Tender For Revenue Department- Plan Schemes- Basic Amenities In Village Offices (2019-20)- Kottappady Village Office- Additional Room
Tender Overview
Project Description
Revenue Department- Plan Schemes- Basic Amenities In Village Offices ( 2019-20 ) - Kottappady Village Office- Additional Room The Scope Of The Proposed Work Include Solid Block Masonry For Superstructure, Providing Aluminum Windows, Partition Works And Wooden Doors, Providing False Ceiling Works, Flooring Withvitrified Floor Tiles , Plastering And Painting Works Etc.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Engaging labour : Coolie |
| 3 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available sizeconfirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM1:6 ( 1 cement : 6 coarse sand) etc complete |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floorfive level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantilevers |
| 6 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | Providing and fixing in position factory made precast RCC M-40 fixing with hold fast embedded in 1:3:6concrete block for doors and windows frames having excellent smooth finish as per IS: 6523 withreinforcement of 3 Nos, 6 mm dia main bars tied with 3 mm M.S stirrups placed @ 200 mm C/C and 6numbers high strength polymer blocks of required size for fixing hinges including providing 6 no speciallydesigned M.S. galvanised sleeves for accomodating 6 mm dia fully threaded bolts for fixing hold fast onvertical members, providing suitable arrangement for recieving sliding door bolts and tower bolt etc allcomplete, as per the direction of Engineer in charge. The frame shall be measured in running metercorrect to two places of decimal. Window/Door frame 100 mmx 60 mm |
| 8 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ woodenframes with rawl plugs screws etc |
| 9 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mmhaving single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall bemoulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminateshall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall becovered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 10 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 11 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 12 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work |
| 13 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as permanufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.Onsteel work |
| 14 | Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters fordoors, windows and clerestory windows (Area of opening for panel inserts excluding portion insidegrooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40mm thick using good quality Anjili/ Jack wood |
| 15 | Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood) |
| 16 | Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand and manufacture, made with fire - retardant gradeunsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, withwooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing toframes. |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built upstandard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up thegaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium(minimum thickness of powder coating 50 micron) |
| 18 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and makingprovision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasketrequired (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDMrubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0mm thickness |
| 20 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded woodparticle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architecturaldrawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative laminationon one side and balancing lamination on other side |
| 21 | Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron)consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceilingincluding aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminiumperimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing theframe work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws allcomplete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjustinghangers, ceiling cleats and expansion hold fasteners to be paid for separately ). |
| 22 | Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approvedquality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall bepaid separately) |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the jointswith white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by themanufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), includingpointing the joints with white cement and matching pigment etc., complete. |
| 25 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to bespecified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm, including pointing in white cement mixed with pigment of matching shadecomplete |
| 26 | Electrical works |
| 27 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed steel conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductorsingle core cable etc as required.Group B |
| 28 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recessincluding making good the damages, colour washing etc as required (RoHS compliant )6 modulemoulded plastic box on surface |
| 29 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recessincluding making good the damages, colour washing etc as required (RoHS compliant )8 modulemoulded plastic box on surface |
| 30 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. asrequired.6 Module |
| 31 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. asrequired.8 Module |
| 32 | Wiring for power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable insurface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing as required. |
| 33 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combinedplug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of lightpoints |
| 34 | Supply conveyance, installation, testing and commissioning the 20W LED tubeset directly on wall andgiving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wireor extending the original wiring and giving connections as required etc. all complete. |
| 35 | Supply and fixing bulb holder LED bulb |
| 36 | Supply and fixing 9 W LED bulb |
| 37 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades working on 230/240V Single phase A/C |
| 38 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plateswitch box including connections but excluding modular plate etc. as required. |
| 39 | Stair |
| 40 | Engaging labour: Fitter |
| 41 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundationtrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides andramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplusexcavated soil as directed, within a lead of 50 m.All kinds of soil |
| 42 | Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 43 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floorfive level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 44 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform |
| 45 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 46 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 47 | Toilet Maintenance |
| 48 | Demolishing brick work manually / by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.Incement mortar |
| 49 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available sizeconfirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM1:6 ( 1 cement : 6 coarse sand) etc complete |
| 50 | Engaging labour : Carprnter 1st class |
| 51 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 52 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement primer |
| 53 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender