Tender For Interior Furnishing For Digital Science Park At Kabani Building, Technocity, Thiruvananthapuram
Tender Overview
Project Description
Interior Furnishing For Digital Science Park At Kabani Building, Technocity, Thiruvananthapuram Work Include
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Feb-2023 | Corrigendum 2 | Technical Bid | 02-Mar-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | 4.2.2 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 3 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 4 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 5 | od339864/2022_2023 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Minimum cement content considered in this item is @ 330 kg/ cum. <br>All work above plinth level upto floor V level |
| 6 | 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 8 | od339867/2022_2023 : Designing, providing, installing and fixing factory finished custom designed cold<br>form Light Gauge Steel Framed super structure comprising of steel wall panel,<br> manufactured out of minimum 0.75 mm thick steel sheet as<br>per design requirements. The steel sheet shall be galvanized (AZ-150gms<br>Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa)<br>conforming to AISI specifications and IBC 2009 for cold formed steel framing<br>and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975.<br> LGSFS frame shall be<br>designed as per IS: 801 using commercially available software such as Frame<br>CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revit architecture-2011 or<br>equivalent. Proper usage of Connection Accessories like Heavy Duty Tension<br>Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural<br>stability. The framing section shall be cold form C-type having minimum web<br>depth 89 mm x 39mm flange x 11mm lip in required length as per structural design<br>requirement duly punched with dimple/slot at required locations as per approved<br>drawings. The slots will be along centre line of webs and shall be spaced minimum<br>250mm away from both ends of the member. The frame can be supplied in<br>panelized or knock down condition in specific dimensions and fastened with<br>screws extending through the steel beyond by minimum of three exposed threads.<br>All self drilling tapping screws for joining the members shall have a Type II coating<br>in accordance with ASTM B633(13) or equivalent corrosion protection of gauge<br>10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie<br>beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia<br>as per approved drawings. design subject to minimum 12mm diameter and 121mm<br>length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment<br>of 100mm in RCC (RCC to be paid separately) and located not more than 300mm<br>from corners or termination of bottom tracks complete in all respects. <br>The rate includes the concept design, detailed design, fabrication of<br>sections, transportation, installation and all required fixing arrangement at site<br>as described above. |
| 9 | od339868/2022_2023 : Providing and fixing INTERNALwall system on Light gauge steel frame work<br>with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm<br>thick heavy duty fiber cement board confirming to IS 14862:2000, category IV<br>type A (High pressure steam cured) as per standard sizes fixed with self-drilling<br>/ taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to<br>3mm shall be maintained and groves shall be sealed with silicon based sealant.<br>The board shall be fixed in a staggered pattern.Screws shall be of counter sunk<br>rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45<br>mm and internal face 12.5mm thick gypsum plaster board fixed on 8mm thick<br>fiber cement board confirming to IS 14862:2000 of category III type B (High<br>pressure steam cured) as per standard sizes fixed with self-drilling / taping screws<br>/ fasteners @ 60cm c/c of approved make, proper taping and jointing to be done<br>using fiber mesh tape and epoxy and acrylic based jointing compound for seamless<br>finish.(cost of frame work to be paid for separately).<br> |
| 10 | od339869/2022_2023 : Filling the groove (i.e. 2-3mm gap between boards),taping and jointing of the first<br>layer 6mm and 9mm thick fiber cement boards with epoxy based sealing<br>compound or with silicon sealant. Second layer is fixed over it in a staggered<br>pattern. |
| 11 | 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 12 | 11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 13 | 13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 14 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 15 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 16 | 13.88 : Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete |
| 17 | 9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 18 | 9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelledand glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane |
| 19 | 9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square |
| 20 | 9.21.2 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 21 | od339885/2022_2023 : " 9.22 Extra for Providing and fixing flush doors with decorative veneering instead of<br>non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)<br>9.22.1 On twosides"<br> |
| 22 | 9.23 : Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 23 | od339886/2022_2023 : Finishing wood work with Melamine polish with thinner (30%) : New work (Two or more coat applied @ 2.2 ltr/10 sqm) over and including two coats of melamine sealer with thinner (30%) @ 2.2 ltr/10 sqm and wood filler wherever required all complete as per the direction of engineer in charge.<br> |
| 24 | 9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 25 | 9.74.1 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm |
| 26 | 9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 27 | 9.155 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured).Panelling for paneled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587. |
| 28 | 21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness |
| 29 | od339887/2022_2023 : Providing and fixing 12 mm thick frameless toughened glass door shutterand fixed glass partitionof approved brand and manufacture including patch fittings, and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and heavy duty floor spring etc.to be paid separately). |
| 30 | od339888/2022_2023 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, for fixing required door fittings, all complete as per direction of Engineer-in charge (Door handle, lock and stopper etc.to be paid separately). |
| 31 | od339889/2022_2023 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. Heavy Duty Floor spring with door opening width upto 1200mm<br> |
| 32 | od339890/2022_2023 : Supply of SS corner lock for toughened glass door of 12mm thick with weight upto 200 kg |
| 33 | od339891/2022_2023 : Supply of stainless steel handle for toughened glass door, H- type of size 450 mm and 25 mm dia with satin finish of reputed make .<br> |
| 34 | 6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately). |
| 35 | 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 36 | 9.105.1 : Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated board conforming to IS : 2095 : part I |
| 37 | 12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 38 | 12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending |
| 39 | od339892/2022_2023 : Ceiling painting with acrylic water based spray paintof approved brand and<br>manufacture to give an even shade : Two coats on new work |
| 40 | od339893/2022_2023 : Providing and laying 20mm thick interlocking rubber tile of size 500x500mm including levelling and finishing of the proposed area all complete as per direction of engineer in charge |
| 41 | 18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall20 mm nominal outer dia pipes |
| 42 | 18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall25 mm nominal outer dia pipes |
| 43 | 18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes |
| 44 | 18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 45 | 18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 46 | od339894/2022_2023 : Providing and fixing PVC floor trap self cleansing design with or without vent arm complete including cutting and making good the walls and floors |
| 47 | od339895/2022_2023 : Providing and fixing SS gratingwith rim including setting in floor with white cement mortar and making good the floor125mm dia |
| 48 | od339896/2022_2023 : Providing and fixing UPVC SWRpipe for soil, waste and vent pipe to IS : 13592 of SWR quality, including all fittings, like: Bends, Tees, Elbows, Collars, junction, inspection doors, clamps for fixing walls and slabs, flanged pipes for providing slab core cuttingportion, vent cowls, offsets, access pipes, jointing with rubber ring / solvent cement by application of leak proof adhesive like FRP paste including cutting holes in walls and floors, chasing walls and floors and making good. clipping to walls and slabs, trenching, refilling etc. complete <br>50 mm dia uPVC 6kg/sq.cm pipe<br> |
| 49 | od339897/2022_2023 : Supply , jointing and fixingSWR type B Sanitary exposed pipes andspecials with good quality solvent cement and teflon tapeand fixing the same to line, plumb and level on the sides of ducts, walls, suspended to slabs as the case may be by using slotted rails , U clamps, 8mm threaded rods and other required materials including drilling holes,making good the walls, cleaning etc. and finishing complete : 75 mm diameter |
| 50 | FURNITURE |
| 51 | od339860/2022_2023 : "Supply and Installation of Reception table of size 2400x600x1050mm made out of PLB with pedestal and front facia unit with specifcations mentioned below<br>Top Material - 25 mm Prelam board with 2mm pvc edge banding & wire manager X 750 mm Height<br>Front Modesty Panel - 2400 X 18 X 750 in mm X 1, 18 mm Prelam board with 2mm pvc edge banding<br>Front Facia -1200 X 100 X 750 in mm X 1, 18 mm Prelam board with 2mm pvc edge banding<br>3 Drawer Pedestal unit -400 X 450 X 725 in mm X 1, 18 mm Prelam board with 2mm pvc edge banding<br>Gable Ends -600 X 25 mm thk X 725 X 2, 18 mm Prelam board with 2mm pvc edge banding<br>The model shall be approved by EIC."<br> |
| 52 | od339861/2022_2023 : Supply and installation of Conference table of size L 4800 X D2000 X H750mm made out of PLB legs and top as per the design <br> |
| 53 | od339862/2022_2023 : "Supply and Installation of ISLAND TABLES - 3800 (L) x 1500 (W) x 850 (H)<br>Pedestal Mounted design, Each modules are mounted on an independent self-standing square Continuously modular, Tables with top drawer and bottom cupboard of removable and accessible type on both sides with ensure maximum working and storage space Designed to withstand a load of 200 kg 300 per square ms. Created using 20 SWG Electro - Galvanized Sheet.<br>WORK TOP - Granite (18+/-1mm) Black Granite with half noosing with polished finished<br>CABINET - Cabinet are made of 1 or 1.2mm thick GI Sheet with Powder Coat Finish<br>HANDLES & ACCESSORIES - Integrated with door and drawer - EBCO HARDWARES<br>FAUCET - Brass body with ceramic valve core coated with epoxy resin powder<br>REAGENT RACK - 900 x 250 x 600 (L x W x H in mm), made out of 2 tier steel partition with, Two 15/5 Amps 3 pin electrical socket (Anchor roma Make)"<br> |
| 54 | od339863/2022_2023 : "Supply and Installation of Running tables along the wall in Electronics testing lab - top finished with Granite Designed to withstand a load of 200 kg 300 per square {M}, table top of width 600mm, will be made of 18 (+/- 1) mm finely polished thick black Color Granite with rounded edges, Bull nose /Chamfer Modularing6& groove at the bottom to avoid chemical spillage.<br>Under bench Modules will be made of 20 gauges pre- coated Galvanized Iron Sheet and completely finished with 60 – 70 microns thickness epoxy powder coating These modules will be provided with top drawer and bottom cupboard with horizontal removable inner partition and with lockable doors and aesthetic stainless steel handles. The under-bench modules will be arranged a lternatively, The base of the modules will be provided with skirting panels for aesthetic look."<br> |
| 55 | od339865/2022_2023 : "Supply and Installation of Running tables along the wall in Design and Characterization Lab - top finished with Granite Designed to withstand a load of 200 kg 300 per square {M}, table top with a width 600 mm, will be made of 18 (+/- 1) mm finely polished thick black Color Granite with rounded edges, Bull nose /Chamfer Modularing6& groove at the bottom to avoid chemical spillage.<br>Under bench Modules will be made of 20 gauges pre- coated Galvanized Iron Sheet and completely finished with 60 – 70 microns thickness epoxy powder coating These modules will be provided with top drawer and bottom cupboard with horizontal removable inner partition and with lockable doors and aesthetic stainless steel handles. The under-bench modules will be arranged a lternatively, The base of the modules will be provided with skirting panels for aesthetic look."<br> |
| 56 | od339866/2022_2023 : Supply and Installation of designercenter table ofsize 1200mm (L) x 600mm (W) x 450mm (H) Main Tablewith table topmade in 18 mm thick laminated particle board, frame work with SS pipe and with a shelf below made in 10 mm thick laminated particle board.The model shall be approved by EIC. |
| 57 | od339870/2022_2023 : Supply and Installation of Executive cabin tables with side table of size 1800 X 750 X 750 in mm made out ofPLB, along with pop up box to take face plate and switch ,socketsand with following specifications<br>Top Material 25 mm Prelam board with 2mm pvc edge banding & wire manager<br> Front Modesty Panel 1800 X 18 X 600 in mm X 1, 18 mm Prelam board with 2mm pvc edge banding <br>3 Drawer Pedestal unit 400 mm L X 400 mm W / D X 725 mm H In 18mm prelam board with 2mm liping X 1 Nos<br> Legs Material 25 mm Prelam board with 2mm pvc edge banding <br>Side Table 900 X 400 X 750 in mm X 1, 18 mm Prelam board with 2mm pvc edge banding |
| 58 | od339871/2022_2023 : Supply of medium backchairs for workstations, conference, discussion rooms etc with following specifications<br><br>Backrest, Nylon outer frame and imported<br>striped nylonmesh.<br>Depth Adjustable nylon cushioned lumbar<br>support.Armrest – Adjustable PP with fiber.<br>Seat upholstered with imported fabric.<br>Synchronized simple single lock<br>mechanism.<br><br>Powder coated TUV-CLASS 4 Gas spring<br>120mm, Certified with BOSQ logo engraved<br>to ensure bestin class quality.<br>Nylon Base with PU castors: 330mm.<br>Tested as per BIFMA X5.1 standards |
| 59 | od339872/2022_2023 : Supply of high back chair with head rest for manager cabins with following specifications. <br>Seat & Back Ergonomically designed L shape ply & Cushion with hi Density foam. <br>Upholstery with PU Leathrette . <br>Hand rest -Metal with PP <br>MechanismSyncro Knee Tilt & Syncro Tilt Mechanism <br>Height Adjustment by Gas Lift Chrome Base with twin caster wheels as base Metal |
| 60 | od339873/2022_2023 : Supply and installation of discussion table of size L 1800 X D1200 X H750mm made out of MS powder coated legsand Particle Board Edge Banded Topas per the design and as approved by EIC |
| 61 | od339874/2022_2023 : Providing Storage unit made out of 19mm thick BWR plywood finished with 1mm thick laminate on the outside and 0.8mm thick lamiante on the inside as per approved shade with required shelves for storing all pantry accessories and materials, table top to be finished with 20mm thick black galaxy granite with half moulding.<br> |
| 62 | od339875/2022_2023 : Supply & installation of SS sink with drain board including accessories like long body bib cock, angle valve, bottle trap, connection hose for pantry area. |
| 63 | od339876/2022_2023 : Supply & installation of Sink in workstations in Lab -Epoxy sinks/Polyolefin/Stainless Steel (Durable and Inert or resistance to Acids, oxidizing agents (L 525x W 430x D295mm), including all the accessories and fittings like multi taps, connectors etc.<br> |
| 64 | od339877/2022_2023 : Providing and fixing tall storage unit of size 2100x450x2100 mm with 18mm prelaminated board with 2mm pvc edge bondingsand having20x40x1.6mm thick M S base |
| 65 | od339878/2022_2023 : Providing low storage unit with 18mm prelaminated board with 2mm pvc edge bondings. Having M S base 20x40x1.6mm thick<br>Size 2600x600x750mm<br> |
| 66 | od339879/2022_2023 : Providing and fixing low storage unit of size1450x600x750mm with 18mm prelaminated board with 2mm pvc edge bondings and having M S base 20x40x1.6mm thick. |
| 67 | od339880/2022_2023 : Providing low storage unit with 18mm prelaminated board with 2mm pvc edge bondings. Having M S base 20x40x1.6mm thick<br>Size 2150x600x750mm<br> |
| 68 | od339881/2022_2023 : Supply ofLounge Chair in swan or similar shape made of metal base and upholstered in embossed fabricdesigned and developed for the lobby and reception areas withminimalist look and quality comfort features<br>Chair Width : 27'' x Chair Depth : 18.5'' x Chair Height : 31'<br><br> |
| 69 | od339882/2022_2023 : Supply & installation of Linear workstations Desking system made out ofMS - powder coatedframes with raceways on two level for data & electrical , 25mm thickwork top with 2mmpvc edge banding on all sides, Workstation consist of:- Table top pop up box, |
| 70 | od339883/2022_2023 : Supply & installation of mobile pedestals (for worksstations)made out of PLB with 3 drawers <br> |
| 71 | od339884/2022_2023 : "Providing and fixing ""ESD TABLE - 1500(L) x 900 (W) x 850 (H) with following specifications: Work Bench<br>shall be of Modular construction having Aluminum base frame, i.e. L- Shaped aluminum legs with height of 700mm (approx., forward table legs), 775mm (approx.), rear legs to incorporate cock pit). There shall be a Cockpit for instrumentation per work bench, ESD- safe work top shall have tie clamps, connectors, sockets, switches etc. mounted on a vertical /horizontal expand profile. The entire cabling shall be dressed properly and remain invisible. The work bench top shall be of raw chipboard allowing electro-static discharge with a thin chipboard as per DIN EN 61340-2-3 (Electrostatics –Protection of Electronics Devices from electrostatic phenomena) and DIN EN 61340-5-1 (volume conductive). The decorative side shall be with brilliant High Pressure Laminate (HPL), as per DIN EN 438 standards. Applicable standards ANSI-ESD S20.20-2014 & IEC 61340 standards: For Electro Static Discharge phenomena DIN EN 13150, EN 60335-1 & DIN VDE 0789: Standards for Safety Requirements for laboratory & classroom workstations. DIN EN 312: Standard for construction of High Pressure Laminated Worktops, Shelves"""<br> |
| 72 | Wiring |
| 73 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 74 | 1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 75 | 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 76 | 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 77 | 1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 78 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 79 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 80 | 1.22.11 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 100 mm deep |
| 81 | 1.22.16 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.250 mm X 300 mm X 100 mm deep |
| 82 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excludingmodular plate as required. |
| 83 | 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 84 | 1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 85 | 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 86 | MCCB, MCB &amp; DBs |
| 87 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door |
| 88 | 2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 89 | 2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 90 | 2.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 91 | 2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (butwithout MCB\"s and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 92 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 93 | 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 94 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 95 | 2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 96 | 2.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required. |
| 97 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 98 | 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 99 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 100 | 2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 101 | 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 102 | 2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 103 | 2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts \"C\" curve TP MCB complete withconnections, testing and commissioning etc. as required. |
| 104 | 2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 105 | 2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB |
| 106 | 2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB |
| 107 | 2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB |
| 108 | 90.11.1.19 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required |
| 109 | CABLE TRAY |
| 110 | 4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 111 | 4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 112 | EARTHING |
| 113 | 5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 114 | 90.16.3.2 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) |
| 115 | MV CABLE LAYING |
| 116 | 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 117 | 7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 118 | 7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 119 | 7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 120 | MV CABLE JOINTING &amp; END TERMINATION |
| 121 | 9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 122 | 9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 123 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 124 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 125 | 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 126 | od339983/2022_2023 :Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required4CX6Sqmm<br> |
| 127 | LIGHTING CONTROLS |
| 128 | 15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required |
| 129 | UPS |
| 130 | od339969/2022_2023 : Supply, Installation Testing and commissioning ofdouble convertion, DSP Based, True on line UPS systemas per IEC 62040-3 with 415V +/- 15% V,50Hz,3Ph Input & 415V,3Ph,50 Hz , Output, working on 16 Bit microprocessor Architecture, with in built Isolationtransformers,RS 232 ports, monitoring software , O/L.S.C. protections & self diagnostic features,LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors,Invertors, rectifiers & Battery Charger shallutilize PWM technology with IGBT. Battery Back up time of 30 minutes with required No of 'SMF Battery with Battery managementSystem, housed insuitable Cabinet /stand,Static ByPass, complete withInternal wiring & all accessories to be provided. Proper earthing as perUPS vendor specfication should be provided.<br>The System shall have in-built P.F.correction(Output > 0.9) & shall ensure THD as per latest International standards. Also UPS shall be compactiable with genset supply. The efficiency of UPS shall be not less than 95% .<br>The necesary cabling and terminations from isolator to UPS and UPS to isolatorl also should be provided.UPS shall be capable of over loadcapacity 110 % for 60 min , 125 % fo 10 min, 150% for 60 sec. Proper earthing as perUPS vendor specfication should be provided.<br> Suitable ratedheavy duty, Valve Regulatedmaintenance freeBattery unitincludingfloor Mounted Battery Racks, Interconnecting cables, Batteries duly charged and complete with all accessories, etc. The Rack shall be painted with Anti-Acid Resistant paint. <br>40 kVA with Individual Battery Bank<br> |
| 131 | LT CABLES |
| 132 | od339968/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5 C x 50 sq.mm <br> |
| 133 | od339970/2022_2023 :Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date 3.5Cx 95 sqmm<br> |
| 134 | od339974/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date 4 C x25 sq.mm<br> |
| 135 | od339978/2022_2023 :Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date4 C x 16 sqmm<br> |
| 136 | od339980/2022_2023 :Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date4 C x 10 sqmm<br> |
| 137 | od339982/2022_2023 :Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date4C x 6sqmm<br> |
| 138 | LIGHT FITTINGS & FANS |
| 139 | od339967/2022_2023 : Note:All lightning Luminaire shall have fixed with ElectronicBallast, starters, control gears (Eg:- LED driver unit ) and necessary all connected accessories, supporting bracket/chain suspender, balance socket, suspension/flexible conduit, hooks, clamps, screws, connectors, terminalblocks,flexible wire with flexible hose & suitable gland from light point to lighting luminaries, cabling / wires to luminaries from ceiling rose or junction box etc.. complete as required without any extra cost.<br>Supply of 20-24W LEDBatten surface mounting luminaire with extruded aluminium with powder coated housing, high translucent frosted diffuser,including all necessary accessories completeas required.(Crompton LDL-20-CDL/ Wipro LL20-111-XXX-65NE3/HavellsLUMILINEPLUSNEOBS20WLED865SPCSSIND ).<br> |
| 140 | od339972/2022_2023 : Supply and installation of compact Recess mounted 33-36W LED luminaireCRCA with powder coated housing, frosted PMMA / PC diffuser, gives soft glare free light & complete with electronic driver including all required mounting accessories as required . (Crompton LCTLRNE-36-FO-CDL / WiproCRCO10R038HP57G1L1 /HavellsVENUSNEO2X2PLR36WLED857POS).<br> |
| 141 | od339973/2022_2023 : Supply and installation of 20-25W linear suspended luminaire with extruded aluminium housing with diffuser for standalone aswell as end to end connectivity including all necessary accessories for mounting the light with 2 suspensions from the ceiling.(Wipro LM22-251-XXX-57-BX/Havells DESTG250LP/S25WLED857SWH1130/Crompton)<br> |
| 142 | od339976/2022_2023 : Supply and installation of Wall fan 400 mm sweep, 230V.1Ph, plastic body and blades,pullcord for speed regulation etc complete with all accessories as required. (Make: Crompton High flo wave plus / Havells Swing /bajaj esteem) <br> |
| 143 | MISCELLANEOUS |
| 144 | od339966/2022_2023 : Supplying and fixing of following rating 415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB/enclosurecomplete with connections, testing and commissioning etc. as required.<br>40A / 63A TP/FP C curve MCB<br> |
| 145 | od339971/2022_2023 : Supply and fixing of the following rated MCCB in the existing sheet steel enclosure/ Vertical DB/tap off box for use on 3 phase 4 wire 415 volts, 50Hz AC complete with all necessary accessories as required. <br> <br>100A FP MCCB<br> |
| 146 | od339975/2022_2023 : Supply and fixing of the following rated MCCB in the existing sheet steel enclosure/ Vertical DB/tap off box for use on 3 phase 4 wire 415 volts, 50Hz AC complete with all necessary accessories as required 160A25 KA TPN MCCB<br> |
| 147 | od339977/2022_2023 : Supplying and fixing of TPN/FP sheet enclosureon surface/ recess for mountingMCB complete with connections, testing and commissioning etc. as required.<br> |
| 148 | od339979/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 20A DP switch & socket with indicator, connection etc. as required.<br> |
| 149 | od339981/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing retractable extension cord reel with 3 electrical power outlets with all accessories for hanging from the ceiling including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.complete as required<br> |
| 150 | od339984/2022_2023 : Supply and laying of underfloor trunking of size 300x38x2x2,three compartmentalised having all necessary accessories such as covering lid, joint sleeves,vertical access box,access outlex box for mounting the trunking complete as required.<br> |
| 151 | od339985/2022_2023 : Supply and laying of cross over/junction box of size 350x350x60-75 mm 3 comp,three compartmentalised having all necessary accessories such as covering lid, etc complete as required.<br> |
| 152 | od339986/2022_2023 : Supply and laying of underfloor trunking of size 300x38x1.6,three compartmentalised having all necessary accessories such as covering lid, joint sleeves,etc for mounting the trunking complete as required.<br> |
| 153 | od339987/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos 3 pin 5/6 amps modular socket outlet and 2nos 5/6 amps modular switch, connection etc. as required. (for light plugs to be used in non residential buildings.)<br> |
| 154 | od339988/2022_2023 : Supplying and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. <br> |
| 155 | od339989/2022_2023 : Supplying and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch,including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.<br> |
| 156 | od339990/2022_2023 : Supply, Installation, Testing & Commissioning of SF OFFICE PANEL 3, cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. <br>Incomer<br>160A, TP+NL, 25kA, MCCB with thermal magnetic release with adjustable OL, SC protection - 1 no. <br>Busbar<br>1 Set of 160 A TPN busbars of high conductivity electrolytic quality aluminiumconductor and suitable size earthing conductor through out the panel for its earthing. <br>Instruments<br>2A, C curve SP MCB - 1 set<br>RYB indication lamp, LED type - 1 set<br>1 set 3 phase Digital Multi function meter to read V, A, F, PF, KW,KWHAcc class 1 and with necessary accessories.<br>160/5A 15VA class 1 resin cast CT - 1 set<br>Outgoing.<br>100A, TP+NL, 16kA, MCCB with thermal magnetic release for adjustable OL, SC protection - 1 nos. <br>63A, TP+NL, 16kA, MCCB with thermal magnetic release for adjustable OL, SC protection - 5 nos. <br> |
| 157 | HVAC Works |
| 158 | od339745/2022_2023 : "SITC of CO2 Sensor with Control Panel for controlling the motorized damper installed at site, along with necessary cabling between the control panel and motorized damper. The item should be including all necessary fittings etc as per requirement. The detailed description is as followsS.I.T.C. of Room/Duct type Carbon Dioxide Transmitter<br>Media: air or non aggressive gases<br>Sensor type: NDIR, with automatic background calibration<br>Range: 400-2000, 0-2000, 5000, 10000PPM (dip switch settable)<br>Output: 4-20mA and 0-10V both output required<br>Response time: 20sec., 60sec (dip switch settable)<br>Accuracy: 70PPM +3% of reading <br>Housing material: ABS<br>Protection: IP41 for room mount/IP65 for duct mount<br>Operating tem.&RH range: 0~50°C & 0~85%RH non cond.<br>Standards: EMC directive EN61326-1<br>Power supply: 24VAC/24VDC<br>Approval: CE/UL<br>Approved makes: Honeywell, Siemens, Johnson, Schneider, Nextech"<br> |
| 159 | od339748/2022_2023 : Supply, Installation, Testing and Commissioning of GI VOLUME CONTROL DAMPERS complete with neoprene rubber gaskets,nuts,bolts,screw linkages,flanges etc. as per specifications.<br> |
| 160 | od339750/2022_2023 : Supply,installation balancing and commisnioning ofsite / factory fabricated GSS sheet metal ducts rectangular ducting complete with neoprene rubber gaskets,elbows,splitter,dampers,vanes,hangers,supports etc as per approved drawings & specification of following sheet thickness<br>Thickness 0.6 mm sheet<br> |
| 161 | od339752/2022_2023 : Supplying and fixing of following thickness closed cell Anti Microbial Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. The insulation to be done inside the duct.<br>19 mm<br> |
| 162 | od339753/2022_2023 : Supply, installation, testing and commissioningof Acoustic duct lining using 10mm nitrile rubber insulation open cell type inside the ducts, antimicrobial protection at the outlets of all indoor units upto 4m distance from fan outlet as per spec provided.<br> |
| 163 | od339756/2022_2023 : Supply & Installation of Canvass connection out ofsynthetic SRF cloth with zip fastener for measuring temperature at the outlet of AHU/TFA.<br> |
| 164 | od339758/2022_2023 : Supply & fixing of powder coated extruded aluminium SUPPLY AIR DIFFUSER with aluminium volume control dampers as per specification with anti smudge ring & removable core. Neck size will be considering for measurment.<br> |
| 165 | od339759/2022_2023 : Supply & fixing of powder coated extruded aluminium RETURN AIR DIFFUSER with louvers without volume control dampers as per specification anti smudge ring & removable core.<br> |
| 166 | od339760/2022_2023 : Providing of spray painting over GI ducts at all level and height of approved makesand shade including primer coating complete in all respect and as per direction of the engineer incharge.<br> |
| 167 | od339761/2022_2023 : Supply, installation, testing and commissioning of Air Cooled Inverter type High Wall mounted Split Air Conditioner of following capacity consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressorfor operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room& condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigarant gas, suitable stabilizer etc complete as required.<br>1 TR 5 star rated<br> |
| 168 | od339762/2022_2023 : Supply, installation, testing and commissioning ofsuitable hard/soft drawn copper refrigerant piping for above machines with 13 mm nitrile rubber insulation interconnecting the condensing unit to evaporating unit as per site condition.The piping measurment should be given for above 4 meter for each unit. Upto 3 meters piping should be included in the equipment / unit price.<br> |
| 169 | od339763/2022_2023 : Supply, installation, testing and commissioning, Transmission/Communication cabling, ofsuitable sizenon polar sheliedcablefor interconnecting the Indoor and Outdoor Units / Unit to isolator of all the Units for proper performance. The cable measurment should be given for above 3 meter cabling for each unit. Upto 3 meters cabling should be included in the equipment / unit price.<br> |
| 170 | od339764/2022_2023 : Supply, installation, testing and commissioning of drain piping of hard PVC pipe and fittings, insulated with 12 mm thick nitrile rubber.<br>25mm<br> |
| 171 | od339765/2022_2023 : Supply, installation, testing and commissioning of drain piping of hard PVC pipe and fittings, insulated with 12 mm thick nitrile rubber.<br>32 mm<br> |
| 172 | Fire Fighting Works |
| 173 | od339746/2022_2023 : Supply, installation, testing and commissioning of approved make 15mm dia brass Sprinkler heads, quick response, designed to operate at 68 deg. Celsius etc. with necessery fittings,rosette plate etc of Pendant type<br> |
| 174 | od339747/2022_2023 : Supplying, fixing, testing & commissioning of Sprinkler Flexible Hose 1000 mm in length, Unbraided, UL Listed along with all necessary accessories like Nipple threaded , Reducing Nipple threaded, Large Bracket with Bolt, Small Bracket with Bolt, clamps,reduser collar,Meter Square Bar etc complete as per spec.<br> |
| 175 | od339749/2022_2023 : Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted.<br>ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets<br> |
| 176 | od339751/2022_2023 : Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted.<br>ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.<br> |
| 177 | od339754/2022_2023 : Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted.<br>ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and confoming to IS:1349-1993.<br>2 Kg<br> |
| 178 | od339755/2022_2023 : Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted.<br>ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and confoming to IS:1349-1993.<br>4 Kg<br> |
| 179 | od339757/2022_2023 : Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted.<br>Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 <br>50 Litres (trolley mounted)<br> |
| 180 | TELEPHONE SYSTEM |
| 181 | 1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 182 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 183 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 184 | 1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 185 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 186 | 4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 187 | od340370/2022_2023 : Supply,laying and termination of 20 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray<br> |
| 188 | od340376/2022_2023 : Supply,laying and termination of 50 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray<br> |
| 189 | od340381/2022_2023 : Supply,laying and termination of 20 pair telephone terminal block housed in engineering plastic box with transparent hinged door <br> |
| 190 | od340384/2022_2023 : Supply,laying and termination of 30 pair telephone terminal block housed in engineering plastic box with transparent hinged door <br> |
| 191 | od340387/2022_2023 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/ provided in the existing cable cubby for workstation/on the partition wall or furniture including connections but excluding modular plate etc as required.<br>Telephone socket<br> |
| 192 | od340391/2022_2023 : Supply and fixing of corded landline phone including one base unit, one handset,one main line cord and one coil cord etc including all accessories complete as required<br> |
| 193 | od340395/2022_2023 : Supply and fixing of corded landline phone including one base unit, one handset,one main line cord and one coil cord with 16 digit LCD display,one touch memory button,2way speaker phone etc including all accessories complete as required<br> |
| 194 | od340396/2022_2023 : "Supply,installation,testing and commissioning of EPABX with Hot Standby Redundant Controls configured for: 1. 80 Analog Extensions with CLI Expandable to 150 Ports<br>2. 05 Port Analog trunk with CLI and Power Failure Transfer and with Protection modules.<br>3. 01nos PRI.<br>4. 01nos Operator Console with 30 Direct selection Keys. <br>5. 08 Port Voice Guidance to announce Extension Busy status, Wake up call announcement and other important telephone features,Auto Attendant facility for Welcome message announcement.<br>6. 2Nos -100 pair MDF(wall mountable)<br>7. 01 No. Call Billing and monitoring Software.<br>8. Charger/UPS with Batteries for backup of1 hours."<br> |
| 195 | DATA SYSTEM |
| 196 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 197 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 198 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 199 | 1.53.3 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable |
| 200 | 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 201 | 1.53.2 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable |
| 202 | 4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 203 | od340378/2022_2023 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/provided in the existing cable cubby for workstation/on the partition wall or furniture including connections but excluding modular plate etc as required. RJ 45 socket<br> |
| 204 | od340377/2022_2023 : Supply and installation of Cat-6 shuttered 24 port patch panel <br> |
| 205 | od340383/2022_2023 : Supply, installation, testing & commissioning of 24 port10/100/1000Mbps+4port 10G SFP + Managed switch<br> |
| 206 | od340386/2022_2023 : Supply of 24 10/100/1000BASE-T ports + 2 10GBASE-T ports + 4 10G SFP+ ports, L3 Stackable Managed switch<br> |
| 207 | od340388/2022_2023 : Supply and installation of Cat 6 UTP patch cord, 1 mtr<br> |
| 208 | od340393/2022_2023 : Supply and installation of 6U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19" mounting angles, top, bottom open, RAL 9005 with all other accessories<br> |
| 209 | od340399/2022_2023 : Supply and installation of 9U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19" mounting angles, top, bottom open, RAL 9005 with all other accessories<br> |
| 210 | od340400/2022_2023 : "Supply and installation of Tri band Mesh router and satellite.Should have 1 mesh router and 1 satellite<br>Tri band<br>Band 1<br>IEEE 802.11b/g/n/ax 2.4GHz - 256QAM support.<br>Band 2<br>IEEE 802.11a/n/ac/ax 5GHz - 1024QAM support.<br>IEEE 802.11a/n/ac/ax 5GHz - 1024QAM support.<br>Antenna ( internal/external ) :Should have atleast Eight (8) high-performance<br>antennas with high-power amplifiers.<br>OFDMA and bi-directional MU-MIMO WiFi 6 throughput. MU-MIMO Implicit/Explicit<br>Beamforming for 2.4GHz and 5GHz bands.<br>Ports<br>Router :<br>Internet Port for Router Unit should have atleast one 2.5Gbps Ethernet<br>Local Area Network Ports for Router Unit should have atleast four nos GbE, of<br>which two can be formed in a LAG(Link Aggregation Grouping).<br>Local Area Network Ports for Satellite Unit atleast one 2.5GbE; and atleast four nos<br>WPA/WPA2/WPA3 support.The item should be AX 6000 or more.The item shall include necessary wall mounting facility."<br> |
| 211 | CCTV SYSTEM |
| 212 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 213 | 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 214 | od340365/2022_2023 : Supply ,installation, testing and commissioning of IP based IR Fixed dome Camera, 1/ 3" CMOS, 4MP, night vision compatible ,IR range of up to 30m,lens 2.8mm fixed, video compression H.264/H.264B/H.265, Frame Rate 4MP at (1~20/30fbs), Interoperability ONVIF, Die-cast aluminum housing with powder coat, IP 66,IK10,FCC,EN & ROHS certified. All mounting accessories shall be included<br> |
| 215 | od340366/2022_2023 : Supply,installation, testing and commissioning of IP Network Video Recorders 16 channel with 16 ports, 2 SATA, audio 1 input 1 output, video 1 HDMI 1 VGA, recording resolution 5MP/3MP/1080P, 720P/ D1 @ 30 fps, network throughput 200 Mbps from IPC and 128 Mbps to Client, Smart search supported, Remote access by DDNS & P2P, 4 channel alarm input and 2 channel relay output, 2 USB ports, ONVIF, UL & CE certified.<br> |
| 216 | od340373/2022_2023 : Supply installation testing and commissioning ofof 24 port-24-Ports 10/100/1000Mbps PoE + 4-Port Combo giga SFP & Copper ports L2 Managed switch,193W PoE switch<br> |
| 217 | od340374/2022_2023 : Supply and installation of Cat 6 UTP patch cord, 1 mtr<br> |
| 218 | od340377/2022_2023 : Supply and installation of Cat-6 shuttered 24 port patch panel <br> |
| 219 | od340390/2022_2023 : Supply, installation, testing and commissioning of Surveillance/ ESATA compatible Hard Disk of 10TB capacity to achieve the total storage for the NVR server<br> |
| 220 | od340392/2022_2023 : Supply, Installation, Testing & Commissioning of 21 inch full HD LED monitor with resolution 1920X1080 pixel including wall mounting accessories (location: security room & central control room).Material shall be UL/CE listed<br> |
| 221 | od340397/2022_2023 : Supply and installation of wallmounted 9U rackincluding cable manager, power supply units etc.to accommodate ehternet switch and fiber patch panel at each floor <br> |
| 222 | TV SYSTEM |
| 223 | 1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. |
| 224 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 225 | 1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 226 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 227 | 4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 228 | od340369/2022_2023 : Supply and installation of 9U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19" mounting angles, top, bottom open, RAL 9005 with all other accessories<br> |
| 229 | od340372/2022_2023 : Supply and Installation of 43 inches ultra HD smart LED TV including all mounting accessories , AC adaptors, power cord, remote control, etc complete as required.<br> |
| 230 | AV SYSTEM |
| 231 | od340375/2022_2023 : VIDEO SYSTEM<br>""SITC of Interactive Flat panel display 75"",Resolution:4K UHD,4mm Toughened Anti-glare Glass with Level 7 of MOHS, Wireless control over network,Brightness:400 nits, Response Time: 8ms,Accuracy<2mm,RAM: 3GB,ROM:32GB,Touch point:20, Touch Technology:infrared, Pen:2, Screen Mirroring,inbuilt speaker, Multiplatform Connectivity, Annotation, Quad screen multi tasking, screen recorder, bluetooth, Android 8, OPS with 8GB DDR3 RAM windows license and mounting accessories.<br>"<br> |
| 232 | od340379/2022_2023 : Supply, Installation, Testing and Commissioning of web camera having ½.7”, CMOS sensor with 2 MP, angle of view 120degrees. The system should support 1080p@30fps/25fps, 720p@30fps/25fps,960x540p@30fps/25fps, 640x360p@30fps/25fps, 2D & 3D noise reduction having USB 2.0 or better interface. The system should have built in microphone array with omnidirectional pickup and pickup distance of 5m, Auto/Manual white balance., YUY2/H.264/MJPEG, USB powered, supporting UVC 1.0 or better. It should have CE & latest CB certification and also CB test reports. The item shall also include cable for connectivity 5meter USB 2.0 extension cable and mounting accessories.<br> |
| 233 | od340380/2022_2023 : Supply, Installation,Testing and Commissioning of Two-Input Switcher for HDMI and USB-C with USB Hub : Two-input AV switcher with HDMIand USB-C input for AV and data, Integrated 2X USB 3.0 hub plus 1X USB Host , 4K/UHD capability @ 60 Hz with 4:4:4 chroma sampling, plus support for HDR formats, Selectable 4K to 1080p downscaling, Automatic input selection and automatic display control, Audio de-embedding.<br> |
| 234 | od340382/2022_2023 : Supply & laying of VARIOUS AV CABLES AND CONNECTOR<br>8U Equipment Rack<br> |
| 235 | od340385/2022_2023 : Supply & laying of Flexible 4K, 18 GBPS HDMI Cable : 2 Mtr<br> |
| 236 | od340389/2022_2023 : Supply & laying of Flexible USB-C to USB-C (AV Alternate) - 2Mtr <br> |
| 237 | od340394/2022_2023 : Supply and laying of HDMI Cable : 5Mtr<br> |
| 238 | od340398/2022_2023 : Supply and laying of HDMI Cable : 10Mtr<br> |
| 239 | od340401/2022_2023 : Supply and laying of USB Cable - 5Mtr <br> |
| 240 | ACCESS CONTROL SYSTEM |
| 241 | od340361/2022_2023 : Supply Installation Testing and Commissioning of Biometric cum proximity card reader system.<br> |
| 242 | od340362/2022_2023 : Supply Installation Testing and Commissioning of Exit switch.<br> |
| 243 | od340363/2022_2023 : Supply Installation Testing and Commissioning of Access Control System cum time attendance software<br> |
| 244 | od340364/2022_2023 : Supply, Installation, Testing & Commissioning of Electromagnetic dual lock<br> |
| 245 | od340367/2022_2023 : Supply, Installation, Testing & Commissioning of bracket for Electromagnetic dual lock<br> |
| 246 | od340368/2022_2023 : Supply & Installation of proximity cards<br> |
| 247 | od340371/2022_2023 : Supply, Installation, Testing & Commssioning of ACS Management Server<br> |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents