Tender For Providing Lis Rahud Khad To Karyal In G.P. Darbhog Tehsil And Distt. Shimla Hp (Sh-Site Development C/O Retaining Wall To Protect The Pump House And Sump Well 3 Mtrs. C/O Rcc Anchor Block For R/Main, Hdpe Pipe In Distribution System, Pump, shimla-Himachal Pradesh

Irrigation And Public Health Department has published Tender For Providing Lis Rahud Khad To Karyal In G.P. Darbhog Tehsil And Distt. Shimla Hp (Sh-Site Development C/O Retaining Wall To Protect The Pump House And Sump Well 3 Mtrs. C/O Rcc Anchor Block For R/Main, Hdpe Pipe In Distribution System, Pump. Submission Date for this Tender is 09-03-2023. Tanks and Cylinders Tenders in shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36422351
Tender For Providing Lis Rahud Khad To Karyal In G.P. Darbhog Tehsil And Distt. Shimla Hp (Sh-Site Development C/O Retaining Wall To Protect The Pump House And Sump Well 3 Mtrs. C/O Rcc Anchor Block For R/Main, Hdpe Pipe In Distribution System, Pump
Open Tender
Indian
Himachal Pradesh
shimla
09-03-2023

Tender Details

Providing Lis Rahud Khad To Karyal In G.P. Darbhog Tehsil And Distt. Shimla Hp (Sh-Site Development C/O Retaining Wall To Protect The Pump House And Sump Well 3 Mtrs. C/O Rcc Anchor Block For R/Main, Hdpe Pipe In Distribution System, Pump House Cum Attendant Quarter, Rcc Sump Well/Delivery Tank, Storage Tank 175000 Ltrs. Cap.C/O Outlets/B.P. Tanks 15 Nos. Laying And Jointing Of Feeder Line, Prov. And Laying Of Rising Main 150Mm Dia And Supply And Errection Of Pumping Machinery With Allied Acce

Key Value

Document Fees
INR 1500 /-
EMD
INR 227620.0 /-
Tender Value
INR 1.95 Crore /-

BOQ Items

Name of work:Prov. LIS Rahud Khad to Karyal in G.P.Darbhog Tehsil & Distt.Shimla.H.P. (SH:-Site Development,C/O Retaining wall to protect the pump house and Sump well 3 mtrs. C/O RCC Anchor Block for R/Main, HDPE pipe in distribution system , Pump house cum attendent quarter, RCC Sump well/ delivery tank, Storage tank 175000 ltrs. cap. C/O outlets/B.P.Taks 15 Nos. Laying and jointing of Feeder line, Prov. and laying of Rising Main 150mm dia and Supply and errection of pumping machinery with allied accessories ).Estimated cost:- Rs.19511576/-Earnest Money:- Rs.227620/-Time:- 1 year.
Sl. No. Item Description
1CIVIL WORK:
2Cutting in earth work in all kinds of soil such as pick work, jumper work, blasting work soft/hard rock or chiselling work etc. and disposal of excavated earth as directed within all leads and lifts.
3Excavation in foundation, trenches,etc. in earth work in all kinds of soil such as pick work, jumper work, blasting work, hard blasting and chiselling etc. stacking the excavated soil not more than 3 mtrs.clear from the edge of excavation and then returning the stacked soil in 15cm.layers when required into plinths sides of foundations etc.then disposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads and lifts.complete in all respect and to the entire satisfaction of the Engineer-in-charge.
4Excavation in drains and channels etc. in earth workfor pipes upto all depth in all classification of earth work such as pick work, jumper work, saturated soil including balling or pumping out water, blasting soft/hard rock or chiselling soft/hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming and dressing of sides, levelling of beds to correct grade including shoring/ struting, planking, timbering and dewatering wherever required stacking the useable/unusable material/soil separately and after laying and joining and testing of pipes, returning the useable soil in trenches in 15cm. layer including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for acess to houses, fencing etc. complete in all respect within all leads and lifts as per direction of the Engineer-in-charge.
5Providing and laying cement concrete 1:4:8 (1cement: 4sand: 8graded stone agg. 40mm nominalsize) and curing complete excluding cost of form work i/c all leads and liftsin foundation and plinth.
6Providing and laying cement concrete work 1:1 1/2: 3(1cement:1 1/2sand:3 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge.
7a) In foundation and plinth.
8Walls (any thickness) but not less than 0.1 m thickness) including attached pillasters,buttresses, plinth and string courses etc.from top of foundation level upto floor two level.
9Providing and laying cement concrete work 1:2:4(1cement:2sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work i/c all leads and lifts complete in all respect. :-
10Foundation footings, bases of column and the like and mass concrete.
11Column, pillars posts and struts upto floor two level.
12Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level.
13Stair cases (except spiral stair cases) excluding landing but including preparing of the surface and finishing of nosing upto floor two level.
14Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone agg.40mm nominal size) and curing complete excluding cost of centringand shuttering In foundation and plinth within all leads and lifts as per direction of Engineer-in-charge.
15Providing and laying cement concrete 1:5:10 (1cement:5sand:10 graded stone aggregate of 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150 mm to 300 mm as per H.P.P.W.D specification including all leads and lifts
16Providing form work with steel plates 3.15mm thick weldedwith angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 3 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work in complete in all respect i/c all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
17Foundation,footings, basis of columns, etc. and mass concrete.
18Flat surfaces such as soffits of suspended floors,roofs, landings, and the like:-i)Floors etc. upto 200mm in thickness.
19Vertical surfaces such as walls (any thickness), partitions and the like including attached pillasters, buttresses, plinth and string courses and the like.
20Edges of slabs and breaks in floor and wall:- Under 20cm wide.
21Column Pillars, posts and strutssquare rectangular polygonal in plan.
22Beams, cantilevers, girders and lintels:- Sides and soffits of beam, beam haunching scantilevers, bressumers and lintels not exceeding 1 mtrs. in depth in all height fromfloor.
23Slopping or battering surfaces including folded plates: Where inclination to horizontal plane exceeds 30 degrees.
24Stair cases with sloping or stepped soffits excluding landing.
25Stone filling behind the retaining wall/breast wall.
26Providing and fixing of PVC pipe 50mm dia for weep hole complete in all respect.
27Providing Mild steel/Tor steel reinforced for RCC work including bending, binding and placing in position complete upto floor two level i/c all leads and lifts complete in all respect. Tor steel.
28Providing 200mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in manholes with 200mmx 200mmx 100mm cement concrete 1:3:6 (1cement: 3sand:6graded stone agg. 20mm nominal size).complete in all respect i/c all leads and lifts.
29Laying and jointingin trenches,galvanised mild steel tubes (Light grade) i/c tube fittings such as Tee, elbow, union & nipple.(earth work in trenches to be measuredand paid for separately) i/c all leads and lifts complete in all respect.Labour rate only.
30100mm dia nominal bore for scour pipe for inlet and outlet pipe.
31Providing and fixing brass full way valve with wheel of superior quality complete in all respect.
3280mm dia.
3365mm dia.
34100mm dia for scour pipe and inlet and outlet pipe.
35150mm dia.
36Providing wood work in frames of doors, windows clerestory windows and other frames wrought framed and fixed in position:-2nd class deodar wood.
37P/F panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows including black enamelled ironbutt hinges with necessary screws complete in allrespect as per the direction of the Engineer-in-charge i/c all leads and lifts.40mm thick deodar wood 2nd class.
3815mm cement plaster in single coat on fair side on brick/concrete/stone walls for interior plastering upto floor two level including arrises, internal rounding angles, chamfers and or rounded angles not exceeding 80mm in girthand finished even and smooth:- Cement mortar 1:6.
3920mm cement plaster in single coat,on rough side of bricks/stone walls for interior plastering uptofloor two level including arrises internalrounded angles, chamfers, and/or roundedangles not exceeding 80mm in girth and finished even andsmooth:-a)In cement mortar 1:6(1cement:6sand ) including all leads and lifts.
406mm cement plaster to ceiling:-a) In Cement mortar 1:3(1cement:3sand).
41White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt, dust , mortar dirt and other foreign matter as per the direction of Engineer-in-charge including all leads and lifts.
42Distempering two coats with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and i/c a priming coat with distempering primer of approved brand and manufacture after thoroughly brushing the surface free from mortor dropping and other foreign matter and also i/c preparingthe surface even and sand papered smooth.Priming coat with distemper primer with in all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge.
43Finishing wall with water proofing cement paint or approved brand and manufacture and of required shade on undecorated wall surfaces two coats to give an even shade after thoroughly brushing the surface to remove dirt, loose or softened paint including all leads and lifts.
44Cement concrete flooring 1:2:4(1cement:2sand:4graded stone agg.20mm nominal size) laid in one layer finished with a floating coat of neat cement:-a)40mm thick.
45Applying priming coat over new wood and other wood based surfaces after and includingpreparing the surface by thoroughly cleaning oil grease dirt and other foreign matter including all leads and lifts.With readymixed paint brushing wood primer pink.
46Painting two coats (excluding priming coat) on new wood andwood based surfafes, with ready mixed paint brushing to give an even shade including cleaning of all dirt dust and other foreign matter,sand papering and stopping:-including all leads and lifts.With readymixed paint other than white.
47P/F M.S. grills of required pattern in wooden frames of windows etc.with M.S.flats square or round bars with round headed bolts and nuts or by screws complete in all respect including all leads and lifts as per the direction of the Engineer-in-charge. Plain grills.
48Stone soling properly filling interstices with spalls and condolidating with power road rollerto the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc.100mm spread thickness including all leads and lifts (finished work including materials and labour).
49Providing and fixingM.S.sliding door bolts bright finished or/ and black enamelled with nuts and screws etc.complete i/c all leads and lifts and as per direction of Engineer-in-charge.300x 16mm.
50Providing and fixing M.S.Tower bolts (barrel type) with necessary screws etc. complete i/c all leads and lifts and as per direction of Engineer-in-charge.150x10mm.
51Providing and fixingM.S. handles with necessary screws etc. complete i/c all leads and lifts and as per direction of Engineer-in-charge.100mm.
52Providing 40x3mm flat iron hold fast40cm long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm.1:3:6 (1cement: 3sand:6graded stone agg. 20mm nominal size).complete in all respect as per the direction of the Engineer-in-charge including all leads and lifts.
53Providing plinth protection 50mm thick in cement concrete 1:3:6(1 cement :3sand:6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth including all leads and lifts.
54Providing under layer of plinth protection of75mm thick (unconsolidated) bed dry brick/stone agg. 40mm nominalsize with rammed and consolidated and grouted with fine sand includingpreparation of groundi/c all leads and lifts and as per direction of Engineer-in-charge.
55Steel work welded in built up sections, trusses and framed work including cutting hoisting, fixing in position and applying a priming coat of red lead paint:
56In grating, framed guard bars, ladders, railing, brackets and similar works.
57Providing and fixingfinolex pipe 40mm dia under floor including all leads and lifts complete in all respects.
58Laying and jointing high density polyethene pipes for use of buried water mains and services and forwater supply above ground, both inside and outside building duly ISI marked (IS: 4984-1995 as amended upto date in the following grades of material, pressure rating and nominal dia Material grade PE-80 PN-6 including all leads and lifts as directed by the Engineer-in-charge.
5963mm dia PE-80 PN-6.
6075mm dia PE-80 PN-6.
6190mm dia PE-80 PN-6.
62110mm dia PE-80 PN-6.
63Providing and fixing C.I.sluice valve/scour valve (with hand wheel) as per IS:780-1984 class I upto 300mm dia (including brass spindle and as per IS:2906 class II for diameters more than 300mm complete with bolts, nuts, rubber insertion etc., (The tail pieces if required shall bemeasured and paid for separately):-
64100mm.
65125mm.
66RISINGMAIN:-
67Providing laying, jointing and testing of plain ended API Pipes with steel grade, X-56and X-42 conforming to ISO-3183 of equivalent API-5L grade "A" of thickness as mentioned and grade designation with bevelled edge and capable of with standing required test pressure, in a random length of 4-7 metres i/"c testing and commissioning and cost of jointing with butt welding as per relevant BIS specification ( leak proof) flange shallbe provided at every 100 mtrs.) i/ccost of bends tail pieces, tees, reducers, increasers etc. as per site requifrement and zinc. coating as per IS:4736-1986. as per the direction of the Engineer-in-charge i/c all leads and lifts.
68150mm dia L-390 X-56 Wall thickness 5.60mm
69150mm dia L-390 X-56 Wall thickness 4.80mm
70150mm dia L-290 X-42 Wall thickness 4.80mm
71Laying and jointing in trenches galvanised mild steel tube ( Medium/Heavy grade) of following diameters confirming to IS-1239 as specified below plain ended jointed with butt welding according to relevant BIS code 816-1969 including all short pieces bends,tee and other specials etc. made from parent tubes as applicable for the particular reach and of approved specifications as per site conditions including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should confirm to BIS code 5822-1970 within all leads and lifts complete in all respect.
72150mm dia nominal bore for scour pipe.(Medium grade).
73150mm dia nominal bore(Heavy grade).
74Providing fixing and jointing of M.S.flanges conforming toBIS-6392-1971(latest with upto date ammendment ) flange dia, table and nominal pressure as specified below welded at both ends of pipes at an interval of 100 mtrs.(as per site condition for particular reach as required) according to relevant BIS Code 816-1962 and provided with nuts and bolts of required size as per BIS code 1364 including 3mm thick compressed asbestos fiber gasket of synthetic rubber gasket conforming to relevant BIS code 2712-1965 complete in all respect including all leads and lifts.
75150mm dia.Table.34
76Table.28
77Table.17
78Table. 5
79Providing and fixing of Cast steel Sluice valve of Leader/Kirloskar make 150mm diaASA-300havingbye pass arrangement for delivery line of pump and capable of with standingnormal seat pressure as per IS:5312-1884 (P-I)Class ASA-300with upto date ammendments cmplete in all respect as per the direction of the Engineer-in-charge.
80Providing and fixing of cast steel Non return valve of Leader/ Kirloskar make of 150mm dia having bye pass arrangement on the delivery line of pump and capable of with standing the normal seat pressure as per IS:5312-1884 (P-I)Class ASA-300 with upto date amendmentcomplete in all respect as per the direction of the Engineer-in-charge.
81Pumping Machinery
82Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumpsor combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyotior any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting Raw water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze. shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/GEC/ Siemen/ Jyoti/ABBor any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)15% of the duty point head. The motor should be as per IS:325-1978with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
83Duty conditions for each set:-(I) Discharge (Q) 9.33 LPS.(ii) Total Dynamic Head:-650.09 Meters.(a) LWL in sump well(h) :- 1000.00 Meters.(b) Shaft level :- 1000.00 Meters.©Level at discharge point : Meters.(d)Suction lift :- 0.00Meters.(e) Residual head:- 3.00Meters.(f) Static head:-620.00 Meters.(iii) Rising main(a) Length. 2200 Meters.(b)Dia :- 150mm.(iv)Pumping hours.20 hours.(v) Altitude of Installation aboveMSL Meters.(vi) Characteristics of water(a) Temperature oC(b)Abient Temperature oC©Turbidity Clear water (d) Alkalanity:Mg/CA CO3. e)Size of the solids.....mm (f) Others:-Pumps Specifications: i)Make:- .(ii) Model :- (iii) No.of stages :-.(iv)Material manufactures certificate to be appended (I) Head(H):- mtrs.(ii)Discharge(Qlps.(iii)BHP absorbed (iv)Efficiency(n):- .(v) NPSH(K)
84(b) Motors Specification:- I) Make:-.ii) Model:- iii) Motor rating (KW ):- .iv)Speed.:-
85© Coupling]
86(d)Base Plate ] .
87Supply of suitable direct on line/oil immersed star delta /ATS/Stator rotor starter of standard makesuch as MEI/Kilburn/Jyuoti/ Siemens/ Larson and Turbo conforming to BIS-8544-1979 latest with upto date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type overload release & dash pot, time lag,under voltage release with initial oil filling.
88Note:-Star delta starter upto 37.5 KW,ATS between 37.5 KW to 50 KW and starter rotor starter with slipring motor beyond 50 KW.
89Providing MS .sheet,16 SWG steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, comprising and capable of mounting the following accessories with all internal connections: The drawing of panel board shall be subject to approval of Engineer-in-charge.
90Ammeter AC supply 100mm dia circular dialAuto electrical AE/IMP/Havells make of suitable range for above motorwith selector switchesconforming to BIS:1248(P-II) 1983 with upto date ammendments.
91Voltmeter A.C. Supply 100mm dia circular dia Auto electric/AE/IMP/Havells make of suitable range with selector switches as per IS:4064-1978 with upto date ammendments.
92ICTP switches with HRC fuses ofKilburn/L&T/Siemens/Standard/Havells make and having Capacity 30% extra of the operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP SWITCHES: I) Type :ii)Make:- iii)CapacityAmp.
93Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and one copper bar of half the rating of full length for neutral phase as per BIS:8084-1976 and 11353-1985 read with 5578-1985 with upto date ammendments.BUS BAR CHAMBER:-i)Type: - . ii)Make:- iii)Rating
94ACB/M.C.B/Oil Circuit Breaker of suitable capacity of Kilburn/ L&T/ MEI/GEC/Standard make on incoming feeder for motor offeredby the tenderer conforming to BIS-2516-1985 latest with upto date ammendments with initial oil filling whenever required and neutral linked under voltage release.
95Three phase Indicating lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments.THREE PHASE INDICATOR:- i) Type:-ii) Make:- iii) Capacity.
96Earth leakage circuit breaker relay of recommended make such as (Kilburn/L&T/MEI/ GEC) conformingto BIS- 2516-1977 withuptodate ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection.The circuit should be equipped with magnet thermal release with metallic tape etc. It shouldalso befitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :-(CEI approved). ii)Type: iii) Range.
97Providing Hour run meter of reputed make for four digit capacity conforming to BIS:722(Latest edition)/recommendations.HOUR RUN METER:- I) Type:-ii)Make:- iii)Capacity:- Hrs.
98Suitable three phase voltage monitor relay with all protection and usual indicator and electric siren against single phasing No/ low voltage,high voltage& overloading and phase voltage difference as per IS:3842with upto date ammendments.
99Change over switch of reputed make and suitable capacity
100Single phase preventor of reputed make and suitable capacity conforming to IS:1248 (P-V)-1983 with upto date ammendments.
101Supplyof Kirloskar/Leader/KSB/fouress/pelicon make of cast steel double flanged sluice valve having sizeone size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressureconfomring to BIS/API-standards with upto date ammendments for delivery liine of pump).
102(Note:- The sluice valve shall conform to BIS-780-1984 latest with upto date ammedments. However, if the seat pressure exceeds the limits prescribed in BIS: 780 then the sluice valves shall be of Cast steel conforming toclass 150 ASA (Seat pressure 21 kg/cm^2) or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
103Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the normal delivery size of .pump and capable of withstanding nominal seat pressure& comforming toBIS/API standard with upto date ammendments for delivery line of pump.
104NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming toclass ASA-150 (seat pressure 21 Kg/cm^2)or class 300 ASA as per BS: 1414(API -600).
105Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal todia of rising main as mentioned above for withstanding nominal seat pressure.
106NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming toclass ASA-600 or class 600 ASA as per BS: 1414(ASA -600).
107Supply of Kirloskar/Jyoti/Standard/Kilburn/Bir/ Kartar/Pelicon make cast iron flanged /screwed type foot valve ( in case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow is not more than 2.50 mtr/sec. with strainerhaving net area of its openings equal to three to four times of X-sectional area of flow in suction pipe conforming to BIS- 4038-1986 or latestwith up to date ammendments including all leads and lifts.
108Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Iron double flangedsluice valve (In case suction is +ve ) for suction pipe having sizeone or twosize larger than the suction size of .pump such as velocity of flow in suction pipe is not more than 2.50 mtr/sec.withstrainer having net area of its openings equalto three to four times of X-sectional area of flow in suction pipe and conforming to BIS/API standard with upto date ammendments for delivery line of pump. (Not applicable as suction lift is involved).
109NOTE:- The sluice valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312then the reflux valves shall be of cast steel conforming toclass ASA-150 (seat pressure 21 Kg/cm^2)or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
110Providing laying,jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case ofnon acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
111Providing laying,jointing and testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/ accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case ofnon acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
112Providing and laying double loop earthing with G.I.wire and strips 600mmx600mmx3mm thick electrode complete with material such as charcoal and commonsalt G.I.Pipes thimbles nuts and bolts,digging of pits, G.I.Wiring and 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with upto dateammendments suitable for above motors and other electrical equipmentsi/c cost of carriage of material in all leads and liftsand as directed by the Engineer-in-charge.
113Supply and errection of floor/wall mounted power factor shunt capacitor conforming to BIS:2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ ICC make from busbar chamber to capacitor & also including L&T/Kilburn/Standard/ Siemens/ Havells make ICTP switches conforming to BIS:4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/ccost of carriage of material in all leads and lifts & as directed by Engineer-in-charge.
114Supply of 100mm dia circular dia pressure gauge of suitable range & standard make such as Fiebig/ Bourden/ Precision/PREGA with all accessories such as stop cock, copper tubing etc.conformfing to BIS: 3624-1987 or latest with upto date ammendments.
115Providing and fixing double flanged suction, delivery pipe and common header considering site requirement, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS:2712-1978 nuts and bolts as per 1264-1983 & special upto 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engneer-in-charge. The pipes shall be capable of with standing minimum 1.5 times the total pressureor total dynamic pressure+ surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs./sec. & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c cost of carriage of material in all leads and lifts and as per directed by the Engineer-in-charge.
116NOTE:-Actual laying to be done as per final drawings to be approved by the Engineer-in-charge.
117Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
118Installation of all the items appearing at Serial No.44.00 to 58.00 as per the systematic drawing attached with the tender documents (Drg. No.1).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail