}

Tender For Maintenance And Operation Of 02 X 50 Kwp Solar Power Plants Installed At Aizawl Of Hq 23 Sector Ar., Aizawl-Mizoram

Assam Rifles-AR has published Tender For Maintenance And Operation Of 02 X 50 Kwp Solar Power Plants Installed At Aizawl Of Hq 23 Sector Ar.. Submission Date for this Tender is 07-03-2023. Solar Power Plants Tenders in Aizawl Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

36430209
Tender For Maintenance And Operation Of 02 X 50 Kwp Solar Power Plants Installed At Aizawl Of Hq 23 Sector Ar.
Open Tender
Indian
Mizoram
Aizawl
07-03-2023

Tender Details

Maintenance And Operation Of 02 X 50 Kwp Solar Power Plants Installed At Aizawl Of Hq 23 Sector Ar.

Key Value

Document Fees
INR 1000 /-
EMD
INR 31239.0 /-
Tender Value
INR 15.61 Lakhs /-

BOQ Items

Name of Work: Maintenance and operation of 02x50 KWP Solar power plant installed at Aizawl of HQ23 Sector AR
Sl. No. Item Description
1Maintenance and operation:- Maintenance and operation of 02 Nos of 50 KWP solar plants alongwith its connected equipments i.e control panels, battery banks and pv modules etc in shifts of 08 hours per day by employing qualified or experinced technician including comprehensive maintance of all above equipment installed at solar distribution network in HQ 23 sector area by maintaining attandence register of staff empoyed all as specified and directed by Engr-in-charge. Contractor quote his rate for maint and operation of 02 Nos solar plants and all other eqpt including cleaning of plant areas, monitring/recording of plants energy, production/distribution details with following terms and condition. (a) Contractor will produce character certificate issued by police station, Education/qualification and experince certificate belonging minium 02 years of the staff empolyed and contractor shall be responisble for any disciplinary casefstaff employed.(b) Necessary life insurance will be done as per preveling rules for tradesman employed through this job and original policy documents will be produced for verification and record of the accepting officer immedietely on after approval of technician. (c) All expenditure for necessary T&P, dress, safety hardness Eqpt, communication, stationary, insurance of tradesman etc as per specifed in this job are deemed to be included in the quotes rate. (d) All payments of labours will be done through Nationlize banks and produced the bank statement to department before claming bill. (e) PENAL CHARGES:- If any of the activity mentioned above is not performed by the contractor than recovery as under will be affected:-(i) Absent on duty of technician- Rs 1000 per shift.(ii) Not cleaning of PV Modules and plant ara- Rs 2500 per plant/month. Note: The spares part replaced under comprehensive maintenance shall be measured and paid seperately
2Supply, installing, testing and commissioning of array junction Box (AJB) as per existing size/capacity complete all asdirected and specified .
3Supply, installing, testing and commissioning of Field junction Box (FJB) as per existing size/capacity complete all asdirected and specified
4Supply, installing, testing and commissioning of Main junction Box (MJB) as per existing size/capacity complete all asdirected and specified
5Supply, installing, testing and commissioning of PV module (photo- voltaic cell) as per existing size/capacity complete all asdirected and specified
6Supply, installing, testing and commissioning of PV circuit breaker PC Box of 250 Amps capacity complete all asdirected and specified
7Supply, installing, testing and commissioning of DC/AC voltage meter as per exsiting size/capacity complete e all asdirected and specified
8Supply, installing, testing and commissioning of DC/AC Ampere meter as per exsiting size/capacity complete e all asdirected and specified
9Supply, installing, testing and commissioning ofsolar E/Fax as perexsiting size/capacity complete e all asdirected and specified
10Supply, installing, testing and commissioning of solar DC cable of 6.0 sqmm complete e all asdirected and specified
11Repair and maint of old existing inverter of system voltage 240/360/480 Volts by inspecting, repair of replacemnt of internal parts complete alongwith DC wiring connection, PCBs, indicators, volt and Amp meter (Digital/analogue type) and make the inverter functional by comnnecting to existing bty bank all as specified and directed.
12Fixing only bty bank of suitable capacity (500/600/1000 AH) from store room to solar plant site and connecting in existing system by taking down old unserviceable bty bank from system complete and make the plant functional in all respect incl. connection upto inverter complet all as specified and directed. Note:(1) The new battery (500/600/1000 AH) will be supplied as schedule "B" Stores free for fixing only. (2)The old battery bank is issued as schedule of credit to the contractor.(3) The battery bank qty is 180 or 240 Nos.
13Supply ,installing,testing and commissioning of 70sqmm completeall as specified and directed.
14Supply ,installing,testing and commissioning of SolarDC cableof 16.0 Sqmm completeall as directed and specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail