Tender For Repair/Maintenance Of Vcb , Rmu, Transformer , Isolation Transformer , Servo Voltage Stabilizer And Connected Works At Af Station Bihta, bihta-Bihar

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Vcb , Rmu, Transformer , Isolation Transformer , Servo Voltage Stabilizer And Connected Works At Af Station Bihta. Submission Date for this Tender is 23-03-2023. Voltage Stabiliser Tenders in bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

36266392
Corrigendum : Tender For Repair/Maintenance Of Vcb , Rmu, Transformer , Isolation Transformer , Servo Voltage Stabilizer And Connected Works At Af Station Bihta
Open Tender
Indian
Bihar
bihta
23-03-2023

Tender Details

Tender For Repair/Maintenance Of Vcb , Rmu, Transformer , Isolation Transformer , Servo Voltage Stabilizer And Connected Works At Af Station Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Feb-2023 Amendment No 01 Other 11-03-2023
2 28-Feb-2023 BOQ Amendment No 01 BOQ 11-03-2023
3 28-Feb-2023 Critical date Date 11-03-2023
4 11-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-03-2023
5 18-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR/MAINT OF VCB , RMU, TRANSFORMER , ISOLATION TRANSFORMER , SERVO VOLTAGE STABILIZER AND CONNECTED WORKS AT AF STATION BIHTA
Sl. No. Item Description
1complete servicing of VCB Make : Siemens installedat Air force station Bihta by using requiredT & Pincluding taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF,instant tripping on faultincluding testing with required instruments as per secondary injection method complete all as directed by Engr-in-Charge.The servicing covers the following :- (a)Through cleaning of breaker chamber (b)Lubrication of shutter mechanism/moving parts (c)Checking of shutter movement (d)Checking door interlocks with breaker (e)Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the panel. (g)Coiling of closing and tripping coil (h)Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k)Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking healthiness of three poles. (n)Checking of damping device and setting. (o)Tightness, checking of power connection. (p)Checking of breaker ON/OFF operation manually and electrically.
2(q)Checking of closing timings. (r)Checking of tripping timings. (s)Functional checking of all electrical and mechanical operation of brekers. (t)Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record. (g)Checking/replacement of non functional strip heaters inside the VCBs and allied works. Note:The breaker shall be repaired through authorised dealer or representative of Original Equipment manufacturer of VCB. Location : VCB ( Make : SIEMENS ) installed at Radar Sub Station - 02 Nos, OPS Sub Station No 5 - 02 Tropo Sub Station - 06 Nos, VCB (Make: ABB) installed at Sub Stn No 1.-02. Radar Sub Stn- 03Nos , Ops Sub Stn No 5 - 03 Nos Note :(a)Spare parts required for repair of VCB shall be measured and paid S & F under relevant items herein after ser No 2 to 27.(b)After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of AGE E/M GE (AF) BIHTA showing all functional/operational system are working satisfactorily.
3S & F of Spring Drum complete as specified as per OEM instruction. Cat part No 1VYN300950-20 co
4S & F of Stop Washercomplete as specified as per OEM instruction. Cat part No GCE7006075P0101
5S & F of Cam Disccomplete as specified as per OEM instruction. Cat part No GCE7001923P0101
6S & F of LockingRollercomplete as specified as per OEM instruction. Cat part No1VYN400950-164
7S & F of Torsion Springcomplete as specified as per OEM instruction. Cat part No 1VYN400950-002
8S & F of Charging Levercomplete as specified as per OEM instruction. Cat part No 1VYN400950-114
9S & F of Roller Bearing complete as specified as per OEM instruction. Cat part No 1VYN400950-077
10S & F of TorsionSpring complete as specified as per OEM instruction. Cat part No 1VYN400950-010
11S & F of LeverAssemblycomplete as specified as per OEM instruction. Cat part No 1VYN400901-R
12S & F of Shaftcomplete as specified as per OEM instruction. Cat part No 1VYN300950-013
13S & F of ControlWashercomplete as specified as per OEM instruction. Cat part No GCE7001917P0101
14S & F of Motor - 220V DC/AC complete as specified as per OEM instruction. Cat part No 1VYN300951-002 (GCE0940084P0106)
15S & F ofMotor Cut Off Switch complete as specified as per OEM instruction. Cat part No HAGT444559P2
16S & F of SprocketWheel complete as specified as per OEM instruction. Cat part No 1VYN400950-208
17S & F of Ratchet Plate complete as specified as per OEM instruction. Cat part NoGCE9478400P0101
18S & F of On-Off Indicator (Display)complete as specified as per OEM instruction. Cat part No GCE7001910P0101
19S & F of Shaft complete as specified as per OEM instruction. Cat part No 1VYN300950-030
20S & F of Tripping/Closing Coil-110V DC complete as specified as per OEM instruction. Cat part No 1N54450007-M
21S & F ofPin Plug Assemblycomplete as specified as per OEM instruction. Cat part No IN26570001-AM
22S & F of Emergency Trip Assembly complete as specified as per OEM instruction. Cat part NoIVYN400901-AF
23S & F of Connection Piececomplete as specified as per OEM instruction. Cat part No 1VYN400950-204
24S & F ofAux. Switchcomplete as specified as per OEM instruction. Cat part No 1VYN300950-064
25S & F ofContact System For VD4-630 A (12 Finger) complete as specified as per OEM instruction. Cat Part No. GCE8385888R0102
26S & F ofAlu.Contact Arm Assly.For VD4 CB(800A) complete as specified as per OEM instruction. Cat part No GCE700142R0119
27S & F of Cu.Contact Arm Assly.VD4 CB complete as specified as per OEM instruction. Cat part No GCE7001421R0101
28S & F ofContact System For VD4-1250 A(DIA.34 &24 Finger) VD4 complete as specified as per OEM instruction. Cat part No GCE8385888R0101
29S & F in replacement of sleeved copper bus bar 800Amps for interconnection between siemens -3 Nos breakers+ 1 No bus couplerincluding replacement of suitable size of steel nuts, bolts & washers etc complete all as specified and as directed.
30S & F in replacement of Racking trey stand of suitable size for racking of VD4 breaker In/Out.The size of racking shall be as per manufacturers instruction and complete all as specified and as directed.
31S & F in replacement of space heater 0.5KW, 230v AC suitable for VCB alongwith suitable size of thermostat for instant tripping complete all as specified and as directed.
32Complete servicing of Existing RMU (Make : ABB) installed at various 11 KV Sub Stations at AF Stn Bihta by using requiredT & Pincluding taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF,instant tripping on faultincluding testing with required instruments complete all as directed by Engr-in-Charge.The servicing covers the following :-
33(a)Through cleaning of breaker chamber (b)Checking of closing and tripping coil (c)Checking of Test/service Aux. switch operation (d)Checking of tripping mechanism operation. (e)Spring charging limit switches operation. (f) Checking healthiness of three poles. (g)Tightness, checking of power connection. (h)Checking of breaker ON/OFF operation manually and electrically. (j) Checking of closing timings. (k)Checking of tripping timings. (l)Functional checking of all electrical and mechanical operation of breakers. (m)Co-ordination of relay and their testing with required testing equipment according to source incomer VCB. Note:The breaker shall be repaired through authorised dealer or the representative of OEM manufacturer of ABB. Location : Sub Stn No 2, ATC Sub Stn, TC P/H Sub Stn & Sub Stn No 5 Note :(a)Spare parts required for repair of RMU shall be measured and paid under relevant items herein after ser No 32 to 45.(b)After completion of repair work, RMU shall be connected to full load and testing to be carried out infront of AGE E/M GE (AF) BIHTA showing all functional/operational system are working satisfactorily.
34S & F in replacement of Bushing 400 Series Bolted Type complete as specified as per OEM instruction. Cat part No NHP201699R1 Make : ABB
35S & F in replacement of O" Ring 72x6 Bushing 400 series boltedcomplete as specified as per OEM instruction. Cat Part No NHP402076P15 Make : ABB
36S & F in replacement of Trip coil safeo force Amplifier Cat No 1VDP000142R1 Make : ABB
37S & F in replacement of VPIS unit, 9-15 kv type, complete as specified as per OEM instruction. Cat No YN1V400916-587Make : ABB
38S & F in replacement of Relay complete as specified as per OEM instruction. Make : Ashida Cat No 4200013670
39S & F in replacement of digital COS? Meter ,C.l-1.0,Aux.Supply- 80-240V AC/DC complete as specified as per OEM instruction. Make –Conzerv
40S & F in replacement of digital Ampere Meter ,C.l- 1.0. Aux.Supply- 80-240V AC/DC complete as specified as per OEM instruction. Make –Conzerv
41S & F in replacement of digitalVolt Meter ,C.l- 1.0. Aux.Supply- 80-240V AC/DC complete as specified as per OEM instruction. Make –Conzerv
42S & F in replacement of Numerical O/C & E/F Relay , Aux.Supply- 80-240V AC/DC. CT- 5-1A complete as specified as per OEM instruction. Cat part No ADR141C
43S & F in replacement of VAA 33 Aux.3 Element Relay ,Aux.Supply 30V DC,06 ON Contacts complete as specified as per OEM instruction.
44S & F in replacement of VAJH13 Master trip relay ,Make- Alstom, Aux.Supply 30V DC.04 ON Contacts & 01NC Contacts complete as specified as per OEM instruction.
45S & F in replacement of damaged/unsv CT of Ratio – 60/5+5A,VA-7.5VA,5P10,C.l-1.0 complete as specified as per OEM instruction. Make- NPP,Power Foil,
46S & F in replacement of damaged 3 Phase PT of ratio – 11KV/110V ,VA-100,C.l-1.0. suitable for existing model RMUcomplete as specified as per OEM instruction. Make- NPP,Power Foil.
47S & F in replacement of Bus bar insulator as per existing size model.suitable for HT 11000 volts complete as specified as per OEM instruction.
48Supply, laying, testing and commisioning HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts (Earthed) grade cross sectional area 95 Sqmm 3 core including all electrical connections complete all as specified and directed. Note :- Excavation, earth work sand cushioning, cable protection cover/pipe, joint and cable indicator shall be measured and paid for separately under respective item of this schedule of work.
49M & L forGODswitch,Material and labour for switch Air break gang operated triple pole mechanically operated vertical type 12 insulators and with galvanized frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 200 Amps 11000 Volt with nut bolt and washers etc including taking down of old UNSV GOD complete all as specified and as directed.
50Cable jointing kit suitable for 11 KV (Earthed) grade cable outdoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sq mm complete all as specified and directed.
51Cable jointing kit suitable for 11 KV (Earthed) grade cable indoor termination, heatshrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sq mmcomplete all as specified and directed.
52Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
53Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
54Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified.
55Labour for re-laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified.
56M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified.
57Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Engineer-in-Charge. Note :-Punned thickness shall be measured.
58M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit /foundation /any other means etc complete all as specified and as directed by Engr-in-Charge.
59M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate mechanically crushed stone for mass filling in stay pits and foundation /any other means complete all as specified and as directed by Engr-in-Charge.
60Supply & fixing in replacement for 50mm bore GI tubing light grade, on poles, under floors, road crossing etc all as reqd at site complete all as specified and as directed by Engr-in-Charge.
61Supply & fixing in replacement for 80mm bore GI tubing light grade, on poles, under floors, road crossing etc all as reqd at site complete all as specified and as directed by Engr-in-Charge.
62Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the same XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 11000 volts connecting and testingcomplete all as specified and as directed by Engr-in-Charge. Note: (Excavation,earth work, brick protection sand cushioningand GI pipe etc shall be measured & paid for separately)
63M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawing including taking out the old one.Note -(i) Cost of GI strip and GI protection pipe up to a distance 7.5 M shall be includedin quoted rate of this Items. (ii) Required earth work shall be included in this item.