}

Tender For Repair To Summer Appliances Under Ge(North) Patiala, patiala-Punjab

Military Engineer Services-MES has published Tender For Repair To Summer Appliances Under Ge(North) Patiala. Submission Date for this Tender is 24-03-2023. Air Conditioner Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36484121
Corrigendum : Tender For Repair To Summer Appliances Under Ge(North) Patiala
Open Tender
Indian
Punjab
patiala
24-03-2023

Tender Details

Repair To Summer Appliances Under Ge ( North ) Patiala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO SUMMER APPLIANCES UNDER GE(NORTH) PATIALA.
Sl. No. Item Description
1Dismantling and lowering to ground for repair, inspecting defective of Window/Splittype AC of capacity 1.5 and 2 Tonand re-installing the same after repair complete, testing and shifting to new locations if required as specified by Engr-in-Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. 3. Decision of Accepting Officer will be final in case of fine payment
2Supply and replacement of compressor sealed unit suitable for Window TypeACs 1.5 Ton Capacity , reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh/LG
3Supply and replacement of compressor sealed unit suitable for Window TypeACs 1.5 Ton Capacity , Rotarytypeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh
4Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacityreciprocating typeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh
5Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity, rotarytypeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh
6Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh
7Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as directed. Make- Kirloskar/ Godrej/Tecumseh
8Material and labour forcharging of gas in window type AC 1.5/2 Ton ( R-22/ R410A)after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete as directed.
9Material and labour forcharging of gas in split type AC 1.5/2 Ton ( R-22/ R410A)after flushing, vaccumising and dehydration as per laid down standard practice and existing modelincluding replacement of strainer complete as directed.
10Servicing of Air conditioners of window/ split type of any capacity 1.5/ 2 Ton by removing dirt and debries on all parts of air conditioner, washing and lubricating all moving parts complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. Note : 1. Lowering, dismantling, re-installing of air conditioners after reassembling the equipment in same/different position shall be included in the unit quoted rate. 2. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints.3. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint 4. Decision of Accepting Officer will be final in case of fine payment
11Servicing of Air conditioners of window/ split type of any capacity 1.5/ 2 Ton Located at ATC Building at 660 AOPby removing dirt and debries on all parts of air conditioner, washing and lubricating all moving parts complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. Note : 1.Lowering, dismantling, re-installing of air conditioners after reassembling the equipment in same/different position shall be included in the unit quoted rate. 2. Contractor is advised to ascertain the position of different ACs located at site where servicing is to be done. Approximate Height of ATC Building is 18 meters 3. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints.4. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.5. Decision of Accepting Officer will be final in case of fine payment
12Supply only Front grill of window type AC with shutters as per existing model complete all specified and directed by Engineer-in-charge.
13Supply only 1/2"" and 1/4"" reverse valve for split AC valve as per existing model complete all as specified and directed by Engineer-in-charge.
14Supply only suction valve size 3/8"" for 1.5/2 TR split AC complete all as specified and directed by Engineer-in-charge.
15Supply only delivery valve size 1/2"" for 1.5/2 TR split AC complete all as specified and directed by Engineer-in-charge.
16Supply only swing motor for 1.5/2 TR split AC indoor unit for any existing make complete all as specified and directed by Engineer-in-charge. Make: Carrier/LG/samsung/daikin
17Supply and replacement of double shaft blower motor of size 1/10 HP for window Air Conditioner of capacity 1.5 Ton single phase 230 V, 1500 rpm complete all specified and directed by Engr-in-charge. Make- Crompton/Kirlosker suitable for AC of make fedder Lloyd/ Blue Star/ LG/ Carrier/Samsung
18Supply and replacement of indoor/blower motor of size 1/10 HP for split Air Conditioner of capacity 1.5 Ton as per existing model of approved make complete all as specified and directed by Engineer-in-charge.
19Supply and replacement of Fan motor for split typeAir Conditioner of capacity 1.5/2.0 Ton as per existing model complete all as specified and directed by Engineer-in-charge.
20M&L for rewinding of blower motor double speed (high & low) with supper enamelled copper wire of proper gauge with and including rubber bush of capacity1/10 HP motor complete all as specified and directed by Engineer-in-charge.
21Supply and fix Rolling type PVC Blower for indoor unit of split AC 1.5 / 2.0 Ton Capacity Make as per existing complete all as specified and directed by Engineer-in-charge.
22Supply and fix Fan Blade for out door unit of split AC 1.5 /2.0 Ton Capacity make as per Existing complete all as specified and directed by Engineer-in-charge.
23Supply and fix as in replacement flexible copperconductor cable 3 core, PVC insulated of size70/.0076 and connected electrically to any electric devices/ofanycapacity sizetype & make etc complete all as specified and directed. Make:KEI,Plaza,Kalinga,Havells
24Supply and Replacement of capacitor 6 mfd 230volts (+) 5% dry type complete suitable for window /split Ac motorscomplete all as specified and directed. Make: Tibcon/Elcap or equivalent.
25Supply and replacement of running capacitor 36 mfd complete all as specified and directed. Make-TIBCON/SIEMENS or equivalent.
26Supply and replacement of running capacitor 45/50 mfd complete all as specified and directed. Make-TIBCON/SIEMENS or equivalent.
27Supply and replacement of starting capacitor of size 100-120 MFD for Air Conditioner up to 2 Ton Capacity complete all as specified and directed. Make-TIBCON/SIEMENS or equivalent.
28Supply and replacement of starting capacitor of size 80-100 mfd complete all as specified and directed.Make-TIBCON/SIEMENS or equivalent.
29Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by GE complete all as specified and directed. Make- MICROTECH/ HITECH or Equivalent.
30Supply and replacement of PCB assembly of existing make for window type ACs 1.5 to 2.0 tonwith remote control complete all as specified and directed.
31Supply and replacement of PCB assemblyof existing make for split type ACs 1.5 to 2.0 tonwith remote control complete all as specified and directed.
32Repair of PCB assembly of existing make for invertor AC complete all as specified and directed by Engr-in-charge.
33Supply and fix indoor motor of Invertor AC of existing make complete all as specified and directed.
34Supply and replacement of fan blade of window ACs of cap 1.5 to 2.0 ton complete all as specified and directed.
35Supply and fix in replacement new Biometal in Window/Split AC 1.5/2 Ton complete all as specified and directed.
36Dismantling and lowering to ground for descaling of condenser with appropiate chemical towindow/split typeACsof capacity 1.5 and 2 Tonand re-installing the same it original position testing complete all as specified and directed.
37Dismantling and lowering to ground for repair of condenser with appropiate welding/ brazing, installing new condenser fins copper type for Window/splitACsof capacity 1.5 Tonand re-installing the same it original position testing complete all as specified and directed.
38Dismantling and lowering to ground for repair of condenser with appropiate welding/ brazing, installing new condenser fins copper type for Window/splitACsof capacity 2 Tonand re-installing the same it in original position testing complete all as specified and directed.
39Supply and fix PVC enclosures, single pole and neutral with a two pin and earth plug and socketed complete with one single pole MCB,s capacity 32 Amp /40 Amp 240Volts complete all as specified and directed.
40Supply only Thermostat switch 2059/2064/2054 for Window / Split type AC unit of cap 1.5 ton/ 2 ton complete all as specified and directed.
41Supply only Copper filter double capillary pencil type for window/split type AC of cap 1.5 ton/ 2 ton complete all specified and directed.
42Supply only wiring kit for AC window/Split type 1.5/2 Ton complete all specified and directed.
43Supply only remote control hand set for existing Window type/ split type air conditioner of make LG/Samsung/Voltas/Bluestar and of cap 1.5/2 ton with required pencils cells as per sample complete all as specified and directed.
44Supply only AC contactor single phase 230 Volt, 50 Hz, double pole, AC3 rating 25 Amp/32 Amp complete all as specified and directed.
45Supply only air filter made of Ric/ Nylon suitable for split/ window type AC 1.5/2 TR cap complete all as specified and as directed . Make: Samsung/LG/Voltas/carrier.
46Supply and replacement PVCpipe flexible type 20mm dia (including flexible clamps)for drain out waste water from split Acs complete all as specified and as directed.
47Carrying out pressure leak test for 1.5/2 ton capacity window/split type AC by Nitrogen gas pressure for detecting the leakage in condensing & cooling unit, referigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing, flushing out nitrogen gas, vaccumisation complete all as specified and directed.
48Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 1.5 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitors, relay condensing/ outdoor motor with blade complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier
49Supply and fix in renewal defective indoor unit of 1.5 TR capacity split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
50Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 2 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay condensing/ outdoor motor with blade complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier
51Supply and fix in renewal defective indoor unit of 2 TR capacity split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
52Dismantling and lowering to ground for repairs inspecting defects of water coolers of capacity 40/120/150 litres with cleaning, oiling greasing of all required parts etc and re-installing the same after repair and testing to the complete satisfaction of Engineer -in - Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. 3. Decision of the Accepting Officer will be final in case of fine payment
53Supply and replacement of compressor sealed unit forwater cooler of size 40/80 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as specified and as directed. Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
54Supply and replacement of compressor sealed unit forwater cooler of size 120 and 150 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as specified and as directed. Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
55Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 40/80 litres after satisfactory vacuum and pressure including replacement of strainer & testing complete all as specified and as directed.
56Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 120/150 litres after satisfactory vacuum and pressure including replacement of strainer & testing complete all as specified and as directed.
57Supply and fixing of push cock 15 mm CP size for water coolers as per existing shape and size complete all as specified and as directed.
58Supply and replacement offan motor of condenser size 1/35 HP single phase 50 HZ 230 Volts for water cooler of capacity 40/80 Litre complete with blade as per existing model and connecting items complete all as specified and as directed.
59Supply and replacement offan motor of condenser size 1/10HP single phase 50 HZ 230 Volts for water cooler of capacity 120/150 Litre complete with blade as per existing model and connecting items complete all as specified and as directed.
60Supply and replacement of relay for water cooler with OLP complete all as specified and as directed.
61Supply and replacement of Box type relay with OLP complete all as specified and as directed.
62Supply and replacement of running capacitor 10 mfd complete all as specified and as directed.
63Supply and replacement of running capacitor 15 mfd complete all as specified and as directed.
64Supply and replacement of running capacitor 36mfd complete all as specified and as directed.
65Supply and replacement of PVC float Valve suitable for 15 mm bore pipe (ISI marked) complete suitable for water coolers/desert coolersas per existing at site complete all as specified and as directed.
66Supply and replacement of thermostat switch of water cooler complete all as specified and as directed.
67Supply and replacement of starting capacitor 40/60 mfd 230 volts complete all as specified and as directed.
68Cutting the rusted unserviceable base of 120/80/40 litre capacity, water cooler body, material and labour for fabrication of new base made of MS sheetand angle iron as per existing size and thickness including welding of small patches complete all as specified and as directed.
69Supply and fix in renewal, condensing coil for water cooler capacity 40/80 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
70Supply and fix in renewal, condensing coil for water cooler capacity 60/120 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
71Supply and fixing in replacement of complete top door made out of stainless steel 20 gauge sheet with handle and locking arrangement with double keys including door gasket, insulating material, PVC inner sheet of suitable thickness for 120/40 ltrs capacity water cooler as per existing size and shape, welding work, nuts, bolts and washers complete all as specified and as directed.
72Supply and fix in replacement of 900mm long PVC connections 15mm dia bore with PTMT nuts complete all as specified and directed.
73Material and Labour for detecting any leakage from cooling and condensing coil fin of water cooler capacity 40/80 L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit complete all as specified and directed.
74Material and Labour for detecting any leakage from cooling and condensing coil fin of water cooler capacity 120/150L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit complete all as specified and directed.
75Material and Labour fornew water tank of 40/80 L cooling capacity including all outer side puffing for insulation complete all as specified and directed.
76Material and Labour fornew water tank of 60/120 L cooling capacity including all outer side puffing for insulation complete all as specified and directed.
77Supply only rubber waste pipe/ drain pipe with clamps suitable for water cooler of any capacity complete all as specified and directed.
78Disconnecting and complete opening of voltage stabilizer of capacity up to 5KVAand removing the burnt out unserviceable parts and cleaning, material and labour for new parts, Rewinding with copper enamelled wire as per existing gauge complete all as specified and directed.
79Material and Labour for Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizers of capacity up to 2 KVA complete all as specified and directed.
80Material and Labour for Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizers of capacity of3 to 5KVA complete all as specified and directed.
81Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 2 KVA complete all as specified and directed.
82Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 3 to 5 KVA complete all as specified and directed.
83Supply and replacement of cut out relay of suitable for up to 2 KVA complete all as specified and directed.
84Supply and replacement of cut out relay of suitable for 3 to 5 KVA complete all as specified and directed.
85Supply and replacement of Voltmeter for voltage stabilizer suitable for 3 to 5 KVA complete all as specified and directed.
86Supply and replacement ofcopper pipe heavy duty of size 5/8" complete all as specified and directed.
87Supply and replacement ofcopper pipe heavy duty of size 3/8" complete all as specified and directed.
88Supply and fixing pipe insulation for copper pipe of size 5/8" and 3/8" complete all as specified and directed.
89Supply and replacement ofPVC Hose Pipe flexible type with clamp 25mm dia for ( including flexible clamps)drain out waste water from water cooler complete all as specified and directed.
90S&F Top Plug3 Pin 5 Amps 230 Volts complete all as specified and directed.
91S&F Top Plug3 Pin 15 Amps 230 Volts complete all as specified and directed.
92Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220Ltr cap with and including supplying and charging of gas and including welding/soldering for leak proof as required and commissioning complete all as specified and directed. Make Kirloskar/Tecumseh/LG/Godrej/Whirlpool.
93Supply and replacement of compressor sealed unit for refrigerator of size 270 to 310 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed. Make Kirloskar/Tecumseh/LG/Godrej/Whirlpool.
94Supply and replacement of startingbox type relay PVC 1/8 HP suitable for any make Refrigerator of size 165 to 310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS/HITECH)
95Supply and replacement of startingbox type relay PVC 1/6 HP for Refrigerator of size310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS/HITECH)
96Supply and replacement of over load protector 1/6 HP for Refrigerator of size 310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS/HITECH)
97Supply and replacement of PCB assemblyof existing make for referigerator of capacity 190 Ltr as per existing make complete all as specified and directed.
98Supply and replacement of PCB assemblyof existing make for referigerator of capacity 310 Ltr as per existing make complete all as specified and directed.
99Supply and replacement of PTC relay ofRefrigerator of 286/ 310 Lts complete all as specified and directed.(Make Godrej /Whirlpool)
100Supply and replacement ofrefrigerantgas in the refrigerator & Deep Freezerincluding satisfactoryleak proofand vacuum test of capacity 286 to 310 ltr including replacement of strainer as per existing model complete all as specified and directed.
101Supply and replacement ofrefrigerantgasin the refrigerator & Deep Freezerincluding satisfactoryleak proofand vacuum test of capacity 165 to 220 ltr including replacement of strainer as per existing model complete all as specified and directed.
102Supply and replacement ofFreezer with door frame of refrigerator capacity 165 to 220 ltrs complete all as specified and directed.
103Supply and replacement ofFreezer with door frame of refrigerator capacity 286 to 310 ltrs complete all as specified and directed.
104Supply and replacement of complete condenser assembly of refrigerator suitable for 286 to 310ltrs of existing make complete all as specified and directed.
105Supply and replacement of complete condenser assembly of refrigerator suitable for 165to 220ltrs of existing make complete all as specified and directed.
106Supply and fix in renewal of copper capillary for referigerator of any capacity as per existing make complete all as specified and directed.
107Supply and fix in renewal of Biometal in referigerator of capacity 165 to 310 ltr as per existing model complete all as specified and directed.
108Supply and replacement of door gasketsof refrigerator capacity 165 to 310 ltrs of existing make complete all as specified and directed.
109Supply and fixing Timer for Refrigerator of Cap 286 to 310 Lts complete all as specified and directed.
110Supply and replacement of fan motor of freezer of refrigerator 165ltr to 310 ltr complete all as specified and directed.
111Supply and laying tube medium grade galavinized 15mm bore including all fittings laid in trenches/fixed with wall /in flooring all as specified and directed.
112Supply and replacement of fan motor of deep freezer 220 & 320 lts complete all as specified and directed.
113Supply and fix door gasket suitable for 220/320 ltr deep freezer doors complete all as specified and directed
114Supply and fix starting relay ISI marked for Deep freezer of capacity 220/320 ltr complete all as specified and directed
115Supply and fix OLP ISI marked forDeep freezer of capacity 220/320 ltr complete all as specified and directed
116Supply and fix thermostat ISI marked for deep freezer of capacity 220/320 ltr complete all as specified and as directed
117Supply only starting capacitor 60-80 mfd ISI marked for deep freezer of capacity 220/320 Ltr complete all as specified and directed. Make: Asian/Sharda/unistar/tesla/epcos.
118Supply only running capacitor 36 mfd ISI marked for deep freezer of capacity 220/320 Ltr complete all as specified and directed. Make: Asian/Sharda/unistar/tesla/epcos.
119Supply and replacement of fan blade of referigerator of capacity 165 ltr to 310 ltr complete as specified and directed.
120Supply and replacement of fan blade of Deep freezer of capacity 220 ltr complete as specified and directed.
121Supply and replacement of compressor sealed unit for Deep Freezer of 220/320 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed by EIC. Make Kirloskar/Tecumseh/LG/Godrej/Whirlpool.
122Supply and fix in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pippe 15 mm dia bore including complete all as specified by and directed by Engr-in-charge.
123Servicing of Water purifier of any description complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. (Unserviceable spares shall be measured and paid separately) :- Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint 3. Decision of Accepting Officer will be final in case of fine payment
124Supply and Replacement of Candle/spun filter of RO water purifier complete as specified and directed.
125Supply and Replacement of inline Carbon filter for RO water purifier complete as specified and directed.
126Supply and Replacement sediment pre filter for RO water purifier complete as specified and directed.
127Supply only PVC pipe 1/4" dia for inlet / outlet water connection for RO water purifier complete as specified and directed.
128Supply and fix Suction/delivery RO motor complete as specified and directed.
129Supply and fix RO booster pump as per existing sample complete as specified and directed.
130Supply and fix RO membrane as per existing sample complete as specified and directed.
131Supply and fix SMPS adaptor for RO purifier as per existing make complete as specified and directed.
132Supply and fix RO Flow restrictor RO valve as per existing sample as specified and directed.
133Supply and fix solenoid valve for RO purifier as per existing make complete as specified and directed.
134Supply and fix RO filter tap as per existing make complete as specified and directed.
135Supply and fix RO Pre filter bowl as per existing make and model complete as specified and directed.
136Inspection visit of technical team for AC system comprises of Air cooled condensing unit of cap 11 TR qty 04 Nos. & Air handling units of Cap. 3000 CFM qty 02 Nos Following is included in the visit: 1. Servicing of the complete AC system including cleaning of Pre filters, fine filters and Hepa filters 2. The compressor and AHU will be checked for its proper functioning with electrical connections and if any defect is found, the same is to be informed. 3. Safety controls such as pressure cut outs will be tested with necessary tools and equipments for proper functioning and in case of any mal- functioning same need to be rectified after consultation with EIC. 5.Inspection of Electrical cabling, Electrical switch boards and electrical accessories connected with main incomer to the system and minor repairs in electrical panels to be done as directed and specified by EIC.
137AHU components Air handling units of Cap. 3000 CFM qty 02 Nos exhaustive servicing including refrigerant coil/cooling coil cleaning, AHU coil cleaning, checking for any loose electrical connections, changing of thimbles etc if required separating the components and cleaning with vacuum cleaner and by using antibacterial/ antimicrobial solution. Lubricate and grease motor and blower bearing and Reassemble the components thereafter complete as specified and directed. Note: Each job includes cleaning of 2 AHU units.
138Air Cooled 11 TR Condensing units ( 4 units) exhaustive servicing including coil cleaning with vacuum cleaner and by using antimicrobial solution , electrical connection inspection and cleaning of fan blades and repair and maintenance of fan motor etc complete as specified and directed. (Note : 1 job includes cleaning of all four condenser units of 11 TR)
139Replacement of coarse air Prefilters of size 600 x 600 x 50 mm. Coarse filter will be G4 washable filter ( 50mm deep) class having average arrestance of 85-98% for 10 microns size as per EN779 2002, after damper at mouth of supply complete as specified and directed.
140Replacement of fine filters bag type fine filters of size 600 x 600 x 300mm. Fine filters will be F-7 filters (300 mm deep) Average effieciency 85-95% for 1 micron size as per EN 779 2002 standards complete as specified and directed.
141M & L for removing of damaged portion of duct insulation and fixing new nitrile thermal insulation of thickness 15 mm for duct with aluminium laminated closed cell elastomeric insulation of thickness 9 mm for supply duct at AHU and exhaust duct at discharge, thereby making the duct surface free from dust etc using a thin film of insulation material all as per manufacturer"s recommended adhesive. Both duct and insulation, keeping the insulation material under compression( without any stretching), seal all joints air tight etc complete all as specified and as directed.
142Supply and replacement ofline operated 3 phase AC motor IE2 of capacity 3.7 KW/ 5HP feq = 50+-5% Hz, IP 55 suitable for AHU operation at central AC Plant completeincluding necessary fitting & connection. CAT ref : MHCITGS+E154X7. Note: Contractor is advised to visit site to ascertain the specifications of AC motor as specified by EIC. Make: Havells ( existing make)
143Rewinding of existing line operated 3 phase AC motor of capacity 3.7 KW/ 5 HP feq 50+-5%, IP 55 and removing the burnt out unserviceable parts and cleaning, material and labour for new parts, Rewinding with copper enamelled wire as per existing gauge complete all as specified and directed by EIC. (Make:Havells ( existing make)
144Supply & installation of Calcium dryer as per existing make complete as specified and directed.
145Supply & installation of HEPA filters of size 880 x 610 x 150 mm as per existing make complete as specified and directed.
146Supply & installation of HEPA filters of size 610 x 610 x 200 mm as per existing make complete as specified and directed.
147Supply & installation of V Belts for AHU blower as per existing make complete as specified and directed.
148Supply and fix AC Contactor of 32 Amp as per existing make CAT No. MNX-A2 complete as specified and directed.
149Supply andfix MCB 3 pole 25 Amp as per existing make complete as specified and directed.
150Supply & charging of refrigerant R407c along with pressure testing with nitrogen & vaccum complete with all respect including rectification of leakage by welding as directed by Engr-in-charge
151Supply and charging of Referigerant R 22 in central AC plant withpressure testing with nitrogen and vaccum complete with all respect including rectification of leakage by welding as specified and directed by Engr-in-charge.
152Supply and fix service valve as per existing make complete as specified and directed.
153Supply and fix Teflon Gasket as per existing make complete as specified and directed.
154Note for Item No. 136 to 153 herein above: Above items from Sr no 136 to 153 pertains to AC system installed at ICU in MH Patiala; The Bidder is advised to visit the plant prior quotation for checking of specification of existing AC Plant components incl AHU, Condensing Units, filters, electrical panels etc.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail