Military Engineer Services-MES has published Tender For Repairs/Maintenance Of Summer Cooling Appliances At Kattabomman And Rs(P) Under Ge Tirunelveli. Submission Date for this Tender is 14-03-2023. Air Conditioner Tenders in Tirunelveli Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing comprehensive annual periodical / preventive maintenance of cooling appliances as per manufacturer specification at INS Kattabomman, RS(P) all as specified and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (i) Cleaning of coil unit with dust blower, lubricate the indoor & outdoor fan motor with oil. (ii) Checking and cleaning the drain connection and air filter periodically, washing of coil with solution once in a contract period. (iii) checking the refrigerant pipe insulation once in a contract period or as and when required(iv) Check & repair the minor electrical fault in incoming supply. (v)Checking the drain water PVC pipe. (vi) Supply of spares/components required to be replaced under this contract shall be measure and paid separately. (vii) Checking the serviceability/ fault of cooling/ heating appliances for any fault/ unserviceability. |
2 | Supply and fixing of the following for 1.5/2.0 Ton capacity window/split type AC including testing and commissioning etc complete all as directed by Engineer-in-Charge. |
3 | Starting Capacitor 80/100 MFD. |
4 | Running Capacitor but 36 MFD. |
5 | Relay Assembly (Make: SRI RAM). |
6 | Over load protector (O L P) (Make: SRI RAM). |
7 | Thermostat (Make: RANUTROL/INDOFOSS). |
8 | Air filters (FIL/ UTILITY/ SPENCER/ VOLTAS/ AIRCON/ VIDEOCON/ SIDWAL). |
9 | Condenser fan blade metal or plastic. |
10 | Blower with circular leaf. |
11 | Fan capacitor (Make: SARADA/USHA/UNISTAR/KELTRON), 4/6 MFD. |
12 | Cabinet wiring Kit . |
13 | PVC insulated, sheathed3-core, 2.5Sqmm copper cable |
14 | Strainer tube (copper) |
15 | Non Return valve (For gas top up charging) |
16 | Capillary tube (copper) |
17 | Condenser coil unit (For A/C) |
18 | PCB board suitable for indoor unit of Split AC 1.5/2.0 TR |
19 | Supply and fixing the following for water cooler :- |
20 | Relay unit for water cooler. |
21 | PVC float Ball valve, high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15mm for water cooler |
22 | Thermostat switch for water cooler. (Make: RANUTROL/INDOFOSS). |
23 | Water tap push type suitable for water cooler |
24 | Supply and fixing the following for refrigerators :- |
25 | Relay unit for refrigerators. |
26 | Thermostat assembly for refrigerator. |
27 | Taking down, checking for serviceability and supply and fix new compressor including first filled Oil, cleaning the refrigeration system/pipe before installing with CO2 and charging refrigerant gas as required, providing/refixing if required NRV for further gas top up and re-fixing in the position including testing complete. |
28 | Window/ Split type AC 1.5 Ton capacity (Make: SRIRAM/ KIRLOSKER/ TECUMSHAW/ VOLTAS). |
29 | Window/ Split type AC 2.0 Ton capacity (Make: SRIRAM/ KIRLOSKER/ TECUMSHAW/ VOLTAS). |
30 | Water cooler 40/80 Litres capacity (Make: SRIRAM/ KIRLOSKER/ Voltas). |
31 | Refrigerators any capacity . |
32 | S&F Fan motor suitable for condenser unit of window/split AC complete with all accessories and fixing in position and testing the unit as directed by Engr-in-charge. |
33 | Taking down existing worn out fan from Split AC 1.5/2.0 TR AC fan motor and supply and fix motor of same capacity (single speed) with standard manufacturer specification including testing and commissioning complete all as directed by Engineer-in-Charge. (Make: LG/BLUE STAR/ VEDIOCON/ VOLTAS). |
34 | All as per item No.7 but for Water cooler. (Make: SRIRAM/ KIRLOSKER/ Voltas). |
35 | Taking out refrigerants ofACs 1.5/2.0 Ton capacity, Refrigerators and water cooler, cleaning the refrigeration system with CO2 and charging refrigerant gas M-22/F-22/R-134/R-410 or equivalent as per manufacturer recommendation and reassembling the system in original position complete testing and commissioning for the following all as directed by Engineer-in-Charge. |
36 | Split/window type AC 1.5/2.0 Ton capacity |
37 | Refrigerator 180 to 300 Litres capacity. |
38 | Water cooler 40/80 & 60/120 Litres capacity . |
39 | M&L for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPMCB including removal old unsv one complete all as specified . |
40 | Supply only for copper pipe ofsplit AC 1.5/2.0 ton capacitycomplete all as specified and directed by Engr-in-charge. |
41 | Taking down refrigerant of Split AC of any capacity by dismantling, checking for leakages at various places and fixing the indoor and outdoor units and making electric and copper pipe connection complete all as specified and directed by Engr-in-charge. (Note : - Spare parts replaced shall be measured and paid separately under relevant items.) |
42 | M&L sub main wiring with two single core 1100 V grade conforming to IS 694 PVC insulated unsheathed cables 4 Sq mm multi stranded copper conductor drawn through and incl 25 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm copper wire earth continuity conductor etc including taking down old sub main wiring complete all as specified and directed by Engr-in-Charge. Note : Three runs of 4 sqmm cable and one run of PVC conduit shall be measured as one run for payment. |
43 | Supply and fix PVC flexible drain pipe suitable for 1.5/2.0 TR split / window type AC complete all as specified and directed. |
44 | Dismantling of compressor of 320 Ltrs deep freezer and supply and fixing of compressor of specified make and capacity, type as per manufacturer specification and recommendation and all as specified and directed. Make: Blue Star. |
45 | Supply and fixing of compressor sealed unit for deep freezer 320 Ltrs as per Sample for Make: Blue star. ( KCL 411 ) |
46 | Supply and fixing of blower motor 1/9 HP 230 volt single phase Make: Unitech/Universal. |
47 | Supply and fixing of Thermostat for Deep Freezer 320 Ltrs Make Blue Star. |
48 | Supply and fixing of Top Gasket for deep freezer 320 Ltrs Make: Blue Star as per sample. |
49 | Supply and charging of refrigerant gas Maforn- R-134 to deep freezer including testing for required pressure complete all as directed by Engr-In-Charge. |
50 | Replacement of blower fan motors for desert cooler single phase 230 Volts 150 to 180 watts. |
51 | Replacement of submersible pump for Desert cooler 1.5 mtr head AC 230 Volts fixed in repairs. |
52 | Replacement of wood wool pads for desert cooler set of three of superior quality fixed in repairs. |
53 | Replacement of fan blade for desert coolers |
54 | Repair and over hauling of centrifugal type mono block condenser/chiller water pump (Make Kirlosker) of capacity 3 HP set including replacement of bearing impellor glands complete all as specified. |
55 | Material and labour for Opening and dismantling both sides covers of condenser and descaling of condenser unit 16.5 TR by pumping chemicals, brushing with rods, cleaning/ oiling of tubes, replacement of gasket and reassembling it after descaling complete all as directed. |
56 | Supply and charging gas refrigerant R 22Make : Mafron/Freonin the Central AC plant of cap16.5 TR all as specified and directed. |
57 | Schedule of credit amount brought back from Ser Page No.28- Rs.69,806.00will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail