Tender For Repair / Maintenance Of Cooling Appliances, Ac Plants And Its Connected Items And Repair/Maintenance Of Pump, Motors, Starters And Connected Items At Air Force Station Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Cooling Appliances, Ac Plants And Its Connected Items And Repair/Maintenance Of Pump, Motors, Starters And Connected Items At Air Force Station Pathankot. Submission Date for this Tender is 17-03-2023. Starter Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36462695
Corrigendum : Tender For Repair / Maintenance Of Cooling Appliances, Ac Plants And Its Connected Items And Repair/Maintenance Of Pump, Motors, Starters And Connected Items At Air Force Station Pathankot
Open Tender
Indian
Punjab
pathankot
17-03-2023

Tender Details

Repair / Maintenance Of Cooling Appliances, Ac Plants And Its Connected Items And Repair / Maintenance Of Pump, Motors, Starters And Connected Items At Air Force Station Pathankiot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

Name of Work : REPAIR / MAINT OF COOLING APPLIANCES, AC PLANTS & ITS CONNECTED ITEMS AND REPAIR/MAINT OF PUMP, MOTORS, STARTERS & CONNECTED ITEMS AT AIR FORCE STATION PATHANKOT
Sl. No. Item Description
1Comprehensive/preventive maintenance of the following Window / Split ACs / Water cooler / Refrigerator /Deep Freezer of different capacitiesby carrying out periodically maintenance of equipments including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/cooling coils complete and attending complaints all as specified and as directed by Engr-In-Charge for following: (a) 1.5/2.0 Ton capacity Split AC complete all as specified and directed by theEngineer-in-Charge.
2All as per item No 1.00 above but (b)1.5/2.0 Ton capacity window type AC complete and attending complaints all as specified and as directed by Engr-In-Charge.
3All as per item No 1.00 above but(c) Water cooler ofany capacity complaints all as specified and as directed by Engr-In-Charge.
4All as per item No 1.00 above but(d) Refrigerator of any capacity complaints all as specified and as directed by Engr-In-Charge.
5All as per item No 1.00 here-in-before above but(e) Deep freezer of any capacity complaints all as specified and as directed by Engr-In-Charge. Note for items No 1.00 to 1.04 :- (i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis, (ii) Window/ Split Acs are to be maintained for heating as well as cooling mode where installed all as specified and directed. (iii) The contractor shall ensure and assesed at the site any initial maintenance required, to make the all Window/Split ACs/Water cooler / Refrigerator /Deep Freezer/Desert cooler in fully proper working condition. (iv) The date of periodical check will start from the date of commencement of work. (v) After completion of contract, contractor shall hand over the all " handed over Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler" in perfect running/functioning condition to the department. (vi)Contractor shall provide his authorised Cell/mobile No.and local address to contact and communicate the message for any break down and contractor"s rep will visit the office twice a day (0930 Hrs and 1700 Hrs) to collect the day to daycomplaints of any nature/type. (vii) Penalty for not rectifying the defect in time(within 24 hrs)will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user"s "Satisfactory slip "will be produced by contractor to concerned JE E/M. (ix) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made. (x) Old material obtained from spares replacedunder this item shall be contractor"s property and will be measured as per credit schedule. (xi) Cost of minor spares i.e, insulation to copper tubes, soldering, internal wiring to cooling appliances are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately, Refrigerant gas will only be measured when major items i.e, Comperessor, Condensing coil, Cooling coils are replaced, else cost of refrigerant gas required for less cooling, due to leakage etc will be deemed to be included in quoted rates. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates.
6Supply only following items 2.00 to 2.29to be fixed under Item No. 1.00 to 1.04 here-in-before above:- (a) Running capacitor of capacity 1.5 to 2.5 MFD as per existing sample and requirement complete all as specified and directed by theEngineer-in-Charge.
7(b) Running capacitor of capacity 4 to 8 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
8(c) Running capacitor of capacity 10 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
9(d) Running capacitor of capacity 30 to 42 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
10(e) Running capacitor of capacity 45 to 60 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
11(f) Starting capacitor, 40/60 MFD to 80/100 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
12(g) Starting capacitor, 100/120 MFD to 120/150 MFD as per existing sample and requirement complaints all as specified and as directed by Engr-In-Charge.
13(h) Thermostat switch for cooling appliances as per existing sample complaints all as specified and as directed by Engr-In-Charge.
14(j) Overload relay for cooling appliances as per existing sample complaints all as specified and as directed by Engr-In-Charge.
15(k) Starting relay for cooling appliances as per existing sample complaints all as specified and as directed by Engr-In-Charge.
16(l) Capillary tube special annealed double wound copper tubing as per existing sample complaints all as specified and as directed by Engr-In-Charge.
17(m) Copper tubing for cooling appliances of required size as per existing sample complaints all as specified and as directed by Engr-In-Charge.
18(n) Condensor Fan blade for cooling appliances of any size as per existing sample complaints all as specified and as directed by Engr-In-Charge.
19(o) Blower Fan blade for cooling appliances of any size as per existing sample complaints all as specified and as directed by Engr-In-Charge.
20(p) Blower Motor for cooling applinaces of any size as per existing sample complaints all as specified and as directed by Engr-In-Charge.
21(q) Condensor Motor for cooling appliances of any size as per existing sample complaints all as specified and as directed by Engr-In-Charge.
22(r) PCB card for refrigerator as per existing sample complaints all as specified and as directed by Engr-In-Charge.
23(s) PCB card for Air conditioner including remote as per existing sample complaints all as specified and as directed by Engr-In-Charge.
24(t) Push cock stainless steel as per existing sample for water cooler complaints all as specified and as directed by Engr-In-Charge.
25(u) Float valve as per existing sample complaints all as specified and as directed by Engr-In-Charge.
26(v) Plastic drain pipe for water cooler as per existing sample complaints all as specified and as directed by Engr-In-Charge.
27(w) Plastic drain pipe for Air conditioner as per existing sample complaints all as specified and as directed by Engr-In-Charge.
28(x) Swing motor for Air conditioner as perexisting samplecomplaints all as specified and as directed by Engr-In-Charge.
29(y) PVC connection as per existing sample complaints all as specified and as directed by Engr-In-Charge.
30(z) Display unit of Split/Window AC complaints all as specified and as directed by Engr-In-Charge.
31(aa) Strainer/Filter for cooling appliances as per existing samplecomplaints all as specified and as directed by Engr-In-Charge.
32(ab) Gasket, suitable for magnetic door of Refrigerator of any make and capacity and as per samplecomplaints all as specified and as directed by Engr-In-Charge.
33(ac) Chilling tray, suitable for Refrigerator of any make and capacity as per existing samplecomplaints all as specified and as directed by Engr-In-Charge.
34(ad) Vegetable tray, suitable for Refrigerator of any make and capacity as per existing samplecomplaints all as specified and as directed by Engr-In-Charge.
35(ae) Freezer chamber for refrigerator of any make and capacity as per existing samplecomplaints all as specified and as directed by Engr-In-Charge.
36M&L for replacement of condensing coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
37All as per item No 3.00 here in before above but for Water cooler/ refrigerator/ deep freezer of any capacity complete all as specified and directed by Engr-in-Charge.
38M&L for replacement of cooling coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
39All as per item no 4.00 here in beforeabove but for refrigerator/water cooler/Deep freezer of any capacity as per sample complete all as specified and directed by Engr-In-Charge.
40Taking out of desert cooler from the site, de-assembling, cleaning of distribution pipe for proper water spray on pads, oiling and greasing the fan motor and tullu pump, checking of electrical circuit, fixing broken parts with the help of nutbolts, welding if required etc complete all as specified and directed by Engr-In-Charge.
41M&L for shifting of window/Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to Copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge.
42Supply and fixing in Replacement of electrical lead from main connection3 core PVC insulated copper conductor of size 2.5 Sqmm in PVC conduit concealed/recessed as required at site complete all as specified and directed by Engr-In-Charge.
43All as per item No 9.00 above but of size 4 sqmm complete all as specified and directed by Engr-In-Charge.
44Supply and filling of Gas R-22 for charging to window/Split Air conditioner/Deep freezer and water cooler to maintain adequate gas pressure complete all asspecified and directed by Engr-in-Charge.
45All as per itemNo 11.00 above but for gas R-407/410 complete all as specified and directed by Engr-In-Charge.
46All as per item No 11.00 above but for gas R-134A complete all as specified and directed by Engr-In-Charge.
47M&L for replacement of blower motor for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
48M&L for replacement of blower fan blade suitable for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
49M&L for replacement of submersible tullu pump suitable for desert cooler complete all as specified and directed by Engr-In-Charge.
50S&F in replacement indoor type unit of split type air conditioner 1.5 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
51S&F in replacement outdoor unit of split type air conditioner 1.5 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
52S&F in replacement indoor type unit of split type air conditioner 2.0 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
53S&F in replacement outdoor unit of split type air conditioner 2.0 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
54M & L for replacement of rusted desert cooler body of desert cooler capacity upto 4000 cum/hr with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size matching with existingfabricated out of 20 gauge mild steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water, electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min 3 mtr in length). External surface shall be spray painted over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as per sampleand specified and directed by the Engr- in- Charge.
55M&L for replacement of rusted louver suitable for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
56M&L for replacement of front grill including control panel prewired for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
57Supply and fixing in replacement of wood wool pads different sizes as required with fixing accessories of superior quality /high density for desert cooler complete and all as specified and directed by Engr-In-Charge
58Supply and fixing in replacement front show grill of window AC 1.5 Ton capacity of any make as per sample complete all as specified and directed by Engr-In-Charge.
59Supply and fixing in replacement Metal clad Plug 2 pin and earth 20 Amps single phase complete all as specified and directed by Engr-In-Charge.
60All as per item No 27.00 abovebut of capacity 32 Amps complete all as specified and directed by Engr-In-Charge.
61Supply and fixing in replacement Metal clad Socket for 2 pin and earth 20 Amps single phase complete all as specified and directed by Engr-In-Charge.
62All as per item No 28.00 above but of capacity 32 Amps complete all as specified and directed by Engr-In-Charge.
63Material and labour for providing locking arrangement in water cooler tank for provisioning of padlock including hinges, fixing clamp, welding/nut bolts/rivetting as required complete all as specified and directed by Engr-In-Charge.
64S&F in replacement water collector rack in water cooler for safe flow of unused water as per existing sample complete all as specified and directed by Engr-In-Charge.
65M&L for repair to broken gates of deep freezer/water cooler/Refrigerators by providing proper hinges at ends and to ensure complete compactness of the equipment to arrest cooling inside complete all as specified and directed by Engr-In-Charge.
66M&L for removing the old unserviceable hermatically sealed compressor unitfrom Water cooler of 40/80 &160/120 ltrs capacity and fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
67All as per item No 33.00 above but for 1.5 TR split/window type AC complete all as specified and directed by Engr-In-Charge
68All as per item No 33.00 abovebut for 2.0 TR split type AC complete all as specified and directed by Engr-In-Charge
69All as per item No 33.00 abovebut for upto 185 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
70All as per item No 33.00 abovebut for refrigerator above 185 ltrs but upto 320 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
71All as per item No 33.00abovebut for Deep freezer of capacity above 185 ltrs upto 320 Ltrs complete all as specified and directed by Engr-In-Charge.
72Supply and fixing in replacement Plug Top 5 Amps, 230 volts AC complete all as specified and directed by Engr-In-Charge. Make: Havells/Anchor/Cona/SSK
73All as per item No 39.00 above but for 15 Amps complete all as specified and directed by Engr-In-Charge.
74Supply & fixing in replacement of potential correction unit, with digital display and designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V within tolerance limit and suitable for AC of capacity 2.0 Ton not less than 5 KVA complete all as specified and directed by Engr-In-Charge.
75Supply & fixing Gate valve of size 15mm dia with ISI marked complete all as specified and directed by Engr-In-Charge.
76Repair to voltage stablizer by rewinding of transformer with suitable copper wire enamelled as existing gauge for stablizer 1.0 to 5 KVA including replacement of Voltmeter, selector switch, termination box etc as required complete all as specified and directed by Engr-In-Charge.
77M&L for servicing of central AC plant unit of any type and capacity upto 39 ton at site including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and and replacement of defective filter, relay, capacitor over load protector etc as required, rewiring if necessary complete all as specified and directed by Engr-in-Charge. Note: (a) Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost. (b) Items to be replaced needs to be checked only for serviceability and will be measured and paid seperately under respective item of schedule complete all as specified and directed by Engr-In-Charge.
78M&L for taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including reassembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed.
79Supply and fixing Filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr-In-Charge.
80Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts or as required complete all as specified and directed complete all as specified and directed by Engr-In-Charge.
81M&L for replacement of PVC honey comb fins suitable for cooling Tower of capacity upto 3x39 TR complete as per sample all as specified and directed by Engr-in-Charge
82M&L for replacement of water distribution flaps of cooling tower of AC Plant capacity upto 3x39 TR as per sample complete all as specified and directed by Engr-In-Charge.
83M&L in replacement of air filter of AHU as per sample made of suiable filter with efficiency not less then 90% class 1 to 10 micron, matching with existing sample complete all as specified and directed by Engr-in-Charge.
84M&L for cleaning of Cooling tower of any capacity by draining out water from inside, and including descaling of base tank and sprinkler including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
85M&L for cleaning of base tank of Air cooling plant having blower motor of 15 HP capacity by draining out water from inside and including descaling of tank and water sprinklers including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
86Supply and changing/top up of compressor oil N-68 to AC Plant compressor upto adequate level complete all as specified and directed by Engr-in-Charge.
87Repair/servicing of air handling unit, cleaning of all duct from A.H.U.to supply air grill and cleaning/descaling of cooling coil, water pressure meter, greasing to bearings and taking out the dust and mud complete all as specified and directed by Engr-In-Charge
88Preparation of old surfaces for painting of existing Desert cooler/Water cooler/MS Pipes and applying two coats of synthetic enamelled paint of color matching with existing over one coat of primer red oxide complete all as specifed and directed by Engr-in-Charge.
89Supply and fixing in replacement water spray nozzles 32mm dia of Air cooling plant as per sample complete all as specified and directed by Engr-In-Charge
90Supply and fixing in replacement air grills/diffusers fabricated out of powder coated extruded aluminum sections including bird screen/VCD etc as per sample complete all as specified and directed by Engr-In-Charge.
91Supply and fixing in replacement of by pass safety valve for AC plant of capacity upto 39 TR as per sample complete all as specified and directed by Engr-In-Charge.
92Supply and fixing in replacement electrostatic scale preventor as per sample suitable for upto 39 TR AC plant complete all as specified and directed by Engr-In-Charge.
93Supply and fixing in replacement water pressure gauge assembly complete with connection pipe to the existing pipe line complete withmatching with existing sample complete all as specified and directed by Engr-In-Charge.
94Supply and fixing in replacement temperature gauge assembly able to display temperature in degree and farheniet complete including connection to the existing pipe line matching with existing sample complete all as specified and directed by Engr-In-Charge.
95Supply and fixing in replacement HP/LP cutout complete all as specified and directed by Engr-In-Charge.
96Supply and fixing of thermostatic expansion valvesuitable for central AC plant of capacity 5.5 to 39 TR, complete and all as specified and directed by Engr-in-Charge.
97M& L for Replacement pilot control solenoid coil suitable for AC plant matching with existing sample complete all as specified and directed by Engr-in-Charge.
98Supply and fixing in replacement oil failure switch matching with existing sample complete and all as specified and directed by Engr-in-Charge.
99Supply and fix in replacement MCCB 63 Amps, 3/4 Pole, complete all as specified and directed by Engr-In-Charge.
100All as per item No 66.00 above but of capacity 100 Amps complete all as specified and directed by Engr-In-Charge.
101Supply and fixing in replacement MCB TPN, 63 Amps 415 volts complete all as specifeid and directed by Engr-In-Charge.
102Supply and fixing in replacement of Power contactor 80 Amps rating three pole, 415 volts complete all as specfied and directed by Engr-In-Charge.
103All as per item No 69.00 above but for 18 Amps complete all as specfied and directed by Engr-In-Charge.
104All as per item No 69.00 above but for 40 Amps complete all as specfied and directed by Engr-In-Charge.
105Supply and fixing in replacement V belt of any size matching with existing sample complete all as specified and directed by Engr-In-Charge
106Supply and fixing in replacement Controller circuit board for AC chiller of capacity 39 TR as per sample complete all as specified and directed by Engr-In-Charge
107Supply and fixing in replacement Controller circuit board for Package type AC plant of capacity upto 16.5 TR as per existing sample complete all as specified and directed by Engr-In-Charge.
108Supply and fixing in replacement of LCD display cum operating unit for package type AC plant of capacity upto 16.5 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
109Supply and fixing in replacement of LCD display cum operating unit for AC plant of capacity upto 39 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
110Supply and fixing in replacement hermatically sealed reciprocating type compressor unit of ac plant with capacity upto 39 TR of make and model as per sample complete all as specified and directed by Engr-In-Charge.
111Supply and fixing in replacement thermal overload relay suitable for upto 7.5 HP three phase induction motor as per existing sample complete all as specified and directed by Engr-In-Charge.
112Supply and fixing in replacement ball bearing for blower motor for upto 40 HP motor capacityas per existing sample complete all as specified and directed by Engr-In-Charge.
113Supply and fixing in replacement heating element for hot water generator any capacity as per existing sample complete all as specified and directed by Engr-In-Charge.
114Replacement of unserviceable wiringfrom LT panel to motor of size 10 sqmm 3 core FRPVC insulated flexible copper conductor in PVC conduit and flexible conduit at termination end complete with fixing arrangements such as clamps and screws etc asspecified and directed by engr in-charge.
115Replacement of unserviceable wiringfrom LT panel to motor of size 6 sqmm FRPVC insulated flexible copper conductor in PVC conduit and flexible conduit at termination end complete with fixing arrangements such as clamps and screws etc asspecified and directed by engr in-charge.
116M&L for replacement of MS pipes 80 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
117M&L for replacement of GI pipes 15 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
118Supply and fixingGate valve of size 25mm dia with ISI marked complete all as specified and directed by Engr-In-Charge
119Supply and fixing Gate valve of size 15mm dia with ISI marked complete all as specified and directed by Engr-In-Charge
120Supply and fixing in replacement gate valve suitable for 80mm dia MS Pipe complete all as specified and directed by Engr-In-Charge.
121Supply and fixing in replacement ofsingle phase preventer complete in all aspects matching with existing sample complete all as specified and directed by Engr-in-Charge.
122Supply and fixing Star delta Starter fully automatic suitable for 415V AC motor having capacity 40 HP with over load relay, contactors, timers, single phase preventer of suitable capacity prewired incl taking down the existing unserviceable starter incuding oil complete all as specified by Engr-in-charge.
123Supply and fixing Star delta Starter fully automatic suitable for 415V AC motor having capacity 25 HP with over load relay, contactors, timers, single phase preventer of suitable capacity prewired incl taking down the existing unserviceable starter incuding oil complete all as specified by Engr-in-charge.
124Supply and fixing FASD starter panel suitable for three phase 40 HP submersible pump with over load relay having range of 36 to 60 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge.
125Supply and fixing FASD starter panel suitable for three phase 30 HP submersible pump with over load relay having range of 30 to 50 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge.
126Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 15 to 25 HP matching with existing sample including connections with existing star delta starters complete all as specified and directed by Engr-In-Charge
127Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 30 to 40 HP matching with existing sample including connection with existing star delta starter complete all as specified and directed by Engr-In-Charge
128Supply and fixing in replacement single phase prevention relay suitable for star delta starters, of capacity upto 40 HP, with auto, mannual and bypass operation, with time delay setting including wiring and connection with existing star delta starter complete all as specified and directed by Engr-In-Charge.
129Supply and fixing in replacement electronic timer suitable for star delta starters, having coil voltage 380 to 415 volts, with time delay 3 to 30 seconds, complete including wiring and connections with existing star delta starter complete all as specified and directed by Engr-In-Charge
130M&L for Strip opening of pump of any type of submersible/centrifugal motor 20 HP to 40 HP of any stage/ size/ make and re assembling including replacement of defective items and reassembling complete after repair including testing at workshop complete all as specified and directed by Engr-In-Charge. (Note:- major defective items replaced will be measured and paid seperately under respective item of schedule, cost of items not mentioned in schedule and to be replaced is deemed to be included in quoted rates.)
131Supply only following items No 98.00 to 98.07 to be fixed under items No 97.00above complete all as specified and directed by Engr-In-Charge. (a)Pump shaft stainless steel for 20to 40 HP pump matching with existing size
132(b)Impeller bronze/ Gun metal for 20 to 40 HP pump matching with existing size
133(c)CI neck ring for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
134(d)Gun metal intermediate bush for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
135(e)Suction/Discharge Bush for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
136(f)CI bowl for pump for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
137(g)Middle distance bush of stain less steel for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
138(h) Shaft coupling stain less steel for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
139Taking out submersible pump set 20 HP to 40 HP from the bore well in any depth complete with column pipe and other connected part and lowering the same after repair of the pump set including checking of pump set for faults before shifting to workshop complete all as specified and directed by Engr-In-Charge. (Note: Required T&P for above work and transportation to workshop and taking back is deemed to be included in quoted rates)
140M&L for Strip opening 3 phase 20 to 40 HP capacity AC submersible motor taking out burnt winding coils complete and rewinding with insulated water proof winding wire matching with existing size including seal PVC (water proof compound) reassembling the motor and testing at workshop complete all as specified and directed by Engr-In-Charge. (Note: Insulation to wires, windings, varnishing,and other items required for rewinding and making motor water proof not mentioned in description and T&P required for this job is deemed to be included in quoted rates.)
141Supply and fixing inreplacement thrust plate matching with existing size suitable for 20 to 40 HP electric Motor complete all as specified and directed by Engineer-in-Charge.
142Supply and fixing in replacement Stud with nuts including spring washer matching with existing complete all as specified and directed by Engr-In-Charge.
143Supply and fixing in replacement Water seal suitable for submersible motor matching with existing complete all as specified and directed by Engr-In-Charge.
144Supply and lower submersible copper cable 16 Sqmm, 1100 volts,3 Coreall as complete all as specified and directed by Engr-In-Charge.
145Supply and lower submersible copper cable 25 Sqmm, 1100 volts,3 Coreall as complete all as specified and directed by Engr-In-Charge.
146Supply and replacement of union nut PVC for chlorine dosing system matching with existing sample complete all as specified and directed by Engineer in Charge complete
147Supply and replacement ofreducer for dosing pump all asper existing sample complete all as specified and directed by Engineer –in-Charge.
148Supply and fixing in replacement of PumpTube of Decrin Dosing Pump matching with existing sample complete all as directed and specified by Engr-in- Charge .
149Supply and fixing in replacement of Motor Agitator including shaft blades etc for chlorine dosing system matching with existing sample complete all as directed and specified by Engineer-in-Charge
150Supply and fixing in replacement high density polyethylene pipe (HDPE) having pressure rating 6kgf/cm2 fixed complete to walls, ceilings or in floors from dosing pump to chlorine feeding point matching with existing sample complete all as specified and directed by Engineer-in-Charge
151Supply and fixing single core copper cable 25 sqmm complete with all connection all as specified and directed by Engr In Charge.
152Supply and fixing in replacement non return valve suitable for dosing system matching with existing sample complete all as specified and directed by Engr-In-Charge.
153Supply and fixing in replacement of 150 mm bore Non return valve double Flanged cost iron type and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS complete all as specified and directed by Engr-In-Charge.
154Supply and fixng in replacement of 150 mm bore sluice valve type PN-1 double Flanged cost iron type with steel spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engr-In-Charge.
155All as per Srl item No 114.00above butof Size 100 mm bore complete all as specified and directed by Engr-In-Charge.
156All as per Srl item No 114.00 abovebutof Size 80 mm bore complete all as specified and directed by Engr-In-Charge.
157Periodical mainteneance of DG Set any capacity upto 100 KVA by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator , , engine oil, cleaning of diesel tank , cleaning of radiator as recommended by manufacturer existing make complete all as specified and directed by Engr-in-charge . (Note :- Fuel filter , Lub oil filter , by pass filter , air filtershall be replaced if required under respective items of this Sch under).
158Supply only following items No 118.00 to 118.0 to be fixed under items No 117.00aboveDG Set of any cap upto 100 KVA , existing makeinstalled including taking out unserviceable items:- (a) Fan beltcomplete all as specified and directed by Engr-In-Charge.
159(b)V Belt complete all as specified and directed by Engr-In-Charge.
160(c) Lub oil filter complete all as specified and directed by Engr-In-Charge.
161(d)Fuel filter element complete all as specified and directed by Engr-In-Charge.
162(e)By pass oil filter complete all as specified and directed by Engr-In-Charge.
163(f) Air cleaner, inner element and outer complete all as specified and directed by Engr-In-Charge.
164Supply and fixing in replacement of maintainance free battery 12 volt 180 AH tubuler type including battery lead and intial charging of battery complete all as specified and directed by engr in charge
165Checking and repairwiring of control panel /AMF Panel including replace of defectivewireand testing complete all as specified and directed by Engr-In-Charge.
166Supply and fixing in replacement of Over/under voltage Relay 3 phase 415 volts AC existing make as directed by Engr-in-Charge
167Supply and fixing in replacement of Engine starting / stopping Relay 12 / 24 Volt DC existing make complete all as specified and directed by Engr-In-Charge.
168Supply and fixing in replacement of AC Timer 230 Volts having adjustment 0-60 Seconde existing make complete all as specified and directed by Engr-In-Charge.
169Supply and fixing in replacement of DC Timer 12/24 Volts having adjustment 0-60 Seconde .complete all as specified and directed by Engr-In-Charge.
170Supply and fixing in replacement of Cranking Relay 12/24 V.complete all as specified and directed by Engr-In-Charge.
171M/LHigh pressure pipeas per sample complete all as specified and directed by Engr-In-Charge.
172M/L radiator hose pipe as per sample complete all as specified and directed by Engr-In-Charge.
173Replacement of tripping coil 24 Volts as per sample complete all as specified and directed by Engr-In-Charge.
174M&L coolant complete all as specified and directed by Engr-In-Charge.
175M&L Distilled water for battery refilling complete all as specified and directed by Engr-In-Charge.
176M&L for head gasket kit for DG Set any cap as per sample complete all as specified and directed by Engr-In-Charge.
177Repair to self starter with replacement of carbon brushes,pinion,rewinding of starter and rotor winding ,replacement of defective bents etc to make the starter fully serviceable and testing for DG Set any make any size complete all as specified and directed by Engr-In-Charge.
178Repair to DG Set control panel any type incl replacement defective sensors like AMF module , relay card /board ,current transformer ,key switch , indiators , warning ,push button and checkingwiringcomplete including made functional all the system/controlscompleteall as specified and directed by Engineer in charge
179Repair to battery charger upto 60 Volt including rewinding of transformer of charger, repair/ replacement of rectifier assy, switches, ammeter, voltmeter etc complete all as specified and directed by Engr-In-Charge.
180Repair to radiator assy Cleaning washing thoroughly, de- scaling and M&L for replacement of rubberize paid and MS Nut & Bolts including brazing /repair of cooling tubeswith dismantling and segregation upper and lower chamber (tank) includingand reassemblingany type any capacity complete all as specified and directed by Engr-In-Charge.
181Supply anf fixing of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA complete all as specified and directed by Engr-In-Charge.
182Supply anf fixing of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA complete all as specified and directed by Engr-In-Charge.
183Supply anf fixing of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-In-Charge.
184Removal of vegetation/undergrowth/bushes in the premises of E/M installations by using mechanical bush cutter where deemed necessary and cleaning the creepers growing on fencingof the installation once in a month and removal of waste vegetation to nearest dustbin or location as decided with periodicity of once in a month complete all as specified and directed by Engr-In-Charge. (Note: Any T&P and transportation required for removal of vegetation from installation is deemed to be included in the quoted rates, contractor is advised to quote rate accordingly.)
185Chain pulley block with triple spur gear, grade 80 alloy steel load chain and zinc plated hand chain with load capacity 5 ton, standing lifting height 3 mtr, no. Of fall 2, load chain length 6 mtr, load chain diameter (10x30mm) all as specified and complete all as specified and directed by Engr-In-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy