| 1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.. |
| 5 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 15 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 16 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete . |
| 17 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 18 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 19 | Providing and fixing ball bearing for rolling shutters. |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. |
| 21 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete |
| 22 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand) |
| 23 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 24 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick |
| 25 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coatedhickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 26 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 27 | Barge board (Upto 300 mm). |
| 28 | Crimp curve |
| 29 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 30 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 31 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof |
| 32 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. |
| 35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 36 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 37 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 38 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. |
| 39 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 40 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 41 | Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres |
| 42 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos Cement sheet |
| 43 | Turbo ventilator |
| 44 | fastener (12 mm dia) 100 mm length |
| 45 | Deck Sheet |
| 46 | Point wiring in PVC conduit, with modular type switch - Wiring for light pointwith 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable inrecessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR/FRLS - Finolex, RRKable, Anchor, Havels or equivalent asapproved. Group B |
| 47 | Point wiring in PVC conduit, with modular type switch - Wiring for light pointwith 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable inrecessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR/FRLS - Finolex, RRKable, Anchor, Havels or equivalent asapproved.Group C |
| 48 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 8 Module (125mmX75mm) fo rcmmon15Alight Points |
| 49 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 6 Module (200mmX75mm) for 15Aout door lighting common switch |
| 50 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 3 Module (125mmX75mm) for LP1-lightpowerPoint |
| 51 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved.5/6amp modular switch on existing Switch box for LP1 |
| 52 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 5/6 amps modular socket on existing Switch box for LP1 |
| 53 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved.15/16 amps modular switch for common lighting switch |
| 54 | Circuit / submain /Light plug wiringin STEELconduit:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVCinsulated copper conductor, single core cable in surface / recessed STEELconduit as required.( for surface -Steel conduit will be spotwelded on the truss members as direcded)Wires : FR/FRLS - Finolex, RRKable,Havels or equivalent asapproved 2 x 1.5 Sq.mm + 1 x1.5 Sq.mm earth wire from 15A commmonswitch lighting points of corridor and warehouse insidelightingas directed. |
| 55 | 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire from DB to SB and common switch lighting / fan systemas directed |
| 56 | Supplying and fixing following way, single pole and neutral ways surface/ recess mounting,MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) as required. - for rooms. 12wayDouble door |
| 57 | Supplying and fixing 5 amps to 32 amps rating, 240 / 420volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.10 ampsto 32A Single pole |
| 58 | Supplying and fixing 5 amps to 32 amps rating, 240 / 420volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amps DP |
| 59 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 60 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required for each electrical room door . |
| 61 | Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings , complete with all accessories and tube etc. directly on ceiling/wall/ False ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 62 | Supply and fixing extra conduit down rod of 20 cm length G.I pipe of 15mm dia heavy gauge including painting etc. as required for installaiton of warehouse inside lighting.(Note ;More than 5 cm length shalll be rounded to the nearest 10 cm and 5 cm or less shall be ignored |
| 63 | Wiring for light point wiring alongwith earth wire with the following sizes of FRLS PVCinsulated copper conductor, single core cable in surface EXISTINGSTEELconduit as required. Wires : FR/FRLS - Finolex, RRKable,Havels or equivalent asapproved3 X 1.5 sq mm. |
| 64 | Supply of 70W LED CDL lamp set made of highly efficacy wellglass consuming lesser energy with hight lighting levels having an efficacy of 110Lm / W,protection of IP65. Make : CGL LWV12-70-CDL orequivalent Havells. Surya, Philips, Siskaas approved |
| 65 | 1 x 20 WLED6500K retrofitting polycarbinate T8tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 andfor batten unilite DMLN1LT8-16 or equivalentSiska orHavells , phillips, bajaj as approved.for small classroom lighting |
| 66 | Supply and installation of 40W NW (6K) LED street light along with 600 mm long 32mm diaGI arms with necessary clamps , nuts and bolts as required to install the lamp set on culm or stress members as directed .Make ; Siska - SSK -ST-40W SN or equivalent Havells, CGL , Surya, or philips as approved for building peripherallighting. |
| 67 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 5A SP MCB DIN bar, Earth bar ect. as reqiored with necessary anchor fastnerrequired to fit the box on the wall at required position or as directed . |
| 68 | Supply andistallation of 4.5 Kg, Mild steel ABC, A class powder/ CO2 type fire extenguisher |
| 69 | Earthing withG.I.earthpipe4.5metrelong,40mmdia cover plate having locking arangement and watereing pipe with charcoal / coke and salt as required for panel earthing and transformer body earthing. |
| 70 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 71 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 72 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmouredcable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEIOr equivalent as approved 3 Core, 6 sq.mm. Aluminiun conductorXLPEARMOUREDCable.for out door lighting |
| 73 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required.Up to35 sq. mm |
| 74 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to35 sq. mm |
| 75 | Supplying and embedding following G.I pipe of medium class for cable entry / road crossing of cable etc. including bending the pipe as required shape as required.b) 40 mm dia |