Tender For Providing And Fixing Submerged Centrifugal Pump For Dewatering At Barrage Garden Chambal River Front Kota, kota-Rajasthan

Urban Improvement Trust-UIT has published Tender For Providing And Fixing Submerged Centrifugal Pump For Dewatering At Barrage Garden Chambal River Front Kota. Submission Date for this Tender is 27-02-2023. Pump Supply Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36342566
Tender For Providing And Fixing Submerged Centrifugal Pump For Dewatering At Barrage Garden Chambal River Front Kota
Open Tender
Indian
Rajasthan
kota
27-02-2023

Tender Details

Providing And Fixing Submerged Centrifugal Pump For Dewatering At Barrage Garden Chambal River Front Kota Water Works

Key Value

Document Fees
INR 6000 /-
EMD
INR 398000.0 /-
Tender Value
INR 1.99 Crore /-

BOQ Items

Name of Work:Providing and fixing Submerged Centrifugal Pump for dewatering at barrage garden chambal river front kota
Sl. No. Item Description
1Providing, installation, testing and commissioningof Submerged Centrifugal Pumpsetswith motor4polesynchronisedspeedof1500rpm(water immersed, dry air filled, class "F" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, alongwith suitablefoundation/installationdeviceandwith 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete inallrespectasperspecification, scopeofworkand directionofEngineerinChargeoffollowingpowerrating,suitablefor prescribed duty conditions mentioned in TD.Make Aqua,Kirlosker,Mather&Platt
222 KW
345 KW
4P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
510.0 Sq.mm 3 core flat / Round
616.0 Sq.mm 3 core flat / Round
7Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approvedmakeof followingclass & diacompleteconfirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) /Fusion Bonded Epoxy (Non-Toxic &suitablefordrinkingwater)coatedwithminimumthicknessof250micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR"O "ring seal, Nut-Bolt confirmingto IS:1363and IS: 1367 (Galvanisedsteel) Insertionrubberof black EPDM6mm thick. Suitablesupportstructureas perdirectionsof EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
8Class PN 1.6, Manually Operated with Gear
9300 mm dia
10350 mm dia
11Providing, lowering, aligning, fixing in position and Jointing in pipe line, Cl Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressurerating & diacomplete, confirmingto IS: 14845-2000(amendedup to date) and of following specifications:Body , Cover and Cow) - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR,Ends flanged accordingto IS 6418,Fastners - CS, Epoxypaintinside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioningas per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
12Class PN 1.6
1350 mm
1480 mm
15Providing,lowering,aligning, fixingin positionin pipelineat worksite, DI D/F Resilientseated(softseated)SluiceValves(GateValves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2- 1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubberlinedwithEPDM(foodgradequality)andsealsofNBRFacetoface dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindleof SS (AISI316orequivalent)Electrostaticepoxypowder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thicknessof250micronsinsideandoutside,DrilledasperIS1538.Nut-Bolt confirming to IS:1363and IS: 1367(Galvanisedsteel) Insertionrubberof black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioningalong with pipe line as per Technical Specifications and as per direction of Engineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
16Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
17300 mm dia
18350 mm dia
19Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing typeNon ReturnValves(NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensionsas per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy(Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food gradequality) ,Shaft of HTB1/ SS- AISI- 410 ,HingeMalleablecast iron / SS AISI 316/410 ,Bonnet Gasket EPDM,Bush-Leaded tinBronze/PTET,Gasket EPDM/NBR ,Nut-BoltasperIS:1363andIS:1367(galvanisedsteel),Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along withpipelineasperTechnicalSpecification& asperdirectionofEngineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
20Class PN 1.0
21300 mm dia
22350 mm dia
23Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valvesstraightandpocketlessbodypassageofapprovedmakeof following Pressure rating& dia complete,confirmingto IS:14846(amendedup to date) and of followingspecifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,Faceto facedimensionsas perIS 14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirmingto IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
24Manually Operated CI Sluice valve of Class PN-1.0
25300 mm HW
26350 mm HW
27Providing,lowering,laying,aligning,fixinginpositionandjointingCIdismantling joint(SuitableforSluicevalvesetc.)asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioningTechnicalSpecifications and as per directionof Engineer.Class PN 1.0
28300 mm dia
29350 mm dia
30Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MSPipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latestrevision/ amendments, for following thicknessandinsidediameter,including alltaxes(Centralandlocal),transportationandfreightcharges, inspectioncharges,loading/unloadingcharges, includingcostof labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulictesting, disinfection,commissioningetc. completeasper technicalspecificationsand directionofEngineer-in-charge; (excluding earthwork, internal lining and outer coating). Note: Providingand fixingof allrequisitespecialsasperdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
31Dia of Pipe: 300.00 mm (I.D)
32Thickness of Pipe
336.0 mm
34Dia of Pipe: 350.00 mm (I.D)
35Thickness of Pipe
366.0 mm
37Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depthsin trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwith pipelineaspertechnicalspecificationsanddirection of Engineer- in-charge.
38MS pipespecialsup to600mmdia (withminimum5 mm thickness sheet)
39P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT"s, provision for potential free contacts making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
40Star - Delta Starter with following Motor rating
41Motor rating 22.0 KW
42Motor rating 45.0 KW
43SITC of Bulk Flow Meter with removable mechanism class "B” confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecifications complete: Media: Water(Clear), Temp. 50deg., Pr. rating:PN16, Protectiontype: IP- 68,BodyMaterial: IS-210Gr. FG-200, AccuracyClass :Class B (+2 % @ Nominal flow rate),Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk FlowMeter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
44BFM 300 mm
45BFM400 mm
46P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
47110 mm
48200 mm Dia.
49SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
50(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
51(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
52[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )
53(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
54(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
55(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )
56(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
57(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
58Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
59Electrolytic grade Aluminium bus bar 6010 grade
60Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
616 A to 32 A rating single pole
62SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
634 pole MCCB With Thermal Magnetic release
64200 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
65250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
66Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
67Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
6825mm x 3mm G.I. ( Hot Dipped) Strip
69Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
70185.0 Sq. mm
713.5 core
72Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
733.5 x 185.0 sq.mm
74Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
75Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
76Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
771:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
78Providingexperienced and Highly skilled/skilled/ semi-skilled/Un Skilledlabour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month)
79skilled Labour
80Un skilled labour
81SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I
82A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required .
83B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled
84C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.
85D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :
86E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA.
87F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.
88G) Servicing Contract of DG Set from OEM"s Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department.
89H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration.
90I) DG set will be offered for Inspection and Testing at Manufacturer"s Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
91250 KVA at 0.8 pf 415V 50Hz 3-?
92SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
93250 KVA
94SITC of Inline Exhaust fan for Toilet ventilation.Cabinet type 1000 CFM inline exhaust fan inside acccoustic shall be properly fixed/supported with suitable M.S. hanger/Chennel with fastners complete in all respect.
95Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive)& fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
960.60 mm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy