Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone B And C Of Af Stn Agra Under Ge Af Tech Area Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone B And C Of Af Stn Agra Under Ge Af Tech Area Agra. Submission Date for this Tender is 08-03-2023. Diesel Generators Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36306929
Corrigendum : Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone B And C Of Af Stn Agra Under Ge Af Tech Area Agra
Open Tender
Indian
Uttar Pradesh
agra
08-03-2023

Tender Details

Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone B And C Of Af Stn Agra Under Ge Af Tech Area Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Feb-2023 Corrigendum1 BOQ 08-03-2023
2 03-Mar-2023 Corrigendum2 Other 08-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work: REPAIR & MAINTENANCE OF DG SET ANDAMF PANEL FOR STAND BY DG SET IN ZONE "B" & "C"OF AF STN AGRAUNDER GE (AF) TECH AREA, AGRA.
Sl. No. Item Description
1M&L for servicingofupto40KVA DG set including replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oilcomplete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule "A". (b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
2M&L for servicing50 KVA to 82.5 KVADG setincluding replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oilcomplete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop ofmanufactured company or his authorised representative.
3M&L for servicing of 100to180 KVA DG setincluding replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop ofmanufactured company or his authorised representative.
4M&L for servicing of200to320 KVAKVA DG set including replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
5M&L for servicing of400KVA DG setincluding replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil cleaning of fuel tank by taking out the existing fuel in container and keeping aside and refilling the same after cleaning the fuel tank complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
6M&L for servicing of 500 KVAKVA DG setincluding replacement Engine oil and all type offilters as per manufacturers manual.Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil cleaning of fuel tank by taking out the existing fuel in container and keeping aside and refilling the same after cleaning the fuel tank complete all as specified and directed.(Note:- (a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
7Supply and filling ofEngine oil15 W / 40 complete all as specified and directed. Make :Castrol / HP /Bharat Petrolium / Valvoline
8Supplyand filling of coolant suitable forradiater of DG sets complete all as specified and directed.Make: HP/TVS / Valvoline / KIRLOSKAR
9S&F in renewal battery terminal brass(heavy duty)with nuts & bolts (as per sample) complete all as specified and directed.
10Supply and filling distilled water suitable for DG set complete all as specified and directed.
11Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion , rewinding of armature , bushes set , rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter for capacity upto 125 KVA DG Set Complete all as specified and directed.
12Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion, rewinding of armature, bushes set,rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter of DG set for capacity from 321-400 KVA Complete all as specified and directed.
13Disconnecting of self starter 24 volts DC, dismantling and repairing with renewal of bendex pinion,rewinding of armature,bushes set, rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter DG set for capacity from 200 to 320 KVA Complete all as specified and directed.
14Disconnecting of self starter 24 voltsDC, dismantling and repairing with renewal of bendex pinion,rewinding of armature,bushes set, rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter DG set for capacity from 401 to 500 KVA Complete all as specified and directed.
15Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator, loading transportation and unloadingincluding refixing to its old position with proper accuracy and correct situationforDG set Capacity up to 200 KVAincluding renewalof GI/MS nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
16Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator loading, transportation andunloading including refixing to its old position with proper accuracy and correct situationforDG set Capacity up to 100 KVA including renewal ofMS/GInut/bolt, hose pipe sets with MS/GI clamps and testing complete all as specified and directed.
17Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator unloading and transportation and unloading& including refixing to its old position with proper accuracy and correct situationforDG set Capacity from 200 KVA to 320 KVA including renewal of MS/GInut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
18Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading and transportation& unloading including refixing to its old position with proper accuracy and correct situationfor DG set capacity from 400 KVA to 500 KVA including renewal of MS/GI nut/bolt, hose pipe sets with MS/GI clamps and testing complete all as specified and directed.
19Taking down old Radiator by opening nut/bolt from foundation and supply, installing and testing new Radiator with proper accuracy and correct situationfor DG sets capacity from upto 200 KVA including MS/GI nut/bolt, hose pipe sets with MS/GI clamps and testing complete all as specified and directed.
20M & L for disconnection & taking down of Afte rcooler assembly from foundation ofDG set engine including repairing, soldering & cleaning of Radiator assembly completeby acid process and refixing to its old position with proper accuracy and correct situation including transportation charges for DG set of capacity 200 to 320 KVA complete all as specified and directed.
21M & L for disconnection, taking down and repairing of alternator DC from DG set engine with rewinding of armature ,renewal of carbon brushes, renewal of bearings, rewinding of field coil assembly, renewal of connection plate,reassembling and refixing to DG set engine after necessary repair for following sizes complete all as specified and directed:-
2212 Volt
2324 Volt
24M & L for repairing of automatic battery charger of12 Volt / 24 Volts including rewinding of transformer unit and renewal ofdiode plates, rectifier plates,auto cut mosfet circuit , fuses etc. and testing for following sizes complete all as specified and directed:-
2512 Volt
2624 Volt
27M & L for repairing of canopy doors complete with renewal of following itmes including denting and necessary welding of doors complete all as specified and directed:-
28Stain less SteelDoor lockof size 5.75" x 4.5" and of 08 levers
29Stain less Steel.door handle of 150mm size
30Stain less SteelButt hinges of 100 mm size heavy duty of having 08 holes for screwing all asmspecified
31M & L for flywheel ringin renewal with proper setting and alignmentfor 100 to 160KVA DG set complete all as specified and directed.
32M & L for painting of DG set, panels, diesel tank, silencerby applying two coats of synthetic enamel paint overone coat of primer and writing SM.MES No, Make and capacitywith super enamel paint including scrapping of old paint for DG setCapacity from 100 KVA to 160 KVAcomplete all as specified and directed.
33M & L for painting ofDG set of capacity 20 KVA & 30 KVA DG Set withtrolly frame including panels, diesel tank by applying two coats of super sythentic enamel paint over one coat of primer complete all as specified and directed.
34M & L for renewal of Magnetic Pickup suitable for 100 KVA & 200 KVA DG set complete all as specified and directed. Make:- Cummins/ KIRLOSKAR / GREAVES COTTON
35S&F in renewalShut down valve solenoidsuitable for all capacities of DG set complete all as specified and directed.
36S&F in renewal Thermostatof suitable for water temprature reading and engine temperature reading fitting with existing network along with minor modifications of existing system for any capacities of DG set complete all as specified and directed.
37S&F in renewalHose Sil D100 X 90for DG setupto 200 KVAcapacity complete all as specified and directed.
38S&F in renewal Switch temperature (Water Safety) suitable for all capacities ofDG set complete all as specified and directed.
39S&F in renewalSeparator fuel and watersuitable for all capacities of DG set complete all as specified and directed.
40S&F in renewalAir Cleaner Assemblyfor DG set upto62.5KVA capacity complete all as specified and directed.
41S&F in renewalcopper Battery leadof 25 Sqmm, 2mtr longsuitable for all capacities of DG set complete all as specified and directed.
42S&F in renewal Feed pumpsuitable for all capacities of DG set complete all as specified and directed.
43S&F in renewalV Belt / Fan beltsuitable for all capacities of DG set complete all as specified and directed.
44S&F in renewalFuel pipe (525 mm) for all capacities of DG set complete all as specified and directed.
45M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set of capacity15 KVA to 82.5 KVAincluding overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
46Supply & fix in renewal Nozzle for15 KVA to 82.5 KVA capacityDG set complete all as specified and directed.
47Supply & fix in renewal F.I.P. Elements for 15 KVA to 82.5KVA capacityDG set complete all as specified and directed.
48M&L fordisconnecting, dismantling and overhauling of fuel injector pump of DG set of capacity 100 KVA to 200 KVA including repair, overhauling, calibration, testing complete and refixing to its original position properly complete all as specified and directed. Note:- FIP shall be calibrated by authorised work shop of manufacturer company Contractor has to submit documentary evidense for over hauling carried out from authorised work shop.
49Supply & fix in renewalNozzle & Holder Assembly of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
50Supply & fix in renewalGasket injection pump mount of DG Set of capacity 100 KVA to 200 KVA complete all as specified and directed.
51Supply & fix in renewal of A.V.R suitable for20 KVA to 200 KVAcapacity of DG set complete all as specified and directed. Make:-KIRLOSKAR/ AE / NATIONAL.
52M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection and supply and fixing ofnew water pump assembly suitable for DG set capacity for 40 KVA to 200 KVAincluding renewal of u/s hose pipes, fan belt, nut/bolts etc complete all as specified and directed.Make:-- KIRLOSKAR/ Cummins / GREAVES COTTON
53Supply & fix in renewal fully automatic battery charger (input 230V AC SMPS based and out put 24V DC) for 24 voltbattery complete all as specified and directed. Make :-KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA .
54Supply & fix in renewal fully automatic battery charger (input 230V ACSMPS based and out put 12V DC) for 12 voltbattery complete all as specified and directed. Make :-KIRLOSKAR / ELECT INDIA / Cummins /UNITEK INDIA
55Supply & fix in renewalBattery- 12 Volts,180 AHfor DG set of suitable capacity complete all as specified and directed with 18 month replacement warrantty Make: EXIDE / AMARON / or equillvant as approved.
56Supply & fix in renewalBattery- 12 Volts,120 AHfor DG set complete all as specified and directed with 18 month replacement warranty.Make: EXIDE / AMARON as approved
57Supply & fix in renewalBattery- 12 Volts,100 AHfor DG set complete all as specified and directed with 18 month replacement warranty.Make: EXIDE / AMARON as approved.
58M&L for checking of AMF panel & DG set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repair as per site requirement and checking of AMF panel andDG set for power suply from DG set through AMF panel and replacethe worn out parts of AMF panel & DG setbyexpert engineer complete all as specified and directed.Notes :- Note:(a) Replaced worn out parts of AMF panel/DG set shall be measured and paid separately under relevant items of schedule "A".(b) Charges for detectingthe fault in AMF Panel/electric system/DG set are included in the quoted item rate.
59M & L forflywheel ring ( 3246713 ) in renewal with proper setting and alignment for the DG set capacity 400 to 500 KVAcomplete all as specified and directed.
60M & Ltaking down old Flywheel ring from DG set and provideng of new flywheel ring ( 3166605 ) with proper setting and alignment for the DG set of capacity 320 KVA DG set complete all as specified and directed.
61M & L fordisconnecting, dismantling and overhaulingwith repairing of PT pump complete including renewal of drive accessories, Plunger Air fuel control, Oil seal , Gasket set fuel pump etc including machinery work for500 KVA capacityDG SET complete all as specified and directed (Location 50 Sqn). Note:- PT pump shall be calibrated by authorised work shop of manufacturer company Contractor has to submit documentary evidense for the repairing carried out from the authorised work shop
62M & L for shifting of trolly mounted DG set capacity up to 250 KVA fromlocation to another location (with in 05 kilometer) complete includingdisconnection of cable, earth strip including transportation with using necessary chain pulley & HYDRAULIC jack etc including reconnection of cableand earth strip and other etc. at new location complete all as specified and directed.
63S & F in renewal Genset Controller Panel suitable upto 125 KVA capacity DG Set, make and model of Genset controller panel shall beas per site or directed by Enginer -in- charge
64S & F in renewalGenset Controller Panel suitable DG Set of capacity 126 to 320 KVA capacity DG set make and model Genset controller panel shall be as per site or directed by Enginer -in- charge
65S & F in renewal Genset Controller Panel sutiable upto 400 KVA to 500 KVA make and model as per site or directed by Enginer -in- charge
66Supply & fixin replacementIndicater lamp with holder set of three colours ofR,Y & B (LED type) suitable for DC/AC supply.
67Supply & fix in replacementaluminum bus bar of suitable length,width & thickness with suitable size of porcelain insulator duly insulated with coloured insulation tape R,Y,B and neutral Black laminated with respective colour code fitted on existing LT panels with minor modifications by cuttung/welding al all as specified and directed.
68Supply & fix in replacement Relay-24 VDC/ 12 VDC / 220 VAC / 240 VACfor AMF panel of DG set. Make: CUMMINS( AX1012821 ) / OMRON / SALZER / PLA.
69Supply & fix in replacementContactor- 3/4 Pole,150 Amps/ 140 AMPSfor 62.5KVA capacityDG Set AMF panel withreplacement of lugs and checking of all connections etc.Make:- LEGRAND ( 4162 66) /L &T/ SCHNEIDER / C & S .
70Supply & fix in replacementContactor- 3/4 Pole, 225 Amp/ 200 Ampfor 125 KVA capacity DG set AMF panel with replacement of lugs and checking of allconnections etc.Make:- LEGRAND ( 4162 96 ) /L &T / SCHNEIDER / C & S .
71Supply & fix in replacementContactor4 Pole, 250 Ampsfor AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc. Make:-SCHNEIDER ( LC1F1504 ) /L &T / C & S .
72Supply & fixin replacementContactor of 4 Pole, 400 Amps, for AMF PANEL of DG Set with replacement of lugs and checking of all connections etc.Make:- SCHNEIDER ( LC1F3304 )/L &T / C & S .
73Supply & fix in replacementSpare Contact Kit for Contactor-250 Amps suitable capacity 100to 125 KVA capacity DG set.Make:- L & T ( CS94084) / SCHNEIDER / C & S .
74Supply & fix in replacementSpare Contact Kit for Contactor-400 Amps suitable 110to 200 KVA capacity DG set AMF panel. Make:- L & T ( CS94297 ) / SCHNEIDER / C & S
75Supply & fix in replacementSpare Contact Kit for Contactor-600 Amps suitable for 320 KVA capacity DG SET.Make:- L & T ( CS94299 ) / SCHNEIDER / C & S
76Supply & fix in replacementMCCB, 400 Amp, 4 pole, 36 KA ,thermal magnetic adjustable type from 80-110% of 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed. Make:-L & T ( CM94153OOOOAG ) / Legrand /HAVELLS .
77Supply & fix in replacement Microprocessor base MCCB of capacity630 Amp, 4 pole, 36 KA , 415 Voltincluding taking out existingconnections, cable lugs etc all as specified and directed. Make:- L & T ( CM94179OOOOAG ) / Legrand/ HAVELLS .
78Supply & fix in replacementMicro processor based type MCCB, 800 Amp current carrying capacity, 4 pole, 50 KA , 415 Voltincluding taking out existingconnections, cable lugs etc all as specified and directed. Make:- L & T( CM96115OOOOAG ) / Legrand / HAVELLLS
79Supply & fix in replacementDIN Type Fuse Links Type HN (160 amps ) suitable for 100 KVA capacity DG setAMF panel. Make: L & T ( SF94231 ) / STANDARDOREquivalent as approved
80Supply & fix in replacementDIN Type Fuse Links Type HN ( 100 amps ) suitable for 63KVA capacity DG setAMF panel. Make: L & T ( SF94129 ) / STANDARDOREquivalent as approved
81Supply & fix in replacementFuse Bases ( HN-Size 2 & 3 ) suitable for 63 KVA capacity DG setAMF panel.Make: L & T ( SK91051 ) / STANDARDOREquivalent as apprpved.
82Supply & fix in replacementSelector Switch four position.Make: Automation Electronics / SCIOREquivalent as apprpved
83Supply & fix in replacementSelf Engine Stop Relay Device for 63 KVA to 180 KVA capacity DG set AMF panel . Make:Automation Electronics / Elect India
84Supply & fix in replacementAMF Controller device for Auto/ Manual functionfor 200 KVA to 500 KVA capacity DG set. Make: Automation Electronics / ELECT INDIAOREquivalent as apprpved
85Supply & fix in replacementSolenoid stopper ( Solenoid Fuel Pump ) upto 125 KVA capacity DG set . Make:--Cummins ( 3928160 ) /Kirloskar /orEqivalent as apprpved
86M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection. Supply and fixing ofnew water pump assembly suitable for DG set capacity for 100 KVA to 200 KVAincluding replacement of u/s hose pipes, fan belt, nut/bolts etc complete all as specified and directed.Make:-- Kirloskar ( KL6.176.05.0.00 ) / Cummins orEqivalent as apprpved
87Supply & fix in replacement Electronic Timer, auxilary supply-240 VAC/24 VDC for 125 KVA to 200 KVA capacity DG set. Make: AE/ EAPL / MINILECt
88Supply & fix in replacementUndervolt/overvolt relay-ON/OFF delay time (1 to 15 sec ),sensing supply 415 Volt for 63to 400 KVA capacity DG set. Make-AE/PIC / MINILEC
89Supply & fixing new in replacementON-Load Changeover switch (Open Execution, Front operated) of 630 Amps, 4 Pole, 415 V, 50 Hz fitted in existing LT Panels with minor modifications by cutting/welding to fix the change over switch along with terminaton of LT cable with copper lugs of heavy duty ,including MS/GI nut bolts all as specified and dirceted. Make: HPL ( BP06304POAV ) /HAVELLS .
90Supply & fix in replacement ON-Load Changeover switch (Open Execution, Front operated) of 400 Amps, 4 Pole, 415 V, 50 Hz fitted in existing LT Panels with minor modifications by cutting/welding to fix the change over switch along with terminaton of LT cable with copper lugs of heavy duty , including MS/GInut bolts all as specified and dirceted. Make: HPL ( BP06304POAV ) /HAVELLS .
91Supply & fix in replacementON-Load Changeover switch (Open Execution, Front operated) of 250 Amps, 4 Pole, 415 V, 50 Hz fitted in existing LT Panels with minor modifications by cutting/welding to fix the change over switch along with terminaton of LT cable with copper lugs of heavy duty , including MS/GI nut boltsall as specified and dirceted. Make: HPL ( BP06304POAV ) /HAVELLS .
92Supply & fix in replacementON-Load Changeover switch (Open Execution, Front operated) of 125 Amps, 4 Pole, 415 V, 50 Hz fitted in existing LT Panels with minor modifications by cutting/welding to fix the change over switch along with terminaton of LT cable with copper lugs of heavy duty , including MS/GI nut bolts and all as specified and dirceted. Make: HPL ( BP06304POAV ) /HAVELLS .
93Supply & fix in replacementOFF-Load Changeover switch (Side Handle) of 400 Amps, 4 Pole, 415 V, 50 Hz. Make: HAVELLS/ HPL.
94Supply & fix in replacementRectifier Assembly for 40to 160 KVA capacity DG set.Make:KIRLOSKAR ( KV280108000) / CUMMINS OREquivalent as approved .
95Supply & fix in replacementThree Phase Multifunction Digital meter .Make: Automation Electronics / HPL / National
96Supply & fix in replacementAMF Relay Box for Auto/ Manual function including voltage monitor system and fully auto and manual system for 63to 110 KVA capacity DG set.Make: AE/ ELECT INDIAas approved.
97Supply & fix in replacementstarter (Self Starter)for 200 KVA capacity DG set. Make: KIRLOSKAR ( KL6.140.12.0.00 ) / AUTOLEK / LUCAS.
98Supply & fix in replacement Tube injector fuel supply for 100to 200 KVA capacity DG set. Make: CUMMINS ( 3964706 ) / KIRLOSKAR
99Supply & fix in replacement CONTROL GOVERNOR ( MECHANICAL GOVERNOR )for160 KVA capacity DG set. Make: CUMMINS ( 3037359 ). .
100M & L forrepairingPT pump complete with replacement of drive accessories, plunger and barrel, weight/courier,oil sheets etc including machinery work for 125to 160 KVA capacity DG set complete all as specified and directed. Note :- PT pump shall be calibrated by authorised workshop of manufacturer company Contractor has to submit documentary evidense for the repairing carried out from the authorised workshop.
101Supply & fixoil seal (3006738) for repairing of PT pump for 125 to 160 KVA capacity DG set complete all as specified and directed.
102Supply & fix gasket set fuel pump (3010242)for repairing of PT pump for 125to 160 KVA capacity DG set complete all as specified and directed.
103M & L for dismantlingturbo charger of DG set ofcapacity 100to 200 KVAincluding repair, overhauling, testing complete and fixing to its original position properly complete all as specified and directed.
104S&F in repair Kit Turbo (KIT3801101) for repairing of Turbo charger of DG set capacity 100 to 200 KVA complete all as specified and directed.
105S&F in repair shaft (01320360) for repairing of Turbo charger of the DG setcapacity 100 to 200 KVA complete all as specified and directed.
106M & L for dismantling andreplacement of Injector assembly (3239796) of DG set of capacity 62.5 to200 KVA complete all as specified and directed.
107Taking out alternator of DG Set of capacity 125to 200 KVA of any make, including material of labour for rewinding by using super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
108M&L for Field coil rewinding of alternator of 125to 200 KVA capacity DG sets of any make, including material andlabour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
109Taking out alternator of 62.5to 100 KVA capacity DG sets of any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
110M&L for field coil rewinding of alternator ofDG set of capacity 62.5to 100 KVAof any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
111Taking out alternator of DG set of capacity20 KVA to 50 KVA of any make including materials and labour for, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
112M&L for field coil rewinding of alternator ofDG set of capacity 20 to 50 KVAof any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and reconnecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
113S&F MCCB 4 Pole Thermal adjustable breaker type of following capacity complete all as specified and directed.
11463 AMP, 36 KA
115125 AMP, 36 KA
116160 AMP, 36 KA
117250 AMP, 36 KA
118Supply, fabricating and testing of factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 125KVA capacity DG Set, fabricated by using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No.(ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No.
119(iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load.(vi) Transformer of adequate rating. (vii) Ractifiers (viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacityand 2 Nos,MCCB 4 pole, 100 Amp, 25 KA, 4 pole thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
120Supply, fabricating and testing of factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 62.5KVA capacity DG Set, fabricated by using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No.(ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No.
121(iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load.(vi) Transformer of adequate rating. (vii) Ractifiers (viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacityand 2 Nos,MCCB 4 pole, 100 Amp, 25 KA, 4 pole thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
122Supply and Layingand testing ofXLPE insulated PVC and sheathed LTUG cable , beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 120 Sqmm 3.5 core IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles including taking down of old XLPE cablecomplete all as specified and directed.
123Supply and Layingand testingXLPE PVC insulated and sheathed LTUG cable, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 95 Sqmm 3.5 core IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles complete all as specified and directed.
124Supply and Layingand testing of XLPE PVCinsulated and sheathed LTUG cable, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 150 Sqmm 3.5 core IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles complete all as specified and directed.
125Excavation in trenches in soft/loose soil n. exc 1.5 m wide and n. exc. 1.5 m in depth for laying cables etc complete all as specified and directed.
126Return filling in and including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft /loose soil after cable are laid and tested complete all as specified and directed.
127Removing excavated surplus soil to a distance n. exc. 50m and deposited where directed at a level n. exc.1.5m above the starting point complete all as specified and directed.
128M&L for sand filing with clean dry fine river sand unsashed including gently punning around cables in trenches for cable protection complete all specified and directed. Note : punned thickness sahll be measused and paid.
129Supply & Laying sub class "B" briks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail