Tender For Maintenance Servicing Of Summer Appliances And Other Connected Work And Repair Maintenance Of Lt Distribution System Of Amu Node Saragrahi Pw Divi Sw Div And Other Areas Under Ge Mis Mhow, Indore-Madhya Pradesh

Military Engineer Services-MES has published Tender For Maintenance Servicing Of Summer Appliances And Other Connected Work And Repair Maintenance Of Lt Distribution System Of Amu Node Saragrahi Pw Divi Sw Div And Other Areas Under Ge Mis Mhow. Submission Date for this Tender is 15-03-2023. Air Conditioner Tenders in Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36277637
Corrigendum : Tender For Maintenance Servicing Of Summer Appliances And Other Connected Work And Repair Maintenance Of Lt Distribution System Of Amu Node Saragrahi Pw Divi Sw Div And Other Areas Under Ge Mis Mhow
Open Tender
Indian
Madhya Pradesh
Indore
15-03-2023

Tender Details

Maintenance Servicing Of Summer Appliances And Other Connected Work And Repair Maintenance Of Lt Distribution System Of Amu Node Saragrahi Pw Divi Sw Div And Other Areas Under Ge Mis Mhow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Feb-2023 Change in BOQ (Revise BOQ) BOQ 08-03-2023
2 08-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 43.98 Lakhs /-

BOQ Items

Name of Work: MAINTENANCE/SERVICING OFSUMMER APPLIANCES AND OTHER CONNECTED WORKAND REPAIR/MAINTENANCEOF LTDISTRIBUTION SYSTEM OF AMU NODE,SARAGRAHI,PW DIVI,SW DIV AND OTHER AREASUNDERGE (MIS) MHOW
Sl. No. Item Description
1M&L for removing the burnt/defective sealed compressor unit of any make from Windowtype air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit of Make: - Tecumseh Kirloskar, Model RNB 5522of rotary compressorby tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
2All as per item No 1 abovebut Air conditioner of 2 ton capacity and sealed compressor unit Make -Tecumseh Kirloskar, Model RNB 5529 complete all as specified and directed.
3M&L for removing the burnt/defective sealed compressor unit of Split type air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit Make - Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
4All as per item No 3 abovebut split type Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh, Model AW-2000 all as specified and directed.
5M&L for repairing, testing leakage in Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSI and repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete.
6All as per item No 5abovebut Air conditioner of 2 ton capacityand supply and charging refrigrerant gas F-22 (approx 2.30 Kg) complete.
7S&F in replacement of electric blower motor of capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves
8S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed at site.
9S&F in replacement of electric blower motor of capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
10S&F in replacement of electric blower motor of capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves.
11S & F in replacement of thermostat for window type AC, working on SP, 230V,AC complete all as specified Make : Indfos/ Ranutro
12S & F inreplacement of PCB circuit with remote control for air conditionerof any Make and capacity complete all as specified and directed.Make : Voltas/Carrier/Ranutrol/LG/Blue star
13S & F in replacement of air filter for split type Air conditioner (set of three Nos) Make-Marcon or other equivalent approved by GE complete all as specified and directed.
14S & F in replacement of air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and directed Make : Marcon or other equivalent as approved by GE.
15S & F in replacement of starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and directed.Make : Asian/Empire
16S & F in replacement of starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and directed.Make : Asian/Empire
17S & F in replacement of running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and directed. Make : Asian /Empire
18S & F in replacement of capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and directed. Make : Asian /Empire
19S & F in replacement of relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
20S & F copper filter pencil type of any make and capacity for Air conditionercomplete all as specified and directed. Make : VaishaliMetal or other equivalent as approved by GE.
21S&F in repair front PVC grill of window type AC of any make complete all as specified and directed at site.
22S & F in replacement of selector switch of window type AC complete all as specified and directed. Make- Blue star/Voltas
23S & F relay over load protector complete set suitable for AC complete all as specified and directed.
24S & F in replacement of relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
25S&F in repair indoor unit suitable for 1.5 TR split AC Make :voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
26S&F in repairoutdoor unit of split AC 1.5 Ton Make :voltas/LG/ Samsung with complete sealed compressor unit capacity 1.5 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigerating gas complete all as directed.
27S&F in repairindoor unit suitable for 2.0 TR split AC Make : voltas/ LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
28S&F in repair outdoor unit of split AC2.0 Ton Make : voltas/LG/ Samsung with complete sealed compressor unit capacity 2.0 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigeratinggas complete all as directed.
29SHIFTING OF AC"S:
30M&L for taking down and removing carefully split type AC complete with connected electric wires, copper tubing, insulation sleeves, outdoor unit fitting bracket etc from exiting placeand fixing the same at new location including necessary transpration, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including required copper tubing up to 2 running meter cleaning & flushing out complete system and, making the system leak proof, vaccumising the system supply & charging refrigerant gas F-22 (approx 2 Kg) in air conditioner 1.5 Tonto 2.0 ton including necessary making holes into wall for insertion of copper pipe etc and making good the disturbed surface as per existing and testing after installation complete all asdirected by Engineer-in Charge
31M&L for attending compliaints by checking the window type/split type AC of any capacity, Desert cooleretc of any make, size and capacity, and making the same functionable by tightening the connection, checking power point /socket point and replacement of screws, small pieces of wire, etc completeNote:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without and extra cost.
32S&F in repairs Copper tubing of following sizecomplete:-
333/8” size
345/8 ” size
351” size
361/4 ” size
371/2” size
38Supply and charging of gas R 134a in AC plant of any capacity complete all as specified and directed by Engineer-in-charge.Note:-Gas shall be suppliedin sealed and tested cylinder .
39M&L for repairing existing operating pannels of air conditioner (Cold store) of capacity 1.50/2 TR and making workable of incoming and outgoing connections complete all as specified and directed by Engneer-in-charge.
40M&L for profile insulation of outdoor unit complete all as specified and directed.
41S&F AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per existing complete all as specified and directed.
42S&F following parts complete all as specified and directed.
43Hand shut valve of size 5/8" Make- Synergn
44Pressure gauge (0-500 PSI)
45Valve 3 way
46Flair nut 3/4" brass
47Dead plug (brass)
48Union
49S&F MCCB four pole 63 Amp 16 KA 415 volts complete all as specified and directed.
50S&F in repairs Sheet metal enclosure with earth plug andsocket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed.
51S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.
52S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete.
53S&F in repairs MCB SP, 240 volts, 5 to 32 Amps, 10KA breaking capacity, "C" type including connection with suitable size aluminium /copper lugs complete all as directed
54M&L for Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete.
55M&L for Switch socket combination piano type 5/15 Amp, 230 volts AC, fixed in repairs complete.
56DESERT COOLERS :
57S & F in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18" sweep complete all as specified and directed. Make GE Motors/Auc/Crompton/ISI Mark
58S & F in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC complete all as specified and directed. Make : Crompton/cool- Home/GE Motors/ISI Marked
59S & F inreplacement wood-wool pad complete heavy size (set of three pads) approximately 400 gm weightcomplete all as specified and directed.
60S & F in replacement capacitor 6 MFD, 440V, complete all as specified and directed. Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark
61M&L for Scrapping down the complete existing paint of inside and out side of desert cooler cleaning the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and directed.
62S&Fin repairsDesert cooler electric driven single phase having nominalair flow capacity of 5400 cumper hour (peak), Honycab cooling media, water storage tank capacity 95/100 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 95 or other equivalentin Symphony / Blue star
63WATER COOLERS :
64Supply, fix & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia completeMake : GE Motor/AUE complete all as specified and directed
65All as per item No 53but 1/20 HP 1350 RPM with fan of 13" diacomplete all as specified and directed.
66All as per item No 53 but 1/35 HP,1350 RPM withfan of 10" dia complete all as specified and directed
67All as per item 53 above but 1/83 HP 1350 RPM and fan of 9" dia complete all as specified and directed.
68S & F in replacement of starting capacitor 40 to 60 MFD, 275 volts complete all as specified and directed. Make- Sharda/Empire/Bhel.
69All as per item No 57 above but of 60 to 80 MFD complete all as specified and directed.
70S & F in repairs of running capacitor 10 MFD 440 volts AC complete all as specified and directed Make: EPCOS/ Capro /Asian .
71All as per item No 59 above but of 15MFD complete all as specified and directed.
72All as per item No 59 above but of25/30 MFD complete all as specified and directed.
73S & F in replacement of thermostat for water cooler up to 150 litres capacity. complete all as specified and directed Make : Ranutrol/Danfoss/Indfos.
74S & F inreplacement of push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock). complete all as specified and directed. Make: King or other equivalent ISI marked as approved by GE
75S & F float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or other equivalent as approved by GE.
76M&L for Scrapping downthe existing water cooler painting completely ofany capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler including foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over a coat of red oxide primer withspray painting and writing SM/MES No with white/black paint all as directed.
77S & F starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
78S & F in repairs of over load protector for compressor of water cooler complete all as specified and directed.
79S & F of copper filter pencil type to any make and capacity of water cooler etc complete all as specified and directed. Make : VaishaliMetal
80S & F in replacement of capillary tubing having 0.050/0.055 bore complete all as specified and directed. Make : Vaishali Metal
81S & F of stop cock 15mm brass heavy duty (minimum weight 360 gm) complete all as specified and directed. Make: Leader, GEM, Jaquar
82S & F inreplacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5 meter long complete all as specified and directed
83M&L for removing the burnt/defective sealed compressor unit of any make from water cooler of capacity 60 litres/hours by cutting of suction and discharge lines and un-screwing the foundation nuts supply and fix of new sealed compressorunit make : Kirloskar/Emmersonmodel : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed by EIC.
84All as per item No 72 above but water cooler of capacity 80 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461etc complete.
85All as per item No 72 above but water cooler of capacity 150-150 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and directed.
86S & F in replacement PVC 3 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
87S & F in replacement PVC 4 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
88M & L for repairing, testing the leakage in system by charging of Nitrogen Gas up to 300 PSI and repairing of leakagespots/joints with gas welding work, cleaning and flushing the completewater cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 litres capacity
89M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc.complete all as specified and directed by EIC.
90M&L for replacement of water cooler inner tank made of stainless steel as per existing with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete for water cooler of 80 litres capacity all as specified and directed.
91All as per item No 79 but for water coolar of 150 litres capacity complete all as specified and direct ed at site.
92M&L for replacement of glass wool in 40/60/80/120 litres capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and directed.
93M&L for repairing of bottom base and legs of water cooler by providing suitable iron member, as per existing in pieces by necessasry welding work complete all as specified and directed.
94DEEP FREEZER :
95M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI and repairing the leakage spots/joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length and making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing after completion all as specified and directed.
96S & F inreplacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 all as specified and directed.
97S & F inreplacement of thermostat Auto defrost type for Deep freezer (Refrigeration of any make & capacity) complete all as specified and direct ed at site. Make : Ranutrol/Indfos
98M&L for removing burnt/defective sealed compressorunit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts,Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415including necessary gas welding making the system leak proof, testing andtightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
99All as per item No 87 above but of compressor Make-Tecumseh Model TSK-1350 complete all as specified and directed.
100S & F relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and directed.
101S & F in replacement of drier filter complete set suitable for deep freezer 215 / 386 litres complete all as specified and directed.
