weather seal sealant to prevent moisture/water through joints. Glass will be fixed in plumb and with uniform spacing of 10-12mm wide duly filled with silicon weather seal sealant. Thework includes all labour,scaffolding , structural aluminium work, toughened glasses,silicon weather seal sealant, silicon structural adhesive structrucal spacer, all accessoreis like handles, peg stays, M-15 grade cement concrete for fixingholdfast .(Face area of glass shall be measured) |
| 206 | ROAD WORK |
| 207 | Constructionofsubgradeandearthenshoulderswithapprovedmaterialobtainedfrom borrow pits with all lifts and leads, transporting to site, spreading, grading to require slope andcompactedbyvibratoryroller8-10Tonneto meetrequirement ofTable 300-2as per MoRTH specification Clause No. 305. |
| 208 | Providingandlayinggranularsub-basematerialhavingP.I.notmorethan6including spreading in layers not exceeding 150 mm compacted thicknessand consolidation by 8-10 tonne power rollerto required camber and grade including cost of water and hire charges of machineryincludingT&Pwithalllead(Compactedthicknesstobemeasured).asper MoRTH specification table 400-1, 400-2, |
| 209 | For grading-I with CBR value not less than 30. To attain 100% proctor density. |
| 210 | Providing, laying, spreading and compactingstone aggregate forWet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying inuniformlayerswithmotorgrader/FrontendLoader/paverfinisher,insubbase/base course on a wellpreparedunder baseand compactingwith vibratoryroller toachieve the desireddensityincludinglighting,guarding,barricadingandmaintenanceofdiversion etc. (MoRTH specification : Clause 406) by mechanical means with lead up to 20 Km. |
| 211 | Providingandapplyingprimercoatoverpreparedsurfaceorgranularbasewithbitumen emulsion SS-1 as per IS: 8887 & manufacturer’s specifications @ 6 kg /10 Sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specifiedratesandtemperaturesasperMoRTHspecificationCI502&112(Including cleaning of road surface ) |
| 212 | Providing and applying tack coat on the prepared surface, withbitumen emulsion RS-1 as per IS : 8887 & manufacturer’s specifications @ 2 kg /10sqm. With a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MoRTH specification Clause 503 & 112 ( Including cleaning of bituminous road surface ) |
| 213 | Providing and laying Dense Bituminous Macadam on prepared surface with specified graded crushedaggregatesaspertable510anddesignmixforbase/bindercourseincluding loading of material with Front end loader, heating of binder (including cost of anti-stripping compound wherever required) aggregate and filler in hot mix plant 40-60 TPH, transporting the mixed material by tippers and laying with sensor paver finisher as per clause 507.3.5 to the required leveland grade rolling by self propelled power rollers and vibratoryrollers or pneumatic tyred roller 150-250KN. TP=0.7MPa to achieve the desired density (approved by the department) but excluding cost of primer/tack coat. [MoRTH Specification : Clause 507 & 112] |
| 214 | GradingII(19mmnominalsize)-Bitumen @4.0- 4.5% ofmix (60/70grade) VG30 & thickness 50 - 75 mm with lead of mix material 20km |
| 215 | Providingandlayingbituminousconcreteasperdesignmixonprepared surfacewith specified graded stone as per table 500-18 for wearing course including loading of aggregate with Frontendloaderandhotmixingofbinder(includingcostofanti-stripping compound, whereverrequired)and3%cementfillerwithaggregatesinhotmixplant40-60TPH Transporting the mix material with tipper and laying with sensor paver finisher (as per clause 507.3.5) to the required level, grades and rolling with vibratory compactorand pneumatic tyredroller150-250KN,TP=0.7Mpa,toachievethedesireddensity(approvedbythe department) excluding cost of primer/tack coat (MoRTH Specification : Clause -509 & 112) |
| 216 | Grading II (13 mm nominal size) - Bitumen @ 5 % of mix& thickness 30 - 45 mm with lead of mix material 20km |
| 217 | 60/70 grade VG 30 |
| 218 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cementinpositiontotherequiredline,levelandcurvaturejointedwithcement mortar1:3(1cement:3coarsesand)includingmakingjointswithwithout grooves(thicknessofjointsexceptatsharpcurveshallnottomorethan5mm) includingmakingdrainageopeningwhereverrequiredcompleteincludingpainting etc.asperdirectionof Engineer-in-charge(lengthof finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- charge). |
| 219 | Providingandlayingof paverblockasperIS15658:2006(Indianstandardfor precast concreteblockforpaving-specification)andIRC:SP:63-2004(guidelines for the use of interlocking concrete block pavement) |
| 220 | M-35,60mm thick to be used in light traffic (Light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 KN laden weight, or an equivalent up to 0.5 million standard axles (MSA) for a design life of 20 years(A standard axle is defined as a single axle load of 81.6 KN) like pedestrian plazas, shopping complexes ramps, car parks, office driveways , housing colonies, office complexes, rural roads with low volume traffic, farm houses , beach sites, tourist resorts, local authority footways, residential roads, etc. Category‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004 |
| 221 | M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily trafficof150-450commercial vehiclesexceeding30KN ladenweight, oran equivalent of 0.5to2.0MSAfora designlifeof20years.)likecitystreets,small andmediummarketroads,lowvolumeroads,utilitycutsonarterialroads,etc Category‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004 |
| 222 | Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. |
| 223 | Add extra over rates of item No. 11.38, A to C if colored paverblocks are used |
| 224 | HORTICUL TURE WORKS |
| 225 | Supply of dry manure including loading unloading,transportation & stacking at site. |
| 226 | Farm yard manure(organic) |
| 227 | Supply&Stackinggoodearthatsitecompleteincludingloadingunloading& transporation etc.Good soil of earth |
| 228 | Layingoflawnsincludingploughinglevelingbreakingofclodsmanuringandremovalof stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn for 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost |
| 229 | in rows 7.5 cm apart in either direction |
| 230 | Supply & Planting of shady plants ( Neem. Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities:- |
| 231 | Preparation of soil including cleaning & removing of unwanted shrubs removal of stones &garbage. |
| 232 | Supply of plant at site of two years of age & height more than 1.50 Mtr. |
| 233 | Supply of dry manure(Farm yard manure organic) |
| 234 | Supply of Insecticides. |
| 235 | Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 Liter per plant after planting |
| 236 | Watering to plants |
| 237 | Maintance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc & application of insecticiedes etc. & security. If the plant die during maintence contractor has to rplace same heingh plant at his own cost. |
| 238 | Supply&Pantingofornamentalplants(Kachnar,Amaltas,Gulmohar,Arjun,Kala,Siris, Jacranda etc. or other specified) along road side including the following activities :- |
| 239 | 1. Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage |
| 240 | Supply of plant at site of two years of age & height more than 1.50 Mtr. |
| 241 | Supply of dry manure( Farm yard manure organic) |
| 242 | Supply of Insecticides |
| 243 | Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 liter per plant after planting. |
| 244 | Waterring to Plants. |
| 245 | Maintenanceofplantsbythecontractorincludingpits.PreparationofThavalaHoeing weeding etc. & application of insecticides etc. & security. If the plant die during maintencance contractor has to replace same height plant at his own cost. |
| 246 | Planting & Maintenance of shrubs. |
| 247 | Planting of shrubs in central verge |
| 248 | Preparation of soil including cleaning & removing of unwanted shrubs removal of stones &garbage. |
| 249 | Supply of plant at site like Bouganvillia & Kaner. |
| 250 | Supply of dry manure( Farm yard manure organic) |
| 251 | Supply of Insecticides |
| 252 | Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 liter per plant after planting. |
| 253 | Waterring to Plants. |
| 254 | Maintenanceofplantsbythecontractorincludingpits.PreparationofThavalaHoeing weeding etc. & application of insecticides etc. & security. If the plant die during maintencance contractor has to replace same height plant at his own cost. |
| 255 | Furniture |
| 256 | 3 Seater fix seating arrangements This unit has to be mounted in a lecture theatre of step ladder type with each ladder of approx 1080 mm. The units have to aligned at side by side eith passage in between or as per layout approved by engineer in charge/ client. 3-seater desk size- Top : 1800W x 375 to 400D x 750H, Intermediate partition for storage : 1800W x 200D. The Desk top shall be made with 25 mm thick ply with 1 mm laminate of approved shade on both sides and 2 mm thick edge taping of matching colour on all edges. There shall be MS perforated modesty panels of 1.2 mm thick. Understructure consists of MS oval tube 70x30x2mm, rectangular pipe 75x30x2.5mm, 25x10x1.6mm, epoxy powder coated of 40-50 microns. All tube ends to be provided with high density caps. All corners to have 10 mm radius. 3 Seater seat size 1800W x 350D x 450H. Seat shall be 18 mm thick ply with 1 mm laminate of approved shade on both sides and 2 mm thick edge taping of matching colour on all edges and seat fixed to under structure with pop-up rivets. Understructure consists of MS oval tube 70x30x2mm, rectangular pipe 75x10x2.5mm, 25x10x1.6mm thick, 25x25x2mm, 55x35x2mm with base plate of 2 mm thick sheet grouted on floor, epoxy powder coated of 40-50 microns. All tube ends to be provided with high density. |
| 257 | Supply & fixing of fully insulated wooden fire door of approved Make of 120min. fire rating,of 52mm thickness,comprisingof75mmx 44mm hardwoodinternaltimber framework, with infillinsulationof20mmthickofof48kg/m3,woolinsulation,coatedwith intumuscent coating on both sides for insulation. The coated insulation shall be sandwiched between min 12mmthickNonCombustible(CalciumSilicate)Boardsonbothsides(edgetoedgeon internalHardwoodframe)andcladdedwith3mmThickCommercialply&1mmthick Laminate (Any Regular Plain Shade In Suede or approved Finish) on both sides, with 52mm x 10mm exposed teakwood lipping all round the shutter. The shutter shall be fitted withfire &smokeintumescentsealofsize 20x4mmonallthethreesidesexceptbottom.The pasting of the ply / laminate should be done using automaticc machine and should be free from any nails or perforations. The manufacturer should be compliant to ISO 9001: 2008 and CE certified, manufacturer should be covered under IGBC scheme. |
| 258 | The board shall be Resistant to vermin, mould growth, minor impact, abrasion and short term water attack and shall be Off –white in colour with asmooth surface suitable to receive most formsofdecorationhavingfollowingtechnicalcharactersi.e.; TheConstructiondesign similar to the design tested as per BS 476 part 22 and IS 3614 Part II, atCBRI, Roorkee or other approved lab. The shutter can be provided with appropriate openings forview panel glass,ifrequiredtheglassshouldbe 120min firerated tobe paidseperately. Prototype Test certificate forfire rating of doors from CBRI, Roorkee for earlier tested design shall be attached along with manufacturers test certificate. The shutter shall be fixed with the frame with the help of SS Ball Bearing hinges of size 100x75x3mmSingle/Double Shutter |
| 259 | Providing and fixing door frames as per BS: 476 part 22, IS:3614 Part II as per the prototype certified by CBRI Roorkee made out of 2nd class Teak Wood (Ivory Coast) frame of section 120x70mm for fire resistant doors of 120 minutes fire rating, with heat activated intumescent fire seal strips of size 20 x 4 mm ( for smoke sealing) provided in grooves on all three sides of the frame with one coat of approved brand of fire retardant primer including two coats of fire retardant paint FRS 881 un thinned on cleared hard wood surface of door frames (@3.5 sq.m.perlitrepercoat) includingpreperation ofbase surfaceas perrecommendations of manufacturer to make the surface fire retardant, including fixing the frame with 8 nos. 100 mmlong,10mmdiametaldashfastnerscompleteasperdirectionsoftheEngineerin charge. |
| 260 | Supply & fixing of Door Coordinator for proper coordination of double leaf door shutters so as to allow proper closing of door |
| 261 | Providing & fixing of 120 min fire rated glass of approved quality and manufacture. The glass should be compliant to class 2B2 category of Impact Resistance as per EN 12600. and is to be used as vision panel including cost of fire rated ceramic tape and moulding/beading all complete. Area of glass shall be measured for payment. |
| 262 | Providing and fixing Panic Bar single / doubleleaf panic exit devices of approved quality and manufacture for 120 min fire rated door. |
| 263 | Double Leaf Panic Bar |
| 264 | Supply & installation of door closers of approved qualityand manufacturefor 120min firerated door. |
| 265 | Supply & fixing of Mortise Lock With SS Lever Handle Of approved quality and manufacture for 120 min fire rated door |
| 266 | Supply&installationofapairofSSDTypePullHandleofsize300mmmmLongof approved quality and manufacture for 120 min fire rated door |
| 267 | Supply&installationofPanicTrimofapprovedqualityandmanufacturefor120minfirerated door |
| 268 | FIRE EVACUATION Photoluminicent Signages |
| 269 | ProvidingandfixingEmergencyEvacuationSignage:- Radius8to12mm,round Cornersignagesmadeof2 mmRigid PVCsheet withpremium photoluminicentof illuminationupto4hours.WithUVprintingforGraphicandtext.AdheringtoNBC2016 Standards.MountedusingSSscewsOR3MVHBtape,asperdirectionsofengineer incharge |
| 270 | FIRE EVACUATION PLAN |
| 271 | Providing and fixing Emergency Evacuation Signage :-Sandwhich Acrylic frame work of 5 mm + 5mm thickness. Signages made ofpremium photoluminicent of illumination upto 4 hours.WithUVprintingforGraphicandtext.AdheringtoNBC2016Standards.Mounted using SS Spacers 18 mm x 25 mm , as per directions of engineer incharge |
| 272 | Emergency Evacuation signagewith Battery backup |
| 273 | Providing and fixing Edge Lit Emergency Signage MODEL - EMEX3726- PremiumCasing:-Anodised Aluminium with Plastic / Metal Side Caps.Text Panel:-8 mm AcrylicBack Up Duration :- 180 MinutesPrimary Power Source:-AC - 150-240 VoltLuminarre:-LEDBattery Disconection Swith Battery Capacity:- 2000 AMH Battery Type:- Lithium ION AC to DC Built in Adaptor Fuse for Circuit protectionAC, Charging, EMERGENCY Indicators Emergency Test SwitchBattery Minimum Discharge Protection Battery Maximum Charge ProtectionInstallation:- Complete as per requirement of site/ engineer in charge |
| 274 | Providing and fixing Signageto be made ofstainless steel sheet of 2 thick 304 gradebrush finish including engraving/etching of letters of required size filled with colour as desired by engineer,fixing with ss screws on walls. |
| 275 | Providing and fixing INTERNAL INDETIFICATION SIGNAGE |
| 276 | Radius 8 to 12 mm, round Corner signages made of 2 mm Rigid PVC sheet With eco solvent printing on 3mm vinyl for Graphic and text.Mounted using SS scews OR 3M VHB tape, as per directions of engineer incharge |
| 277 | Main Entry Signage (SS 3D Letter) |
| 278 | ProvidingandfixingExternalSignage\"smadeofSS304(brushfinish)1mmthk.platefor Logopartandletters.Includingallfittings,accessories,fixtures,fabrication.Thecost toinclude Scafolding, required supports to fix signage on walls. The signage willbe hollow illuminatedwith IP67gradeapprovedLED\"salongwithSMPSandtimerfixedonthe wallwith necessary fixtures. |
| 279 | Providing and fixing BUILDING NAME IDENTIFICATION : Soft curved tote |
| 280 | Signage is to be made ofstainless steel sheet of 2mm thick 304 gradebrush finish including vinylforlettersofrequiredsizeofcolourasdesiredbyengineer,fixingwith ssscrewson walls. |
| 281 | Providing and fixing Compus Directional Signage |
| 282 | Double Sided Signage will be fabricated using ACP panel size 900x1500 as base duly fixed over modular aluminium extruded section frame of 50mm depth. Text & Graphics will be in 3MHIPgradeprismaticRetro-reflectiveselfadhesivesheetdulydigitallyplottercutand pasted on base on both side as per design. Signage will be grouted to RCC pedestal using MS Pole of 100X100x3600 mm, duly painted with base plate size 250x250x10 mm.RCC Foundation:- with 8 mm and 12 mm TMT Bars and 1:2:2 concrete of sz 450 x 450 x 750 mm for the post. |
| 283 | Providing and fixing Traffic regulatory Signage/ Parking |
| 284 | A)POST :- Signage is to be made oF 100x100 mm 1800 mm High MS pole,Base Plate of size 250x250mm of thickness 10mm is to be used.B) Panell-1 :- Panell size 400X110X1200 mm is to be made of 25 x 25X1mm MS framewith ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERY Prismatic Retro reflective sheet and approved color Overlay film on top having desired text and pictographs.C) Panell-2 :- Panell size 600X600 Sq with ACP 4 mm thick, 0.5 mm aluminium foil, 3M / AVERYPrismaticRetroreflectivesheetandapprovedcolorOverlayfilmontophaving desired text and pictographs.D)RCC Foundation:- with 8 mm and 12 mm TMT Bars and 1:2:2 concrete of sz 450 x 450 x 750 mm for the post. |
| 285 | Providing and fixing Entry/ Exit Signage |
| 286 | Signage sides is to be made of 50 mm width, extruded alloy6063 with in built in provision to received the sign face panel in 5 mm Acrylic on front and having provoison of hold the LED Modules . Sign face is to be made of graphic plotter cutvinyl as per graphic pasted over 5 mm thick white transluentacrylic. The panel should be made easily openable for maintinace point of view. |
| 287 | Providingandfixingdoubleglazedhermeticallysealedglazinginaluminiumwindows, ventilatorsandpartitionetc.12mmairgap,includingprovidingEPDMgasket,perforated aluminiumspacers,desiccants,sealant(Bothprimaryandsecondarysealant)etc.asper specifications, drawings and direction of Engineer-in-charge complete. |
| 288 | Colouredtintedbaseglass6mmthicksubstratewith reflectivesoftcoatingonface#2+ 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of minimum 40- 42 %, light reflection internal 12 to 25%, light reflection external 14 to 20%, shading coefficient (0.23- 0.24) and U value of 1.5 to 1.6 W/m2degreeKetc.Thepropertiesofperformanceglassshallbedecidedbytechnical sanctioning authority as per the site requirement |
| 289 | Part B : Sanitary Work |
| 290 | SANITARY FIXTURES |
| 291 | P & E Indian type white glazed vitreous .china 1st quality W:C. orissa pan (IS:2556 Mark) with100 mm vitreous china P or S trap including cutting and making good the wall and floor : |
| 292 | size 580x440 mm |
| 293 | P & F European type white glazed vitreouschina 1st quality Double symphonic W.C. (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. |
| 294 | P & F WVC Wash basin (1st quality\" IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:X934Mark) &32mmC.P.brasswastecouplingofapprovedmake25mmG.l. waste pipe complete including cutting & making good the wall : |
| 295 | size 550x400 mm |
| 296 | Size 630 mm x 500 mm dia for counter top |
| 297 | P&F W.V.C. Urinal Partition plate of approvedstandard make of size 630x315 mm including making good the wall. |
| 298 | P & F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. |
| 299 | Makrana II Quality marble having light spots. |
| 300 | P&F I quality WVC Urinal (IS :2556 mark) with 25 mm dia G.I. waste pipe, dome waste couplings\",; concealed iron brackets or screwsetc. complete. |
| 301 | Flat Back (large)half stall Urinal size 610x400x80 mm |
| 302 | P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mmC.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor : |
| 303 | WVC lab sink (IS : 2556 mark) size 530x430x180mm. |
| 304 | WVC lab sink (IS : 2556 mark) size 450x300x150mm. |
| 305 | 1.0 mm thick stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make as per Engineer-in-chargewith large waste coupling. |
| 306 | Overall size (45x20x8 inches ) and bowl size: 20x16x8 inches (With drain board) |
| 307 | Overall size (24x18x8 inches ) and bowl size: 20x16x8 inches (Without drain board) |
| 308 | P & F Chromium plated Swan-neck Laboratory Cock of approved quality / make: |
| 309 | One Way. |
| 310 | Two Way. |
| 311 | Providing & Fixing P.V.C. waste pipe with all fittings complete. |
| 312 | PVC with C.P. Nut 32mm dia |
| 313 | PVC with C.P. Nut 40mm dia |
| 314 | P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge |
| 315 | Size 500x400mm |
| 316 | Providing and fixing Bottle Trap of of approvedmake |
| 317 | C.P. Brass 32 mm |
| 318 | C.P. Brass 40 mm |
| 319 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Geyser etc. |
| 320 | C.P. Inlet connection 15 mm Brass (1S:8931 marked). |
| 321 | P & F Low level Flushing Cistern of 10litrescapacity (IS:2556 mark) of approved makewithcompletefittingsC.I.bracketsdulypainted,brassballcockwithball, (IS:1703 mark) complete including cutting and making good the wall : |
| 322 | PVC with PVC bend as per IS : 7231 |
| 323 | WVC for symphonic EWC. |
| 324 | P & F C.P. brass Urinal Flush pipe set complete with flanged brackets of. Approved make. |
| 325 | For I Urinals. |
| 326 | P & F Extension pipe for bib cocks of approved quality /make: |
| 327 | C.P Brass heavy & superior quality 150 x 15mm |
| 328 | P&F Jet spray for water closet with C.P. copper tube flange of approved make |
| 329 | P & F Toilet Shelf of approved quality/make: |
| 330 | Acrylic shelf on C.P. brass casted brackets & guard rail of commander or equivalentmake size 550 X 125 mm |
| 331 | Providing and fixingSuperior quality (Jaguar Contiental ) CP Brassfittings complete as per direction of EI |
| 332 | Pillar Cock 15 mm nominal size |
| 333 | Swan neck pillar cock 15 mm nominal size |
| 334 | Bib Cock with long thread 15 mm nominal size |
| 335 | Long body Bib Cock 15 mm nominal size |
| 336 | Two way Bib Cock 15 mm nominal size |
| 337 | Angular stop cock with long thread 15 mm nominal size |
| 338 | Sink cock with swinging casted spout (table mounted ) 15 mm nominal size |
| 339 | Central hole basin mixer |
| 340 | Wall mixer 3 in 1 system with provision of tetephonic bath shower with bend pipe |
| 341 | 600 mm long towel rail |
| 342 | Revolving type towel ring |
| 343 | Soap dish |
| 344 | Double coat hook |
| 345 | 190 mm rain shower |
| 346 | Paper holder |
| 347 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-inCharge |
| 348 | P & F water closet Seat Covers with brass hinges complete : |
| 349 | Solid PVC (IS 2548 marked) grade-I White for EWC. |
| 350 | P & F Mixing Range (15 mm) |
| 351 | C.P. One hole/close hole basin mixer with casted spout. |
| 352 | P & F Divertorsof superior quality and approved make: |
| 353 | C.P. brass Tip-tone divertor bath spout with mixing valve. |
| 354 | SupplyandInstallationofGrabBarS,type-304,18-gauge(1mm)stainlesssteel tubing with satin-finish.1-1/2\"(25.4mm) outside diameter. Concealed Mounting Flanges—18-8S,type-304,stainlesssteelplate;endflangeswithtwoholesfor attachmenttowall.SnapFlangeCovers—18-8S,type-304,22-gauge(0.8mm) drawnstainlesssteelwithsatin-finish.Eachcoversnapsovermountingflangeto conceal mounting screws. |
| 355 | SupplyandInstallationofSwingGrabBar18-8S,type-304,18-gauge(1mm) stainlesssteeltubingwithsatin-finish.1–1/4(25mm)outsidediameter.Endsare heliarc welded to flanges.Backplate - 18-8S, type-304,3/16\" (5mm)thick, satin-finishstainlesssteel with four screw holes for attachment to wall. |
| 356 | SOIL, WASTE,VENT AND RAIN WATER PIPES |
| 357 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 358 | 110 mm dia |
| 359 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 360 | Coupler 110mm dia |
| 361 | Bend 87.5 Dg. 110mm dia |
| 362 | Bend 45 Dg. 110mm dia |
| 363 | Door Bend 87.5 Dg. 110mm dia |
| 364 | Double \"Y\" 110mm dia |
| 365 | Socket Plug 110mm dia |
| 366 | Pipe Clip 110mm dia |
| 367 | W.C. Connector 110mm dia |
| 368 | Single Tee 110mm dia |
| 369 | Multi floor trap 110mm dia |
| 370 | Nahni Trap with Jali 4” 110mm dia |
| 371 | Vent Cowel 110mm dia |
| 372 | P&FrigidPVCPipe(IS:4985mark)classII(4Kg./Cm.)approvedquality/make including joining the pipe with solvent cement rubber ring and lubricant |
| 373 | 110mm dia |
| 374 | 160 mm dia |
| 375 | P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincluding joining the pipe with solvent cement rubber ring and lubricant: |
| 376 | 110mm dia |
| 377 | Coupler(socket) |
| 378 | Door Tee |
| 379 | Bend 45 |
| 380 | Door Bend (top side) |
| 381 | Vent Cowel |
| 382 | Pipe clip |
| 383 | WC connector with lipring |
| 384 | WC connector bent type |
| 385 | Multi Floor Trap |
| 386 | Height raiser |
| 387 | Top tile & straine |
| 388 | P-Trap |
| 389 | Gully Trap |
| 390 | 160 mm dia |
| 391 | Coupler(socket) |
| 392 | Door Tee |
| 393 | Bend 45 |
| 394 | Door Bend (top side) |
| 395 | Vent Cowel |
| 396 | Pipe clip |
| 397 | Providing and fixing Grating of approved quality/make: |
| 398 | (-do-) Square 150 x 150 x 8mm. (Anti Cockroach) |
| 399 | Painting (two or more coats) on rain water soil, waste and vent pipes and fitting with blackanticorrosivebitumastic paintofapprovedbrandandmanufactureoverand includinga priming coat of ready mixed zinc chromate yellow primer on new work: |
| 400 | 100 mm dia. pipes. |
| 401 | 150 mm dia. pipes. |
| 402 | ProvidingandlayingLaboratory /hospitalEffluentwastepipeandfittingofhigh densitypolyethelene(HDPE),CLASS-PE80,pressureratingPN-6,conformingtoIS:4427,electricfusionjoints/flangedjoints,fittingswhichincludes bends,,junctions,cowls,offsets,access pieces.etc. complete including jointing. |
| 403 | 50 mm dia |
| 404 | 90 mm dia |
| 405 | 110 mm dia |
| 406 | WATER SUPPLY (Internal & External) |
| 407 | ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittingswithonestepCPVCsolventcementandtestingofjointscompleteasper direction of Engineer in Charge. ( INTERNAL WORK - EXPOSED ON WALL) |
| 408 | 15 mm nominal outer dia Pipes |
| 409 | 20 mm nominal outer dia Pipes |
| 410 | 25 mm nominal outer dia Pipes |
| 411 | 32 mm nominal outer dia Pipes |
| 412 | 40 mm nominal outer dia Pipes |
| 413 | 50 mm nominal outer dia Pipes |
| 414 | ProvidingandfixingChlorinatedPolyvenylChloride(CPVC)pipeshaving thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. |
| 415 | Concealed work including cutting chases and making good the walls etc. |
| 416 | 15 mm nominal outer dia pipes |
| 417 | 20 mm nominal outer dia pipes |
| 418 | 25 mm nominal outer dia pipes |
| 419 | 32 mm nominal outer dia pipes |
| 420 | ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 421 | External Works |
| 422 | 32 mm nominal outer dia pipes |
| 423 | 40 mm nominal outer dia pipes |
| 424 | 50 mm nominalouter dia Pipes |
| 425 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : |
| 426 | 25mm dia, nominal bore |
| 427 | 32 mm dia, nominal bore |
| 428 | 40 mm dia, nominal bore |
| 429 | 50 mm dia, nominal bore |
| 430 | P&FGun-metalNon-returnValveorCheckvalve(IS:Make)ofapprovedmake, superior quality : |
| 431 | 25 mm nominal bore. |
| 432 | Horizontal : |
| 433 | 40 mm nominal bore. |
| 434 | Horizontal : |
| 435 | 50 nominal bore (vertical) |
| 436 | 50 nominal bore (Horizontal) |
| 437 | P & F Stop cock (IS:8931 Mark) superior quality & of approved make |
| 438 | Brass 400 gm. 15 mm nominal bore |
| 439 | P&FPVCStorageTank(IS:12701markedindicatingtheBISlicenseNo.)of approved makewithcover, 25mmdia1 M long. G.I.over-flow pipe& 25Cm: long washoutpipewith:\"plug\"\";&socket,includingmakingconnectionetc.completeof approved design. |
| 440 | 500 litres capacity. |
| 441 | 1000 litres capacity. |
| 442 | 5000 litres capacity. |
| 443 | P & F Water meter IS:779 mark) of approved make: |
| 444 | 25 mm dia. |
| 445 | P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : |
| 446 | Brass wt. 1000 gm, 25 mm |
| 447 | (-do-) wt1000 gm, 32mm |
| 448 | Brass wt1200 gm, 40 mm. |
| 449 | Brass wt2000 gm, 50 mm. |
| 450 | Making connection of G.I. distribution branch with G.I. main including all fitting. |
| 451 | Beyond 25 mm & up to 100 mm dia. |
| 452 | P & F 15 mm. Dia Connection pipe of approved quality/make: |
| 453 | PVC pipe with C.P. Brass nuts up to length 450 mm. |
| 454 | Constructionof chamber in all typeof soil with300 mmthick masonry in Cm1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished withfloatingneatcement,50mmthickM-15gradeC.C.flooring,earthworketc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 455 | Inside size 300x300mm depth upto 0.5m cement concrete cover with frame |
| 456 | Inside size 600x450mm depth upto 0.5m cement concrete cover with frame |
| 457 | -do- depth upto 0.5mtr to 1.0mtr |
| 458 | Supply and installation of Premium quality sluice valve 100mm dia including all fittings as per approved by Engineer in charge |
| 459 | P & F Foot valve of superior quality and approved make with fittings : |
| 460 | CI 50 mm |
| 461 | CI 65 mm |
| 462 | CI 80 mm |
| 463 | S&F RCC Manholes covers with frame of approved make (Light duty) |
| 464 | Size 500mm dia (double seal) |
| 465 | Size 600x450mm |
| 466 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 100 mm Dia. |
| 467 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 150 mm Dia. |
| 468 | SEWARAGE & DRAINAGE |
| 469 | P&FrigidPVCPipe(IS:4985mark)classII(4Kg./Cm.)approvedquality/make including joining the pipe with solvent cement rubber ring and lubricant |
| 470 | 110mm dia |
| 471 | 160 mm dia |
| 472 | Providing Laying & jointing glazed S.W. pipes grade `A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1.1 excavation & refilling of earth inalltypesofsoilupto1.2mdepth,S.W.fittings,includingtestingofjointsetc, complete. |
| 473 | 200mm dia |
| 474 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe.(Excluding cost of pipe) |
| 475 | 150mm dia S.W. Pipe. |
| 476 | 200mm dia S.W. Pipe. |
| 477 | 250mm dia S.W. Pipe. |
| 478 | 300mm dia S.W. Pipe. |
| 479 | 400 dia S.W. Pipe. |
| 480 | P & F Square-mouth gully trap `A` grade (IS :marked) of approved make complete withC.I.grating,frame&CovermasonarychamberinC.M.1:6,100mmthickC.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. |
| 481 | Trap size 150 X 100mm, ferrow cement cover with frame, each internal chamber size300X300mm. |
| 482 | Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete : |
| 483 | 150mm dia Internal. |
| 484 | 200mm dia Internal. |
| 485 | 250mm dia Internal. |
| 486 | 300mm dia Internal. |
| 487 | 450mm dia internal |
| 488 | Constructionofmanholeinalltypeofsoilinnersize90X60Cm.300mmthick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finishedwith floatingneat cement,50mmthickM-15gradeC.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. |
| 489 | Depth upto 0.5mtr |
| 490 | Add extra over item 3.19.1 for every additional 0.10 mtr depth above 0.5 m depth. |
| 491 | Construction of Man hole, in all types of soil inner size 1.5 x 1.2 M, with, 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 gradeC.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design : |
| 492 | Depth upto 1.5mtr |
| 493 | Add extra over item 3.20.1 for every addl. 0.10mtr depth above 1.5m depth. |
| 494 | Constructionof chamber in all typeof soil with300 mmthick masonry in Cm1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished withfloatingneatcement,50mmthickM-15gradeC.C.flooring,earthworketc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 495 | Inside size 450 x 450mm upto depth of 0.5m Cement concrete cover with frame |
| 496 | Inside depth upto 0.5mtr to 1.0mtr-do- |
| 497 | ConstructionofOpenSurfaceDrainwith112mmthickbrickmasonaryinCM 1:4, 110mm thick base concrete 1:5:10, 37mm thick M-15 grade C.C. flooring, 12 mm 1:4 cement plaster on all exposed face of walls including top surface excavation & disposal of earth complete as per approved design/drawing: |
| 498 | 250mm drain 300mm av. Depth |
| 499 | P&F M.S. foot rests in with CM 1:3 standard design in 20mm square MS bar 50mm embedded in wall & 10cm projected out complete. |
| 500 | BOREWELL |
| 501 | Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications.The work would be completed after obtaining sand free water.The tube well should have a throughout bore as per nominal dia of casing pipe : |
| 502 | 200 mm dia Nominal bore. |
| 503 | Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodatehousingandassemblypipeoffollowingsizesinall typesofalluvium strata by percussion / rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I & II) 1979 as amended upto date (the work includes the costofgravel&itsprimarypackingandpackingduringdevelopment,loweringof housing &strainer assembly pipes, withsupply andwrappingof coir rope, wherever necessary, for arresting fine sand particles.The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). |
| 504 | 200 mm Nominal bore. |
| 505 | Development of tube well as per IS specification using suitable compressor to give and free water for required yield of the gravel packed tube well. |
| 506 | Supply of ERW M.S. black casting pipe ISI marked (IS:4270/1992) of grade Fe 410 of following sizes at site of work. |
| 507 | 200 mm nominal bore |
| 508 | Supply of strainer pipes made of ERWM.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. |
| 509 | 200 mm Nominal Bore. |
| 510 | Testing vertically of tube-well by plumbing system and yield test and draw down test by pumping system as per IS:2800 (Part-II) 1979. |
| 511 | S & F tube well cover of tube well cover of M.S. sheet (6mm thick) with nuts and bolts complete for casing size : |
| 512 | 200mm dia. |
| 513 | S & F M.S. clamp, set of 50x6mm flat from ion with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 514 | Supply of 50mm dia G.I. medium class pipe (each length 5.8 m to 6.0 m) tripod as per drawing and design with chain pulley of 3 Mt. capacity. |
| 515 | InstallationofsubmersiblemotorpumpsetinTube-well/openwellcomplete(labour charges only) including transportation of tripod chain pulley black & any other material required for lowering purpose. |
| 516 | Providingand installingsubmersible pump and electrical panel suitable for 200 mm dia casing of bore with SS impeller, high tensile SS shaft, copper wound squirrel cage wet type induction motor 3000 rpm, 415 V, 50 Hz,3 phase A.C. supply, conformingto ISS: 8034-1976, capacity 300-500 LPM at 80-120 m headalong with a directly coupled submersible type squirrel cage electric induction 10 H.P(minimum). motor suitable for operation on 400 V, 3 phase, 50 c.p.s. A.C. supply, water lubricated bearings and provided with pivoted segment type thrust bearings to withstandnon- vertical lead with minimum wear and tear and duly fitted with device to take up the expansion of water with heating of motor, including supply, testing and commissioning of electrical panel from the same manufacturer, complete with all accessories in all respects. The contractor to obtain approval for model and make of pump set & suitable Electrical panel after having yield report of fully developed tube well and submite actual bore strata chart. |
| 517 | including supplying laying and fixing water proof PVC insulated flat submersible cable 3x10 sqmm with end termination with itsaccessories. complete in all respect as required. 1 No. 3 Phase, fully automatic star-delta starter, type - IIof 15 HP with thermal overload relay, contactor, Timer, Push Buttons and Auto-manual selector switch etc complete as required. |
| 518 | RAIN WATER HARVESTING |
| 519 | Constructionoftubewellupto100mdepthandabovetoaccomodatehousingand assemblypipeinalltypesofalluviumstratabyrotaydrillingmethodwith\"codeof practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (PartII) :1979 both amended up to date) with supply of bail plug if necessary.The work willnotincludecostofhousingpipeandstrainerpipeassemblycost,graveland development work. Work would be deemed completed only after obtaining sand free water during pumping. |
| 520 | 200 mm nominal bore |
| 521 | 250 mm nominal bore |
| 522 | Construction of Recharge Shaft in filter pit including Earth work Excavation, lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. |
| 523 | Diameter 900 mm |
| 524 | Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness |
| 525 | Diameter 900 mm |
| 526 | Supply & lowering air line of 25mm dia, G.I. pipe \"B\" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. |
| 527 | Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. |
| 528 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids |
| 529 | Size 9 to 12 mm |
| 530 | Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, withoutdeduction of voids. |
| 531 | EARTH WORK |
| 532 | Excavatingtrenchesofrequiredwidthforpipecables,etc.includingexcavationfor socketsanddressingofsides,rammingofbottoms,depthupto1.5Mtr.including takingouttheexcavatedsoil,andthenreturningthesoilasrequiredinlayersnot exceeding 20 Cm. In depth including consolidating each deposited layer by ramming wateringetc. and disposing of surplus excavatedsoil as directed within a lead of 50 Mtr.: |
| 533 | All Kinds of Soil. |
| 534 | Pipes cables etc. not exceeding 80 mm dia |
| 535 | Pipes cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 536 | Pipes cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
| 537 | Add extra in item No. 1.10 for excavating trench for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 Mtr. but not exceeding 3 Mtr. |
| 538 | Pipes cables etc. not exceeding 80 mm dia |
| 539 | Pipes cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 540 | Pipes cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
| 541 | BSR ITEMS (Rates are based on PWD Electrical BSR 2022) Internal electrical works |
| 542 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 543 | Short point (up to 3 mtr.) |
| 544 | Medium point (up to 6 mtr.) |
| 545 | Long point(up to 10 mtr.) |
| 546 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 547 | Medium point (up to 6 mtr.) |
| 548 | Long point(up to 10 mtr.) |
| 549 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 550 | On board |
| 551 | Short point (up to 3 mtr.) |
| 552 | Medium point (up to 6 mtr.) |
| 553 | Long point(up to 10 mtr..) |
| 554 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 555 | 20 mm |
| 556 | 25 mm |
| 557 | 32 mm |
| 558 | 40 mm |
| 559 | 50 mm |
| 560 | S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 561 | 20 mm |
| 562 | S&F following sizesof ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 563 | 100 mm x 50 mm |
| 564 | 38 mm x 25 mm |
| 565 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 566 | 2 x 1.5 sq.mm |
| 567 | 3x 1.5 sq.mm |
| 568 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 569 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 570 | 4 x 6.0 sq.mm |
| 571 | 4 x 10.0 sq.mm |
| 572 | 1 x 4.0 sq.mm |
| 573 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 574 | 2 x 6.0 sq.mm |
| 575 | 2 x 10.0 sq.mm |
| 576 | 4 x 16.0 sq.mm |
| 577 | Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 578 | RG - 6 |
| 579 | P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 580 | 3.0 mm thick |
| 581 | 6.4 mm thick |
| 582 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 583 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 584 | P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 585 | 63 amp, 5 pin + scrapping Earth, 8 Module |
| 586 | 32 amp, 5 pin + scrapping Earth, 8 Module |
| 587 | Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 588 | Up to 457 mm size |
| 589 | Providing & Fixing of single / multi tone electronic call bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 590 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 591 | 10 A one way switch |
| 592 | 16 A one way switch With LedIndicator |
| 593 | 32 Amp. 2 Moduleswitch With LedIndicator |
| 594 | Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 595 | 6 A3/5 pin shuttered socket |
| 596 | 6/16 Ashuttered socket |
| 597 | 25 Amp. 2 Module Socket |
| 598 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 599 | 5 step fan regulator 2 Module 360 dgree rotating |
| 600 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 601 | T.V. coaxial socket |
| 602 | Blanking plate |
| 603 | Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 604 | Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 605 | Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 606 | 1/2 Module |
| 607 | 3 Module |
| 608 | 8 Module |
| 609 | Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 610 | 1-2 Module |
| 611 | 3 Module |
| 612 | 6 / 8 module |
| 613 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 614 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 615 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of = 110 lm / watt, THD < 10 % , Pf.=0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. |
| 616 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 617 | Surface Mounting (with extruded alumn. Housing ) |
| 618 | Minimum lumen output 1300 lm |
| 619 | Minimum lumen output 1950 lm |
| 620 | Providing & Fixing of IP20, 2\"x2\" LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of = 120 lm/Watt ,THD < 10 % , p.f.=0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. |
| 621 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 622 | Surface Moutning |
| 623 | Minimum lumen output 4200 lm |
| 624 | Providing & Fixing of 400 mm SweepBLDC technology Oscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Double Wall bearing withfront and back 120 or moreribs guard; Three no.blades, noise level should be <= 75 dB,including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 625 | Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM |
| 626 | Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 627 | Wall mounting type with Adjustable Vertical Angle |
| 628 | Providing & Fixing ofof M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed withcement concrete mortar with required support as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 629 | Providing and laying Non Pressure NP-3 classR.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of Earth& Back filling with compaction is to be Paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 630 | 200 mm Dia. |
| 631 | 300 mm dia |
| 632 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 633 | Single pole MCB (With B/C curve tripping Characteristics) |
| 634 | 6 A to 32 A rating |
| 635 | Double pole MCB(With B/C curve tripping Characteristics) |
| 636 | 50/63 A rating |
| 637 | Four pole MCB (With B/C curve tripping Characteristics) |
| 638 | 50/63 A rating |
| 639 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 640 | Two pole 100/300mA sensitivity |
| 641 | 40 A rating |
| 642 | 63 A rating |
| 643 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 644 | Glazed door (single phase) IK-09 and IP-43 with Metal end box |
| 645 | 12 Way (12+2) |
| 646 | Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box |
| 647 | 8Way(Incomer 8,Sub Incomer2+2+2) |
| 648 | 12 Way(Incomer 8,Sub Incomer2+2+2) |
| 649 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 650 | 16.0 Sq. mm |
| 651 | 4 core |
| 652 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArmouredCoppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)includingtesting etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 653 | 6.0 Sq. mm |
| 654 | 4 core |
| 655 | Supplying and makingend termination with heavy duty Copper lugs ( ANY type ) confirming toIS 8337 -1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 656 | 6.0 Sq.mm |
| 657 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 658 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 659 | 4 x 16.0 sq.mm |
| 660 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 661 | 150mm x 50mm x 1.6mm |
| 662 | 300mm x 62.5mm x 2.0mm |
| 663 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 664 | 90 mm |
| 665 | 110 mm |
| 666 | Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 667 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 668 | (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 669 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 670 | (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. |
| 671 | (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 672 | (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 673 | 25 mm thick and 3 Mtr. Long |
| 674 | Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 675 | 32mm x6mm G.I. ( Hot Dipped) Strip |
| 676 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 677 | 8 SWG copper Wire |
| 678 | Providing & Fixing of testing joint, made out of 20mm x 3mm copper Strip, 125 mm long, with 4 no. tinned brass bolts, nuts, checknuts, spring washer etc. complete as required.All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure \"A\" attached with this BSR . |
| 679 | Supply & Laying following size\" B \" class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure \"A\" attached with this BSR . |
| 680 | 32mm dia |
| 681 | 50 mm dia. |
| 682 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 683 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 684 | NON BSR |
| 685 | SITC of LED batten with reliable and robust CRCA housing structure, CRI>80, System Lumen Output of 4100 lm with a System Wattage of not more than 40 Watts and a system efficacy of 100 lm/Watts, Lifetime of 50,000 burning hours @L70, Wide Operating Voltage Range of 140V-270V, Color Temperature Options of 5700K -6500K, Power Factor = 0.95, THD<10% with Short Circuit and over voltage cut off etc as required.LM 79 and LM80 report has to be submitted for documentary verification of above Specifications. (Make Phillips, Havells, Crompton , Wipro, Trilux) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy