Tender For Maintenance Of Electrical Installation Fans Including Pump Set Compound Lighting Etc At Dte Staff Qtrs At Sawan Park Delhi Sh Moei Rmo Pump Sets, Delhi-Delhi

Public Works Department-PWD has published Tender For Maintenance Of Electrical Installation Fans Including Pump Set Compound Lighting Etc At Dte Staff Qtrs At Sawan Park Delhi Sh Moei Rmo Pump Sets. Submission Date for this Tender is 04-03-2023. clocks Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36481828
Tender For Maintenance Of Electrical Installation Fans Including Pump Set Compound Lighting Etc At Dte Staff Qtrs At Sawan Park Delhi Sh Moei Rmo Pump Sets
Open Tender
Indian
Delhi
Delhi
04-03-2023

Tender Details

Tender For Maintenance Of Electrical Installation Fans Including Pump Set Compound Lighting Etc At Dte Staff Qtrs At Sawan Park Delhi Sh Moei Rmo Pump Sets -Round The Clock Operation & Maintenance I / C Attending And Rectifying Complaints Of All Electrical Installations I / C Compound Light & Drinking Water Supply Pump Etc. Installed In The Campus In All Working Days Including Sundays And Holidays By Providing Following Staff Etc. As Required ( A ) Wiremen Cum Pump Cum E&M Operator- 1 Nos In Each Shift ( B ) Khallasi-1 Nos -In General Shift And As And When Required 2 Supplying & Fixing Of Following Electrical Accessories Suitable For Existing Different Type Fitting / Switch Box I / C Testing Etc. As Required. ( Labour Already Included In Item No. 1 ) A ) S.P. 5 / 6 A, One Way Modular Switch, Isi Marked 3 B ) S.P. 15 / 16 A, One Way Modular Switch, Isi Marked 4 C ) 3 Pin 5 / 6 A Modular Socket Outlet, Isi Marked 5 D ) 6 Pin 15 / 16 A Modular Socket Outlet, Isi Marked 6 E ) Stepped Type Modular Fan Regulator ( 2 Module ) 7 F ) S.P. 5 / 6 A, One Way Switch, Piano Type Isi Marked 8 G ) S.P. 15 / 16 A, One Way Switch, Piano Type Isi Marked 9 H ) 3 Pin 5 / 6 A Socket Outlet, Piano Type Isi Marked 10 I ) 6 Pin 15 / 16 & 5 / 6 A Socket Outlet, Piano Type Isi Marked 11 J ) Bell Push, Piano Type 12 K ) Pvc Batten / Angle Holder 13 L ) 1 Or 2 Module Cover Plate 14 M ) 3 Module Cover Plate 15 N ) 8 Module Cover Plate 16 O ) 12 Module Cover Plate 17 P ) Step Type Fan Regulator ( Socket Type Piano ) 18 Supplying & Fixing Of 3Mm Thick Phenolic Laminated Sheet On Existing Switch Board, Loose Wire Box Making Holes Etc As Reqd. 19 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A ) Group-B 20 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.A ) Group-A 21 B ) Group-B 22 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Requireda ) 3 X 1.5 Sq. Mm 23 B ) 3 X 4 Sq. Mm 24 C ) 3 X 6 Sq. Mm 25 Supplying And Fixing Of Following Sizes Ofsteel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Requireda ) 20 Mm 26 B ) 25 Mm 27 Supplying And Fixing Metal Box Of 150 Mm X 75 Mm X 60 Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5 / 6 A Socket Outlet And 5 / 6 A Piano Type Switch, Connections, Painting Etc. As Required. 28 Supplying And Fixing Metal Box Of 180 Mm X 100 Mm X 60 Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Socket Outlet And 15 / 16 A Piano Type Switch, Connections, Painting Etc. As Required. 29 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 30 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 31 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, “C” Curve Including Connections, Testing Etc. As Required. 32 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required.A ) 180 Mm X 100 Mm X 60 Mm Deep 33 B ) 200 Mm X 250 Mm X 75 Mm Deep 34 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) A ) 12 Way, Double Door 35 Supplying And Fixing Cable End Box ( Loose Wire Box ) ( Ip 43 ) Suitable For Following Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required.A ) For 12 Way, Double Door Spn Mcbdb 36 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) Single Pole 37 B ) Single Pole And Neutral 38 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.A ) 100 A, 16 Ka, Tpmccb 39 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required.A ) 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 40 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required.A ) Upto 35 Sq. Mm 41 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. A ) Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 42 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required 43 Supplying, Installation, Testing And Commissioning Of Pre-Wired, Indoor Led Batten With Extruded Aluminium Housing & Opal Diffuser. Ip20 Of Following Types Suitable For Cool Day-Light Having Cct ( 5700K To 6500K ) , Power Factor >0.90, Cri > 75 ( Including Dismantling The Old Fitting If Any Wherever Required ) & Minimum Lumens Output Should Be > 90 Lumens Per Watt. With All Accessories Etc. Directly On Ceiling / Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. B ) 1X20 Wattsled Batten Fitting. 44 Supplying & Fixing Of Decorative, Wall Mounting, Brushed Nickel / Ss Finish Fixture With Opal Glass Diffuser Suitable For 9 W Led Lamp B22 Base I / C 9 W Led Lamp Complete With Connection Testing Commissioning Etc As Reqd. 45 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Star Rated, Ceiling Fan, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing With 1.5 Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable Etc Complete As Required. 46 Supplying And Installation Of Heavy Duty Exhaust Fan Of 300 Mm Sweep 900 Rpm In The Existing Opening, I / C Making The Hole Suitable The Size Of The Above Fan Making Good The Damage, Connection Testing Commisioning With 1.5 Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Reqd. 47 Supplying & Fixing Aluminium Louvers / Shutters Complete With Frame Suitable For 300 Mm Sweep Exhaust Fan Etc As Reqd. 48 Rewinding Of 1200 / 1400 Mm Ceiling Fan With Suitable Size Super Enamelled Copper Wire After Dismantling From The Existing Position And Refixing The Same On The Existing Position / Ceiling With Suitable Size Nut, Bolts, Cotter Pin, Rubber Reel And Replacement Of The Same Wherever Found Defective During Inspection For Safe Running Of Fan And Cleaning The Fan And Fan Blade With Detergent And Making Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor Wire, Testing And Commissioning Etc. Complete As Required And Buy Back The Dismantled Material. 49 Dismentling, Overhauling & Reinstallation Of Existing Ceiling Fan Complete With Cleaning, Greasing, Replacement Of Bush, Suitable Ball Bearing, Split Pin, Nuts And Bolts, Etc With Test Run I / C Credit Of Dismentle Materials Etc As Reqd. 50 Replacement Of Defective Ball Bearing In The Existing Ceiling Fans I / C Greasing Complete Etc. As Reqd.A ) 6201 51 B ) 6202 52 Sitc Of Pole / Wall Mounted Box ( 300X200x105 ) Mm Size Made Out Of ( Smc ) Sheet Moulding Compound Dust & Weather Proof With Front Openable Hinged Type Cover With Locking Arrangement I / C Providing & Fixing Of Following Accessories On Existing Pole / Wall With Suitable Arrangement As Required.A ) 32 Amp 5 Way Connector With Backelite Base.B ) 6 Amp Sp Mcb C Curve ( 10 Ka ) - 1 No.C ) Earth Studs - 2 Sets.D ) 40 X 5 Mm Clamp With 2 Nos. 3 / 8 Nut & Bolts - 1 Sete ) Push & Clip Handle To Close / Open - 1 No. 53 Repairing Of Following Capacity Of Submersible / Monobloc Pumpset I / C Replacement Of Mechanical Seal Tc / Tc Upper, Mechanical Seal Tc / Tc Lower, Ball Bearing, O Ring, Stamping Repairing, Including Dismantling, Assembling, Commissioning And Testing The Same On Load After Making Electric Connections At Site I / C Site Visit By Engineer And To And Fro From Site To Workshop & Back To Site Etc.Complete With Credit Of Dismantle Etc As Required.A ) 3 Hp 54 B ) 15 Hp 55 Rewinding Of Following Capacity 3 Phase Multi-Stage Submersible / Mono-Submersible Pump-Set With Suitable Size Water Proof Copper Conductor Wire I / C Brazing Metalling Turning & Polishing Of Shaft, Replacement Of Gm Bearing Bush, Thrust Bush, Thrust Plate, Necessary Sleeves, Pads Etc. I / C Buy Back Of Dismantled Material And Making Connection, Testing And Commissioning Etc. Complete As Reqd.A ) 3 Hp 56 B ) 15 Hp 57 Liftingof Existing Submersible Bore Well / Open Well 3 Hp To 10 Hp Capacity Pump Set From The Bore Well With Chain Pulley Block & Tripod Stand I / C Cartage Charge At Site From The Work Shop. 58 Lowering Of 3 Hp To 10 Hp Capacity Bore Well / Open Well Pumpset In The Bore Well With Chain Pulley Block And Tripod Stand I / C Cartage Charge Pump Set From Work Shop To Site Credit Of Old Dismantle Etc, As Reqd. 59 Sitc Of 5 Hp / 3.75 Kw Submersible Pump Starter Having Relay Range 6-10A Suitable For 415V 50Hz, 3 Phase Motor Complete With Sheet Enclosure, Ammeter, Voltmeter, Start Stop Push Button, On Off Led Indication Lamp And All Other Accessories Including Connections & Testing Credit Of Dismantle Etc Complete As Required. 60 Supplying & Fixing / Laying Of 3 Core 2.5 Sq.Mm Flat Water Proof Copper Conductor Submersible Cable I / C Connection For Submersible Pumpset Etc. Complete As Reqd.

Key Value

Document Fees
Refer document
EMD
INR 47871.0 /-
Tender Value
INR 23.93 Lakhs /-

BOQ Items

Name of Work:MOEI & Fans including Pumpset, Compound lighting etc at DTE Staff Qtrs at Sawan Park , Delhi. (SH: MOEI & RMO Pump Sets)
Sl. No. Item Description
1Round the clock operation & maintenance i/c attending and rectifying complaints of all electrical installations i/c compound light & drinking water supply pump etc. installed in the campus in all working days including sundays and holidays by providing following staff etc. as required (a) Wiremen cum Pump cum E&M operator- 1 Nos in each shift (b) Khallasi-1 Nos -In general shift and as and when required
2Supplying & fixing of following electrical accessories suitable for existing different type fitting/switch box i/c testing etc. as required. (Labour already included in Item No. 1) a) S.P. 5/6 A, one way modular switch, ISI marked
3b) S.P. 15/16 A, one way modular switch, ISI marked
4c) 3 pin 5/6 A modular socket outlet, ISI marked
5d) 6 pin 15/16 A modular socket outlet, ISI marked
6e) Stepped type Modular Fan regulator (2 module)
7f) S.P. 5/6 A, one way switch, piano type ISI marked
8g) S.P. 15/16 A, one way switch, piano type ISI marked
9h) 3 pin 5/6 A socket outlet, piano type ISI marked
10i) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
11j) Bell push, piano type
12k) PVC Batten/ Angle Holder
13l) 1 or 2 Module Cover plate
14m) 3 Module Cover plate
15n) 8 Module Cover plate
16o) 12 Module Cover plate
17p) Step Type Fan Regulator (Socket Type Piano )
18Supplying & Fixing of 3mm thick phenolic laminated sheet on existing switch board, loose wire box making holes etc as reqd.
19Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-B
20Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group-A
21b) Group-B
22Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required a) 3 x 1.5 sq. mm
23b) 3 x 4 sq. mm
24c) 3 x 6 sq. mm
25Supplying and fixing of following sizes ofsteel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required a) 20 mm
26b) 25 mm
27Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
28Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
29Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
30Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
31Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, testing etc. as required.
32Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. a) 180 mm X 100 mm X 60 mm deep
33b) 200 mm X 250 mm X 75 mm deep
34Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way, Double door
35Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. a) For 12 way, Double door SPN MCBDB
36Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
37b) Single pole and neutral
38Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 100 A, 16 kA,TPMCCB
39Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
40Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
41Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
42Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
43Supplying, Installation, testing and commissioning of pre-wired, Indoor LED batten with extruded aluminium housing & opal diffuser. IP20 of following types suitable for cool day-light having CCT (5700K to 6500K), power factor >0.90, CRI > 75 (including dismantling the old fitting if any wherever required ) & minimum Lumens output should be > 90 lumens per watt. with all accessories etc. directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. b) 1x20 wattsLED batten fitting.
44Supplying & Fixing of decorative, wall mounting, brushed nickel/ SS finish fixture with Opal Glass diffuser suitable for 9 W LED lamp B22 base i/c 9 W LED Lamp complete with connection testing commissioning etc as reqd.
45Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE star rated, ceiling fan, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc complete as required.
46Supplying and Installation of heavy duty exhaust fan of 300 mm sweep 900 rpm in the existing opening, i/c making the hole suitable the size of the above fan making good the damage, connection testing commisioning with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.
47Supplying & fixing aluminium louvers/ shutters complete with frame suitable for 300 mm sweep exhaust fan etc as reqd.
48Rewinding of 1200/1400 mm ceiling fan with suitable size super enamelled copper wire after dismantling from the existing position and refixing the same on the existing position/ceiling with suitable size nut, bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of fan and cleaning the fan and fan blade with detergent and making connection with 1.5 sq. mm FRLS PVC insulated, copper conductor wire, testing and commissioning etc. complete as required and buy back the dismantled material.
49Dismentling, overhauling & reinstallation of existing ceiling fan complete with cleaning, greasing, replacement of bush, suitable ball bearing, split pin, nuts and bolts, etc with test run i/c credit of dismentle materials etc as reqd.
50Replacement of defective ball bearing in the existing Ceiling fans i/c greasing complete etc. as reqd. a) 6201
51b) 6202
52SITC of pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required. a) 32 Amp 5 Way connector with backelite base. b) 6 Amp SP MCB "C" Curve (10 KA) - 1 No. c) Earth Studs - 2 Sets. d) 40 x 5 mm clamp with 2 Nos. 3/8" Nut & Bolts - 1 Set e) Push & Clip handle to close/open - 1 No.
53Repairing of following capacity of Submersible/monobloc Pumpset i/c replacement of mechanical seal TC/TC upper, mechanical seal TC/TC lower, ball bearing, "O" Ring, stamping repairing, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to and fro from site to workshop & back to site etc.complete with credit of dismantle etc as required. a) 3 HP
54b) 15 HP
55Rewinding of following capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd. a) 3 HP
56b) 15 HP
57Liftingof existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with chain pulley block & tripod stand i/c cartage charge at site from the work shop.
58Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with chain pulley block and tripod stand i/c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd.
59SITC of 5 HP /3.75 kw Submersible Pump Starter having relay range 6-10A suitable for 415V 50Hz, 3 phase motor complete with sheet enclosure, ammeter, voltmeter, start stop push button, on off LED indication lamp and all other accessories including connections & testing credit of dismantle etc complete as required.
60Supplying & fixing/ laying of 3 core 2.5 sq.mm flat water proof copper conductor submersible cable i/c connection for submersible pumpset etc. complete as reqd.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy