Tender For Construction Of Proposed Dog Squad Near Nabanna- Balance Works., howrah-West Bengal

West Bengal State Police Housing Corporation Limited has published Tender For Construction Of Proposed Dog Squad Near Nabanna- Balance Works.. Submission Date for this Tender is 13-03-2023. Civil Work Tenders in howrah West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

36321593
Tender For Construction Of Proposed Dog Squad Near Nabanna- Balance Works.
Open Tender
Indian
West Bengal
howrah
13-03-2023

Tender Details

Construction Of Proposed Dog Squad Near Nabanna- Balance Works. ( 1St Call )

Key Value

Document Fees
Refer document
EMD
INR 653780.0 /-
Tender Value
INR 3.26 Crore /-

BOQ Items

Name of Work:Construction of Proposed Dog Squad near Nabanna- Balance Work. (1st Call)
Sl. No. Item Description
1Civil works
2Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
3Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mm
4Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quality of work) (a) With earth obtained from excavation of foundation
5A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
6Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) (iii) With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth.
7Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
8Brick soling with picked jhama bricks including preparation of bed asnecessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. (a) Single brick flat soling (thickness 75 mm.)
9(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
10Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
11Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety
12Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
13Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure ground floor
14125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
15Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thk Plaster a). In ground floor
16Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 15 mm thk Plaster a). In ground floor
17Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 10 mm thk Plaster a). In ground floor
18Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) â 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
1918 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding & polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]
20Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]
21Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative
22Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
23Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr"s hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N
24Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix followingI.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In Ground Floor and Foundation (ii) With approved concrete pump
25Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In Ground Floor: two coats
26Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground Floor: Premium 100% Acrylic Emulsion
27Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) In Ground Floor:
28Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor) Two Coats Solvent based interior grade Acrylic Primer
29Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
30Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
31Labour for Chipping of concrete surface before taking up Plastering work.
32Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) (i)For work in foundation,basement and and upto roof of Ground Floor/upto 4m (I. SAIL/ TATA/RINL
33M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For roof truss worksa) Span up to 12 Mtr
34Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet
35Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian
36Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. a) 35 mm thick shutters (single leaf)
37(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
38Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. 66mm x 90mm
39Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. i) 32 mm thick
40Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
41Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4mm thick clear glass.
42Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass.
43(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above
44Supplying, fitting, fixing G.I chain link fencing 75 mm x 75 mm mesh 12 g wire to the R.C.C or wooden posts with galvanised hooks or staples etc. complete as per direction.
45Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mmapart complete in all respect as per design including cost of all labour and materials
46(a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary.
47Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as "C" clips, R.B.T clips etc.). (The rate is exclusive of the cost of posts)
48M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
49Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
50Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.
51(b) Supplying "Godrej" mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
52ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
53Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cutslots of Main Runner at a regular interval of 600 mm to form amodular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U- 1520).
54(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
55(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
56(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
57(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
58(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer"s specification for water proofing layer in water tank etc. (No Departmental Cement is required)
59Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) (ii) Coloured Decorative
60Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in- Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
61Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. ncluding necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (ii) 30 mm. thick
62Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
63Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 20 mm
64Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 25 mm
65Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 32 mm
66Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 40 mm
67Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to code no. 542 (N) & model Tropical / Sumthing special to ESSCO or similar brand.)
68Supplying, fitting and fixing shower of approved brand and make. Chromium plated Shower Arm 240mm long (Equivalent to code no. 536(A) & Model Tropical / Sunthening Special of Essco or similar Brand)
69Hand Shower ( Health Faucet) with 1 mtr Flexible Tube with wall Hook( Equvalent to Code No. 573 & Model- ALLIED of Jaquar or similar)
70Supplying, fitting and fixing Peet"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I marking with fittings (Tested to 21 kg per sq. cm.) 40 mm dia
71Supplying, fitting and fixing Peet"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I marking with fittings (Tested to 21 kg per sq. cm.) 32 mm dia
72Supplying, fitting and fixing Peet"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I marking with fittings (Tested to 21 kg per sq. cm.) 25 mm dia
73Supplying, fitting and fixing bibcock or stop cock ii) Chromium plated Bibcock Long body with wall flange with areator (Equivalent to Code No. 512 & model Tropical / Sumthing special of ESSCO or similar brand)
74Supplying, fitting and fixing bibcock or stop cock i) Chromium plated Angular Stop Cock with wall flange (Equivalent to Code No. 5053 & model Florentine of Jaquar or similar brand)
75Supplying, fitting and fixing of 32mm PVC Waste Nozzle with Jam Nut, Full or Half Tread Complete.
76Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
77Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (c) 1500 litre capacity
78Labour for hoisting plastic water storage tank. Upto 1500 litre capacity. Upto 1st story from G.L.
79Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I brackets on 75 mm x 75 mm wooden blocks, C.P waste fittings of 32 mm dia, one approved quality brass C.P Pillar cock of 15 mm dia, C.P chain with rubber plug of 30 mm dia, approved quality PVC waste pipe with C.P nut 32 mm dia, 900 mm long approved quality PVC connection pipe with heavy brass C.P nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm x 400 mm
80Supplying, fitting & fixing approved brand PVC Connector white flexible, with both ends coupling with heavy brass CP nut, 15 mm dia 450 mm long
81Supplying, fitting & fixing approved brand PVC Connector white flexible, with both ends coupling with heavy brass CP nut, 15 mm dia 600 mm long
82Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm
83Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (c) 160 mm
84Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (iii) Door Tee (b) 110 mm
85Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (iii) Door Tee (c) 160 mm
86Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Door Bend (T.S.) (b) 110 mm
87Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Door Bend (T.S.) (c) 160 mm
88Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xv) Vent Cowl (b) 110 mm
89Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xv) Vent Cowl (c) 160 mm
90Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 v) Plain Y (b) 110 mm
91Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 v) Plain Y (c) 160 mm
92Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A)Above ground (ii) 110 mm dia.
93Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A)Above ground (iii) 160 mm dia.
94Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B)Under ground (ii) 110 mm dia.
95Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B)Under ground (iii) 160 mm dia.
96Supplying, fitting and fixing C.I round grating. 100 mm
97Supplying, fitting and fixing C.I round grating. 150 mm
98Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With "P" trap
99Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. (a) With "P" trap (with vent)
100Supplying, fitting & fixing Flat Back Urinal (half Stall Urinal) in White glazed vitreous chinaware of approved make & brand in position with brass screws on 75 mmx 75mm x75mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
101Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E. W. C. Bestolite (solid type) White
102Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. Anglo Indian (i) Plastic (hallow type) White
103Supplying, fitting & fixing 32 mm dia Flush Pipe of approved make with necessary fixing materials & clamps complete. CP Flush Pipe
104Supplying, fitting & fixing Urinal Flush Pipe fittings of approved brand. CP Urinal Flush Pipe Fittings range of one
105Supplying, fitting & fixing best quality Indian make Mirror 5.5mm thick with silvering as per IS specifications supported on fibre glass frame of any colour, frame size 550mm x 400mm.
106Supplying, fitting & fixing Towel Rail with two brackets. CP over Brass 25 mm dia & 750 mm long
107Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
108Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL) Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth.
109Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (v) For 100 users A) With Pakur variety. (SAIL/TATA/RINL)
110Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non pressure underground Drainage, Sewerage & Cross drainage application. (iv) 300mm internal dia.
111Electrical Works (Schedule Item) Supply & Fixing 415V 200 A TPN switch (L&T) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.
112Supply & fixing double door type 8 way Vertical TPNMCB DB (Legrand) with IP 42/43 protection SS enclosure recessed in wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire, neutral link & earthing attachment comprising of the following accessories a) 200 A Four pole thermal magnetic MCCB- 1 no b) 63 A TP MCB ---7 nos C) 32 A TP MCB ----1 no
113Supply & fixing 4 way double door horizontal TPN MCB DB with SS enclosure (Legrand/Seimens/ABB) concealed in wall after cutting the wall & mending good the damages to original finish with earthing attachment comprising with the following. a) 63 A Four Pole isolator ---1 No. b)16 to 32 A range SP MCB. ---12 Nos.
114Supply & fixing SPN MCB DB (2+8) WAY (Make legrand/ Seimens/ABB) with S.S. Enclosure concealed in wall after cutting wall & mending good the damages & earthing attachment comprising with the following: a) 40 A DP isolator - 1 No. b) 6 to 16 A range SPMCB - 6 Nos.
115Laying of XLPE/A cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed a) 4x16 sq mm
116Laying of XLPE/A cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed b) 3.5X120 sq mm
117Laying of cable upto 2 core 6 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
118Supply & laying medium gauge 40 mm dia G.I. Pipe (ISI -m) for cable protection.
119Supply & fixing (40mmx40mmx6mm) G I Pole clamp with nuts, bolts & washer for holding vertical 40 mm dia G I cable protechtion pipe from service pole.
120Supply & fixing compression type cable gland suitable for cable with brass gland, brass ring incl.socketing the ends off by crimping method including S/F solderless socket (Dowels value) & jointing materials etc. a) 2X6 sq mm XLPE/A
121Supply & fixing compression type cable gland suitable for cable with brass gland, brass ring incl.socketing the ends off by crimping method including S/F solderless socket (Dowels value) & jointing materials etc. b) 3.5X120 sq mm XLPE/A
122Supply & fixing compression type cable gland suitable for cable with brass gland, brass ring incl.socketing the ends off by crimping method including S/F solderless socket (Dowels value) & jointing materials etc. c) 4x16 sq mm XLPE/A
123Supply & drawing PVC insulated (FR) Copper wire through alkathene pipe recessed in wall & mending good the damages. a) 2X2.5 + 1X1.5 Sqmm. (P/P)
124Supply & drawing PVC insulated (FR) Copper wire through alkathene pipe recessed in wall & mending good the damages. b) 2X4 + 1X2.5 Sqmm.(A/C)
125Supply & drawing PVC insulated (FR) Copper wire through alkathene pipe recessed in wall & mending good the damages. c) 2 x 6+ 1 x 2.5 sq mm through 19mm Alka.Pipe (SPNDB)
126Supply & drawing PVC insulated (FR) Copper wire through alkathene pipe recessed in wall & mending good the damages. d) 3X1.5 sq mm
127Supply & fixing of Modular type plug board of 4 module G.I.box with cover plate recesed in wall Incl. making earthing attachment, painting and mending good damages to building works (all cabtree) a)6A socket - 1no. & 6A switch - 1 no. - 1set.
128Supply & fixing of Modular typeplug board of 4 module G.I.box with cover plate recesed in wall Incl. making earthing attachment, painting and mending good damages to building works (all cabtree) a)16A socket - 1nos & 16A switch- 1 no. - 1set.
129Distn. wiring in 3 x 1.5 sqmm single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/ fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. (avg. 8 mtr run)
130Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded "FR" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. a) (on board)
131Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded "FR" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. b) Ave 4.5 mtr
132Fixing the above Tube light fitting suspended 30 cm. Below the cutting with 2 Nos. 20 mm dia E.I. conduit (14 SWG) support fixed with "L" type clamp fixed on ceiling with fastener & S/F connecting copper wire.
133Fixing the above Tube light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
134Fixing only fan box type clamp of 150 mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, Incl. S&F 12mm dia 600mm long MS rod duly bend by heat treatment at the centre position of rod to grip fan bobbin properly, Incl. binding the rod and fan box with reinforcement by 22SWG steel binding wire, INCL. supplying and covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
135Supply & Fixing electronics step type, Moduler Socket type (2 module), Fan regulator (Cabtree)
136Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.04 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtr long) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level.
137EARTH BUSBAR: S&F earth busbar of galvanised(hot dip) MS flat 25mmX6mm on wall having clearance of 6mm from wall INCL.providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulator etc. as required
138EARTH CONTINUITY CONDUCTOR: Connecting the equipments to the earth busbar INCL. S&F GI(hot dip) wire of size No. 8 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
139Supply & fixing 40mm dia GI(ISI-M) pipe of 1.20 mtr long KMDA type Arm bracket thoroughly welded with 100mm dia 30 cm long vertical jacket with tie support incl S/F pole cap & painting as per direction of the EIC.
140S&F MCB SS enclosure with IP- 20/30 protection, power coated provision for 2 pole MCB concealed in wall after cutting the wall and mending good the damages to the origina finish incl. painting, connection & provision for earthing attachment a) 2 way ------1 No. b) DP MCB -------1 No.
141S&F 240V 20A piano key type switch (band app. By EIC) on sheet metal sw. board incl. S&F 100X100X65 mm MS (16 SWG) sw. boarb and bakelite/perpex top cover of 3mm thick by brass screws after making housing for sw. by cutting bakalite/perpex cover and making necc. conec. as req.
142(NON-SCHEDULE ITEM) Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) a) 2 X 6 sqmm. XLPE /A Cable.
143Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) b) 3.5 x 120 sq mm
144Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) c) 4 X 16 sqmm. XLPE /A Cable.
145Supply & fixing of 1200mm sweep Ceiling Fan (White) complete with all acessaries without regulater (Make Orient, New bridge) Incl S/F necy copper flex wire.
146Supply & fixing 3w LED night lamp on batten light point (Make Wipro)
147Supply of recessed/Surface type 15w LED fitting suitable for false ceiling/Surface (Make Philips/ Crompton, cat no - LSCSM-15W- CDL/NW/WW)
148Supply 4" 20w single LED Box type tube light fitting (Make Crompton, cat no - IGP 131 L-8-16) complete with 1 X 20W Polycarbonate LED Tube (Cat no -LT8-20-865-2)
149LED light for interior and exterior applications within car parks, walkways, corridors, local authorities and housing associations as well ascomercial building (Makes Crompton CAT No. LBHP-10-CDL)
150Supply & fixing only of the following Exhaust Fan (Metal Body) (Make Orient/Crompton/EPC)with louvre shutter after cutting wall & mening good the damages. a) 230 mm (9") sweep exhaust fan (Make EPC, Heavy duty)
151SUPPLY & INSTALLATION OF AC MACHINE Supply & delivery through DGS & D rate contract basic of the following split type AC machines (3 Star rated)(Make Hitachi/Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation etc. a) 1 TR Split type (3 Star rated)
152Supply & delivery through DGS & D rate contract basic of the following split type AC machines (3 Star rated)(Make Hitachi/Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation etc. b) 1.5 TR Split type (3 Star rated)
153Supply & delivery through DGS & D rate contract basic of the following split type AC machines (3 Star rated)(Make Hitachi/Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation etc. c) 2 TR Split type (3 Star rated)
154Supply & Fixing 6 Module flush type with Starter, 25A DP MCB , Plug & top with Indicator OLP(Electron make)
155Installation charge of indoor & out door unit incl S/F iron bracket frame
156Supply & Installation of copper refrigerent pipes, power cable of different dia as required with synthetic insulation complete.
157Supply & installation of extra drain water pipe of approved quality
158Supply & fixing of 90W LED Street light fitting (Make Crompton, cat no - LSTP-90-CDL)
159Supply & fixing of 72W LED Street light fitting (Make Crompton, cat no - LSTP-72-CDL)
160Supply & fixing of 45W LED street light fitting (Make Crompton, cat no - LSTP-45-CDL)
161Supply & fixing of 135W LED street light fitting (Make Crompton, cat no - LFLN-135-CDL/60)
162Supply of Single phase 415V 3-Phase 3 Hp (2.2 Kw) open well Monoblock submersible Pump Motor set suitable for U.G. Resorvoir having overall head of (15 mtr to 27 mtr) & discharge capacity of (450 LPM to 150 LPM). The discharge outlet size will be 40mm (1.5"inch) (Make Kirloskar/KSB)
163Supply & Laying 3 core 2.5 sqmm flat submersible cable (Finolex)
164Supply & Laying OF 25 mm G.I.Pipe .
165Supply & fixing of 415V 32A TPN SFU with sheet steel enclosure on flat iron frame on wall incl. S/F HRC fuses on LS & NL (Make L&T/Siemens)
166Supply & Fixing of control panel suitable for 3-Phase 3 HP Submersible Pump motor set comprising of DOL starter, dual Ammeter & Voltmeter, indicator lamp to be fixed on wall incl making connection & necy. earthing attachment. (Make L&T/KSB)
167Supply & installation of G.I. pipe (Make TATA-M) pipe having heavy duty G.I. socket/elbow (TATA) incl cutting & threading as required a)40 mm dia. medium quality (For Vertical column pipe & upto Header Assembly)
168Supply & fixing 50 mm dia Gun metal Non-Return/Horizontal Check valve (ISI)
169Supply & fixing 65 mm x 50 mm dia G.I. Reducing socket (For delivery Line from header)
170Supply & fixing 50 mm dia PVC Union
171Making holes on wall & mending good the damages to original finish
172Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable & delivery pipe line into the U. G Resovoir including arrangement of tools & Tackles etc. to satisfactory operation.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail