}

Tender For Various Work At Blood Bank In Pbm Campus Bikaner, bikaner-Rajasthan

Medical And Health Services -MAHS has published Tender For Various Work At Blood Bank In Pbm Campus Bikaner. Submission Date for this Tender is 27-02-2023. Retaining Hardware Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36432578
Tender For Various Work At Blood Bank In Pbm Campus Bikaner
Open Tender
Indian
Rajasthan
bikaner
27-02-2023

Tender Details

Tender For Various Work At Blood Bank In Pbm Campus Bikaner - Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Upto 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area Cleared. 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils 3 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) . 4 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 5 Providing And Laying In Position Specified Grade Ofcement Concrete Forall Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 6 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 7 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix 8 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 9 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchorblocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. 10 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. 11 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. ( Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786 ) Thermo-Mechanically Treated Bars ( Conforming Of Relevent Is Code ) 12 Brick Masonry With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth With Bricks Cement Mortar 1 : 6 ( 1 Cement : 6 Coarse Sand ) 13 Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In.Cement Mortar 1 : 6 ( 1 Cement : 6 Coarse Sand ) 14 Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In.Cement Mortar 1 : 6 ( 1 Cement : 6 Coarse Sand ) 15 Grading Roof For Water Proofing Treatment Withwater Proffing Compoundcement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 16 Making Khurras 450 X 450Mm With Average Minimum Thickness 50Mmcement Concrete 1 : 2:4 Over P.V.C. Sheet 1 Mtr. X 1 Mtr. X 40Micron Finished With 12Mm Cement Plaster 1 : 3 And Onecoat Of Neat Cement, Rounding Edges And Making And Finishing The Out Let Complete. 17 Providing&Fixingprecastcementconcretecoping1:2:4Mix50mmthickcompleteas Per Specification : 18 Providing Gola 75X75 Mm In Cement Concrete 1:2:4 ( 1 Cement : 2Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge ) Includingfinishing With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) As Per Standard Design : 19 Providing And Fixing Unplasticized Poly Vinyl Chloride ( Upvc ) Swr Pipes Type B For Sciland Waste Discharge System ( Is:13592 : 1992 Marked ) Of Approved Quality / Make110 Mm Dia 20 Providing And Fixing Unplasticized Poly Vinyl Chloride ( Upvc ) Swr Pipes Fittings Type B For Sciland Waste Discharge System ( Is:13592 : 1992 Marked ) Of Approved Quality / Makecoupler 110Mm Dia 21 Providing And Fixing Unplasticized Poly Vinyl Chloride ( Upvc ) Swr Pipes Fittings Type B For Sciland Waste Discharge System ( Is:13592 : 1992 Marked ) Of Approved Quality / Makesingle Tee 110Mm Dia 22 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats, Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide 23 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20Mm Thick. 24 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete 25 Providing And Applying White Cement Based Puttyover Plastered Surface To Prepare The Surface Even And Smooth Completenew Plastered Surface ( Three Or More Coats ) 26 Painting Exterior Surface Ofwallwith 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Prepartion Of Base With Sand Papering, Primer, Putty, Etc Complete In All Respect Including Scaffolding And Safety Provision New Work 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : Two Or More Coats On New Work 28 Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layerson Prepared Surface, Mixing By Manual Mean Method At Omc, And Compacting With Smoothwheelroller To Achieve Thedesired Density, Complete As Per Morth Specification Clause 401. With Lead Of Material Up To 20.00 Km.From Quarry For Grading Iii Material 29 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) . 30 Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 100 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 410. With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks.Category B : Dentated Only Two Side Like I, Z, T Shape As Per Irc:Sp:63-2004 31 Kerb Stones Of 1200X300x150, 1000X450x150, 1000X600x150, 600X300x150 Size ( M-30 ) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade ( Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W / C Ratio In Concrete Mix. Manufactured With Steel Moulds ( Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy ) On Steel Base Plate Of Min 16 Mm Thick;Having Vibration And Pressing Action Both Together Withthe Help Of Multiple Synchronised Vibrators.Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System ) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Including Making Of Joints, Drainage Opening Wherever Required. 32 Rewiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) In Recessedisi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked ( Is:3419-1988 ) Accessories, Round Tiles, 1.2 Mm Thick Ms Box With Earth Terminal, 6 A Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector , 3.0 Mm Thick Isi Marked ( Is:2036-1995 ) Phenolic Laminated Sheet, Al.Alloy / Cadmium Plated Iron / Brassscrews, Cup Washers, Making Connections, Testing Etc. As Required. For Specification Of Copperconductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point ( Up To 3 Mtr. ) 33 Medium Point ( Up To 6 Mtr. ) 34 Long Point ( Up To 10 Mtr. ) 35 Wiring Of 3 / 5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Sizefr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Inrecessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked ( Is:3419-1988 ) Accessories, Hot Dipped Galvanizedmodular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modularswitch, 3 / 5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 36 S&F Following Sizes ( Dia. ) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along Withisi Marked ( Is:3419-1988 ) Accessories As Requiredinrecessincludingcutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 20 Mm 37 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130 / Iec 60228 Forlower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A / C / D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 38 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 39 P & F Phenolic Laminated Sheet 2.0 Mm Thick Of Following Size . Including Screws, Cup Washer As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 75 Mm Dia 40 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load Andsite Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Ofclass 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted Inexisting Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Ratingincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb ( With B / C Curve Tripping Characteristics ) 6 A To 32 A Rating 41 Double Pole Mcb ( With B / C Curve Tripping Characteristics ) 6 A To 32 A Rating 42 Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed ) Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door ( For Double Door Db Only ) 100 Amp. Insulated Copper Bus Bar / Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Metal Door ( Three Phase ) Ik-09 And Ip-43With Metal End Box 6 Way 43 Supplyandinstallationofhigh Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copperthickness ( 250 Microns ) Andconfirming Toul 467, Is / Iec 62561-2Of Following Size And Length And As Per Point Mentioned ( A ) , ( B ) , [ C ) , ( D ) , ( E ) Below :- ( A ) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole ( B ) Filled With Anti Corrosiveconductivecompounds With The Permanent Sealings At Both The Ends, Cpri / Erdatested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Labfor Lowresistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Contentas Per Referance Of Is 3043-1987, Ieee 80-2013 ( Clause 14.5D ) , Ieee 837 & Ier 1956 With Latest Amendemnts© Connect The Rod With Copper Strip / Conductor / Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt ( D ) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height250 To 300 Mm. ( D ) Testing Of Earth Resistance For Value Of 5 Ohms Or Lessas Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. ( E ) Test Certificatesfor Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr .17.2 Mm Thick And 3 Mtr. Long 44 Providing & Fixing Ofbeestar Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallicblade Ceilingfanconforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing ( I.E. Isi Marking ) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope ) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 1200 Mm Sweep Bee 3 Star Rated ( Service Value >=5.0 To< 5.5 ) 45 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminiumhousing With In Built Driver, System Lumen Efficacy = 110 Lm / Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection , Thd < 10% , P. F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 1170Mm ( + / -10% ) Led Batten With Min. Lumen Output 2200 Lm 46 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmouredaluminiumcable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv Withh4- Grade Electrolyticaluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench / Cable Tray ( With Cable Tie ) Includingtesting Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6.0 Sq. Mm 4 Core 47 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminummaterial With Heat Dissipation Fins On Housing With Uv Stabilized Pc ( Uv Stablization Report Submitted For Uv Cover ) / Toughened Glass Coverand Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm / Wt And Potted Driver& Has A Unique Bis R Number Withinput Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driverefficiency >85%, Thd ( I ) <10%Humidity 10% To 90% Rh Working Temp -5C To 45C .Driver Current <750Ma. The Luminaireshall Be Bis Certified And Trade Mark Certified. Life Expectancyequal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs.Manufactures Word Mark / Name Engraved / Embossing On Die Cast Housing To Allow Traceability / Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities Forled Fixtures. ( Lm79 / Lm80 ) Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 8700 Lm

Key Value

Document Fees
INR 500 /-
EMD
INR 51000.0 /-
Tender Value
INR 25.50 Lakhs /-

BOQ Items

Name of Work: Various work at Blood Bank in PBM Campus Bikaner
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
2Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
3Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
4Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size).
5Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
6Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
7Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix
8Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
9Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.
10Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc.
11Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ("Original producers" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code)
12Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand)
13Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)
14Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)
15Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
16Making khurras 450 x 450mm with average minimum thickness 50mmcement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and onecoat of neat cement, rounding edges and making and finishing the out let complete.
17Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification :
18Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
19Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make110 mm dia
20Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler 110mm dia
21Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeSingle Tee 110mm dia
22Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
23Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick.
24Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
25Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats)
26Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision New Work
27Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
28Construction of granular sub-base by providing well graded material, spreading in uniform layerson prepared surface, mixing by manual mean method at OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per MoRTH Specification Clause 401. With lead of material up to 20.00 km.from quarry For Grading III Material
29Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
30Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 100 mm as per drawings and as per IS 15658:2006.and all materials shall conform to MoRTH Specification Clause 410. with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks.Category "B" : Dentated only two side like I,Z,T shape as per IRC:SP:63-2004
31Kerb Stones of 1200x300x150, 1000x450x150, 1000x600x150, 600x300x150 size (M-30)Providing and Laying cement concrete Kerb Stones of different sizes in M-30 grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds (Milled and manufactured in CSI diamond or CSI Nitro process for accuracy) on steel base plate of min 16 mm thick;Having Vibration and pressing action both together withthe help of multiple synchronised vibrators.Power of hydraulic station should be minimum 50KW for compaction and cured in controlled chambers having humidity control and automated air circulation system) in position to the required line, level and curvature jointed with cement mortar 1:3 (1 Cement : 3 Coarse sand) including making of joints, drainage opening wherever required.
32Rewiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessedISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/brassscrews, cup washers, making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR Short point (up to 3 mtr.)
33Medium point (up to 6 mtr.)
34Long point(up to 10 mtr.)
35Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR On board
36S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR 20 mm
37Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure "A" attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm
382 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
39P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR 75 mm dia
40Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating
41Double pole MCB(With B/C curve tripping Characteristics)6 A to 32 A rating
42Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp.  insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, Ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR Metal door (Three phase) IK-09 and IP-43with Metal end box 6 Way
43Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole(b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .17.2 mm thick and 3 Mtr. Long
44Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
45Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm
46Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure "A" attached with this BSR 6.0 Sq. mm 4 core
47Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . LED Street Light fixture with Minimum lumen output 8700 lm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail