Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone A Under Ge Af Tech Area Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone A Under Ge Af Tech Area Agra. Submission Date for this Tender is 14-03-2023. Diesel Generators Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36266769
Corrigendum : Tender For Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone A Under Ge Af Tech Area Agra
Open Tender
Indian
Uttar Pradesh
agra
14-03-2023

Tender Details

Repair And Maintenance Of Dg Set And Amf Panel For Stand By Dg Set In Zone A Under Ge Af Tech Area Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Feb-2023 Corrigendum1 BOQ 07-03-2023
2 03-Mar-2023 Corrigendum2 Other 07-03-2023
3 07-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 54000.0 /-
Tender Value
INR 27 Lakhs /-

BOQ Items

Name of Work: REPAIR & MAINTENANCE OF DG SET ANDAMF PANEL FOR STAND BY DG SET IN ZONE "A" UNDER AF STN AGRAUNDER GE (AF) TECH AREA, AGRA
Sl. No. Item Description
1M&L for servicingofupto40KVA DG set including replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oilcomplete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
2M&L for servicing50 KVA to 82.5 KVADG setincluding replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oilcomplete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop ofmanufactured company or his authorised representative.
3M&L for servicing of 100to180 KVA DG setincluding replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop ofmanufactured company or his authorised representative.
4M&L for servicing of200to320 KVAKVA DG set including replacement Engine oil and all type offilters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and fillingandtopping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule "A".(b)Each servicing of DG Setwill be required after6 months or250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop of manufactured company or his authorised representative.
5M&L For dismantling the engine of DG Set capacity 125 to 320 KVA for checking and repairing , overhauling work by opening complete engine head piston, cylinder and FIP unit including remote cylinder head covers&check valve clearance between rocker arms and valve stem end wirth filler guage as per the valve setting sequence 0.3mm for inlet valve and 0.5mm for exhaust valve reassembling the existing parts complete testing on full load all as specified and as directed by Engr-in Charge. Note :- Replaced major spare parts Items required to make the DG set serviceable shall be measured and paid seperately under relevent item of schedule as supply only.
6Supply only kit engine piston
7Supply only piston liner kit
8Supply only starter 12V DC complete
9Supply only oil seal rear
10Supply only bearing thurst
11Supply only sleeve injector
12Supply only valve inlet
13Supply only valve exhaust
14Supply only starter ring 121 teeth,3175 module
15Supply only valve seat
16Supply only ring liner seal
17Supply only gear wheel complete
18Supply only gasket ofhead gaskets, body gaskets complete
19Supply and filling ofEngine oil15 W / 40 complete all as specified and directed. Make :- Castrol / HP /Bharat Petrolium / Valvoline
20Supplyand filling of coolant suitable forradiater of DG sets complete all as specified and directed. Make: HP/TVS / Valvoline / KIRLOSKAR
21S&F in renewal of battery terminal brass(heavy duty)with nuts & bolts (as per sample) complete all as specified and directed.
22Supply and filling distilled water suitable for DG set complete all as specified and directed.
23Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion , rewinding of armature , bushes set , rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter of DG Set for capacity upto 82.5 KVA Complete all as specified and directed.
24Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion, rewinding of armature, bushes set,rewinding of field coil assembly, reassembling and refilledincluding testing of the complete self starter of DG Setfor capacity from 100 to 160 KVA Complete all as specified and directed.
25Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator, loading transportation and unloading& including refixing to its old position with proper accuracy and correct situationforCapacity from 20 KVA to 40 KVA DG sets including renewal MS/GI of nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
26Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator loading, transportation and unloading& including refixing to its old position with proper accuracy and correct situationforCapacity from 62.5 to 82.5 KVA DG sets including renewal ofMS/GInut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
27Taking down old repairable Radiator by opening nut/bolt from foundation and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator unloading and transportation and unloading& including refixing to its old position with proper accuracy and correct situationforCapacity from 100 KVA to 160 KVA DG sets including renewal of MS/GInut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
28Taking down old Radiator by opening nut/bolt from foundation and supply, installing and testing new Radiator with proper accuracy and correct situationfor Capacity from upto 200 KVA DG setsincluding MS/ GI nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
29M & L for disconnection, taking down and repairing of alternator DC from DG set engine with rewinding of armature ,renewal of carbon brushes, renewal of bearings, rewinding of field coil assembly, renewal of connection plate,reassembling and refixing to DG set engine after necessary repair for the following sizes complete all as specified and directed:-
3012 Volt
3124 Volt
32M & L for repairing of automatic battery charger of12 Volt / 24 Volts including rewinding of transformer unit and renewal ofdiode plates, rectifier plates,auto cut mosfet circuit , fuses etc. and testing for following sizes complete all as specified and directed:-
3312 Volt
3424 Volt
35M & L for repairing of canopy doors complete with renewal of following items including denting and necessary welding of doors complete all as specified and directed:-
36M.S. Door lockof size 5.75" x 4.5" and of 08 levers
37M.S.door handle of 150mm size
38M.S. Butt hinges of 100 mm size
39M & L in renewal of flywheel ringwith proper setting and alignmentfor 100 to 160KVA DG set complete all as specified and directed.
40M & L for renewal of Magnetic Pickup suitable for 100 KVA & 200 KVA DG set complete all as specified and directed. Make:- Cummins/ KIRLOSKAR / GREAVES COTTON
41S&F in renewal Shut down valve solenoidsuitable for all capacities of DG set complete all as specified and directed.
42S&F in renewal Thermostatof suitable for all capacities of DG set complete all as specified and directed.
43S&F in renewal Diaphramg couplingfor DG set upto 62.5 KVA capacity complete all as specified and directed.
44S&F in renewalHose Sil D100 X 90for DG set upto 200 KVAcapacity complete all as specified and directed.
45S&F in renewal Air Cleaner Assemblyfor DG set upto62.5KVAcapacity complete all as specified and directed.
46S&F in renewal for copper Battery leadof 25 Sqmm, 2mtr longsuitable for all capacities of DG set complete all as specified and directed.
47S&F in renewal Feed pumpsuitable for all capacities of DG set complete all as specified and directed.
48S&F in renewal Injector assemblyof DG Set of capacity for 62.5KVA to200 KVA complete all as specified and directed.
49S&F in renewal V Belt / Fan beltsuitable for all capacities of DG set complete all as specified and directed.
50S&F in renewalDiesel pipe suitable for all capacities of DG set complete all as specified and directed.
51S&F in renewal Hose Flexiblesuitable for for all capacities of DG set complete all as specified and directed
52M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set capacity15 KVA to 82.5 KVAincluding overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
53Supply & fix in renewalNozzle for15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
54Supply & fix in renewal F.I.P. Elements for 15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
55Supply & fix in renewalDelivery valvefor15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
56M&L fordisconnecting, dismantling and overhauling of fuel injector pump of DG set of capacity 100 KVA to 200 KVA including repair, overhauling, calibration, testing complete and refixing to its original position properly complete all as specified and directed. Note:- FIP shall be calibrated by authorised work shop of manufacturer company Contractor has to submit documentary evidense for over hauling carried out from authorised work shop.
57Supply & fix in renewalNozzle & Holder Assemblyof DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
58Supply & fix in renewal Gear Drive Injection pump of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
59Supply & fix in renewalGasket injection pump mount of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
60Supply & fix in renewal of A.V.R suitable for20 KVA to 200 KVAcapacity DG set complete all as specified and directed. Make:-KIRLOSKAR/ AE / NATIONAL.
61M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection and supply and fixing ofnew water pump assembly suitable for DG set capacity for 40 KVA to 200 KVAincluding renewal of u/s hose pipes, fan belt, nut/bolts etc complete all as specified and directed.Make:-- KIRLOSKAR/ Cummins / GREAVES COTTON
62Supply & fix in renewalsolenoid stopper ( solenoid fuel pump ) for FIP pump of 40KVAto 200 KVA capacity DG set complete all as specified and directed. Make :--Cummins/ Kirloskar or equivalent as approved.
63Supply & fix in renewal fully automatic battery charger (input 230V AC SMPS based and out put 24V DC) for 24 voltbattery complete all as specified and directed. Make :-KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA .
64Supply & fix in renewal fully automatic battery charger (input 230V ACSMPS based and out put 12V DC) for 12 voltbattery complete all as specified and directed. Make :-KIRLOSKAR / ELECT INDIA / Cummins /UNITEK INDIA
65Supply & fix in renewalBattery- 12 Volts,180 AHfor DG set of suitable capacity complete all as specified and directed with 18 month replacement warrantty Make: EXIDE / AMARON / or equillvant as approved.
66Supply & fixing in renewalBattery- 12 Volts,150 AHfor DG set of suitable capacity complete all as specified and directed with 18 month replacement warranty. Make: EXIDE / AMARON / or equillvant
67M&L for checking of AMF panel & DG set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repair as per site requirement and checking of AMF panel andDG set for power suply from DG set through AMF panel and replacethe worn out parts of AMF panel & DG setbyexpert engineer complete all as specified and directed.Notes :- Note:(a) Replaced worn out parts of AMF panel/DG set shall be measured and paid separately under relevant items of schedule "A".(b) Charges for detectingthe fault in AMF Panel/electric system/DG set are included in the quoted item rate.
68M & L for shifting of trolly mounted DG set up to 250 KVA from one location to another location (with in 05 kilometer) complete including after disconnection of cable connection, earth strip including transportation with using necessary chain pulley & HYDRAULIC jack etc including necessary cable connection and earth strip and other etc. at new location complete all as specified and directed.
69S & F in renewal Genset Controller Panel suitable upto 125 KVA capacity DG Set, make and model of Genset controller panel shall beas per site or directed by Enginer -in- charge
70S & F in renewalGenset Controller Panel suitable DG Set of capacity 125 to 320 KVA make and model Genset controller panel shall be as per site or directed by Enginer -in- charge
71Supply & fixin replacementDigital Frequency meter, 96 Sqmm .Make: AE/ NationalOREquivalent as approved.
72Supply & fix in replacementIndicater lamp with holder set of three colours ofR,Y & B (LED type) suitable for DC/AC supply.
73Supply & fix in replacementRelay-24 VDC/ 12 VDC / 220 VAC / 240 VACfor AMF panel of DG set. Make: CUMMINS( AX1012821 ) / OMRON / SALZER / PLA OREquivalent as approved .
74Supply & fix in replacementContactor- 3/4 Pole,150 Amps/ 140 AMPSfor 62.5KVA capacity DG Set AMF panel includingreplacement of lugs and checking of all connections etc.Make:- LEGRAND ( 4162 66) /L &T/ SCHNEIDER / C & S .
75Supply & fix in replacement Contactor- 3/4 Pole, 225 Amp/ 200 Ampfor 125 KVA capacityDG set AMF panel includingreplacement of lugs and checking of allconnections etc.Make:- LEGRAND ( 4162 96 ) /L &T / SCHNEIDER / C & S .
76Supply & fix in replacement Contactor of 4 Pole, 250 Ampsfor AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc. Make:-SCHNEIDER ( LC1F1504 ) /L &T / C & S .
77Supply & fix in replacement Spare Contact Kit for Contactor-250 Amps suitable for 100 KVAto 125 KVA capacity DG set.Make:- L & T ( CS94084) / SCHNEIDER / C & S .
78Supply & fix in replacementMCCB, 200 Amp, 4 pole, 36 KA , 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed. Make:-L & T ( CM94153OOOOAG ) / Legrand /HAVELLS .
79Supply & fix in replacement Selector Switch four position.Make: Automation Electronics / SCIOREquivalent as approved.
80Supply & fix in replacement Self Engine Stop Relay Device for 63 KVA to 180 KVA capacity DG set AMF panel . Make:Automation Electronics / Elect India or equivalent as approved.
81Supply & fix in replacement AMF Controller device for Auto/ Manual functionfor 200 KVA to 500 KVA capacity DG set. Make: Automation Electronics / ELECT INDIAOREquivalent as approved.
82Supply & fix in replacement Solenoid stopper ( Solenoid Fuel Pump ) upto 125 KVA capacity DG set . Make:--Cummins ( 3928160 ) /Kirloskar /orEqivalent as approved.
83M & L for dismantling of defective water pump assembly by disconnecting hose pipe connections, fanbelt, radiator connection. Supply and fix new water pump assembly suitable for DG set capacity for 100 KVA to 200 KVAincluding all connection replacement of u/s hose pipes, fan belt, nut/bolts etc.Make:-- Kirloskar ( KL6.176.05.0.00 ) / Cummins orEqivalent as approved.
84Supply & fix in replacement Electronic Timer, auxilary supply-240 VAC/24 VDC for 125 KVA to 200 KVA DG set. Make: AE/ EAPL / MINILEC
85Supply & fix in replacementUndervolt/overvolt relay-ON/OFF delay time (1 to 15 sec ),sensing supply 415 Volt for 63 KVA to 400 KVA capacity DG set. Make-AE/PIC / MINILEC
86Supply & fix in replacementChangeover switch (Open Execution, Front operated) of 200 Amps, 4 Pole, 415 V, 50 Hz. Make: HPL ( BP04004POAV ) /HAVELLS.
87Supply & fix in replacementOFF-Load Changeover switch (Side Handle) of 160 Amps, 4 Pole, 415 V, 50 Hz. Make: HAVELLS/ HPL or equivalent as approved.
88Supply & fix in replacementRectifier Assembly for 40 KVA to 160 KVA capacity DG set.Make:KIRLOSKAR ( KV280108000) / CUMMINS OREquivalent as approved.
89Supply & fix in replacement Set of Forword and Reverse Diode for 40 KVA to 160 KVA capacityDG set Make:KIRLOSKAR ( F681539000 ) / CUMMINS OREquivalent as approved .
90Supply & fix in replacementRocker housing assembly suitable for 160 KVA capacity DG Set . MAKE: CUMMINS ( 3044788 )OR equivalent as approved .
91Supply & fix in replacement of Three Phase Multifunction Digital meter .Make: Automation Electronics / HPL / National
92Supply & fix in replacementAMF Relay Box for Auto/ Manual function including voltage monitor system and fully auto and manual system for 63 KVAto 110 KVA capacity DG set.Make: AE/ ELECT INDIAOR equivalent as approved.
93Supply & fix in replacement Tube injector fuel supply for 100 KVAto 200 KVA capacity DG set. Make: CUMMINS ( 3964706 ) / KIRLOSKAR or equivalent as approved
94Supply & fix in replacement CONTROL GOVERNOR ( MECHANICAL GOVERNOR )for160 KVA capacity DG set. Make: CUMMINS ( 3037359 ) or equivalent as approved.
95M & L forrepairingPT pump complete with replacement of drive accessories, plunger and barrel, weight/courier,oil sheets etc including machinery work for 125 KVA to 160 KVA capacity DG set complete all as specified and directed. Note :- PT pump shall be calibrated by authorised workshop of manufacturer company Contractor has to submit documentary evidense for the repairing carried out from the authorised workshop.
96Supply & fixshaft governor weight (3006718) for repairing of PT pump for 125 KVA to 160 KVA capacity DG Set complete all as specified and directed.
97Supply & fixingoil seal (3006738) for repairing of PT pump for 125 KVA to 160 KVA capacity DG Setcomplete all as specified and directed.
98Supply & fixing gasket set fuel pump (3010242)for repairing of PT pump for 125 KVA to 160 KVA capacity DG Set complete all as specified and directed.
99M & L for dismantlingturbo charger of DG set engine ofcapacity 100 KVA to 200 KVAincluding repair, overhauling, testing complete and fixing to its original position properly complete all as specified and directed:--
100S&F in repair Kit Turbo (KIT3801101) for repairing of Turbo charger of the DG setcapacity 100 to 200 KVA complete all as specified and directed.
101S&F in repair sleeve turbocharger (216802) for repairing of Turbo charger for the DG Set of capacity 100 to 200 KVAcomplete all as specified and directed.
102M & L for dismantling andreplacement of Injector assembly (3239796) for the DG set of capacity 62.5KVA to200 KVAcomplete all as specified and directed.
103Taking out alternator of DG Set of capacity 125 KVA to 200 KVA of any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
104M&L for Field coil rewinding of alternator of 125 KVA to 200 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
105Taking out alternator of 62.5 KVA to 100 KVA capacity DG sets of any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
106M&L for field coil rewinding of alternator of 62.5 KVA capacity to 100 KVA capacity DG sets of any make,rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
107Taking out alternator of 20 KVA to 50 KVA capacity DG sets of any make including materials and labour for, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
108S&F MCCB 4 Pole Thermal adjustable breaker type of following capacity etc complete all as specified and directed
10963 AMP, 16 KA
110125 AMP, 25 KA
111160 AMP, 25 KA
112200 AMP, 25 KA
113Supply and Fix or lay in replacement Copper lead single core PVC insulated and sheathed multi stranded copper conductor cable of cross sectional area 16 sqmm laid in trenches or fixed on wall / floor/ poles etc complete all as specified and directed.
114Supply and Fix or lay in replacementCopper lead single core PVC insulated and sheathed multi stranded copper conductor cable of cross sectional area 25 sqmm laid in trenches or fixed on wall / floor/ poles etc complete all as specified and directed.
115Supply and fix in renewal factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 62.5KVA capacity DG Set, fabricated by using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply including, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No.(ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No. (iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load.(vi) Transformer of adequate rating. (vii) Ractifiers
116(viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacityand 2 Nos,MCCB 4 pole, 100 Amp, 25 KA, thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
117Supply and fixfactory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 40 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply including, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No.(ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No. (iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load.(vi) Transformer of adequate rating.
118(vii) Ractifiers (viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacityand 2 Nos,MCCB 4 pole, 100 Amp, 25 KA, thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
119Supply & Lay and testing XLPE PVC insulated and sheathed LTUG cable, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor cross sectional area 120 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
120Supply & Lay and testingXLPE PVC insulated and sheathed LTUG cable, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor cross sectional area 95 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
121Supply & Lay and testing XLPE PVC insulated sheathed LTUG cable, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 70 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid intrenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
122Excacation in trenches in soft/loose soil n. exc 1.5 m wide and n. exc. 1.5 m in depth for laying cables and etc complete all as specified and directed.
123Return filling in including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft/loose soil after cable are laid and tested complete all as specified and directed.
124Removing excavated surplus (soil) to a distance n. exc. 50m and deposited where directed at a level n. exc.1.5m above the starting point complete all as specified and directed.
125M&L for sand filing with clean dry fine river sand unsashed including gently punning around cables in trenches for cable protection complete all specified and directed. Note : punned thickness shall be measused and paid.
126Supply & Laying sub class "B" bricks (old size) with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail