| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable in recessed medium class PVC conduit with modular switch Suitable GI box as required and earthing point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable. (Group-B). |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable in recessed medium class PVC conduit with modular switch Suitable GI box as required and earthing point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Group-C). |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, 2 way modular type switch, suitable size Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. |
| 4 | Supplying and fixing 3pin 5amp ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 5 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 6 | Supplying and fixing 10 A rating, 240/415V 10 KA\"C\" curve miniture circuitbreaker suitable for inductive load of single pole in the exiting MCB DBcomplete with connection testing and commiissioning etc. asrequired. |
| 7 | Supplying and fixing 25 A rating, 240/415V 10 KA\"C\" curve miniture circuitbreaker suitable for inductive load of single pole in the exiting MCB DBcomplete with connection testing and commiissioning etc. asrequired. |
| 8 | Supplying and fixing 32 A rating, 240/415V 10 KA\"C\" curve miniture circuitbreaker suitable for inductive load of Double pole in the exiting MCB DBcomplete with connection testing and commiissioning etc. asrequired. |
| 9 | Supplying and fixing 16 way Double Door Single pole and neutral Sheet Steel MCB Distribution bord 240 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator). |
| 10 | Supplying and fixing 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 11 | Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 12 | Supplying and fixing 100 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 13 | Providing and fixing 200 A rating and 36KA breaking capacity and four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 14 | Providing and fixing 400 A rating and 50KA breaking capacity and four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 15 | Supplying and fixing 5/6 amps modular switchon the existing modular plate and switch box including connectionsbut excluding modular plate etc.as required. |
| 16 | Supplying and fixing2 way 5/6 amps modular switchon the existing modular plate and switch box including connectionsbut excluding modular plate etc.as required. |
| 17 | Supplying and fixing 5/6 amps modular bell push switchon the existing modular plate and switch box including connectionsbut excluding modular plate etc.as required. |
| 18 | Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & box including connections but excluding moduler plate etc. as required |
| 19 | Supplying and fixing 15/16 A modular swich on the existing modular plate and swich box including connections but excluding modular plate etc.as required. |
| 20 | Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate and swich box including connections but excluding modular plate etc.as required. |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on tha existing modular plate swich box including connections but excluding modular plate etc.as required |
| 22 | Supplying and fixing Modular blanking plate on the existing modular plate & swich box excluding modular plate etc.as required |
| 23 | Supplying and Fixing Call bell /Buzzer suitable for single phase 230V. Complete as required. |
| 24 | Supplying and fixing 2 module (75mm+75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required. |
| 25 | Supplying and fixing 4 module (125mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required. |
| 26 | Supplying and fixing 6 module (200mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required. |
| 27 | Supplying and fixing 12 module (200mmX150mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required. |
| 28 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required |
| 29 | Wiring for submain wiring alongwithearth wire with the 2x 2.5 sq. mm+ 1x 2.5 sq.mm earth wire of FRLS PVC insulated copperconductor, single core cable in medium class PVC conduit as required. |
| 30 | Wiring for submain wiring alongwithearth wire with the 2 x 4 sq. mm+ 1x4 sq.mm earth wire of FRLS PVC insulated copperconductor, single core cable in medium class pvc conduit as required. |
| 31 | Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface /recess including cutting the wal and making good tha same in case of recessed conduit as required. |
| 32 | Wiring for submain wiring along withearth wire with the 4 x 16 sq. mm + 2x6 sq.mm earth wire of FRLS PVC insulated copperconductor, single core cable in medium class PVC conduit as required. |
| 33 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) |
| 35 | Supplying and fixing 1200mm Ceiling fan with BLDC motor |
| 36 | Supplying and Fixing 20W LED tube light with integrated batten |