Housing Urban and Rular Development Government Departments Closing in 0 days TDR #36365064

Tender For Construction Of Child Development Planning Office Block At Danpur District Bulandshahr

Issued by Government Departments · danpur, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Mar 2023
0 days left
EMD
51000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
danpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Child Development Planning Office Block At Danpur District Bulandshahr

BOQ

Name of Work: Construction of Child Development Planning office Block at Danpur District Bulandshahr
Sl. No. Item Description
1Earth work in Excavation for structure as per drawing and techinical specifications clause 305:1 including setting out construction of shoring and bracing, rmoval of stumps and othe seleterious materials and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
2Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
3Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
4Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution)
5R.c.c. Work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 bwg. g.i. binding wire and including and neccessary centering and shuttering etc. and also including supply of all materials , labour and T&P etc. required for proper completion of the works binding wire cost being including in the item.All works upto plinth level
6M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
7Providing and laying damp-proof course 20mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size)
8Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
9P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
1015 mm thick plinth plaster [1 cement : 4 coarse sand]
11R.c.c. Work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 bwg. g.i. binding wire and including and neccessary centering and shuttering etc. and also including supply of all materials , labour and T&P etc. required for proper completion of the works binding wire cost being including in the item.All works above plinth levelGround Floor
12R.c.c. Work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 bwg. g.i. binding wire and including and neccessary centering and shuttering etc. and also including supply of all materials , labour and T&P etc. required for proper completion of the works binding wire cost being including in the item.All works above plinth levelGround Floor
13R.c.c. Work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 in Beam excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 bwg. g.i. binding wire and including and neccessary centering and shuttering etc. and also including supply of all materials , labour and T&P etc. required for proper completion of the works binding wire cost being including in the item.All works above plinth levelGround Floor
14Brick workin super-structure above plinth level up to floor two level (up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. 1:6 (1 cement : 6 coarse sand)Ground Floor
15Brick in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
16P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. Ground Floor
1712mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.Ground Floor
1812mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.Ground Floor
19Making grooves 10 to 12mmwide x8mm deep in plaster of the walls or in ceiling vertically or horizontally as required
20Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thickGround Floor
21Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.Ground Floor
22Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGround Floor
23Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mmGround Floor
24Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.Ground Floor
25Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.Ground Floor
26Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
27Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws(a) Single leaf
28(b) Double leaf-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
29Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws
30Hold fast for chaukhats of doors/windows.
31Door / windows & Staircase grill.
32Fabrication of Z-section steel window excluding glass panes
33Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)[FOR DOOR CHAUKHAT]
34Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
35Fixing of Door, windows/ventilators chaukhats in position.Door chaukhats
36Fixing of Door, windows/ventilators chaukhats in position.Window chaukhats
37Fixing of Door, windows/ventilators chaukhats in position.Ventilator chaukhats
38Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface & ceiling)Ground Floor
39Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)Ground Floor
40Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
41Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
42Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 10mm .
43Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete(a) 250 mm x 10mm
44Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
45Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
46Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.
47Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
48Construction of drain alongwith apron.
49Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
50Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).
51Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
52Providingandfixing 27.5 cm long wire spring grade 2 for rolling shutters.
53Providing and fixing ball bearing for rollong shutters.
54Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white plastic seat and lid
55Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
56Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Semi rigid pipe32mm dia
57Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
58Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore
59Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms.
60Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.110mm diameter
61Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
62Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm
63Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
64Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)Exposed on wall25mm dia nominal bore
65Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.25mm dia nominal bore.
66Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.internal work -Exposed on wall20mm dia nominal outer dia pipes
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.15mm dia nominal outer dia pipes
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes
69Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.15mm nominal bore
70Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore
71Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 893115mm nominal bore
72Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore
73Providing and fixing gun metal gate valve with wheel of approved quality.20 mm dia nominal bore
74Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore
75Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
76Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.
77Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter
78Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.150mm diameterS.W. Pipe
79Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75For Sewer Line
80Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard designWith 20x20 mm square bar
81Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.75 mm O.D.
82Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.110 mm O.D.
83Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.
84Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735.Size 75 mm
85Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735.Size 110 mm
86Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.Size 75x75x75 mm
87Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.Size 110x110x110 mm
88Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality).From 0.00 mt to 1.50 mt
89Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality)1.50mt to 3.0 mt
90Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality)3.0 mt to 4.50 mt
91Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.
92R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200.
93M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
94P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
95Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
9615 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand
97Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729
98Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)
99Providing and fixing C.I. tee at the inlet and outlet of septic tank.
100Providing & fixing of 75mm dia cast iron terminal guard.
101Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter
102Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.L.D. -2.5- Circular shape 450mm internal diameter
103Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
104ELECTRICALWiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash
105Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitwith modular typeswitch, G.P. Box & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.
106Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitwith modular typeswitch & socket etc, complete in all respect including matching colour wash.
107Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect.
108Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect.
109Supply and wiring of submain with two number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 20 mm dia. heavy duty (2 mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
110Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. CAT-AAA
111Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.Cat. AAA
112Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. CAT-AAA
113Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep
114Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class \"\"B\"\" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects.
115Supply and fixing of factory wired integral LED flood light luminaires having die cast aluminium housing built with driver set suitable for 100 to 120 watt confirming to IP 65 protection complete in all respect.Cat. AAA
116Supplyand burying safe earthing Electorde T-19 (HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25,terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12swg withHotDipGavanized up to 100 mirconfilled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitchboard , cost of 25 x 3 G.I. strip will be extra) Make:As approved in U.P.P.W.D. & C.P.R.I. Certified
117Supplying & Laying of 25mmx3mm G.I. Strip from earth electrode in ground as required complete in all respects.
118Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve6 - 32 amps.Cat. A
119Supply and fixing of 63 Amp. 4 Pole MCB (10KA)CAT A
120Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge.
121Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects.
122Supply and fixing of single pole MCB blanking plate
123Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work.
124Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
125Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
126Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work.
127Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
128Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 4 core
129Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
130Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes.
131Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required.80 mm Dia
132Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.-Make: Havells-STANDARD -Refresh Air-SPS300mm sweep.
133FIRESupply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
134Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
135BORINGBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level, All types of soil 300 mm dia
136Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
137Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
138SProviding and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete
139Supply of 2 HP submersible pump crompton varuna/KSB/CRI or equivalent make.
140Supply ofsingle phase strater for pump
141Supply and fixing of flat cable for pump 2.50 sqm 3 core copper cable
1424\" dia m.s.clamp made with 32*5 mm flat irion with nut and bolt
143100 mm dia PVC end Cap
144Nylon cloth for stainer including plastic rope cuttingholes in pvc pipe etc complete.
145P/Lowering of G.I. pipe 50 mm dia for submersible pump
146Devloping of bore well
147Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix Inside size 90x80cms and 45cms deep.

AI Tender Summary

OUR REF NO 36365064
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-03-2023
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Construction Of Child Development Planning Office Block At Danpur District Bulandshahr
Basic Detail
Tender No 92/PCL/PM/Noida/2022-23 Dt 20.02.2023
Bidding Type Tender
Location
City danpur
State Uttar Pradesh
Key Dates
Publish Date 20 Feb 2023
Submission Date 02 Mar 2023
Open Date 02 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 5900
EMD 51000
Exemption Not Available
Document List
c7641050-b37a-49a0-8acd-7647e1c63366.html
BOQ_1284014.xls
TenderDAN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 20, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 02, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 02, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c7641050-b37a-49a0-8acd-7647e1c63366.html

xls

BOQ_1284014.xls

pdf

TenderDAN.pdf

pdf

Tendernotice_1.pdf

Disclaimer