Tender For Construction Of Dual Gate (Vehicle Gate), Security Guard Room Along With Morcha At C.A. Porbandar. Sh- Provision Of Tyre Killers, Boom Barrier, Bollard And Electrification Works At C.A. Porbandar, porbandar-Gujarat

Airports Authority Of India has published Tender For Construction Of Dual Gate (Vehicle Gate), Security Guard Room Along With Morcha At C.A. Porbandar. Sh- Provision Of Tyre Killers, Boom Barrier, Bollard And Electrification Works At C.A. Porbandar. Submission Date for this Tender is 11-03-2023. Electrical Maintenance Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

36297847
Tender For Construction Of Dual Gate (Vehicle Gate), Security Guard Room Along With Morcha At C.A. Porbandar. Sh- Provision Of Tyre Killers, Boom Barrier, Bollard And Electrification Works At C.A. Porbandar
Open Tender
Indian
Gujarat
porbandar
11-03-2023

Tender Details

Construction Of Dual Gate ( Vehicle Gate ) , Security Guard Room Along With Morcha At C.A. Porbandar. Sh- Provision Of Tyre Killers, Boom Barrier, Bollard And Electrification Works At C.A. Porbandar

Key Value

Document Fees
INR 1180 /-
EMD
INR 59703.0 /-
Tender Value
INR 29.85 Lakhs /-

BOQ Items

Name of Work : Construction of Dual Gate (Vehicle Gate),Security Guard Room along with Morcha at CA Porbandar SH: Provision of Tyre Killers, Boom Barrier ,Bollard & Electrification works at C.A Porbandar
Sl. No. Item Description
1Supply, Installation, Testing Commissioning of Bidirectional Crash rated Electro Hydraulic Tyre killer of 7.00 Mtr length consisting of two section (3.5 Mtr + 3.5 Mtr) suitable to work on Three / single phase 400/230 volts +/- 5% ,50 Hz AC supply consisting of Tyre killer operating onhydraulic power system, PLC based, Stop/GO traffic light, single control panel for controlling two section,Accumulator system for Hydraulic operation in case of power failure including control switching operation in remote location (within 160 Mtr), logic circuit ,earthing, civil foundation including excavation of exisitng PQC & Bituminous road (at minimum 200mm depth) and making good after installation of tyre killers including provision of sump pump of suitable rating to drain accumulated water complete as required and supplying and laying of suitable size GI pipes and control cables (upto 160 Mtr), hydraulic system etc asrequired for complete functioning of tyre killers as per enclosed technical specifications (Crash rating test certificate from accredited authority shall be submitted by bidder).
2Supply, Installation, Testing Commissioning of Automatic Road Traffic Electro Mechanical Boom Barrier 3.5 Meter to 5 metre lengthof Two section suitable for 7.0 Mtr road to work on Three / single phase 400/230 volts +/- 5%, 50 Hz AC supply consisting of Boom Barrier Automatic, PLC based, control panel, including individual switching operation in local and remote location (within 30 Mtr) of two section logic circuit, earthing, civil foundation including excavation of exisitng PQC & Bituminous road (minimum 200mm depth) and making good after installation etc complete as required and supplying and laying of GI pipes and control cables (upto 30 Mtr) etc asrequired for complete as per enclosed technical specifications.
3Supply, Installation,Testing & Commissioning of K4 crash rated Electro Hydraulic Bollard system comprising of 07 (seven) numberof SS Bollards suitable to work on Three/Single phase 400/230 volt, 50 Hz AC supply consisting of hydraulic power unit, PLC based, logic circuit, control panel, Accumulator system for Hydraulic operation in case of power failure including switching operation in local and remote location (within 30 Mtr) complete as required including all major/minor civil works (excavation of PQC road of minimum 200mm depth) and making good after installation, and supplying and laying of GI pipes and control cables (upto 30 Mtr) comprising of following items and features as per enclosed technical specifications. i. Height – minimum-900mm ii. Bollard dia – minimum 275mm iii. Impact load – minimum 120KN or more iv. Operation time – 5 to 6 sec. max v. Frequency of operation – minimum 200 full cycles/hr. vi. Power off operation – Minimum three full cycle operation vii. Manual operations – integrated hand pump viii. Safety interlock detector. ix. Sump drain pump – self priming pump. x. Illuminating (LED) unit on top of bollard. xi. Control panel – UP/down/stop, middle stop operation & maintenance switch. xii. Axle load Bearing capacity - Shall be able to bear axle load of 20 tons of a moving vehicle. xii. Operating temp range – 20 to +60 deg. C and capable of meeting the rain fall requirement at Porbandar Airport.
4Supply of following sizes of XLPE insulated, PVC sheathed, Aluminium Conductor, Armoured Power Cable, 1.1 KV grade conforming to IS 7098 (Part-I) 1988 with upto date amendments, complete as required: 4 Core x 16 Sq. mm
5Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required: 4 Core x 16 Sq. mm
6Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
7Providing and fixing following rating and breaking capacity and pole MCCB with thermomagentic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required: 125A, 36KA, FP, MCCB
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
9Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.in the existing trench,complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
10Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit / submain wiring / cable as required.
11Providing and fixing of advance technology earth electrode earthing system fabricated from hot deep galvanized pipes (pipe in pipe technology) & cavity between pipes pressure filled with highly conductive non-corrosive crystalline material complete withchemically modified homogeneous earth enhancing compound (back fill compound 25 Kg or 50kg as per site requireemnt) to treat the soil for lowering the effective ground impedancefor each earth pit to make it maintenance free andto minimize the ground voltage potential rise i/cexcavation of earth pit suitable to accommodate earth electrode, prefabricated FRPenclosure withcover plate all as reqd. & conforming to(IS:3043 : 1987) duly CPRI/ERDA approved all as required & as specified for Size : - Outer pipe dia = 80mm Inner pipe dia = 50mm Length of electrode = 2 Mtr
12Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
13Providing, laying and fixing following dia GI pipe (medium class) in ground complete with GI fittings including trenching (75 cm deep) and refilling etc. as required. 50 mm dia
14Supplying and fixing of following way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 6 way, Double door
15Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
16Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Singlepole
17Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, Copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire.
18Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, Copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 4 sqmm + 1 x 4 sqmm earth wire.
19Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq. mm. FRLS, PVC insulated, copper conductor single core cablein surface/ recessed PVC conduit with modular switch, modular plate, suitable G.I. box and earthnig the point with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable etc. as required: (Group -A)
20Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
21Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
22Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
23Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, fan hooks / clamps etc. as required.
24Supplying and fixing of two module stepped type electronic fan regulator(Five stepped) on the existing modular plate of the switch box including connections but excluding modular plate etc. and suitable for operation on 230 / 240 Volts, 50 Hz, single phase, A.C. supply. etc. complete as required.
25Supply of 300 mm sweep heavy duty 1400 rpm exhaust fan suitable to operate on 240 Volts,50 Hz, single phase AC supply complete all as required & as specified.
26Supply of followingsizesof High speed ceilingfan withoutregulatorcompletewith doubleballbearing,motor,blades,downrod,canopy,capacitoretc.completeas required. 900mm sweep
27Supply of energy efficientLED tube light fixture with minimum system lumen output of 2100lumen,minimum luminaire Efficacy 100 lm/W,minimum CRI 80, IP 20 protected, minimum5 years warranty forcomplete LED lighting fixture including Driver and suitable to operate on 230v,50hz, single phase power supply etc. complete as required.