Tender For Repair/Maintenance Of Dg Sets Of Various Capacities, Amf Panels And Other Allied Works At Pump Houses Of Water Supply System In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Dg Sets Of Various Capacities, Amf Panels And Other Allied Works At Pump Houses Of Water Supply System In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow. Submission Date for this Tender is 07-03-2023. Diesel Generators Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36308951
Corrigendum : Tender For Repair/Maintenance Of Dg Sets Of Various Capacities, Amf Panels And Other Allied Works At Pump Houses Of Water Supply System In The Area Of Age E/M Ext (Ws) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
07-03-2023

Tender Details

Tender For Repair / Maintenance Of Dg Sets Of Various Capacities, Amf Panels And Other Allied Works At Pump Houses Of Water Supply System In The Area Of Age E / M Ext ( Ws ) Under Ge E / M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Mar-2023 Corrigendum1 Financial Bid 07-03-2023
2 01-Mar-2023 Corrigendum1 BOQ 07-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF DG SETS OF VARIOUS CAPACITIES, AMF PANELS AND OTHER ALLIED WORKS AT PUMP HOUSES OF WATER SUPPLY SYSTEM IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Taking down and dismantling the spares/ components from engine assy of capacity from 30 KVA to 82.5 KVA Diesel Engine segregating serviceable and semi serviceable and decarbonisation, cleaning of interior& exterior all parts by disconnecting the out going connection from diesel engine from the panel board & re-assebling the same after repair/ replacement of defective spares complete all as specified and directed.(Note :- Spares/components shall be measured & paid separately under relevent items)
2Spares for DG Set replacement capacity 30 KVA to 50 KVA complete all as specified and directed (a) Fuel filter ( Primary & Secondary)
3(b) Oil Filter
4(c) Air Cleaner
5(d) By pass filter
6(e) Super bypass filter
7(f)Hose pipe set
8(g) Fan belt suitable Make :- Kirloskar/ Cummins
9(h)Banjo bolt off sizes
10(j) Screen filter
11(k)Fuel Injector pipe
12(l) Injector nozzles
13(m) Injector plunger and plunger spring
14(n)Inlet and Exhaust valve
15(o) Tappet bush with packing
16(p) Valve guide and spring
17(q) Piston rings
18(r) Alternator booster panel and control unit with all asseceries
19Spares for DG Set replacement Cap above 50 KVA to 82.5 KVA complete all as specified and directed (a) Fuel filter ( Primary & Secondary)
20(b) Oil Filter
21(c) Air Cleaner
22(d) By pass filter
23(e) Super bypass filter
24(f)Hose pipe set Make :- Kirloskar
25(g) Fan belt suitable Make :- Kirloskar/ Cummins
26(h)Banjo bolt off sizes
27(j)Screen filter
28(k)Fuel Injector pipe
29(l)Injector nozzles
30(m) Injector plunger and plunger spring
31(n)Inlet and Exhaust valve
32(o) Tappet bush with packing
33(p) Valve guide and spring
34(q) Piston rings
35(r) Alternator booster panel and control unit with all asseceries forabove 50 KVA to 82.5 KVA alternator
36M&L for Taking out FIP from DG set of 30 KVA to 50 KVA transporting to service center/contractor workshop for over hauling/calibration and refixing on DG Set after replacement of worn out parts such as screen filter, delivery valves, plunger, O-ring spring rotor assembly injector element etc complete all as specified and directed.
37All as per item No 36 above but 50 KVA upto 82.5 KVA
38Taking out of turbo charger from DG Set for capacity 30 KVA TO 50 KVA transportation to work shop for repairing and replacement of turbo charger kit & refixing to DG Set and testing complete all as specified and directed.
39All as per item No 38 above but 50 KVA upto 82.5 KVA
40S&F in replacement alternator (Dynamo) charger suitable for 12 Volt Battery with all accessories i.e. fabrication of mounting brackets nut bolt etc suitable for DG set of capacity 30 KVA to 82.5 KVA including testing complete all as specified and directed. Make : TVS / LUCAS or equivalent as per existing make
41M&L for supply & replacement lead acid battery 12 volt 150 AH 25 plate including initial charging at various DG sets complete all as specified and directed.
42M&L for supply & replacement lead acid battery 12 volt 100 AH 25 plate including initial charging at various DG sets complete all as specified and directed.
43M&L for draining out old used lube oil from engine sump, cleaning of sump and supply & filling new lubricating oil SAE grade (15 w 30) multiviscoscity complete all as specified and directed.
44M&L for draining out old used lub oil from engine sump, cleaning of sump and supply & filling new lubricating oil SAE grade (20 w 40) multiviscoscity complete all as specified and directed.
45Supply and top up coolant/replacement of coolant by new coolant suitable for ambient temp from 15 to 40 degree centigrade complete all as specified and directed.
46Supply & pouring distilled water superior grade all as approved complete all as specified and directed.
47S&F turbo charger with all accessories suitable for DG set of 30 KVA TO 50 KVA Make-kirloskar/ cummins or others complete all as specified and directed.
48All as per item No 47 above but 50 KVA upto 82.5 KVA
49M&L for dismantling and transporting to contractor"s work shop of alternator by opening of nut bolts of base plate and coupling opening of front and rear cover removing of fan and removing of armature, rewinding of alternator by super enameled insulated copper wire as per existing gauge,insulating materials, varnishing, drying in hot oven up to desired temperature assembling and testing on connected load of capacity 30 KVA TO 50 KVAcomplete all as specified and directed. Note : (Cost of transportation is deemed to be included in quoted rates)
50All as per item No 49 above but 50 KVA upto 82.5 KVA
51Material & labour for preparation of old painted surfaces by removing of dust and dirt by caustic soda or any other means, painting of DG set CAP 30 KVA to 82.5KVAof various capacity complete Canopyas per colour code by spray painting applied two coat of synthetic enamel paintover existing painted surface and marking of SM/MES No on the sets as per approved colour complete all as specified and directed.
52M&L for dismantling of UNSV and Supply & replacement with new self starter 12 volt, complete all as specified and directed.
53M&L for taking outof burnt out AVR system ofDG setby opening of connection chamber of alternator dismantling all existing electric/electronic connection replacement of AVR set reconnection checking of all circuit, testing the same up to the satisfaction of cap 30 KVA To 82.5KVA, complete all as specified and directed.
54M&L for taking down unserviceable self starter 12 volt from DG Set transporting to contractor workshop dismantling pinion etc, rewinding of armature and field coil by suitable size of insulated copper wire, to achieve its original performance, varnishing, replacement of pinion, pinion spring, carbon brush etc reassembling the same, testing and refitted with DG Set and testing complete all as specified and directed.
55Supply and fixing in replacement of solenoids switch for auto on off manual mode in the engine operation including wiring complete all as specified and directed.
56M&L for dismantling of water pump assembly from the the DG sets and supply and fixed new water pump assembly for the DG sets of capacity 50/60/62.5/ 63/82.5 kVA including testing complete all as specified and directed.
57Supply & fix battery terminal heavy duty made out of brass suitable for 12 volts lead acid battery complete all as specified and directed.
58M&L for replacement of horness cable control wiring and testing complete all as specified and directed.
59S&F off load change over switch cap 100 Amps 4 pole 415 Volts by addition/alteration in existing wall complete all as specified and directed.
60S&F off load change over switch cap 160 Amps 4 pole 415 Volts by addition/alteration in existing wall complete all as specified and directed.
61Supply & fix in repairs electronic control timer type ET-100 of suitable capacity as required at site, complete all as specified and directed. Make:- L&T/ABB/ Legrand/ AE/Secure.
62Supply & fix in reapirs engine starter relay of suitable capacity as required at site, complete all as specified and directed.Make:- L&T/ABB/ Legrand/ AE/Secure.
63Supply & fix outdoor type fountain light waterproof and RGB colour with 6 bulb, 18 watt LED,12 volt, IP68 with fitting accessories complete all as specified and directed.
64Supply & fix in repairs under voltage relay, complete all as specified and directed.(Make:- PIC / EC / Wader.)
65Supply & fix in repair four Pole Power Contractor -TypeMCX-22, 100 Amps, 415V, 50 Hz, complete all as specified and directed.Make-L&T
66Supply & fix in repair three Pole Power Contractor -Type,MNX-110, 120 Amps, 415V, 50 Hz, complete all as specified and directed.Make-L&T
67Supply & fix in repair three Pole Power Contractor -Type MNX-140, 160 Amps, 415V, 50 Hz, complete all as specified and directed.Make-L&T
68Supply & fix in repair four Pole Power Contractor -Type ML-06 100 Amps, 415V, 50 Hz, complete all as specified and directed.Make-L&T
69Supply & fix in repair Single Phase Preventor Relay + Timer 415 Volt, complete all as specified and directed.Make : L& T/ Minilac/ C&S
70Supply & fix in repair MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA, complete all as specified and directed.
71Supply & fix MCCB 100 Amp, 3 Pole, 415 V with breaking capacity 16 KA, complete all as specified and directed.
72Supply & fix MCCB 125 Amp, 3 Pole, 415 V with breaking capacity 36 KA, complete all as specified and directed.
73Supply & fix in repairMCB SPN capacity 32 amp, "C" series , complete all as specified and directed.
74S&F Flourescent LED tube light fitting Surface mounting , 1X36 Watt ,energy efficient,ceiling /wall mounting box type fitting complete , with decorative serrated acrylic cover diffused illumination elegantlydesigned , spring loaded, rotary type lamp holder, connector block etc. and all accessories with 1 No 40/36 watt tube rod including provn of two core flexible copper cable of size 1.5 Sqmm from ceiling rose/connector in and ilcuding taking out old unservicable light , complete all as specified and directed.
75Supply & Fixing LED street/bldg light fitting luminaire 70 Watt IP65, 230 volts, new generation energy saving & enviormental friendly long life versatile pressure die cast aluminium roadway luminarie with high power LEDs as light source and electronic driver alongwith suitable bracket required as per site for fixing the lightcomplete all as specified and directed.
76Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections, complete all as specified and directed.
77Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed.
78Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed.
79Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed.
80Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed.
81M&L for brick work with fly ash bricks as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, including taking down complete all as specified and directed.
82Daily Maintenance of AMF Panels of any make and model ofD.G.Sets atvarious locations in Lucknow Cantt area by depolying one trademan including cleaning overhauling and repairs to defective AMF Panelsafter renewal of defective spares / components of any approved make as per existingor its equivalentcomplete all as specified and directed. [Note :(i) Each AMF Panel shall be cleaned /maintained daily under supervision of EIC (ii) Fixing of defective spares / Components are deemed to be included in the unit rate but cost of spares / components will be paid against items Ser No 23, 24, 26 to 30, 33 and 34 here-in-after (iii) Daily maintenance register shall be maintained for each pump house and shall be signed by representative of contractor and the Engineer in-Charge after doing necessary maintenance)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail