| 1 | Earth work in excavationof in all kinds of soil with initial lead and lift including dressing the sides & leveling the bed of the foundation to the required width & required depth including dewatering if necessary and stacking the excavated materials away from working area etc.complete and as per specification and direction of Engineer -in –charge. |
| 2 | Earth work excavation in foundation in Hard and compacted sheet rock within all leads and lifts including shoring, shuttering, propping bullahs, piling, dewatering from the foundation, supply & working of pumps stacking the excavated material away from the work in site. |
| 3 | Cement concrete (1:3:6) in foundation & plinth with 4cm. crusher broken granite metal of approved quality from approved quarry including hoisting lowering & laying in layers not exceeding 150mm. thick with proper packing & ramming each layer of concrete by means of vibrator ,providing groove & beads where necessary including curing, dewatering, shoring, shuttering if necessary at the time of laying concrete with cost, conveyance royality & taxes of all material required for the work including supplying & working pumps, T&P articles finishing the exposed surface smooth as per specific ation & direction of the Engineer-in Charge |
| 4 | Foundation |
| 5 | Up to Bed |
| 6 | Above Bed |
| 7 | Cement concrete with M-150+10% extra cement on nominal mix to be used for bottom plugging having maximum compressive strength of 150 kg./cm2 with minimum quantity of cement as specified in IRC code in work tests on 150 mm. cubes at 28 days curing using cement as per CL 710-7 of IRC-78/1983 after mixing & tests conduct in accordance with IS 456 & IS-516 with crusher broken hard granite coarse aggregate of 40 mm. size down graded in conformity with clause-302.6.2 of IRC-21/1987 of approved quality (test in laboratory) from approved quarry & concrete laid in continuous operation using tremie pipes or skip boxes upto required depthincluding lowering, hoisting & laying in layers of 150 mm. thick with cost, conveyance royalty & other taxes of all materials, labour hire charges of all T&P & machineriesrequired for the work complete in all respect. (in case of grouted concrete the grout mix shall not be leaner than 1:2) (Recuperation test may haveto be done if directed by Engineer-in-Charge). |
| 8 | (i) Bottom plugging |
| 9 | Cement concrete of M-150 having maximum compressive strength of 150 kg./cm2 ( test to be conducted) on 150 mm. cubes testedat 28 days including curing (tests conducted in accordance with IS-456 & IS-516) & conforming to clause-302 of IRC 21/1987 using clean crusher broken hard granite coarse aggregate of 40 mm. size down grade of approved quality to be protested in the laboratory) obtained from approved quarry the proportion mix, grading conforming to relevant ISI/IRC codes pre-approved including arranging of reinforcement as per approved drawing including hoisting, lowering concrete in layers not exceeding 150 mm. thick each compacting with vibrator watering & curing for 28 days centering shuttering & finishing the exposed surface smooth providing grooves & beads where necessary including cost, conveyance royality & taxesof all labour machineries etc. required for the work complete in all respects including dismantling the centering & shuttering as per specification & direction of Engineer-in-Charge. |
| 10 | (i) Top plugging |
| 11 | RCC of design mix of M-250grade having specified characteristics compressive strength/ target mean strength of 250kg./cm2 in design mix with minimum quantity of cement as specified in IRC Code of 150 mm. cubes at 28 days curing after mixing & tests conducted in accordance with relevant clauses of IS 456/IS 516/IRC 216/1987/IRC-78/1983 using crusher broken hard granite course aggregate of 20mm. down graded.sizes & proportion as specified in clause-302.6.2 of IRC 21/1987 & IS-10262 & subject to mix design in conformity with the grading & proportion of different materials for concrete as specified in the relevant codes of approved quality, obtained from approved quarry & using minimum quantity of cement confirming to codal provision including hoisting, lowering & laying concrete in layers not exceeding 15cm thick compacting with vibrators watering & curing for 28 days including water tightsteel centering , shuttering |
| 12 | & form works finishing the exposed surface smooth providing beads & grooves wherever necessary including cost, conveyance royalties and all other taxes of all materials with all leads & lifts, cost of all labour T&P & machineries etc. required for the work including dewatering if necessary, complete in all respects as per direction of the Engineer-in-Charge but excluding cost, conveyance of tor steel & binding wire & labour charges for straightening, cutting, bending, binding welding & tying the grills lapping spacing etc. where ever necessary & hoisting & placing in position ( to be paid separately as required for RCC works) |
| 13 | RCC railing |
| 14 | RCC of design mix of M-300grade having specified characteristics compressive strength/ target mean strength of 300kg./cm2 in design mix with minimum quantity of cement as specified in IRC Code of 150 mm. cubes at 28 days curing after mixing & tests conducted in accordance with relevant clauses of IS 456/IS 516/IRC 216/1987/IRC-78/1983 using crusher broken hard granite course aggregate of20mm. down graded sizes & proportion as specified in clause-302.6.2 of IRC 21/1987 & IS-10262 & subject to mix design in conformity with the grading & proportion of different materials for concrete as specified in the relevant codes of approved quality, obtained from approved quarry & using minimum quantity of cement confirming to codal provision including hoisting, lowering & laying concrete in layers not exceeding 15cm thick compacting with vibrators watering & curing for 28 days including water tightsteel centering , shuttering |
| 15 | & form works finishing the exposed surface smooth providing beads & grooves wherever necessary including cost, conveyance royalties and all other taxes of all materials with all leads & lifts, cost of all labour T&P & machineries etc. required for the work including dewatering if necessary, complete in all respects as per direction of the Engineer-in-Charge but excluding cost, conveyance of tor steel & binding wire & labour charges for straightening, cutting, bending, binding welding & tying the grills lapping spacing etc. where ever necessary & hoisting & placing in position ( to be paid separately as required for RCC works) |
| 16 | Foundation |
| 17 | Abutment & Pier Shaft |
| 18 | Retaing Wall / Wing Wall |
| 19 | Abutment & pier cap |
| 20 | Dirt wall |
| 21 | Superstructure |
| 22 | Wearing Coat |
| 23 | Approach Slab |
| 24 | Providing HYSD bars confirming to approved gradeF-415 including all labours for cutting ,bending, binding, lapping, splicing, welding etc. (conforming to ISI specification) & jointing if necessary by lapping & tying the grills & placing in position as required for RCC works as per the approved design, hoisting, lowering & laying position including cost & conveyance of tor steel & binding wires of 18 to 20 gauge(as to be approved by the Deptt.) etc. complete with Cess in all respect (weight of binding wire shall not be considered for payment at all which will be borne by the contractor) as per specification and direction of the Engineer in charge. |
| 25 | Supplying, fitting, fixing in position Neoprene bearing of approved design & specification at the designed level including fixing with resin of required grade & strength/ holding down bolts of standard specification including cost conveyance taxes of all materials with cost of all labour T&P & other machineries required for the work complete in respects as per direction of the Engineer-in-Charge. The bearing should confirm to the latest MOST specification & IRC codes & should be tested before use( test certificate to be furnished) |
| 26 | Providing fitting & fixing expansion joints with M.S. Angles 75mm. X 75 mm. X 6 mm. at the edges of the slab with suitable anchoring arrangements by 12mm. M.S. Bars as per MOST design & drawing including fitting, fixing & welding with 6 mm. plates & filling joints of wearing coat with bitumen joint filler 12 mm. thick & joint sealing compound at top including painting of exposed surface of M.S. covered plates with anticorrosive bitumanstic paint etc. with cost, conveyance taxes of all materials labour & T&P etc. complete in all respects as per specification & direction of the Engineer-in-Charge. |
| 27 | Providing C.I. grating to holes in deck slabs size upto 15 cm dia for drainage of water including cost of materials & T&P required for the work as directed by the Engineer-in-Charge. |
| 28 | Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescense and applying paint @ 1 litre per 02 Sqm etc complete as per derection of Engineer-in-charge. |
| 29 | Back filling behind abutment, wing wall & return wall with granular material including all cost, carriage, royality & labour as per specification & direction of the Engineer-in-Charge. |
| 30 | Granular Material |
| 31 | Sandy Material |
| 32 | Providing weep holes in the abutment & wing walls 8.00cm. X 23.00cm. size including metal spall backing 30cm X 30cm. size in rear complete as per the approved design & drawing including providing centering & shuttering with cost, conveyance, royality & taxes of all materials T&P articles etc. complete in all respects as per specification & direction of the Engineer-in-Charge. |
| 33 | Providing 600mm thick filter media in the rear of abutment and wing walls with 5cm size and down graded hand broken granite metal of approved quality from approved quarry as per specification and direction of the Engineer-in-charge including cost, conveyance royalty and taxes of all materials T&P articles required for the work etc. complete. |
| 34 | Providing Rough stone dry packing / pitching in slope, protection walls, approns and revetments to designed thickness usinghard granite stones of required size of approved quality from approved quarryincluding quarrying supplying conveying and cost conveyance taxes royalty of all materials including T&P complete including filling the interstices with small stones by wedging and hammering finished to proper slope and level as per direction of the Engineer – in – charge including dewatering if required. |
| 35 | Supplying and fixing of RCC Guard post of 150 mm dia and IM long in RCC (1:2:4) using 20mm down graded size h.g chips including all labours, materials ,carriage ,royality & taxes of etc. complete. |
| 36 | Fixing anchor bars upto 28mm. dia to the founding level at rock strata as per approved design including cost, conveyance & all taxes of all materials and T&P required for the work but excluding cost of TS rod & labour charges for bending, binding, tying the grills & placing in position as per specification & direction of Engineer-in-Charge. |
| 37 | Without G.I.Pipe |
| 38 | Earthwork in Hard soil within 50m, initial lead , 1.50m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer in charge. |
| 39 | Construction of embankment with approved material obtained from borrow pits with all liifts and leads, transporting to the site by mechanical means within a lead of 05kms, spreading, grading to required slope and compacting to meet requirement of table 300-2 & clause 305 of MoSRT&H specifications for Road & Bridge works (04th Revision) |
| 40 | Loosening of the ground uptoa level of 500 mm below the sub grade level, watered, graded and compacted in layers to meet requirements of table 300 - 2 for sub grade construction & clause 305 of MoSRT&H specifications for road & bridge works(4th revision). |
| 41 | Construction of Granular Sub Base by providing well graded material, spreading in uniform layers with motor graded on prepared surface , mixing by mix-in-place method at OMC and compacting with smooth wheel roller to achieve the desired density etc complete as per MORD Technical Specification Clause 401 as per direction of Engineer-in-charge. |
| 42 | Providinglaying spreading and compacting stone aggregatesof specificsize to W.B.M. specificationincluding spreading in uniform thickness , hand packing rolling with 8-10ton roller applying andbrooming requisite type of screening /binding materials to fillup the interstices watering including cost carriage royalty etc. complete. |
| 43 | IRC Grade II Material |
| 44 | IRC Grade III Material |
| 45 | Providing and applying Primer coat with bitumen emulsion on prepared surface ofgranular base including clearing of road surfaces and spraying primer @ 0.60kg/ sqm using Mechanical means as per clause 502 of MoSRT&H Specifications of Road & Bridge work (04th Revision) |
| 46 | Providing and applying Tack coat with bitumen emulsion on prepared surfaceincluding clearing of road surfaces and spraying primer @ 0.20kg/ sqm using Mechanical means as per clause 502 of MoSRT&H Specifications of Road & Bridge work (04th Revision) |
| 47 | Collecting, Supplying and laying of 20 mm thick Pre Mix Carpet including Labourusing 0.27cum of 13.2mm to 5.6mm size crushed stone chipping and 14.60kg.penetration grade of bitumen for 10sqm including hand packing to proper camber and consolidation with PRR inclusive of hire and running charges of PRR , bitumen mixtures, tar boilers and all other T & P articles etc. complete as per specification and direction of the Engineer-in-charge. |
| 48 | Labour for laying 6mm thick Precoated Seal coat type B using 0.06cum of 06 mm size and down graded as per sieve analysis and 6.80kg of bitumen per 10sqm and applying tack coat 2kg of bitumen for 10sqm including hire and running charges of P.R.R. Hot mix plant tar boiler, cost, carriage and royalty etc. complete as per direction of the Engineer in Charge. |
| 49 | Providing filling manually with selectedsandin layers not exceeding150mmthick includingwatering and compactingwith all leads and liftsincludingcost , carriage royalty etc. |
| 50 | Providing laying R.C.C. Hume pipe NP3 class for culverts including fixing collar with cement mortar 1:2 but excluding excavation, protection work, backfilling,concrete and masonry work in head walls and parapets clause 1106 of MORD specification for Rural roads and as per irection of Engineer-in charge. |
| 51 | 1000 mm dia Single row |
| 52 | BSY Sign Board |