Tender For Repairs / Maintenance Of Ht / Lt Electric Panel With Misc Allied Works At Cgra Naliya And Icgs Jakhau Under Age (I) (Cg) Jakhau
Tender Overview
Project Description
Repairs / Maintenance Of Ht / Lt Electric Panel With Misc Allied Works At Cgra Naliya And Icgs Jakhau Under Age ( I ) ( Cg ) Jakhau
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Mar-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-Mar-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm, 3.5 core, completeall as specified and as directed by Engr-in-charge. |
| 2 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, completeall as specified and as directed by Engr-in-charge. |
| 3 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core, completeall as specified and as directed by Engr-in-charge. |
| 4 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core, completeall as specified and as directed by Engr-in-charge. |
| 5 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 2 core, completeall as specified and as directed by Engr-in-charge. |
| 6 | Supply, laying and testing, in replacement XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm, 2 core, completeall as specified and as directed by Engr-in-charge. |
| 7 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in soft / loose soil all as specified and directed |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil |
| 9 | Removing excavated material (soils) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point |
| 10 | Supply & laying factory made unreinforcedprecast concrete cable cover conforming toIS- 5820- 1970,Class LV , Type I, flatsize 250 mm X 150 mm X40 mm in trenches as protection toLT UG cable all as specified and directed by Engr-in-Charge. |
| 11 | M&L for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layers all as specified and directed by Engr-in-Charge. Note:-For measurement purpose punned thickness of sand will be considered. |
| 12 | Supplying and laying in replacement synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. |
| 13 | M&L for checking of transformer for any leakage and rectify the same by tightening of nut, bolt or replacing broken rubber gasket, drain plug etc. complete all as directed and directed by Engr-in-Charge. |
| 14 | Dehydration of transformer oil of transformers of different capaciteslocated at CGRA Naliya and ICGS Jakhau by dehydration machine and obtained dielectic strength should be more than 40 KV at 2.5mm gap complete all as specified & directed by Engineer-in-Charge. |
| 15 | M&L for topping up of transformer oil having dielectric strength not less than 45 KV(at 2.5 mm gap) high voltage as per IS specification of low viscosity complete all as directed by Engineer-in-ChargeMake:- Powerlink / Power-oil / Savita |
| 16 | M&L in replacement of silica gel of transformer breather complete all as directed by Engineer-in-Charge |
| 17 | Taking out old unserviceable lightening arrestors , supply and fix lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV, 3-Phase, earthed distribution systemcomplete all as specified & directed by Engineer-in-Charge. |
| 18 | Repairing existing outdoor LT panel by removing the unserviceable hinges from doors (1.6mm thick MS), grinding the welded portion, denting and levelling the door, welding suitable new hinges (Approx. 0.50 Kg) to doors including locking arrangement and applying one coat of synthetic enamel paint as that of existing colour complete all as specified and as directed. |
| 19 | Material and labour in repair for earthing completewith galvanizedearth plateelectrode in 60 cm x 60 cmx6 mm thick buried directly in ground verticallyat a depth not less than 2.25 meterbelowgroundlevel with top edgeof earth plateat depth not lessthan 1.5 mtrbelow ground level connecting to and including GI strip32 mm x 6 mmby means of GI bolts, nuts, check nuts and washerlight grade40 mm dia GI protectionpipeandconnected to equipment, GIpipe medium grade20 mmdia forwatering includingfunnel wire mesh, RCCpitcoverand PCC 1;2:4type B-1 including Rocksalt, charcoal, excavationand earth work,disposalof surplussoil shown as plateNo 3 of SSR Part - I2009 and all as specified complete.Note : - Theunitrate quoted shalldeemed to have included for GIprotection pipe, GIearth stripup to 7.5mtr, GI waterpipe, wiremesh , funnel , excavation and earthwork, RCC pitcover complete. |
| 20 | M&L for lowering of High Mast lantern to carry out repairs for lights and cables, fittings,gear box servicing ,greasing of motor etc. and raising the lantern to its original position after replacement of items such as LED Flood light,LED driver etc.Note:-LED flood light, LED driver etc will be measured and paid seperately as supply only |
| 21 | Supply only LED driver suitable for flood light 180 watt to 250 watt , out door type of existing make and model as approved by accepting officer. |
| 22 | S&F in repairs power AC power contactor of rating 32 Amps AC3, 3 Pole complete all as specified and as directed. Make: L&T/ Siemens/ Schneider |
| 23 | M&L for Cutting of worn out aluminium cable terminal lugs from the HT/LT cable of any size, crimping of new aluminium cable Lugs and fixing with transformer / LT panel terminal studs including cutting/dressing of cable, excavation, redressing of excavated surface, providing sand cushioning and brick protection as directed. |
| 24 | M&L for cable jointing kit for 1.1 KV grade cable, straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm complete all as specified and directed by Engineer-in-charge. |
| 25 | M&L for cable jointing kit for 1.1 KV grade cable, straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and directed by Engineer-in-charge. |
| 26 | M&L for cable jointing kit for 1.1 KV grade cable, straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm complete all as specified and directed by Engineer-in-charge. |
| 27 | S&F in repair MCCB, 160 Amps, four pole, 25 KA, 415 volt adjustable type complete all as specified and directed by Engineer-in-charge. |
| 28 | S&F in repair MCCB, 100 Amps, four pole, 16 KA, 415 volt adjustable type complete all as specified and directed by Engineer-in-charge. |
| 29 | S&F in repair MCCB, 63 Amps, four pole, 16 KA, 415 volt adjustable type complete all as specified and directed by Engineer-in-charge. |
| 30 | S&F in repair MCCB, 40 Amps, four pole, 16 KA, 415 volt adjustable type complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply and fixing in replacement street light fitting in new generation energy saving environmental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 3500-7000 , system effiency 100 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 , operating voltage 140-270 Volt AC and impact of capacity 70 Watt complete all as specified and directed by Engineer-in-charge. Make:- Philips /Havells / Wipro/ Bajaj / Halonix |
| 32 | M&L for taking down street light fitting from steel/PCC pole, supply & fixing of new LED driver of exisiting make and model of rating 50 to 60 Watt by taking out unserviceable LED driver and refixing the street light at its original position complete all as specified and as directed. Make: Bajaj/Crompton Greaves /C&S. Note: Work shall be done after switching off power supply from main LT panel. |
| 33 | Supply & Fixin replacement LED CONE BOLLARD light IP 65, 8 watt , maximum illumination aspect in surrounding, PCC foundation 20x20x30 cm including demolition of old PCC foundation complete all asspecified and directed. Make - Havells, Model:CONEBL8WLED830PSYMTOPCM or equivalent in Bajaj/Halonix |
| 34 | Supply & Fixin replacment LED new generation, IP 65 LED post-top lantern 15 watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover for soothing uniform illumination complete all asspecified and directed.Make - Havells, Model:CORALMINIPT15WLED757PSYMTOPC or equivalent in Bajaj/Halonix |
| 35 | M&L for GI post for garden light made of GI pipe light grade 50 mm dia 1.5 mtr long 30cm in foundation and 1.2 mtr above ground duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, PCC foundation 30x20x20cm incl dismantling old foundation and taking out old rusted GI post complete all asspecified and directed. |
| 36 | S&F astronomical digital timer switch 16 amp, LCD display, astronimical programable by entering longitude and latitude, also adjustable up to plus/minus 2hrs turning on later and off earlier than sunset and sunrise, with battery backup,suitable for connection with three phase supply incl taking down old unserviceable timer switch of any type complete all as specified and as directed. Make: L&T/ Siemens/ Schinder/ Havells |
| 37 | S&F in replacement FRP based outdoor type Junction box pole Hinged (L) mounted with clamps and including MCB SP, 6 Amps complete all as specified and as directed. Make: Sintex Model No: GS JB 2817 or equivalent as approved by accepting officer. |
| 38 | M&L for preparation of old surfaces of steel swan neck tubular polesand making strip white and blue colour up to 1.5 mtr height from top of PCC foundation block with synthetic enamel paint and painting the complete pole with one coat of aluminium paint above 1.5 mtr heightincluding numbering of poles with synthetic enamel paint black colourin 80 mm high letters complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&Lfor preparation of old surface of PCC poles and applying two coats of synthetic enamel paint over a coat of red oxide primer with black & white or yellow colour strips 30cm each up to1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high lettersabove 150 mm the top strip complete all as specified and directed by Engr in charge. |
| 40 | M&L for painting of GI pipe bracket and clamp any size on pole security lights applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and as directed. |
| 41 | Supply & Fixin replacment Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25x20cm size complete all as specified and as directed. |
| 42 | Trimming of tree branches wherever touching to street light around one meter clear of street light and removing of trimmed branches and disposing the debris off MD land complete all as specified & directed.Note:-(i) Any damage caused to the street light due to above will be repaired by contractor at his own expences.(ii) Required T&P like axes, ladder etc shall be provided by the contracor. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender