Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CONSTRUCTION OF DEVDARSHANI STHAL,BADRINATH |
| 2 | Civil work (Building)Earth Work |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 SqM on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 4 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 SqM on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within alead of 50 m.out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Ordinary rock |
| 5 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 6 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary and Hard Rock rock |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 8 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 9 | CONCRETE WORK |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 11 | REINFORCED CEMENT CONCRETE |
| 12 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kg/CuM. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level |
| 13 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kg/CuM. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 20 | MASONRY WORK |
| 21 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 23 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 24 | Stone work (machine cut edges) 50mm thick fine dressed stone for extrnal wall for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Local Hammer dressed stone of size (300x150x50)mm |
| 25 | 70 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Local Hammer dressed stone of size (450x350x70)mm |
| 26 | STEEL WORK |
| 27 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DOM Structure) |
| 28 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Railing (DOM CIVIL) & Hot finished welded type tubes (DOM Structure) |
| 29 | FLOORING |
| 30 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600x600 mm(Anti Skiid) |
| 31 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 32 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 33 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 SqM |
| 34 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per SqM, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | WOOD AND PVC WORK |
| 37 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 38 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters |
| 39 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 40 | Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm) |
| 41 | Providing and fixing bright finished brass handles with screws etc. complete: 125 mm |
| 42 | Providing and fixing bright finished brass handles with screws etc. complete: 100 mm |
| 43 | Providing and fixing bright finished brass handles with screws etc. complete: 75 mm |
| 44 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 45 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm |
| 46 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 47 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type) |
| 48 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 75x65x4 mm (heavy type) |
| 49 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 50 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 Kg to 80 Kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 51 | Providing, laying and fixing of Deodar Wood as in built runner having size of 100mmX50 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc.. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification. |
| 52 | Providing and fixing Deodar Woodceiling in 25 mm thick 150 mm wide deodar wood plank. |
| 53 | Providing and fixing Deodar WoodJhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank. |
| 54 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Details of cost for Decorative Brackets 1.35x0.12x.12m Second class teak wood |
| 55 | FINISHING |
| 56 | 12 mm cement plaster coarse sand of mix : 1:6 (1 cement: 6 fine sand) |
| 57 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 59 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 60 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 61 | Providing and laying Water Proofing Treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 Kg/SqM mixed with water proofing cement compound @ 0.253 Kg/SqM. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 Kg/SqM mixed with water proofing cement compound @ 0.670 Kg/SqM and coarse sand @ 1.289 Kg/SqM. This will be allowed to air cure for 4 hours followed bywater curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paidfor separately. (For the purpose of measurement the entire treated surface will be measured.) |
| 62 | ROOFING |
| 63 | Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles havingmultilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H.The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Eq. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job.Note: (i) Overlapping has to be provided between two laminated Asphalt Shingles sheets as per the norms. The overlap quantity will not be considered for the measurement/ payment |
| 64 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 65 | ROADWORKS |
| 66 | Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer |
| 67 | EXTERNAL SITE DEVELOPMENT |
| 68 | Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.) |
| 69 | Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/selected soil having C.B.R.>5 (unless specified otherwise in the contract)obtained from borrow pits with all lifts and leads,transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) |
| 70 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction |
| 71 | SUB-BASES, BASES ( NON- BITUMINOUS) AND SHOULDERS |
| 72 | Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material |
| 73 | WBM Grading 2Providing, laying, spreading and compacting stone aggregates of specific sizes towater-boundd macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Mechanical Means |
| 74 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Mechanical Means |
| 75 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller,finishing and curing.) |
| 76 | TRAFFIC SIGNS, MARKINGS & OTHER ROAD APPURTENANCES |
| 77 | Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick,foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Batching and Mixing Plant |
| 78 | Interlocking Concrete Block Pavement Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504. |
| 79 | CONCRETE WORKS |
| 80 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M15 Height upto 5m |
| 81 | REINFORCED CEMENT CONCRETE |
| 82 | RCC Grade M25 Height upto 5m All works upto plinth level With Batching Plant, Transit Mixer and Concrete Pump |
| 83 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications |
| 84 | MASONARY AND PLASTER WORKS |
| 85 | Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction |
| 86 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 87 | HORTICULTURE |
| 88 | Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately)) |
| 89 | Grassing with \" Doobs\" Grass (Grassing with \"Doobs\" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) In rows 7.5 cm apart in either direction |
| 90 | Making Lawns including Ploughing and Dragging with \"Swagha\" Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm) |
| 91 | GATEWAY Devdarshani Sthal |
| 92 | CIVIL WORK |
| 93 | Earth Work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of Soil. |
| 94 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary Rock |
| 95 | Extra for every additional Lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 96 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock |
| 97 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 98 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) PCC: M20 |
| 99 | RENFORCED CEMENT CONCRETE WORK |
| 100 | Providing and laying in position machine batched and machine mixed design mixM-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level |
| 101 | Providing and laying in position machine batched and machine mixed design mixM-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level |
| 102 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 103 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 104 | CENTRING AND SHUTTRING |
| 105 | Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete |
| 106 | Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 107 | Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 108 | MASONRY & PLASTER WORK |
| 109 | Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 110 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 111 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Local Hammer dressed stone of size (300x150x50)mm |
| 112 | 70 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Local Hammer dressed stone of size (450x350x70)mm |
| 113 | 12 mm Cement Plaster of mix : 1: 6 (1 cement: 6 fine sand) |
| 114 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement |
| 115 | FLOORING |
| 116 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 117 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 118 | DOOR & WINDOW WORK |
| 119 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). ( Teak wood ) |
| 120 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately) Second class teak wood( 35 mm thick shutters ) |
| 121 | Extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive,including cleaning etc. complete. |
| 122 | Door Fittings (Aluminium) |
| 123 | Providing and fixing bright finished brass handles with screws etc. complete: ( 125 mm ) |
| 124 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :( 200 x 10 mm) |
| 125 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete |
| 126 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100 x 85 x 5.5 mm (heavy type) |
| 127 | Same as above but75x63x4 mm |
| 128 | Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 200 mm weighing not less than 240 gms |
| 129 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 130 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 131 | M.S. & STEEL WORK |
| 132 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 133 | Structural steel work riveted, bolted or welded in HOT FINISH SEAMLESS TYPE ( SQUARE OR RECTANGULAR HOLLOW TUBE TYPE ) built up sections , wooden finish, for all kinds of shape & size of column work, including cutting, hoisting, fixing in position and applying a primer coat of approved zinc primer and 2 coats of oil paints of Asian, ICI or equivalent make as approved by architect in due respect to complete all.Truss Work |
| 134 | Wood Work |
| 135 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Deodar WoodJhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank. |
| 136 | \"Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Providing, laying and fixing of Deodar Wood as in built runner having size of 100 mm X 100 mm thru out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc.. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job.manufacturer specification. {* We proposed Teak wood (as per DAR 9.1.1.) instead of Sal Wood } |
| 137 | Providing and fixing Deodar Woodceiling in 25 mm thick 150 mm wide deodar wood plank. |
| 138 | FININSHING & PAINTING WORK |
| 139 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 140 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 141 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 142 | Roof |
| 143 | SHINGLE ROOFING SYSTEM Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles havingmultilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H.The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Eq. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job.Note: (i) Overlapping has to be provided between two laminated Asphalt Shingles sheets as per thenorms. The overlap quantity will not be considered for the measurement/ paymentDetail of cost for roofing 100 sq.ft. Specified Roofing sheet material having 1.0 mm thick pre coated GI Sheet ofas per manufacturere specification. Notes:- (1) It allows making connections attractive and weatherproof\". (2) It allows for weatherproof roof penetrations. (3) It allows to complete entire roofing system at level of satisfaction in due respect. (4) It allows for Deodar WoodJhalar (Manually Hand Carved) in 2 inch thick 300mm wide deodar wood plank. |
| 144 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 145 | SMART ART WORK |
| 146 | Smart ArtWorks as per requirement and suggestions of Temple Committee |
| 147 | Sanitary Fixutures and Fittings |
| 148 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap,flush valve, fittings, nuts, bolts and gasket etc complete including flush pipe, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Refer following product wise details;Orisapan : Cera, Model No: CABLE S3020105 (580X400MM), Snow White Trap: Cera, Cat No: Cat. No. S9030101, Snow White Metropole flush valve Dual flow : Jaquar, Model No: FLV-1085NG |
| 149 | Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per specifications;glazed vitreous / ColouredEuropean Water Closet with metropole flush valve, with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC.,1 No.CPVC connection with brass union nuts CP coated and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; including painting of fittings and brackets, cutting and making good the walls wherever require: etc. complete. The rates including cost and conveyence of all materials, labour, machinery etc.EWC-P with Soft close Seat cover : Jaquar, Model No:CNS-WHT-959SMetropole flush valve Dual flow : Jaquar, Model No: FLV-1085NG |
| 150 | Providing and fixing White glazed vitreous Wash Basin Oval Under-Counter, size 560 x 430 x 195 mm dia.,with supporting M.S. or C.I. Brackets, necessary pipe connection up to the outside face of the wall,having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with 80 mm height Chrome plated, Bottle trap Chrome plated Basin Mixer necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.OVAL UNDER COUNTERBASIN: Jaquar Continental, Model No: FLS-WHT-5701 WASTE COUPLING : Jaquar , Model No: ALD-CHR-705 BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190 Basin Mixer: Jaquar , Model No: FLR-5001B |
| 151 | Providing and fixing stainless steel single bowl sink with side plate with drain board, R.S. or C.I. Painted brackets painted, 40mm dia. C.P. waste coupling, bottle trap Jaquar Continental, , C.P. brass chain and rubber plug, strainer with necessary C.P. brass unions complete including painting the fittings and cutting and making good the walls wherever required etc. complete the job. Sink: NIRALI -Olympia Small -Satin- 950 MM X 510 MM WASTE COUPLING : Jaquar ,Model No: ALD-705L130 BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190 |
| 152 | Providing & fixing Janitor Sink, R.S. or C.I. Painted brackets painted, 40mm dia. C.P. waste, C.P. brass chain and rubber plug, strainer with necessary C.P. brass unions complete including painting the fittings and cutting and making good the walls wherever required, etc. complete the job. |
| 153 | Providing and fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required.ANGLE VALVE : Jaquar, Model No. FLR-5053N BRAIDED HOSE Copper Pipe : Jaquar, Model no. ALD-CHR-805B |
| 154 | Providing and fixing in position 15 mm C.P. brass long body bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : Jaquar Continental, Model No: CON-107KN |
| 155 | Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1Rmt Long pvc Tube and Wall Hook accessories of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.HAND SHOWER : Jaquar , Model No: ALD-573 |
| 156 | Providing and fixingSink mixer of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.Single level Sink Mixer: Jaquar Fusion, Model No. FUS-29173B |
| 157 | Providing and fixing of 3 in 1 wall mixer system with provision for overhead shower complete with bend pipe including necessary fittings with wall flange etc complete in all respects including cutting and making good the walls etc. SHOWER HEAD: Jaquar MODEL NO. OHS-CHR-1757 SHOWER ARM Jaquar MODEL NO. SHA-CHR-487 WALL MIXER Jaquar MODEL NO. FUS-CHR-29273UPR |
| 158 | Providing and fixing in position best Indian make toilet recessed type paper holder complete in all respects including cutting and making good the walls etc. TOILET PAPER HOLDER : Jaquar , Model No: AHS-1553 |
| 159 | Providing & fixing C.P. brass towel ring fixed to rawl plug with C.P. brass screws.TOWEL RING : Jaquar Continental, Model No.: ACN-1121BN |
| 160 | Providing & fixing towel rail of approved make including, providing & fixing C.P. brass screws, making holesin walls & making good.TOWELRAIL: Jaquar Continental, Model No. ACN-1111SM |
| 161 | Fixing stainless steel recessed type soap dish of approved make. Including providing&fixing screws, washers, cutting & making good the walls. SOAP DISH : Jaquar, Model No: AKP-35731P |
| 162 | Providing and fixing C.P. brass liquid soap container of best quality.LIQUID SOAP CONTAINER: Jaquar , Model No: SDR-WHT-DJ0010F |
| 163 | Providing and fixing in position best Indian make C.P. brass twin way QUOTE and hat hooks fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the walls etc.DOUBLE QUOTE HOOKS: Jaquar, Model No: -ACN-1161N |
| 164 | Providing and fixing of electrical Storage type water Geyser inclusing all required accessories cutting, chassing and good the same. 25 Litre Storage, Make:Jaquar Elena vertical |
| 165 | Providing and fixing of electrical Instant type water Geyser inclusing all required accessories cutting, chassing and good the same. 6 Litre Insta, Make:Jaquar Elena Insta |
| 166 | Providing and fixing of electrical Instant type water Geyser inclusing all required accessories cutting, chassing and good the same.3 Litre Insta, Make:Jaquar Insta |
| 167 | Providing and fixing of electrical Instant type water Geyser inclusing all required accessories cutting, chassing and good the same.10 Litre Insta, Make:Jaquar Elena Insta |
| 168 | Electrical hand dryer, fully automatic type , cover shall be fabricated in extra heavy duty18 gauge type 304 SS with exposed surfaces stainless steel finished, the unit shall deliver not less than 71 l/secof hot air and electrical rating shall be 240 V / 1 phase / 50 cycles HAND DRYER : Jaquar , Model No: HDR-SSF-AK2803D |
| 169 | Providing and fixing of Automatic Fragrance Dispenser fixed to wooden cleats with C.P. brass screws complete.Fragrance Dispenser : EURONICS, Model No. : EA-03 |
| 170 | Providing and fixing white vitreous china flat back urinal of size 385x325x635mmas per IS-2556 (Part-2) with C.I. hangers and 15mm dia. C.P. spreader,Waste coupling,32mm dia CP bottle trap and pipe to wall with C.P. flange with Pressmatic Urinal Flush valve with wall Flange etc. complete including cutting and making good the walls wherever required. FLAT BACK LARGE URINAL : Jaquar , Model No: URS-WHT-13253OWASTE COUPLING : Jaquar ,Model No: ALD-705L130BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190Pressmatic Urinal Flush : Jaquar, Model No: PRS-073 |
| 171 | Providing and fixing of urinal partition 900mm height and 450mm width , Frosted Safety Glass 8mm thick, chrome colour, including providing & fixing concealed CI bracket, cutting and making good the same. Urinal partition : Jaquar JSE-CHR-810UC450X |
| 172 | Providing and fixing in position 15 mm C.P. brass bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : Jaquar Fusion , Model No. FUS-29037 |
| 173 | Internal & ExternalDrainage Work |
| 174 | Providing, Fixing, testing & commissioning of 50 mm Outer dia HDPE soil & waste Pipe as per EN 12056, DIN 4102-B2 complete including all fittings, specials, jointing & hydraulic testing the joints & pipes as mentioned in the specification etc. and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels as per direction of engineer in charge. |
| 175 | Providing, Fixing, testing & commissioning of 75 mm Outer dia HDPE soil & waste Pipe as per EN 12056, DIN 4102-B2 complete including all fittings, specials, jointing & hydraulic testing the joints & pipes as mentioned in the specification etc. and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels as per direction of engineer in charge. |
| 176 | Providing, Fixing, testing & commissioning of 110 mm Outer dia HDPE soil & waste Pipe as per EN 12056, DIN 4102-B2 complete including all fittings, specials, jointing & hydraulic testing the joints & pipes as mentioned in the specification etc. and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels as per direction of engineer in charge. |
| 177 | Providing & fixing HDPE P Trap of 110mm dia diameter With Height riser/necessary distance piece for wash basin/sink/Urinal drain connection with and 150x150mm heavy duty openable grating, making necessary SLAB /WALL/Beam holes and cutting walls, etc complete. |
| 178 | Providing and fixing 100 mm sand cast Iron grating for P trap. |
| 179 | Providing and fixing of 110 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 180 | Providing and fixing of 160 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 181 | Providing and fixing of 200 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 182 | Providing and fixing of 250 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 183 | Providing and fixing of 355 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 184 | Providing and fixing of 450 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 185 | Providing and fixing of 500 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 186 | Providing and fixing of 710 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints,including trenching, refilling & testing of jointsetc. complete as per direction of Engineer-in-Charge. |
| 187 | Making connection toSewage water line / existing drain including bracking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing sewage/ storm/ water line in the existing structure either through masonry or CC and providing suitable \"Y\" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions tasting etc. complete. |
| 188 | Internal & External Water Supply Work |
| 189 | Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chases and making good the wall etc. |
| 190 | Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. |
| 191 | Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. |
| 192 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. |
| 193 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. |
| 194 | Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. |
| 195 | Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 196 | Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 197 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 198 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 199 | Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 200 | Providing and fixing of 75 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 201 | Providing and fixing of 90 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls |
| 202 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 203 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 204 | Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 205 | Providing and fixing of 75 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 206 | Providing and fixing of 90 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 207 | Providing and fixing of 110 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 208 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 20 dia pipe |
| 209 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc.(Inside Toilet) for 25 dia pipe |
| 210 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 32 dia pipe |
| 211 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 40 dia pipe |
| 212 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 50 dia pipe |
| 213 | Providing and fixing 9mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 65 dia pipe |
| 214 | Supplying, laying/ fixing, testing and commissioning of following 50mm thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required. |
| 215 | Providing and fixing of 25mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 216 | Providing and fixing of 32mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 217 | Providing and fixing of 40mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 218 | Providing and fixing of 50mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 219 | Providing and fixing of 65mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 220 | Providing and fixing of 80mm diameter gun metal gate valve with C.I. wheel of approved quality. |
| 221 | Supplying, fixing, testing and commissioning of 40mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified. |
| 222 | Supplying, fixing, testing and commissioning of 50mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified. |
| 223 | Supplying, fixing, testing and commissioning of 65mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified. |
| 224 | Supplying, fixing, testing and commissioning of 80mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified. |
| 225 | Providing and fixing of 40mm diameter gun metal non- return valve (vertical) of approved quality. |
| 226 | Providing and fixing of 50mm diameter gun metal non- return valve (vertical) of approved quality. |
| 227 | Providing and fixing non-return valve of 65 mm dia with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. |
| 228 | Providing and fixing non-return valve of 80 mm dia with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. |
| 229 | Providing and fixing non-return valve of 100 mm dia with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. |
| 230 | Providing and fixing Y - strainer of 80 mm diameter Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation as specified. |
| 231 | Supply, Installation, Testing and Commissioning of 25 mm dia. air release valve.)(Make: Audco/ R.B./ Spirex) |
| 232 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50mm dia |
| 233 | Providing and fixing 50mm gun metal score valve of approved quality. |
| 234 | Supply, testing & commissioning of flange ends NB 80mm PN-1.6Expansion Bellow as per EJMA stanDSRds of overall length of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure ratings. MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 /IS 6392) & Limit Rods & Nuts: CS - IS 1367. |
| 235 | Providing and fixing 25mm dia float valve withpressure typePTMT float valve.(Make: Prayag) |
| 236 | Providing and fixing 32mm dia float valve withpressure typePTMT float valve.(Make: Prayag) |
| 237 | Providing and fixing 40mm dia float valve withpressure typePTMT float valve.(Make: Prayag) |
| 238 | Providing and fixing 50mm dia float valve withpressure typePTMT float valve.(Make: Prayag) |
| 239 | Providing andfixing mosquito proof stainless steel overflow gratingfor tanks.( Zoloto/ Audco/ R.B./ Spirex) |
| 240 | Supplying, fitting & fixing of 50mm dia Pressure Reducing Valve set of approved make & best quality having by-pass valve arrangement including of 3 nos isolation valve. |
| 241 | Supplying, fitting & fixing of 80mm dia Pressure Reducing Valve set of approved make & best quality having by-pass valve arrangement including of 3 nos isolation valve. |
| 242 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 243 | Supplying and fixing 50mm thick aluminium foil faced resin bonded fibre glass insulation (for polyethylene water storage tank) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications) |
| 244 | Supply, intallation, Testing and Commisioning of 20mm diameter Garden Hydrant with gun metal Ball Valve, Flexinble hose Connection Provision and all required accessories etc. |
| 245 | Supply installation, testing and commissioning of drinking water filtration system comparision of multigrade sand filter, activated carbon filter, Ultra-filtration & High penetration Ultraviolet. The scope shall include interconnection piping, valves, instruments & pump system, all other required accessories, pump Set is auto operation, including dry run protection,all valve controls, interconnecting piping of suction and discharge header, control panel IP 55, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, adequate NO NC contacts for integrating with Building Automation System(BMS), interlocking arrangement, level controller and other necessary cabeling works etc. complete the job. Capacity: 250LPH |
| 246 | Making connection toWater Supply line / existing tank including breaking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing water line in the existing structure either through masonry or CC and providing suitable \"Y\" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions tasting etc complete. |
| 247 | Pump & Equipment |
| 248 | HYDRO PNEUMATIC SYSTEM FOR Domestic Water Distribution Hydropneumatic SystemVariable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition)coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessorbased multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controllershall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job.Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 4.0 m3/hour , Head -40 mt,1 Set= 2 Nos. Pump (1 Working + 1 Standby - cascade operation) , Total Capacity of System: 12 m3/hour,Location- Pump Room, Suction head -Flooded positive suction |
| 249 | UGTPump Room Sump Drain Pump Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail. (Pumps suitable to handle solids upto 20 mm size withC.I. body, SS304 shaft, SS impeller ). Panel mounted pump controller with DOL starter,IP 55 enclosure, ON-OFF and Trip indicating lamps in each incomer and outgoing feeders. The controller shall support MODBUS-IP communication for its compatability to integrate with 3rd party BAS system. Necessasary contactors & relays shall be provided for BMS connectivity. It shall authorised Read/write command via BMS, interlocking arrangement, dry run protection, cascade operation, working/standby selection, with provision of remote on/off operation complete as require. The on/off operations for all pumps shall be available on central BMS system. Each incomer and outgoing feeder should be capacble for protection against overload, earthing, short circuit and phase reversal condition and shall be capable to communicate with BMS. Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete the job.SITC ofelctronic type High & Low water level controler with LED panel to operate pump ,level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running. Mounting Height (Low Level) : 100mm bottom of Sump Mounting Height (High Level) : 1000 mm from the bottom of Sump Set of accessories such as CPVC SCH 80 headers of suction and discharge for (working and Standby pump assembly), Gun Metal Ball Valve , Cast iron non return valves, pressure gauge of PN10 etc. etc. complete the job. Capacity per pump - 5.0 m3/hour , Head -15 mt,1 Set= 2 Nos. Pump (1 Working + 1 Standby - cascade operation) , Total Capacity of System: 10 m3/hour,Location-Pump Room |
| 250 | SEWAGE SUMP PUMPSupply, installation, testing & commissioning of Submersible Non Clog sewage pump with Cutter, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail.(Pumps suitable to handle solids upto 20 mm size withC.I. body, SS304 shaft, C.I./SS impeller ), 2 pole Motor & IE2 Efficiency . Panel mounted PLC based pump controller, IP 55 enclosure, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, adequate NO NC contacts for integrating with Building Automation System, interlocking arrangement, dry run protection, cascade operation, working / standby selection, with provision of remote on/off operation complete as require. The on/off operations for all pumps shall be available on central BMS system. Each incomer and Outgoing feeder should be capable for protection against Overload, earthing, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS. Scope shall also include supply, laying, termination of control and power cables of adequate size, and arrangement of cable tray from Pump to Control panel etc. to complete the job.SITC ofelctronic type High, Medium & Low water level controler with LED panel to operate pump (necessary contacts along with minium one PLC spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at high level and cut off at dry level with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running.Mounting Height (Low Level) : 100mm bottom of SumpMounting Height (Medium Level) : 400 mm from the bottom of SumpMounting Height (High Level) : 1000 mm from the bottom of SumpSet of accessories such as PPRdischarge headers for (working and stand by pump assembly) from sump bottom to disposal point, Cast Iron control valves, Cast Iron non-return valves,pressure gauge of PN10 etc. complete the job.Pumping system shall be as per GRIHA Norms.DRAIN PUMPS Capacity per pump - 5.0 m3/hour,Head -15 mt,Location - Sewage sump , 1 Set = 2 Nos. Pump (1 Working + 1 Stand by - cascade operation) Total Capacity of System: 10m3/hour. Suction head - flooded positive suction |
| 251 | Supply of 100 mm Full Bore Electromagnetic Flow Meter with factory calibrated, IP - 68, Battery operated, flanged connection, flow meter, indicator, transmitter and totaliser with all accessories viz. power and control cables upto starter panel, cabinets, hardwares etc. complete as per following specifications including fixing using flanged specials with bolts, nuts & packing with testing. Scope also including testing and commissioning. (I) Flow Sensor: Neoprene/Polurethene lining, DC Pulsed, SS 316 electrodes, CS / SS 316 flanges, fully welded / SS 304 sensor construction & housing. (II) Flow Transmitter / converter: Micropressor based/Modular design/HART type, 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totaliser display, one current (4-20 mA)/one scalable pulse / one status output, IP 67, Die cast alluminium with PU finish with glass window enclosure, 10 metres length sensor cable. |
| 252 | Fire External Hydrant |
| 253 | Providing and fixinghydrant stand posts ( yard hydrant) of 80 mm dia. With flanges and accessories and supply, fixing single headed 63 mm dia G.M. Hydrant Valve in the courtyard IS:5290Including 2 coats of approved enamel paint (red) over a coatof primer, complete with 2.1/2” ‘Morris’ pattern instantaneous couplings, including Signages etc. complete. |
| 254 | Providing & fixing 63mm diaRRL hose pipe as perIS 636 TYPE ALFAapproved of 15 mtr. x2 No.standard lengthof approved pattern and size including gun metal male and female Coupling duly bound withcopper wireetc. complete |
| 255 | Providing and fixing approved fire hose cabinetstand mount type for external size 600x 750x 250mm to house fire hydrant & hose, including all other related accessories fabricated from SS 316 of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as mentioned in drawing (or as approved by the Architect) to house 15 mtr.x2 No. hoses including Signages |
| 256 | Providing and fixing gunmetal branch pipe nozzle conforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required: |
| 257 | Supplying and fixing specially designed gunmetal orifice plates (minimum 8 mm plate thickness)on hydrant outlets of landing valves including distant pieces of suitable size for reducing delivery pressure to 3.5 kg/ sq.cm at hydrant valve ,as required by LFA complete with necessary accessories, etc. complete. |
| 258 | Supplying, installation testing and commissioning of80 mm dia nominal bore‘C’ class GI Pipe as per IS : 1239-1973 tested to 200 PSI complete with fitting & welding of pipes & fittings wherever required complete with flanges & painting , with all the engineered support as per detail technical specification. underground/overground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required byLFAauthorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over heads pipes and providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.complete as per ASTM standards/IS:10221 for corrosionprotection of pipes for the under ground installation. Note :The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. |
| 259 | Charges for Liasoning with Fire officer and getting all approvals and permissions & NOC \"s required for fire fighting at various stages & after completion of the project including All official payments. |
| 260 | WATER SUPPLY& SEWAGE WORKS |
| 261 | LAYING PIPES |
| 262 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposalof surplus excavated soil as directed, within a lead of 50 metres |
| 263 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. |
| 264 | PCC(1:3:6) at bottom of pipe (refer typical section drawing) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 265 | Thrust Block (Refer Typical section drawing) |
| 266 | PCC(1:3:6) at bottom of pipe (refer typical section drawing) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 267 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 268 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 269 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete,with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less standard design: than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (refer typical section drawing) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 270 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils |
| 271 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soils |
| 272 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
| 273 | Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete |
| 274 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 275 | Pump Room with Under Ground Tank (refer UGT drawing) |
| 276 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 277 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within alead of 50 m.out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Ordinary rock |
| 278 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m . |
| 279 | CONCRETE WORK |
| 280 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement: 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 281 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level |
| 282 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level |
| 283 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 284 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 285 | MASONRY WORK |
| 286 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 287 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 288 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 289 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 290 | 12 mm cement plaster coarse sand of mix : 1:6 (1 cement: 6 fine sand) |
| 291 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 292 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 293 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 294 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 295 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 296 | DEMOLISION WORKS |
| 297 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 298 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Up to 150 mm diameter |
| 299 | Electrical Work (DEVDARSHANI STHAL,BADRINATH) |
| 300 | LT PANELSupply, Installation testing & commissioning of medium Voltagesheet steel metal clad, compartmented cubicle Panel board. Detail specification shall be followed. Shifting of panels from site store to the suitable location. Assembling and wiring of component supplied separately. Earthing all components, frame etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job. Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. The rates for the distribution boards apart from the Breakers and instruments shall also include the following :This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type, 14 gauge CRCAsheet steel enclosed. Proper bonding to earth. Painting/letteringon Breakers and distribution boards,the locationthey serve,providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. If any TPN ACB’s / MCCB, itshall bewith adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity. Thebreakingcapacity of MCCB’s are mentionedpanelwise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. All motor feeders MCCBs shall be of motor duty. Distributionpanels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 4X for all Indoor panel. IP 65 and double door for all outdoor panel.AllMCCB’s shall be provided with operating mechanismfor door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic.All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.SPD as shown in SLD. Aprooved Makes-L&T/ABB/schnider/Legrand/SIEMENS |
| 301 | Supply, Installation,testingandcommissioning of IP 42 rated MAIN PANEL FOR DEV DARSHANI Having,Incomer: 125 Amp 25 KA FP MCCB (MOTORIZED),1 NO SPD1 NO MFMINDICATION LAMP- 6 NOS Out Going: 25 Amp DP 10KA MCB (01Nos),25 Amp FP 10KA MCB (05Nos),40 Amp FP 10KA MCB (03Nos) &63 Amp FP 10KA MCB (02Nos)ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 302 | Supply, Installation,testingandcommissioning of IP 42 rated EXT. LTG. & FACADE PANEL FOR DEV DARSHANI Having Incomer 40 Amp 10 KA FP MCB (01No) Out Going 40 Amp heavy duty contactor (02No)16 Amp FP 10KA MCB (9Nos) 16 Amp SP 10KA MCB (27Nos) 25 Amp FP 10KA MCB (2No)25 Amp DP 10KA MCB (2No)with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. |
| 303 | Supply, Installation,testingandcommissioning of IP 42 rated APFC PANEL FOR DEV DARSHANI Having Incomer: 63 Amp 16 KA FP MCCB (01 No)1 NO SPD1 NO MFMINDICATION LAMP- 6 NOS APFC RELAY PANEL WITH 7% DETUNED FILTER WITH DUEL SET POINTOut Going:25 Amp TP 10KA MCB (03Nos) - 10 KVAR &16 Amp TP 10KA MCB (03Nos) - 5 KVARCapacitor Bank (02Nos. 10KVAR) &Capacitor Bank (02Nos. 5KVAR)ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 304 | DISTRIBUTION BOARDSSupply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12way, Double door (IP43, IK09) |
| 305 | Supply, Installation, Testing and commissioning of Timer having inbuilt contactor of 16A switching capacity (3600W), delay range setting, equivalent to Schneider CCT15225 / ABB / LEGRAND. |
| 306 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09) |
| 307 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door(IP43, IK09) |
| 308 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door(IP43, IK09) |
| 309 | Supply, installation, testing and commissioning \"B\" series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 310 | Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A. Approved Makes-LEGRAND / SCHNIEDER/ SIEMENS / L&T / ABB |
| 311 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A |
| 312 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 313 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 314 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 40A |
| 315 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 63A |
| 316 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 25AApproved Makes-LEGRAND / SCHNIEDER/ SIEMENS / L&T / ABB |
| 317 | Supply Installation, testing and commissioning Of PPI Kit for 8 Way TPN PPI DD DB.Approved Makes-LEGRAND / SCHNIEDER/ SIEMENS / L&T / ABB |
| 318 | MV CABLESLaying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.Upto 35 sq. mm |
| 319 | Laying and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 320 | Supply, connection, testing and commissioning of heavy duty, medium voltage,XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS.The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified.The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge.The scope shall include:1) Supply of Cables.(With Non Returnable Drums)2) Delivery of the cables at site.3) Unloading at site store.4) Shifting of cable from site store to place of installation.5) Connection of cable with proper tagging as specified ni specifications.6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.8) Testingof insulation and continuity of cable and submission of reports to the client\"s representative.9) To prepare submission drawing and to take approval of consultant at each stage.10) To prepare & submit as-built drawing and handing over document to end user.11) Rate shall be inclusive of route markers at 15mtr intervals12) Each run of cable to be tested with 1KV meggar13) Proper cables tags of Aluminium shall be made and feeder shall be written.Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS |
| 321 | 3.5C x 35 Sq.mm. Aluminum XLPE armored cable |
| 322 | 4C x 16 Sq.mm. CU XLPE armored cable |
| 323 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 324 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 325 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 326 | 3C x 10 Sq.mm. CU XLPE armored cable |
| 327 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 328 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 329 | CABLE TERMINATIONSupply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland.Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI |
| 330 | 3.5C x 35 Sq.mm. Aluminum XLPE armored cable |
| 331 | 4C x 16 Sq.mm. CU XLPE armored cable |
| 332 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 333 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 334 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 335 | 3C x 10 Sq.mm. CU XLPE armored cable |
| 336 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 337 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 338 | INTERNAL WORKSPOINT WIRINGSupply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDBto respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points.Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approvedrigid FR PVC,conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmiumplatedmachine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. |
| 339 | Wire Size for Lighting circuitLighting circuit= 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board)From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E)Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E)Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly.Making of zari in wall using only electric cutter and finishing the surface as it was.earthing of fittingelectrical connection to the fixture from the out let point/ceiling rose.Wire breaded PVC flexible conduit from ceiling point to light fixture.Supply and fixing of supporting frame, hardware and n/c tools and tacklesetc ForExhaust fan |
| 340 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required- Group C |
| 341 | light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 342 | power plug point modular type accessories:Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess,including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 343 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 344 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 345 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 346 | Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required. |
| 347 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep. |
| 348 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 349 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 350 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.3 Module (100mmX75mm) |
| 351 | CONDUIT & OTHERSupply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 352 | 25 mm |
| 353 | 32 mm |
| 354 | SITC of 16A / 20A Single Phase IP66 industrial Plug Point with metal clad plugSocket / plug top with 20A DP MCB including weather proof box cover plate etc, complete in all respect, includeswitch, box, plate, etc. equivalent to Legrand Make Cat No. 056661 |
| 355 | SITC of 25A Three Phase IP66 industrial weather proof Plug Point with metal clad plugSocket / plug top with 32A FP MCB including weather proofbox cover plate etc, complete in all respect, includeswitch, box, plate, etc. equivalent to Legrand Make Cat No. 056674 |
| 356 | EARTHING |
| 357 | G.I earth plate elctrode:Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal or coke and saltas required |
| 358 | S/L SWG GI wire in ground:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 359 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 360 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 361 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. |
| 362 | LIGHT FIXTURES |
| 363 | 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make BN021C LED20S PSU CW GR S2 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.Approved Makes-Philips/Wipro/K-Lite |
| 364 | 18W, 2000 Lumen Surface mounted LED Down light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Surface mounted LED Down light fixtures equivalent to Philips make SM251C LED20S complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.Approved Makes-Philips/Wipro/K-Lite |
| 365 | 18W, 2000 Lumen Recess mounted LED Down light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Recess mounted LED Down light fixtures equivalent to Philips make DN296B LED15S-6500 PSU WH complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.Approved Makes-Philips/Wipro/K-Lite |
| 366 | Mirror Light (Wall mounted LED Light):Supply, Installation, assembling, connection, testing & commissioning of wall mounted LED Light suitable for 7.5W luminairealong with all other necessary accessories. Equivalent to philips 34034/14/86. IP44.Approved Makes-Philips/Wipro/K-Lite |
| 367 | Weather Proof Downlighter : Supplyof CEILING LED Fixture -LED 12W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage& Over- Current, IP 66 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum.Approved Make - Orient/Philips/Bega |
| 368 | Supply of Weather Proof Downlighter (On Roof Chajja)Recessed Celiing Light - 10W,800lm,IP65,3000K, Dimension 100X80mm, Height 80mm Diameter is 100mm, Weight is 0.5kg, Fixing Suitable for ceiling-mounted recessed installation. Fixture ismade of Die Cast Aluminium, Powder Coated, LED is COB, Inbuilt driver, Input AC 240V, 50/60HzApproved Make - Orient/Philips/Bega/NCRL-10S Neri Model NCRL-10S |
| 369 | Bulk Head:upply, Installation Testing and Commissioning of LED bulk head light fitting of 6w/10w having System Efficacy >110 lm/W, system output >700 Lumens for 6W & 1100 lumens for 10W, THD <10%, Power Factor >0.95, CRI >80, CCT 6500, Full IP 66 protected single piece die cast aluminium housing having toughned PC with Impact resistanceIK09, Life L70B50 @ 50k hrs . BIS compliant driver, EMC -EMI compliant. Driver shall have 2.5KV Surge protection. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. BIS certificate for driver as well as the luminaire must be submitted for records. Driver and luminaire shall be of same make. Similar to Philips WT202W LED6S CW PSU S2 PC |
| 370 | Up & Down LightSupply of 2X10 W LED Up down light suitable for wall mounting , BIS approved , Body made of pressure Die cast aluminium , proper heat sink should be designed for better heat dessipation , The diffuser should be clear toughnedglass with IK08 protection . The luminaire is provided with surge protection of 4 KV . Electronic driver having power factor>0.95, THD <15 % and input voltage range from 150-270V AC at 50Hz. Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 as per ANSI,LED Make CREE/Osram/Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with70% of initial lumens maintained.Ambient Operating Temperature is -10 Deg. to 50 Deg. Luminaire should Maintain Ingress Protection of IP65 for better weather proofing. Sample Should be submitted for concerned engineer incharge for approval of light fixture. Approved Make - Orient/Philips/Bega along with all other necessary accessories. |
| 371 | Supply of Landscape Bollards 9Watts Bollard LED, IP66, 800/100mm. Approved Make - Orient/Philips/Bega |
| 372 | Uplighters (Spike Light) :Supply of Projector Light-LED 9W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage& Over- Current, IP 65 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting ALwith Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9004 + RAL 9018 Matt,Dimension-140mm(Dia.)x196mm(H),without fixing bracket Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum.Approved Make - Orient/Philips/Bega |
| 373 | FIXTURE - 40-45W Power Module LED: Supplyof post top light fixture equivalent to LED FIXTURE - 40-45W Power Module LED, -MOUNTED AT 4 METER HEIGHT POST TOP POLE :it\"s - Upper frame made in die-cast and sheet aluminium (thickness: 2.5mm), with threaded coupling G3/4\" for fixing,Bottom frame with ring made in die-cast aluminium and two arms made in hotgalvanized steel, with flange for fixing equipped of a hole (diam. 28 mm) .Gasket between the upper and bottom frames.Painted with polyester powder coating in Metallaic Grey (As per Architectural requirement). IP Rating - IP 66.Height –690mm, Dia - 550mm, Weight - 11.5Kg, Area Exposed to Wind(S) - 0.105 m2. Power LED\"s Module (with CREE/NICHIA/OSRAM/SEOUL SMD type LED’s with ESD=>8kV & Ceramic package are accepted. LED manufacturers tech sheet with buying documents should be submitted for verification. Individual LED\"s Minimum Luminous Flux (lm) is 139lm @ 350 mA (@ 85 °C) same should be supported by LED manufacturer\"s tech sheet) in compliance with IEC 62031(supporting type test report should be submitted), on Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 1.5kv(an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens (Polycarbonate), UV Resistant & Shock Resistance IK10.LM80 Reported LED Lifetime is L90@ 50,000hours minimum.(same should be supported by LM 80 report from NVLAP accredited lab) & Estimated LED Lifetime is L80 @ 100,000 hours(Ta-25°C) minimum..LM 80 report & TM 21 calculation should be submitted to support the same.The Light fixture shall be in compliance with IEC 60598-2-3; IEC 60598-1.(Supporting Test Report from NABL accredited Laboratory should be submitted) .LM79 report should be submitted from NABLaccredited Laboratory. Sample should be submitted for approval from concerned engineer-in charge. Approved Make - Orient/Philips/Bega/NERI |
| 374 | Supply of ARCHITECTURAL POLE (FOR POST TOP & INDIRECT LIGHTING) 3.3M height Pole (Total height of the pole is 4m including post top) Made in combination of hot dip galvanised mild steel pipe sections 114mm dia. & 140mm dia. Arch. cast iron Base design starts with min 322mm Dia. ring, radially tapers to 140 mm for a height of min 235 mm matching to the drawing. Total weight of the base is min 15 Kgs. Decorative Ring-1 (140/114mm dia. – min 3kgs.) & Top Ring (weight- 3kgs.) are made of cast iron. Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box (Concealed) to fix 32A connectors and 6A MCB (to terminate incoming and outgoing armoured cables with glands and lulgs), at the bottom -the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it\"s parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint- customised colour Metallaic Grey (As per Architectural requirement). Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, cable termination, earthing as per requirement, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc. all require to complete job.Approved Make - Orient/Philips/Bega/NERI |
| 375 | 3.3M HEIGHT HERITAGE SMART POLE FOR INDIRECT LIGHTING3.3M height Pole Made in combination of Multiple Modules made ofmild steel pipe sections 270mm dia. & multiple suitable Cast Iron embellishments like base & rings.Smart features/services such as CCTV dome type camera, PAS-1nos.(Bose spekaer AMU), USB charger, SOS emergency button, WIFI device/router should be inbuilt inside the pole .Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge.After Fabrication, MS pipe modules are hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the poledesign.Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, cable termination, earthing as per requirement, cable entry pipes, astronomical timer with contactor for light on-off, 3 core round flexible wire from junction box to light fixture etc. all require to complete job. Pole & Cast iron parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint. Price shall be inclusive of following items:Speakar - 1 Nos. (each pole)Bose AMU speakerCCTV - 2Nos. (Each pole)IP 3 MP (20 fps) & Full HD 1080p (25/30 fps) image with 1/3\" 3 MP sensor, true widescreen image on a 16:9 display,True Day/Night vision,IR LEDs provide up to 30 m (100 ft) of illumination in night,Smart IR technology,IP66 & IK10housing,Small form factor, inconspicuous after installation,2.7–12 mm F1.4 motorized focus/zoom lens, 1Gbps SFP Module, Media Converter (Fiber to UTP), Cat-6 Cable within pole, etc. (including all as require) Equivalent to Avtron/Honeywell/BOSCH/Hikvision.WiFiThe Dual Band(2.4GHz & 5 GHz)Wi-Fi system .It provides simultaneous,dual-band,MIMO technology . dual-band omnidirectional antennas deliver expanded range coverage outdoors. The primary port is for data and POE, Equivalent to NETGEAR WND930SOSSOS button provided for users To avail the Emergency services .USB chargerWaterproof USB Dual Charge Socket with 5V DC Output.USB Input Voltage Range,12-24V,USB Output Voltage5V +/- 5%,Output Current-2x 2.1A (4.2A Total) Raiting,IPX6 waterproof,Metals-316 stainless steel,Plastics,ASA,Internal Coating-Anti-corrosion,External Coating-UV resistant. Approved Make - Orient/Philips/Bega/NERI |
| 376 | Supplyof exhuast fan (250mm)with 6 blade,plastic Housing and Gravity Shutter.Approved Makes-Havells/Usha/Almonard/Orient |
| 377 | JUNCTION BOXES |
| 378 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE |
| 379 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal equivalent to Hensel catalogue no KF 1610 G/OBO/CAPE |
| 380 | Supply, Transportation, Installation, testing and commissioning ofIP 67 weather proof Outdoor type junction boxes with terminal equivalent to Hensel catalogue no KF 1616 G/OBO/CAPE |
| 381 | DWC PIPES |
| 382 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. |
| 383 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 384 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 385 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 386 | UPSSupply installation Testing and commissioning of 6 KVA (SINGLE PHASE) on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output with minimum 15 minutes battery back up of each UPS.Approved Makes-Eaton, Neumeric, APC |
| 387 | CABLE TRAY |
| 388 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 389 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 390 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 391 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 392 | FIRE STOPPER & SAFETY ITEMS |
| 393 | Supply and application of intumescent based coating on cables/ cable tray using Hilti CP 678 or equivalent make, firestop cable coating of HILTI make or equivalent .The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992). |
| 394 | Supply and installation ofrodent and termite proof Fire Barriers equivalent to Hilti CFS COS on both sides of wall ( Composite Sheet) system for 2 hours fire rating when tested in accordance with ASTM E 814/UL 1479 standards. The Composite Sheet 3.81 mm thick, bonded with organic/inorganic fire-resistive elastomeric #SS 304 (Stainless steel) sheet. One side it should be bonded with 26 gauge #SS 304 (Stainless steel) sheet and the other side it should be reinforced with hexagonal shaped #SS 304 (Stainless steel) wire mesh and covered with aluminum foil for the penetrants and the big opening. The small gaps left around the penetrants should be closed with Intumescent sealant FS One max of equivalent to Hilti make, or with Fire rated Moldable Putty CP 619T of equivalent to Hilti make, which should be soft & moldable to any shape, to give complete L Rating. This system is to seal all fire rated horizontal in Floor made of concrete, masonry, metal, gypsum partition, after passing service lines like cables/cable bundles, cable trays etc. The system shall be UL & FM approved. |
| 395 | Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system shall be UL & FM approved. |
| 396 | Supply and installatio of Acrylic Firestop Sealant equivalent to Hilti CP 606 in gaps between wall and slab made of concrete/masonary/gypsum on both sides of wall to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. The product shall be age tested as per Dafstb and DIBT standards.Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. |
| 397 | Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam. |
| 398 | Providing and fixing printed instruction chart both in English, Hindi, local language and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\" diagonally size. |
| 399 | Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. |
| 400 | Supplying rubber matting of 3 mm thickness as per IS 15652 and IEC 61111.(A) 3 mm |
| 401 | Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes) |
| 402 | Supplying FIREbucket round bottom of9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside andRed out side with FIRE mark,filled with dry-sand and kept on existing stand provided or hung on wall hook. |
| 403 | Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mmheight frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint. |
| 404 | Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms. |
| 405 | LIGHTNING PROTECTION SYSTEM |
| 406 | Contractor to design lightening protection system along with SITC work. Contractor also need to submit Risk Analysis report based on site condition and location. Contractor to take soil resistivity report and necessary consideration to be taken along with below items. In general, the complete system design and installations shall confirm to latest IEC/IS Standards and the specifications, drawings submitted here with. Quantity and items mentioned here under is just for reference;Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall include all necessary accessories to comply the installation and design to IS/IEC 62305 requirements, which broadly includes all system requirement. |
| 407 | AIR TERMINAL |
| 408 | Supply, Installation, Testing and Commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No.RD 8/ALU (5450 08 6) |
| 409 | Supply, Installation, Testing and Commissioning of Roof conductor holderfor parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distanceOBO Type No.177 30 M8(5207 46 0 ) |
| 410 | Supply, Installation, Testing and Commissioning of bonding base forRoof conductor holderforroof - Polyamide Conductor holder:OBO Type No.194 (5207 25 8 ) |
| 411 | Supply, Installation, Testing and Commissioning of cross universal connector: For T and cross connection,to route vertical down conductor /mesh formation made of hot dipped galvanisediron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . OBO Type No.251 8-10 ( 5312 03 5 ) |
| 412 | Supply, Installation, Testing and Commissioning of Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 ) |
| 413 | Supply, Installation, Testing and Commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). OBO Type No. 249 8-10 ST ( 5311 50 0 ) |
| 414 | Supply, Installation, Testing and Commissioning of Bridging cable:From flexible CU cable of 16mm2 with black colur coating, chlorinated India rubber mixture .Exclusively used for indoor & outdoor application to make continuity at terminals.OBO Type No. 853 300 ( 5331 01 3) with 319 8 Clamping Shoe, 8 mm (5325 307) |
| 415 | Supply, Installation, Testing and Commissioning of Bridging cable:From flexible CU cable of 16mm2 with black colur coating, chlorinated India rubber mixture .Exclusively used for indoor & outdoor application to make continuity at terminals.OBO Type No. 853 300 ( 5331 01 3) with 319 8 Clamping Shoe, 8 mm (5325 307) |
| 416 | Supply, Installation, Testing and Commissioning of1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. |
| 417 | DOWN CONDUCTOR |
| 418 | Supply, Installation, Testing and Commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.OBO Type No. 5052 DIN 30X3 ( 5450 43 6) |
| 419 | Supply, Installation, Testing and Commissioning of diagonal clampsuitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 250 A FT ( 5313 01 5 ) @every1mts |
| 420 | Supply, Installation, Testing and Commissioning of Cross connector for earth fixing point suitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 250( 5312 90 6 ) |
| 421 | Supply, Installation, Testing and Commissioning ofEarth fixing point of OBO type No. 250 DG-L180 (5420022) |
| 422 | Supply, Installation, Testing and Commissioning of Connector, Rd 8-10 mm with pressure trough with 1 fix contact clamping screw, nut and serrated washer Including pre-mounted pressure sump, steelConforms to the requirements according to DIN VDE 0185-305 (IEC 62305). Used to connect the aluminium conductor with the earth fixing point. OBO Type no : 249 8-10 ST-OT (5311 50 3) |
| 423 | Supply, Installation, Testing and Commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by EngineerOBO Type No. 271 8-10VA ( 5317 48 1 ) |
| 424 | Supply, Installation, Testing and Commissioning of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6.OBO Type No. LSC I+II ( 5091 72 2 ) |
| 425 | RING & VERTICAL EARTHING SYSTEM |
| 426 | Supply, Installation, Testing and Commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. OBO Type No. 5052 DIN 30X3( 5450 43 6) or equivalent as per make. |
| 427 | Supply, Installation, Testing and Commissioning of diagonal clamp suitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 250 A FT ( 5313 01 5 ) or equivalent as per make. |
| 428 | Supply, Installation, Testing and Commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4 ) or equivalent as per make. |
| 429 | EARTH KIT |
| 430 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit |
| 431 | SURGE PROTECTION DEVICES |
| 432 | Supply, Installation, Testing and Commissioning of combination surge arresters Class B+C according to IEC 61643-1 for the lightning protection zone 0-2 consisting of din mountable - one common base consisting of 1 numbers of modular pluggable units of high energy varistor based technology to be connected between line to neutral and 1 number of GDT to be connected between neutral to earth complying the below technical parameters:a) Nominal voltage between L-N, Un = 230 voltsb) Maximum continuous operating voltage between L-N, Uc = 320 voltsc) Maximum continuous operating voltage between N-PE, Uc = 255 voltsd) Lightning Impulse Current (L-N), Iimp (10/350 micro sec) = 7 KAe) Lightning Impulse Current (N-PE), Iimp (10/350 micro sec) = 25 KAf) Nominal discharge current In (8/20 micro sec), (N-PE) = 30 KAg) Max discharge current Imax (8/20 micro sec), (L-N) = 50 KA&(N-PE) = 50 KAh) Voltage Protection Level, Up = < 1.3 KV (L-N), < 1.2 KV (N-PE)i) Response time, tA = < 25 (L-N) &< 100 (N-PE) nano secondsj) Working condition of the SPD - Visual indication = Green “OK” & Red “Failure”k) Temp Range, -40° C to +80° C l) Degree of Protection IP 20 or equivalent as per make. |
| 433 | FIRE DETECTION SYSTEM |
| 434 | Design, Supply, Install, Testing of all Fire Alarm Components and Commissioning of a Complete New Automatic Analog Addressable type Fire Alarm and Detection System complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest NFPA guidelines and the specifications, drawings submitted here with.Note : - Quantity mentioned here under is just for reference;Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall allow for all necessary accessories to comply the installation and design to IEC requirements, which brodally includes all necessary hardware and software. |
| 435 | Supply, Installation, Testing And Commissioning of Two Loop Addressable Fire Alarm Control Panel having capacity of 200 devices of any combination, shall having Netwroking facility with other panel & center graphics software.Approved Makes- Honeywell / Simplex / Siemens |
| 436 | Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Copper armoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC |
| 437 | Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Copper unarmoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC |
| 438 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 439 | Supply, Installation, Testing And Commissioning of One Addressable Multi Sensor Detectors Below Ceiling with mounting base and all required accesories.Approved Makes- Honeywell / Simplex / Siemens |
| 440 | Supply, Installation, Testing And Commissioning of One Addressable Multi Sensor Detectors Above Ceiling with mounting base and all required accesories.Approved Makes- Honeywell / Simplex / Siemens |
| 441 | Supply, Installation, Testing And Commissioning of Response Indicator for indication of ABOVE false ceiling detector activation.Approved Makes- Honeywell / Simplex / Siemens |
| 442 | Supply, Installation, Testing And Commissioning of One Addressable Manual Call Pointwith all required accesories.Approved Makes- Honeywell / Simplex / Siemens |
| 443 | Supply, Installation, Testing And Commissioning of Addressable Hooter with Strobe having 95 db sound and 110 cd.Approved Makes- Honeywell / Simplex / Siemens |
| 444 | Supply, Installation, Testing And Commissioning of Addressable Isolator Module. Approved Makes- Honeywell / Simplex / Siemens |
| 445 | Supply, Installation, Testing And Commissioning of Addressable Control Module. Approved Makes- Honeywell / Simplex / Siemens |
| 446 | Supply, Installation, Testing And Commissioning of Addressable Monitor Module. Approved Makes- Honeywell / Simplex / Siemens |
| 447 | SITC of connectors and connection Cables required to complete the Job:- |
| 448 | PUBLIC ADDRESS |
| 449 | Design, Supply, Install, Testing of all Public Address Components and Commissioning of a Complete Public Address/EvacuationSystem complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC Standards and the specifications, drawings submitted here with. |
| 450 | Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Shielded Copper armoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC |
| 451 | Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Shielded Copper unarmoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC |
| 452 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 453 | 6W Ceiling Speaker: Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W Approved Makes- Honeywell / Simplex / Siemens / BOSE |
| 454 | Weather Loudspeakers-80W: Supply, Installation, Testing and Commissioning of Bose AMU 105 for All Weather Loudspeakers-80W with all necessary accessories to comply the installationApproved Make - Bose / Honeywell / Simplex / Siemens |
| 455 | Zone Controller :Supply, Installation, Testing and Commissioning of 6 Zone Controller Approved Makes- Honeywell / Simplex / Siemens / BOSE |
| 456 | Power Amplifiers: Supply, Installation, Testing and Commissioning of 240W amplifier, and 4-16 Ohms transformer isolated, Frequency responce 60 Hz~15 kHz ( ± 3 dB ), LED status indicators, Including DC12V fan, Rated Power 480W, Require Power AC 220 V / 50 Hz, DC protection.Approved Makes- Honeywell / Simplex / Siemens / BOSE |
| 457 | Design, Supply, Installation, Testing and Commissioning of 8 Zone Voice Evacuation & Alarm Controller. 8 Zone Paging Station, Built-in USB, MP3 & AM/FM Player, Adopts LCD Screen for easy operation, Simple integration with Fire Alarm Panels to activate EVAC/ALERT pre-recorded messages, 1 line input, 1 microphone input, provides mix and emergency paging output modes, 1 alarm activation input and 1 timing activation inputm. Its own PTT microphone.Approved Makes- Honeywell / Simplex / Siemens / BOSE |
| 458 | SITC of connectors and connection Cables required to complete the Job:- |
| 459 | CCTV SYSTEM |
| 460 | Design, Supply, Install, Testing,Commissionnig of CCTV System complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with. |
| 461 | Supply, installation, testing and commissioning of Cat6 cable. Make:- HUBER+SUHNER/SIEMON/PANDUIT/DURANET |
| 462 | Supply, Installation,testing and commissioning of 24Port POE Network Switch to provide Power and Data Communication for mentioned Camera. With 1 G SFP Module.Approved Makes- Honeywell / Simplex / Siemens |
| 463 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 464 | Supply, Installation, Testing & Commissiong of 2 MP IR Dome Camera 1/3? Megapixel progressive scan Exmor CMOS, Infrared, Dome camerawith D/N ICR, IR, varifocal lens, 2.8mm-12mm, F1.6, with Audio, H.264, IP66 rated 720p @ 25fps, H.264: 4–8192 kbps, BLC/HLC/DWDR, IR distance up to 30m, RJ-45 connection, Inbuilt microSD card slot, BLC/HLC/DWDR, 3D DNR, ROI, ONVIF, PoE Complete as per specification, IP66, IK10, Including necessary accessories for mounting.Approved Makes- Honeywell / Simplex / Siemens |
| 465 | Supply, Installation, assembling, connection, testing & commissioning of 5.0 MP 33X IP PTZ Dome camera ,1/.8\" Super Starlight CMOS,2880×1620@30fps, 200m IR ,30x optical zoom, Autotracking & Early warning Speed 0.1°~180°/s, Low Iux 0.0002Lux, TVS 6000V protection; Audio I/O 1/1, Alarm I/O 8/2, RS-485, BNC, Wiper, White light, Green Laser, Built-in speaker ,Face capture mode, Human/vehicle classification MicroSD card(512GB), Onvif Profile S/T/G/M, IP66,,PoE++Equivalent to Avtron/Honeywell/BOSCH/Hikvision. |
| 466 | Supply, Installation, Testing & Commissioning of 16-channel network video recorder (NVR), Real-time recording: Up to 16 channels 1080P @ 4Mbps, Operating System LINUX, H.265, H.264 high quality decoding, RAID-0/1/5/6/10 support, motion detection, 3 USB 2.0 ports, USB storage device, 2 RJ-45 port, 1 RS-232, Hot swap, 2 bay HDDs,Support ONVIF Profile S, HTTP/HTTPS, TCP/IP, RTSP, UDP, NTP, HTTPS, DHCP, IP Search protocols can support Approved Makes- Honeywell / Simplex / Siemens |
| 467 | Hard Drive Disk:SITC ofEnterprise surveilliance HDD 8 TB for 30 days storage at D1 resolultion. Approved Makes- Honeywell / Simplex / Siemens |
| 468 | Supply, Installation, Testing and Commissioning of industrial type 32\" LED Display for 24x7 runningg (ON), 1920 X 1080 Resolution, 450 CD/M2 Brightness, Wall Mounting Bracket. Approved Makes- Honeywell / Simplex / Siemens |
| 469 | SITC of connectors and connection Cables required to complete the Job:- |
| 470 | DATA NETWORKING (PASSIVE PART ONLY) |
| 471 | Design, Supply, Install, Testing and Commissioning of all Data NetworkingSystem complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with.Note : - Quantity mentioned here under is just for reference;Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall allow for all necessary accessories to comply the installation and design to IEC requirements, which brodally includes all necessary hardware and software. |
| 472 | RJ-45 socket outlet point with back box, plate, etc. all require to complete job. Approved Makes- Honeywell / Simplex / Siemens |
| 473 | CAT-6 (Systemax) cable for computer socket outlets from data switch to computer point laid through raceways/conduits/floor trunks etc with required termination arrangment to complete the Job. (Rates of raceways/conduits/floor trunks shall be excluded)Make:- HUBER+SUHNER/SIEMON/PANDUIT/DURANET |
| 474 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 475 | Supply, Installation, Testing and Commissioning of 24 Port 10/100/1000 Mbps Gigabit network MANAGABLE swicthes with IEEE 802.3x Flow Contro & RoHS compliant along with SFP portfo network switches. Approved Makes- Honeywell / Simplex / Siemens |
| 476 | Supply, Installation, Testing and Commissioning of 1 mtr. Cat 6 Patch cord. Approved Makes- Honeywell / Simplex / Siemens |
| 477 | Supply, Installation, Testing and Commissioning of 2 mtr. Cat 6 Patch cord. Approved Makes- Honeywell / Simplex / Siemens |
| 478 | Supply, Installation, Testing and Commissioning of 24 Port fully loaded patch panelApproved Makes- Honeywell / Simplex / Siemens |
| 479 | Supply, Installation, Testing and Commissioning of Wirelss Access Point shall have IEEE 802.11ac, 802.11n, 802.11g, 802.11b, 802.3af, 802.3u, 802.1X (security authentication), 802.1Q (VLAN),802.1D (Spanning Tree), 802.11i (WPA2 security), 802.11e (wireless QoS), IPv4 (RFC 791), IPv6 (RFC 2460),LAN Gigabit Ethernet auto-sensing,10/100/1000 Ethernet, with support for 802.3af /at PoE, power port for AC adapter (included) Make :- CISCO,NetGear,HP |
| 480 | Wall mounted network Rack for 12U switch mounting with fixing accessoriesApproved Makes- Honeywell / Simplex / Siemens |
| 481 | SITC of connectors and connection Cables required to complete the Job:- |
| 482 | FIBER OPTIC & DWC PIPE |
| 483 | Supply, Installation, assembling, connection, testing & commissioning of Fiber Optic Single Mode 12 core outdoor with all necessary accessories to comply the installation.Approved Makes- FINOLEX AND REPUTED MAKES |
| 484 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 485 | ACCESSORIES FOR PUBLIC ADDRESS SYSTEM OF SMART POLE |
| 486 | SITC of Multi Channel Networkable Digital Amplifier with Dante , Amplifier capacity 4x500W. Approved Makes-Bose-PM Dan Card |
| 487 | SITC of Dante Cards for PowerMatch Amplifiers. Approved Makes-Bose-PM Dan Card |
| 488 | SITC of 12 input and 8 out Digital Signal Processor with Dante. Approved Makes-Bose-EX-1280 |
| 489 | SITC of Master control for Digital Signal Processor. Approved Makes-Bose-CC-64+CCPS1 |
| 490 | SITC of Paging Microphone. Approved Makes-Beyerdynamic-Classis GM315 SP + GMS32 |
| 491 | SITC of 10-12 AWG speaker cable. Approved Makes-Kramer /Profigold / Legrand |
| 492 | SITC of Network Switch. Approved Makes-Cisco / HP / Alcatel |
| 493 | SITC of CAT6 CABLE (1 lot=309 m). Approved Makes-CommScope / Polycab / Panduit |
| 494 | SITC of Music Player. Approved Makes-Sony / Philips / Samsung |
| 495 | SITC of Rack. Approved Makes-Tata Trynox / Vertive / Panduit |
| 496 | SITC of 6 Core Fiber cable connecting Control Station / Racks. Approved Makes-CommScope / Polycab / Panduit |
| 497 | SITC of Audio Line Cable, Connectors, accessories etc. |
| 498 | SITC of control panel for SOS Panic Switch with2 zone that Connection of up to total 256 devices with 01 Nos Hooter In Control Room, The module is automatically identified by the control panel and is run in default operating mode. The wiring of peripherals is connected by pluggable screw terminals, Auto-detection of zones. Operating voltage 20 V DC to 30 V DC Mechanics, Display element 14.5 cm (5.7”) multi-color TFT display, Operating element Touch screen, Interfaces must be, Ethernet,USB,RS232.Make:Bosch/SIemens-Fire finder/Edward |
| 499 | SITC of connectors and connection Cables required to complete the Job:- |
| 500 | CCMS SYSTEM |
| 501 | ConductingDetailed Site survey, Submission of Detailed Project report, Execution of Design, supply, manufacturing, inspection & testing at manufacturer’s works in accordance with agreed QAP, packaging, delivery to site; handling at site – unloading, storage, shifting from point of unloading to store, storage and from store to the installation site; cleaning, assembly, touch up painting; installation at site; inspection & testing and commissioning for the equipment and systems of LED Smart Lighting system for one loop road with all accessories, mounting arrangement including Centralized Control and Monitoring System (CCMS) of selected Roads in the Badrinath. The Scope shall contain, (a) Provide all necessory items for LED Luminaire if require for working of CCMS;(c) Connecting Cabling laid in DWC pipes ; (d) Earthing system ; (e) Outdoor Feeder Pillars (OFP) with IP 65 with CCMS & Smart Controller for Group Control and Monitoring System ; (f) Excavation of trench or Horizontal Drilling for laying DWC pipes;(g) Communication of Data from Field to Server ;(h) Cloud registration; hosting; uploading and managing all data after Mapping of Feeder Pillars and Light fittings as applicable installed by BIDDER; (i) All civil works associated with installations of the equipment/systems ; (j) Any other electrical equipment/ component which are not specifically listed above but are necessary for Roads in badrinath; Lengths mentioned in the BOQ are Tentative, Need to be ascertained by the BIDDER during Survey.Scope also includes all nessosary cummication cables, etc. require to complete the system.(approx road length is 2 km, however contractor to do survey for exact road length). Contractor to check compability of light fixture with CCMS system. |
| 502 | CCMS SYSTEM |
| 503 | Operation and maintenance of LED SmartLighting and Centralized Control and Monitoring System of one loop Roads for 1st (First) Year from the date of Acceptance including setting up of call centre; maintaining a service team, spare parts and providing service 365 days as per requirement.- 1st Year |
| 504 | Operation and maintenance of LED SmartLighting and Centralized Control and Monitoring System of one loop Roads for 1st (First) Year from the date of Acceptance including setting up of call centre; maintaining a service team, spare parts and providing service 365 days as per requirement.- 2st Year |
| 505 | Operation and maintenance of LED SmartLighting and Centralized Control and Monitoring System of one loop Roads for 1st (First) Year from the date of Acceptance including setting up of call centre; maintaining a service team, spare parts and providing service 365 days as per requirement.- 3st Year |
| 506 | Operation and maintenance of LED SmartLighting and Centralized Control and Monitoring System of one loop Roads for 1st (First) Year from the date of Acceptance including setting up of call centre; maintaining a service team, spare parts and providing service 365 days as per requirement.- 4st Year |
| 507 | Operation and maintenance of LED SmartLighting and Centralized Control and Monitoring System of one loop Roads for 1st (First) Year from the date of Acceptance including setting up of call centre; maintaining a service team, spare parts and providing service 365 days as per requirement.- 5st Year |
| 508 | BOOM BARRIERS |
| 509 | SITC of Motorised Vehicle Barrier complete with Control Unit and integrated Two channel Loop Detector and Boom of 4.5 Meters length with 2 Sec Opening/ Closing time and with Maximum Power Consumption of 90 Watts.All Aluminium Housing with Base frame in SS-304 for high protection against corrosion. All Housing and internal parts will be rust & corrosion free metals or alloys of high strength with suitable Epoxy coatingas applicable.The barrier shall use a Blockable DC High Torque Drive in combination with CAN bus communication standard interfaced Controller. It should be IP 54 rated. It shall offer LCD Display & Graphic User Interface for easy control setting. Possibility for integration via standard user interfaces. Control Panel Should be at the TOP of the housing. TCP/IP and RS485 interfaces.Operating ambient temperature up to -30°C +60°C.Compatible with card reader system,code or biometric devices. Quoted price shall be inclusive of cabling between the Boom Barriers and the motor control center, card reader, push button, loop detector, controller & all necessary accessories. |
| 510 | Fire fighting system |
| 511 | 6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI markedfitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 512 | ISI marked (IS:15683) portable fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in allrespectsincluding initial fill and wall suspension bracketsProviding & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 513 | ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 514 | ISI marked Fire Extinguisher, Dry Chemical powder type capacity 6 kgs conforming to IS : 2171 including first fill & wall suspension bracket.Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 515 | Supplying and installing at approved location approved make fire buckets (3 nos./set) of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and black on the bottom, inscribed with letters \"\" FIRE\"\" in black and gold with dry clean fire sand. The scope shall also include the stand for mounting the sand bucket. |
| 516 | ProvidingAUTOGLOWSignagesinBlock/Small Letters of Specified Sizes:Emergency exit size: 4\" X 12\" |
| 517 | ProvidingAUTOGLOWSignagesinBlock/Small Letters of Specified Sizes:\"ABC\" Extinguisher: 8\" X 4\" |
| 518 | ProvidingAUTOGLOWSignagesinBlock/Small Letters of Specified Sizes:\"CO2\" Extinguisher: 8\" x 4\" |