Replacement Of Main Distribution Boards ( Mdbs ) , Sub-Distribution Boards ( Sdbs ) And Installation Of Energy Meter Boards ( Embs ) In Estate Residential Quarters At O. F. Badmal.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Feb-2023 | Attachment of Scope of Work | Technical Bid | 20-Mar-2023 |
| 2 | 20-Mar-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Mar-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Replacement of Main Distribution Boards (MDBs), Sub-Distribution Boards (SDBs) and installation of Energy meter Boards (EMBs) in estate residential quarters at O. F. Badmal. |
| 2 | Cutting openings, through brick walls for door , window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to shore and rubbish not exc. 50m. |
| 3 | Providing cement concrete of type C 01:3:6with 12.5 mm graded coarsed aggregate in the left over excavated brick wall of residential quarters for placement of distribution Boards. |
| 4 | Supply and fixing of 415 Volt, 50 Hz, 3 Phase prewiredfactory fabricated metallic CRCA steel sheet enclosure of size (1000 x 1000 x 200) mm and thickness not less than 2mm with dulypainted. It shall have the following provisions:-(i) 10 compartments with locking arrangementfor fixing single phase Energy Meters in 2 rows.The front side of the door shall be of transparent type to record the the meter reading without opening the enclosure.(ii) 5 Compartments with locking arrangement anddin rail for housing MCBfor 3 Phase distribution in a single row just below the 2nd row of energy meter. (iii) Fully color shrouded insulated aluminiumbus bars (For 3 Phase & Neutral) of current carrying capacity not less than 100 Ampere will be provided in the 4th row for distribution of 3 phase supply separately. (iv) Earth bar will be provided vertically aside the line bus bars in the lower most chamber. (v) 2 Studs with complete accessories forEnclosure body earthing.(vi) The bus bar chamber will have single metallic detacheable door.(vii) Wiring with 6 Sq mm multistranded copper wire and colour coding to be followed as per standard practice.(viii) The scope also includes reconnection of incoming as well as outgoing power supply and making good to the surface on completion of work. (ix) It includes removal of existing energy meters from inside the quarters and refixing the same in the proposed enclosure. (x) Removal of existing concealedmain distribution board of size upto (740 x 600 x 220) mm. (xi) Existing RCCBs/MCBs will be re-used for catering of power supply. |
| 5 | Supply and fixing of 415 Volt, 50 Hz, 3 Phase prewiredfactory fabricated metallic CRCA steel sheet enclosure of size ( 750 x 1000 x 200) mm and thickness not less than 2mm with dulypainted. It shall have the following provisions:- (i) 6 compartments with locking arrangementfor fixing single phase Energy Meters in 2 rows.The front side of the door shall be of transparent type to record the the meter reading without opening the enclosure. (ii) 3 Compartments with locking arrangement anddin rail for housing MCBfor 3 Phase distribution in a single row just below the 2nd row of energy meter. (iii)Fully color shrouded insulated aluminiumbus bars (For 3 Phase & Neutral) of current carrying capacity not less than 100 Ampere will be provided in the 4th row for distribution of 3 phase supply separately.(iv) Earth bar will be provided vertically aside the line bus bars in the lower most chamber. (v) 2 Studs with complete accessories forEnclosure body earthing.(vi)The bus bar chamber will have single metallic detacheable door. (vii) Wiring with 6 Sq mm multistranded copper wire and colour coding to be followed as per standard practice. (viii) The scope also includes reconnection of incoming as well as outgoing power supply and making good to the surface on the completion of work. (ix) It includes removal of existing energy meters from inside the quarters and refixing the same in the proposed enclosure. (x) Removal of existing concealedmain distribution board of size upto (740 x 600 x 220 ) mm.(xi) Existing RCCBs/MCBs will be re-used for catering of power supply. |
| 6 | Supply and fixing of 415 Volt, 50 Hz, 3 Phase prewiredfactory fabricated metallic CRCA steel sheet enclosure of size (600 x 1000 x 200) mm and thickness not less than 2mm with dulypainted.It shall have the following provisions:-(i) 4 compartments with locking arrangementfor fixing single phase Energy Meters in 2 rows.The front side of the door shall be of transparent type to record the the meter reading without opening the enclosure. (ii) 2 Compartments with locking arrangement anddin rail for housing MCBfor 3 Phase distribution in a single row just below the 2nd row of energy meter. (iii) Fully color shrouded insulated aluminiumbus bars (For 3 Phase & Neutral) of current carrying capacity not less than 100 Ampere will be provided in the 4th row for distribution of 3 phase supply separately.(iv) Earth bar will be provided vertically aside the line bus bars in the lower most chamber. (v) 2 Studs with complete accessories forEnclosure body earthing.(vi) The bus bar chamber will have single metallic detacheable door.(vii)Wiring with 6 Sq mm multistranded copper wire and colour coding to be followed as per standard practice. (viii) The scope also includes reconnection of incoming as well as outgoing power supply and making good to the surface on the completion of work. (ix) It includes removal of existing energy meters from inside the quarters and refixing the same in the proposed enclosure.(x) Removal of existing 4 way concealedmain distribution board of size upto (200 x 350 x 100) mm. (xi) Existing RCCBs/MCBs will be re-used for catering of power supply. |
| 7 | Supply and fixing of 415 Volt, 50 Hz, 3 Phase prewiredfactory fabricated metallic CRCA steel sheet enclosure of size (600 x 750 x 200 ) mm and thickness not less than 2 mm with dulypainted. It shall have the following provisions:- (i) 2 compartments with locking arrangementfor fixing single phase Energy Meters in 1 row.The front side of the door shall be of transparent type to record the the meter reading without opening the enclosure.(ii) 2 Compartments with locking arrangement anddin railfor housing MCBs for 3 Phase distribution in a single row just below therow of energy meter.(iii)Fully color shrouded insulated aluminiumbus bars (For 3 Phase & Neutral) of current carrying capacity not less than 100 Ampere will be provided in the lower most row for distribution of 3 phase supply separately. (iv) Earth bar will be provided vertically aside the line bus bars in the lower most chamber.(v) 2 Studs with complete accessories forEnclosure body earthing.(vi) The bus bar chamber will have single metallic detacheable door.(vii) Wiring with 6 Sq mm multistranded copper wire and colour coding to be followed as per standard practice. (viii) The scope also includes reconnection of incoming as well as outgoing power supply and making good to the surface on the completion of work.(ix) It includes removal of existing energy meters from inside the quarters and refixing the same in the proposed enclosure.(x) Removal of existingdistribution board of size upto 740mm x 660mm x 190mm.(xi) Existing RCCBs/MCBs will be re-used for catering of power supply. |
| 8 | Supply and fixing of 240 Volt, 50 Hz, Single Phase prewiredfactory fabricated metallic CRCA steel sheet enclosure of size (600 x 750 x 200) mm and thickness not less than 2 mm with dulypainted. . It shall have the following provisions:- (i)2 compartments with locking arrangementfor fixing single phase Energy Meters in 1 row.The front side of the door shall be of transparent type to record the the meter reading without opening the enclosure.(ii) 2 Compartments with locking arrangement anddin railfor housing MCBs for 3 Phase distribution in a single row just below therow of energy meter. (iii)Fully color shrouded insulated aluminiumbus bars (For Single Phase & Neutral) of current carrying capacity not less than 100 Ampere will be provided in the lower most row for distribution of Single phase supply separately. (iv) Earth bar will be provided vertically aside the line bus bars in the lower most chamber. (v) Studs with complete accessories for enclosure body earthing.(vi)The bus bar chamber will have single metallic detacheable door.(vii)Wiring with 6 Sq mm multistranded copper wire and colour coding to be followed as per standard practice.(viii) The scope also includes reconnection of incoming as well as outgoing power supply and making good to the surface on the completion of work. (ix) It includes removal of existing energy meters from inside the quarters and refixing the same in the proposed enclosure.(x) Removal of existing 4 way distribution enclosure.(xi) Existing RCCBs/MCBs will be re-used for catering of power supply. |
| 9 | Supply & fixingof duly painted 240 Volt, 50 Hz 8 wayprewired single phase modular double door distribution board of approx. size(260 x 240 x 90) mm suitable for recess mounting with thickness of sheet not less than 1.6 mm. It shall have the following provisions:- (i)Earth Bar, fully shrouded Neutral Bar andties for cable management.(ii) MCBs shall be operable manually without opening the inner door.(iii) Studs for body earthing connection. (iv) DIN rail for mounting MCBs & metallic link for MCBs .(v) The scope includes removal of existing concealeddistribution board of size (450 x 620 x 200) mm. (vi) Reconnection of incoming as wellas outgoing power supply.(vii)Existing RCCBs/MCBs will be re-used for catering the power supply. (viii)The DB specifications shall be as per IEC 61439-3 or IS/BIS standards.Make:-Preferably Shall be ofLegrand/V-Guard/Havells or Equivalent Reputed Make. |
| 10 | Supply & fixingof duly painted 240 Volt, 50 Hz 4 wayprewired single phase modular double door distribution board of approx. size( 100 x 100 x 90 ) mm suitable for recess mounting with thickness of sheet not less than 1.6 mm. It shall have the following provisions:-(i)Earth Bar, fully shrouded Neutral Bar andties for cable management.(ii)MCBs shall be operable manually without opening the inner door.(iii)Studs for body earthing connection. (iv)DIN rail for mounting MCBs & metallic link for MCBs .(v)The scope includes removal of existing surface mounted wooden distribution board of approximate size 380 mm x 350mm x 60 mm.(vi)Reconnection of incoming as well as outgoing power supply.(vii) Existing RCCBs/MCBs will be re-used for catering of power supply. (viii)The DB specifications shall be as per IEC 61439-3 or IS/BIS standards. Make:-Preferably Shall be ofLegrand/V-Guard/Havells or Equivalent Reputed Make. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender