| 1 | a) Repairing/Servicing of HT/LT Electrical Panel Sub-Station EquipmentServicing of 1600/800 Amp rating, 415/500 Volts, withdrawable type, 3 phase, 4 wire, 50 Hz, AC supply, Air Circuit Breaker complete with removal from the panel board, opening/dismantling the required for servicing, checking and repairing of fixed and moving contacts, ecarbonization, insulation testing, testing and repairing of of trip circuit electrically and mechanically, indicator wiring, oiling, greasing, refixing, testing as required. |
| 2 | Checking control wiring of LT Air Circuit Breaker with Electric interlocking Manual on/off Testing and Commissioning etc as required. (Materials extra) |
| 3 | Supply of following materials for Air Circuit breaker automation Panela) Voltage Monitering relay, Model RS 232, supply voltage 415 Volt AC, 50 Hz. (Make : L&T / Schnieder / Siemens / C&S) |
| 4 | b) Supply of Under voltage release with control card for ACB Asrequired make L&T , Umega model. (Make : L&T / Schnieder / Siemens / C&S) |
| 5 | c) Supply of Shunt release 240VAC for ACB as required (Make : L&T / Schnieder / Siemens / C&S) |
| 6 | d) Supply of Trip/Closing Switch 25Amp. For Main, DG Incomer and Bus coupler (Make : L&T / Schnieder / Siemens / C&S) |
| 7 | e) Door lock for doors (Make : L&T / Schnieder / Siemens / C&S) |
| 8 | f) Indication Light LED type 240 volt AC (Make : L&T / Schnieder / Siemens / C&S) |
| 9 | g) Push botton with elements 1 NO+1NC (Make : L&T / Schnieder / Siemens / C&S) |
| 10 | h) Supply of UPS 2 KVA with battery (UPS Make : Luminious / Microtek / Su Kam and Battery Make : Exide / Amaron / Panasonic) |
| 11 | i) Power Pack Unit 24 V DC with 2 Nose 7 AH Battery (Make : L&T / Schnieder / Siemens / C&S) |
| 12 | j) APFC relay 12 stage, 240 Volt AC, 50 HZ(Make : L&T / Schnieder / Siemens / C&S) |
| 13 | Complete checking, control wiring of AMF Panel controler / PLC system with Electric interlocking Auto/Manual on/off Testing and Commissioning etc as required. |
| 14 | Repairing and servicing of HT 11 KV, 1000 KVA drytype transformer, removing dust, mastur of transformer lims, connection, tightning of incomming, outgoing connection i/c isolating transformer reconnecting etc. as required at site. |
| 15 | Servicing of Draw out type 11 KV, 630 amp, 3phase VCB from the HT, panel complete, cleaning & testing of wiring system, replacement of minor spare parts such as spring, nuts bolt & washer, setting right the mechanism and reassembling, testing and commissioning etc as reqd. |
| 16 | Servicing of Draw out type 11 KV, P. T. 3phase in the HT, panel complete, cleaning & testing of wiring system, replacement of minor spare parts such as spring, nuts bolt & washer and reassembling, testing and commissioning etc as reqd. |
| 17 | Calibration of over load & each fault relay, cleaning. Checking of wiring system calibration with secondary injection test kit, setting of tripping according to the load complete with testing and commissioning as reqd. |
| 18 | Repairing and servicing of thyrester type APFC Panel 350 KVAR, 415 Volt , 50 Hz, complete cleaning, checking control wiring & tightning all not bolts, replacement of minor space parts such as nuts bolts & washer, and reassembling ,testing and commissioning etc. as reqd. (Materials extra as required after testing & checking) |
| 19 | b) Fire Fighting SystemProviding laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.a) 150 mm dia. |
| 20 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : a) 80 mm dia. |
| 21 | b)100 mm dia |
| 22 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as requireda) 80 mm dia |
| 23 | b) 100 mm dia |
| 24 | c) 150 mm dia |
| 25 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :a) a) 150mm dia |
| 26 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. a) 200mm dia |
| 27 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : a) Stainless Steel (Grade 304) |
| 28 | Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required. |
| 29 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. a) 30 m |
| 30 | Providing & fixing of pressure switchin M.S. pipe line including connection etc. as required. |
| 31 | Painting of existing fire fighting MS pipe & hose box with approved colour & manufacture syntheic enamel paint with two or more coats and one coat of zinc chromate primer i/c scrapping the old paint complete as reqd as site |
| 32 | Supplying and fixing of Hose box (Double Door) (900mm x 600mm x 500mm) 16 gauge suitable for 2 no. 15mtr. Hose and 1 no short branch pipe. Complete in all respect etc as required. |
| 33 | Hose box (Double Door) (750mm x 600mm x 250mm) 16 gauge suitable for 2 no. 15mtr. Hose and 1 no short branch pipe. Complete in all respect Betc as required. |
| 34 | Providing & fixing of pressure guage in M.S. pipe line including connection etc. as required. |
| 35 | c) Replacement of Non-Functional Electrical FittingsSupplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 A switch |
| 36 | b) 15/16 A switch |
| 37 | c) 3 pin 5/6 A socket outlet |
| 38 | d) 6 pin 15/16 A socket outlet |
| 39 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required a) 3 module |
| 40 | b) 6 module |
| 41 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. Mm |
| 42 | b) 3 x 2.5 sq. mm |
| 43 | c) 3 x 4 sq. mm |
| 44 | d) 3 x 6 sq. mm |
| 45 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 46 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 47 | b) Single pole and neutral |
| 48 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A |
| 49 | Providing and fixing following rating and breaking capacity and pole TP/TPN/SPN MCB switchgears in the above TPDB i/c fitting strips for MCB ,making connections, etc. as required.a) 63 A, 10 KA , TP MCB (C-Curve) (For Vertical TPDB) |
| 50 | Supplying, Installation, testing and commissioning of prewired, 20 to 22 Watt aluminium body ,heat sink driver 1200 mm long LED Batten fitting wall mounted luminaire having the following specifications :i) Total System power - 2000 Lumensii) ColorTemprature - 5700 K to 6500 Kiii) Power Factor - not less than 0.95iv) CRI - not less than 80,v) System Lumen Efficency - Not less than 100 LM/W, complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd. |
| 51 | Supplying, Installation, testing and commissioning of Minimum 70-72 watt energy efficient LED Street Light luminaire made out of extruded aluminium pressure die cast housing, pure polishter powder coated dark grey housing, high efficiency, long life LED, IP 66 Protection i/c driver cover design to suit top maintenance with minimum lumens output noless than 100 lumens per watt suitable for cool day white light having minimum CCT 5700K to 6500K, power factor not less than >0.90, CRI > 70%, complete with all accessories etc. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing i/c dismantling of existing old fittings etc. as reqd. |
| 52 | Supplying, Installation, testing and commissioning of recess/surface mounted type Luminaries, glare free opal diffuser LED Panel of Nominal size 595 x 595 mm suitable for Armstrong / POP / GB ceiling with made out of CRC / MS Powder coated housing. Having the following specifications :i) Total System power - Not less than 3400 Lumensii) ColorTemprature - 5700 K to 6500 K,iii) Power Factor - > 0.95iv) CRI - > 80,v) System Lumen Efficency - Not less than 100 LM/W, including connections, testing etc complete as required. |
| 53 | SITC of Surface mounted 12 watt to 15 watt LED downlighter luminaire made out of extruded aluminium/CRC Sheet body with minimum lumens output not less than 100 lumens per watt suitable for cool day white light having minimum CCT 5700K to 6500K, power factor not less than >0.90, CRI> 70%, complete with all accessories etc. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable & earthing including dismantling of existing old fittings if any complete etc as required. |
| 54 | Supplying & Fixing of AC Three Phase Static Energy Meter with LCD DISPLAY of BLSM-E346 type of current rating 10-60A with ISI mark 13779 |
| 55 | Credit for following old/dismantle material received from day maintenance in the existing electrical installation etc. as reqd i/c dismantling & removal from site .(Labour for dismantling is already include in above items) (Dismantle Material receipt statement will be maintained by agency in Task Register).a) Assorted Tube fitting /Downlighter/Bulk head fittings |
| 56 | b) Assorted Flood Light/Street Light Fitting |
| 57 | c) Assorted 2X2 Light Fitting Panel |
| 58 | d) Assorted Pipe of 80/100/150 mm dia. |
| 59 | e) Assorted Hose Box ( Double Door) |
| 60 | f) Assorted Pressure Gauge & Pressure Gauge |
| 61 | g) Assorted Stainless Steel Y-Strainer 200 mm |