Tender For Construction Of Public Toilet Outside Mmtc Road Before Footover Bridge In Ward No- 149 (Malviya Nagar)/South Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Construction Of Public Toilet Outside Mmtc Road Before Footover Bridge In Ward No- 149 (Malviya Nagar)/South Zone.. Submission Date for this Tender is 27-02-2023. Toilet Bathroom Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36385924
Tender For Construction Of Public Toilet Outside Mmtc Road Before Footover Bridge In Ward No- 149 (Malviya Nagar)/South Zone.
Open Tender
Indian
Delhi
Delhi
27-02-2023

Tender Details

Construction Of Public Toilet Outside Mmtc Road Before Footover Bridge In Ward No- 149 ( Malviya Nagar ) / South Zone.

Key Value

Document Fees
INR 590 /-
EMD
INR 49901.0 /-
Tender Value
INR 24.95 Lakhs /-

BOQ Items

Name of Work: Provision of E.I and fan in newly constructed Public Toilet (PT) near outside MMTC Road before FOB under South Zone.
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Supply of 12""(300 mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
3Supply,installation,testing and commissioning of Single /three phasemonoblock pumpset complete with all accessories workable on 240/415 Volts 50 Hz AC supply (a)01 HP (.75 KW) single phase pumpset head from 12-30 mtr suction and delivery 25X25 mm
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
5Wiring of circuit /submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in the surface/recessed medium class PVC conduit as required.2x2.5 sq mm +1 x 2.5 sq. Mm earth wire
6Wiring of circuit /submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in the surface/recessed medium class PVC conduit as required.2x4 sq mm +1 x 4 sq. mm earth wire
7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
9Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. including providing and fixing phenolic laminated sheet cover on the fan box etc.as required.
10Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
11Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way double door.
12Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole)
13Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral
14Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A
15Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
16Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
17Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
18Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
19Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 sq. mm
20Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
21Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
22Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
23Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required
24Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
25Supply of 1200 mm sweep 50 watt, Energy saver ISI marked BEE 5 Star rating AC Ceiling fan suitable for 230 V, 50 hertz AC supply without regulator with blades, downroad etc. complete as required.
26Supply ofXLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KVgrade Conforming to IS 7098 of following Sizes. 2C* 6 sqmm
27Supply of 250 mm (10"") sweep 1250 rpm exhaust fan Fresh Air Type complete with shutters, blades etc as reqd.
28SITC of 10W surface/Wall mounted LED Bulkhead factual impact dust and water resistant luminaires with IP-65/66 protection.
29S/I/T/C of LED Tube type Luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the followingExtruded Aluminium Batten prewired with high efficient LED with the following:(a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95