102S & F blower motor for Deep frizerSP 230V20 watts complete with fanincluding testing complete all as specified and directed
103REFRIGERATOR :
104S&F in repairs relay current type and overload protector complete suitable for compressor model KCE336, KCE345 complete all as specified and directed Make : Ranutrol/ Voltas /LG
105S&F in rpeairThermostat auto defrost type for refrigerators any make & capacity 165/310 litres Rerfrigerator complete all as specified and directed. Make : Danfos/Ind foss/Ranutrol
106S&F Vegitable tray as per existing and suitable for refrigerator of 300 litres capacity MakeGodrej, Voltas or whirlpool , LG.
107S&F in repairs evaporator suitable for Voltas/Godrej refrigerators capacityfixed in repairs 286/300 litres complete all as specified and directed.
108M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity(165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG,including necessary gas welding, making the system leak proof, including Repair to leakagesystem by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and making refrigerator for smooth functioningand charging of refrigerent gas 134a including necessary testing complete all as specified and directed
109Supply and charging / topping upof gas Freon- 22 complete all as specified and directed Note:- Gas shall be supplied in sealed and tested cylinder of capacity 10 Kg each.
110M&L for checking of AC supply electrical/electronics circuitary of water purification system, finding fault and rectification the same with repair of step down transformer 230 volt to 12/24 volts, and replacement of resistance , small pieces of wires etccomplete all as directed .
111S&F in repairof water purifier installed in various building of Infantry school and MH areaincluding replacement of candle 10"" filter set and cartrige, carbon filter and pri filter complete all as directed. Make- Aqua guard/ Beetek
112S&F in repair of water purifier and replacement of solonoid valve, PF nozzle, EVA tube, boul set etc installed in various building of Infantry school and MH areaand made functional complete all as directed. Make- Aqua guard/ Beetek
113M&L for checking the unserviceable plant (such as water cooler, refrigerator, Deep frizeretc) of any make, size and capacity, making the same serviceable functionable by tightening the connection, checking power point including, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without any extra cost.
114M&L for removing the burnt/defective sealed compressor unit of Tower typemake from any type of air conditioner capacity 4.0 Ton of 3 phase by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fix new sealed compressor unit make - DaikinModel JT160BCBY1L, Kirloskar or other equivalent as approved by GEby tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed.
115S & F inreplacement of PCB circuit with remote control forTower AC air conditionerof capacity4.0 Tonof any Make complete all as specified and directed .Make : Voltas/Lloyd/Blue star
116M&L for repairing leakage in system ofAir conditioner of 4.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fix filter pencil type copper cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 7.6 Kg) complete all as specified and directed.
117S&F in replacement of electricCondentioner motor ofcapacity6 P SP 230V, 50Hz,120 W for 4 Ton capacity Tower type Air conditioner of out door unit including testing completecomplete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves
118S&F in replacement of electric Blowermotor of capacity of8 P SP 230V, 50Hz,120 W for 4 Ton capacity Tower type Air conditioner of Indoor unitincluding testing complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
119S&F in replacement of Fan Blade for condentioner motor of Out door unitdia 560X169 capacityfor 4 Ton capacity Tower type Air conditioner including testingcomplete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves complete .
120S&F in replacement of Capacitor10 MFD for Fan of condentioner motor of Out door unitdia 560X169 capacityfor 4 Ton capacity Tower type Air conditioner including testing complete all as specified and directedMake : Renutral/ Epcos
121VOLTAGE STABLIZER :
122Taking out of deffective / burnt stablizer from various locations under GE (Maint) Infantry school Mhow of various capacity from 1 KVA to 5 KVA single phase and repair /replacement of the following defective parts and testing complete all as specified and directed. by Engineer-in-charge.
123Terminal strip
124Push button switch
125Rocker switch
126Circuit card from 3 to 5 KVA
127Circuit card from 1 to 2 KVA
128Relay 24 Volts 250 Ohms for 3 to 5 KVA
129Volt meter 0-300 volts size as per sample
130Indicator lamp (red/green)
131Booster /stabliser transformer 230 volts AC for3 to 5 KVA
132Booster / stabliser transformer 230 volts AC for1 to 2 KVA
133REPAIR/MAINTENANCEOF LTDISTRIBUTION SYSTEM:
134Excavation in trenchesin any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan for laying of cable, pipe, shafts, cesspits, manholes, pier holes, etc complete all as specified.
135Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
136Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
137M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. NOTE : Thickness shall be measured after panning down.
138M&L for old size sub class ‘B’ bricks, laid in trenches as cable covers .
139Supply and fixingSteel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
140S&F in repairs ACthree phase keypad based, BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) with bluetooth compatibility and mobile application. Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGEE/M store Yard.
141S&F in repairs AC single phase keypad based,BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) With bluetooth compatibility and mobile application Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGEE/M store Yard.
142S&F in repairs AC Single phase two wire static watt hour meter (Electronic KWH Energy meter) of rating 5-30 A, class 1.0,240 V,50 Hz,LCD Display.Make:- HPL Cat part No SPPB1310000000OC00 or other equivalent in SECURE / L&T Note :- Old electric meter shall be handed over to AGEE/M store Yard.
143S & F in replacement XLPE insulated and PVCarmoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 2 core 10 sqmm in trenches / through pipes / ducts or on poles / walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specifiedanddirected .Note : (a) Excavation shall be measured and paid seperately under respective items of Sch "A" (b) Allrequired lugs of suitable sizes according to size of cable shall deem to be included in the rate quoted.
144All as per item No 122 above butfor 16 Sqmm 4 core.
145All as per item No 122above butfor 50 Sqmm 3.5 core.
146All as per item No 122above butfor 95 Sqmm 3.5 core.
147All as per item No 122above butfor 120 Sqmm 3.5 core.
148S&F in repair MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA Make:- ABB/L&T/Schneider
149S&F in repair MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA Make:- ABB/L&T/Schneider
150S&F in repair MCCB 3 pole, 415 volts, adjustable type 160 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
151S&F in repair MCCB 3 pole, 415 volts, adjustable type 200 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
152S&F in repair MCCB 3 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
153S&F in repair MCCB 3 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
154S&F in repair MCCB 3 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
155S&F in repairs MCB TPN, 415V,40 Amps, "B" seriesMake:- ABB/L&T/Schneider
156S&F in repairs MCB SPN, 240V, 40 Amps "B" seriesMake:- ABB/L&T/Schneider
157S&F in repairs three phase contactor 5kW of load capacity 20-25 Amps, incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified and as directed . Make:- ABB/L&T/Schneider
158M&L for Re-stretching tightening and fixing in positionexisting OH ACSR conductor LT line 3 phase with neutral and earth wire 440 V, 5/6 wire by loosing includingtaking down the existing binding wire from the insulator of any sizeand bring ACSR conductor to required sag including provision of new binding wire and tightening of cross arm on each pole includingtrimming of tree branches contacted with OH conductor complete all as specified and directed by Engineer-in-Charge. Note :-1.Each line ofwire shallmeasured and paid . 2.Quotedrateshalldeemed to be includefor cutting and trimming of tree branches contactedwith ACSR conductor
159M&Lfor trimming / pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed . NOTE - (a) written shut down shall be obtained from concerned JE / AGE E/M before carrying out the trimming work in hand by contractor(b) span from one pole to next pole shall be 30m to 50m and shall be considered as a Each job (c) T & P such as ladder , rope, cutter , axes and other related material shall be provided by the contractor.
160S&F in repairLED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
161S&F in repairLED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
162S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light(Area light) of 50 Watt, suitable for highlighting architectural façade and general purpose lighting. Make :-BAJAJ Cat Part No : BJLF 50W LED Ior other equivalent inHavells /CG.
163M&L for repairing street / security light ofany type andflood lights / post top lanterns or any other external lights in its position fixed pole / building structure or by taking down to ground, if required and testing all the components / parts, wiring etc, identifying and replacing the defective components like choke (ballast), electronic driver (in case of LED Lights), ignitor, capacitor, lamp, lamp holder, connector, connection wires/ cable, MCB etc and refixing the fitting in its original position (if taken down), including repairing of street light control timer & junction box and makethelight fitting functionable in all respects complete all as directed by Engineer-in-charge.
164Note:-(a) Spares such as choke (ballast), electronic driver, Ignitor, capacitor, lamp, lamp holder, connector, connection wire, MCB, timer spares etc shall be measured & paid separately under respective items. (b) The contractors / Representative shall report to concerned JE E/M at 09.00 hours daily to collect the details of complaints of defective street lightfittings and shall submit the completion report of complaints of fitting on the same day before 17.30 hours to JE E/M. (c) The contractor shall rectify the defects / repair and make the street light functional within 24 hours fromthe time of handing over of complaint over by the concerned JE E/M.An amount ofRs 150/ dayper complaint shall be recovered from contractor if street light shall not be repaired and functionable within 24 hours.
165(d)Contractor shall arrange requisite and sufficient no of labours,ttransport and vehicle mounted hydraulic ladder etc at his own arrangement. (e)The contracor shall maintain proper record of repair/maint of light fittingsin a binded register duly showingthe details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall show therecord register to Engineer-in-charge for inspection every Monday or as and when asked for. (f)The contractor shall be fully responsible for the safety of his men engaged for executing this work and provide all requisite safety equipment and clothings etc to Electrician & Helper. Contractor shall be fully responsible for any kind of mishappening /accident / injury etc if any to his employed labours.
166(g) The contractor shall maintain sufficient stock of spares/material as required for repair/maint of street lights. (h) Contractor quoted rateshall be inclusive for screws, insulating tapes, internal wiring wire, gaskets and other minor items as required for repairing and making the street light fittings/security light fittingsin serviceable condition.
167Supply only following items/spares.
168Supply only LED driver of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specifiedMake:- Philips, Bajaj, Havells
169Supply only LED driver of capacity 30/36/45 watts rating 240 Volt, 50 Hz complete all as specifiedMake:- Philips, Bajaj, Havells
170S&F in repairsingle core pvc insulated and sheathed cable with multistranded aluminium condutor ofsize 2.5 sqmm and drawing in to existing GI pipe bracket and connect tostreet light fittings
171S&F in repairDigital Timer switch for 1x 24 Hrsfor controllingstreet light timimng with 150 hrs back up fixed in repairs.
172S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
173M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core fromLT O/H line/ LT UG cable etc. and taking out therequired length of cable from existing loop and remove cut the defective cable and replace the same with new cable as per existing size including providing necessarythimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and restore electric supply by making necessary electic connection andfunctionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge.
174All as per item No 147 above above but from switch gears /main switch board of any type and size including suitable size of aluminium cable lugs as required at site
175Supply only DO fuse elements of following capacity
1765 to 25 Amps suitable for 11 KV System
17730 Amps suitable for 11 KV System
1785 to 25 Amps suitable for 33 KV System
17930 Amps suitable for 33 KV System
180Supply ,fabrication, install and testingLT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 750 mm x 750 mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged doorshutter with locking arrangement and powder coatedpaintingfinish at both internal and external steel surfaces includingnecessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories andremoving old panel board of any description complete all as specified and as directed. . NOTE:- Quoted rate shall be inclusive forearthwork excavation,returning filling,removing soil , PCC worketc complete as required at site
181Aluminium strip busbar of 350 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos
1824 pole MCCB 200 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.Make:- L&T/ABB/Schneider
183LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.
184Digital Ammeter, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.
185Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No.
1864 Pole MCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 16 KA breaking capacity including all fixing accessories with both ends spreader links-05 Nos Make:- L&T/ABB/Schneider
187Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB .