Development Of Distribution Infrastructure At Malappuram District (Electrical Circle Manjeri, Electrical Circle Tirur & Electrical Circle Nilambur)Of Kerala Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Boq For Plant And Equ, tirur-Kerala

Kerala State Electricity Board-KSEB has published Development Of Distribution Infrastructure At Malappuram District (Electrical Circle Manjeri, Electrical Circle Tirur & Electrical Circle Nilambur)Of Kerala Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Boq For Plant And Equ. Submission Date for this Tender is 24-02-2023. Cutting Crimping and Punching Tools Tenders in tirur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

36256460
Development Of Distribution Infrastructure At Malappuram District (Electrical Circle Manjeri, Electrical Circle Tirur & Electrical Circle Nilambur)Of Kerala Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Boq For Plant And Equ
Open Tender
Indian
Kerala
tirur
24-02-2023

Tender Details

Development Of Distribution Infrastructure At Malappuram District ( Electrical Circle Manjeri, Electrical Circle Tirur & Electrical Circle Nilambur ) Of Kerala Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme ( Boq For Plant And Equipment ) -Boq - 1 -11 Kv Line Using 3 X 300 Sq Mm Xlpe Ug Cable 2 Supply Of 11 Kv Ug Cable Of Size 3X 300 Sqmm 3 Hdpe Pipepn 6 Configuration And Pe Grade 80 4 110 Mm 5 150Mm 6 Class B4.8 Mm Thick Gi Pipe 7 150 Mm 8 110 Mm 9 Heat Shrinkable Cable End Termination Kit Suitable For 3 X 300 Sqmm Ug Cable 10 Outdoor Type 11 Heat Shrinkable Straight Joints Using Shear Bolt Type As Per Is 13573 Part Ii 2011 With Dual Wall And Single Triple Extruded Hybrid Tubing With Shear Bolt Connector As Per Iec 61238, Of Rating 300 / 400 A 12 Poles For The Construction Of Dps / Cut Pole 13 Psc Poles 9M- 487 Kg 14 Galvanized A Poles 11 M ( Hot Dip Galvanized ) 15 Prefabricated Materials Like Cross Arms, Clamps, Bolts And Nuts, Gi Wire Of Size6 Swg, Gi Strip Of Size 25 X 3Mm Etc 16 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 17 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 18 Earth / Groundenhancementmaterial 19 Properly Cured Reinforced Concrete Slabs Of Size 40 X 30 X 5 Cm , 1 : 1.5 : 3Cement Concrete With6mm Baby Metal Using 6 Mm Tmt At 10 Cm C / C -With Markings As Specified 20 Cable Route Markeras Per Specification 21 Station Classpolymer Type La, 9 Kv, 10 Ka With All Accessories 22 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 23 Rdss Sign Board As Per Specifications 24 Hot Dip Galvanized Stay Set With Anchor Plate Size 300X300x10mm, 50 / 8Mm Stay Clamp, Stay Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 25 Boq-2 - 11 Kv Aerial Bunched Cables 26 Poles For 11 Kv Abcline As Per Technical Specifications Approved Works And As Per Drawing. 27 Psc Pole 9M- / 487 Kg 28 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 29 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 30 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 31 A Pole 13 M -- Do - Horizontal Ties Isa 65X65x6mm; 32 Supply Of 11Kv Abc As Per Technical Specification And Scope Of Work. 33 3X150+1X120sqmm ( Insulated Messenger ) 34 3X120+1X95sqmm ( Insulated Messenger ) 35 Single Core Removable And Re Usable Tee For 11Kv Abc ( Mvt ) ( Set Of 3Nos ) 36 Special Channel Cross Arm For Fixing The Mvt, La With Bolt And Nuts, Earthwireetc. 37 11Kv End Termination Kits 38 Suitable For 150Sqmm 39 Suitable For 120Sqmm 40 Abc Accessories 41 Heat Shrinkable Tube 42 Anchor Clamp Or Dead End Clamp Suitable For Ht Abc 43 Suspension Clamp Suitable For Ht Abc 44 Stainless Steel Strap 45 Stainless Steel Buckles 46 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 47 Ligthning Arrester 48 9Kv 10Kamps Polymeric Surge Arrester Station Classs ( 3Nos Per Set ) 49 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 50 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 51 Earth / Groundenhancementmaterial 52 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 53 Galvanized Stay Set With Anchor Plate Size 300X300x10mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Stranded Wire As Per Technical Specifications , Scope Of Works And As Per Drawing. 54 Rdss Sign Board As Per Specifications 55 Pre-Fabricated Gi Channel Cross Arm, Bracket, Clamps, Galvanised Nuts, Bolts With Spring Washers Etc As Per Technical Specification, 56 Polymeric Insulator With Accesoeries 57 11Kv 45 Kn, Polymeric Disc Insulators With Hardware Fittings 58 11Kv Polymeric Pin Insulator With Gi Pin 59 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 60 Boq - 3 - 11 Kv Reconductoring Using Covered Conductor 61 Poles For 11 Kv Oh Line As Per Technical Specifications Approved Works And As Per Drawing. 62 Psc Pole 9M- / 487 Kg 63 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 64 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 65 Prefabricated Itemsv Cross Arm ( 10.75Kg / Each ) , Pole Top F Clamp ( 1.5Kg / Each ) , Double C Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Including Back Clamp, Etc Made Of Gi Channels, Angle, Flats Of Given Sizes For Over Head Structures, Gi Strip 25 X 3Mm, Gi Strip 25 X 6 Mm, 8 Swg Gi Wire, 6 Swg Gi Wire Etcas Per Technical Specification, Approved Drawings And Scope Of Work. 66 Ms Bolts And Nuts With Washers 67 Galvanized Stay Set With Anchor Plate Size 300X300x 10 Mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20 Mm Dia Solid Gs Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 68 Polymeric Insulator With Accessories 69 11Kv 45 Kn, Polymeric Disc Insulators With Anchoring Clamp 70 11Kv Polymeric Pin Insulator With Gi Pin 71 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 72 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 73 Earth / Groundenhancementmaterial 74 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 75 11Kvcovered Conductor With Following Types 76 99 Sqmm Aaac / Acsr Ht Covered Conductor 77 Covered Conductor Accessories 78 Insulated Piercing Connector For Bare To Insulated Connection 79 Mechanical Connector With Heat Shrink Sleeve For Bare To Insulated Connection 80 Insulated Piercing Connector For Branching ( Ipc - Type 2 ) 81 Insulated Piercing Connector With Al Bail For Earthing ( Maintenance Earthing Ipc-Type3 ) 82 Heat Shrinkable End Cap 83 Mid Span Joint For Cc 84 Uv Resistant Insulated Cable Tie 85 9 Kv, 5 Ka Distribution Class La 86 Rdss Sign Board As Per Specifications 87 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 88 Fuse Unit Withbackalite / Frp Base 100 A 89 Pvc Plastic Tie 90 Mid Span Joint With Heat Shrinkable Sleeve 91 Ipc For Cc 92 New Pvc Alweather Proof Cable For Service Connection 93 2 C 2.5 Sqmm 94 4 C 16 Sqmm 95 Boq4 - Reconductoring 11Kv Lines Withabc 96 Poles For 11 Kv Abcline As Per Technical Specifications Approved Works And As Per Drawing. 97 Psc Pole 9M- / 487 Kg 98 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 99 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 100 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 101 A Pole 14 M 14M Vertical Member Isa 100X100x8mm -- Diagonal Tie 50X50x8mm; Horizontal Ties Isa 65X65x6mm;Bottom Support Horizontal Ties- 580 Mm 102 Supply Of 11Kv Abc As Per Technical Specification And Scope Of Work. 103 3X150+1X120sqmm ( Insulated Messenger ) 104 3X120+1X95sqmm ( Insulated Messenger ) 105 Single Core Removable And Re Usable Tee For 11Kv Abc ( Mvt ) ( Set Of 3Nos ) 106 Special Channel Cross Arm For Fixing The Mvt, La With Bolt And Nuts, Earthwireetc. 107 11Kv End Termination Kits For 3Phase 108 Suitable For 150Sqmm 109 Suitable For 120Sqmm 110 Abc Accessories 111 Heat Shrinkable Tube 112 Anchor Clamp Or Dead End Clamp Suitable For Ht Abc 113 Suspension Clamp Suitable For Ht Abc 114 Stainless Steel Strap 115 Stainless Steel Buckles 116 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 117 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 118 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 119 Earth / Groundenhancementmaterial 120 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 121 Lightning Arrestor 122 9 Kv, 5 Ka, Distribution Class La 123 9 Kv, 10 Ka, Station Class La 124 Galvanized Stay Set With Anchor Plate Size 300X300x 10 Mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20 Mm Dia Solid Gs Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 125 Rdss Sign Board As Per Specifications 126 New Pvc Alweather Proof Cable For Service Connection 127 2 C 2.5 Sqmm 128 4 C 16 Sqmm 129 4 C 25 Sqmm 130 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 131 Fuse Unit With Base 100 A 132 Gi Strip 25 X 3Mm, Gi Strip 25 X 6 Mm, 8 Swg Gi Wire, 6 Swg Gi Wire Etc 133 Pre-Fabricated Gi Channel Cross Arm, Bracket, Clamps, Galvanised Nuts, Bolts With Spring Washers Etc As Per Technical Specification, 134 Boq - 5 - 11 Kv Reconductoring Using Bare Oh 135 Support Pole For 11 Kv Oh Line As Per Technical Specifications Approved Works And As Per Drawing. 136 Psc Pole 9M- / 487 Kg 137 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 138 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 139 Prefabricated Items Likes V Cross Arm ( 10.75Kg / Each ) , Pole Top F Clamp ( 1.5Kg / Each ) , Double C Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Including Back Clamp, Etc Made Of Gi Channels, Angle, Flats Of Given Sizes For Over Head Structures, Gi Strip 25 X 3Mm, Gi Strip 25 X 6 Mm, 8 Swg Gi Wire, 6 Swg Gi Wire Etc As Per Technical Specification, Approved Drawings And Scope Of Work. 140 Ms Bolts And Nuts With Washers And Stud 141 Galvanized Stay Set With Anchor Plate Size 300X300x 10 Mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20 Mm Dia Solid Gs Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 142 Polymeric Insulator With Accesoeries 143 11Kv 45 Kn, Polymeric Disc Insulators With Hardware Fittings 144 11Kv Polymeric Pin Insulator With Gi Pin 145 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 146 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 147 Acsr Conductor With Following Types 148 Ascr Racoon 149 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 150 Rdss Sign Board As Per Specifications 151 Abc Accessories 152 New Pvc Alweather Proof Cable For Service Connection 153 2 C 2.5 Sqmm 154 Boq - 6 -Lt Reconductoring Using Abc 155 Supply Of Poles As Per Specification And Scope Of Work 156 8 M Long / 380 Kgs Psc Poles 157 9 Meter Long / 487 Kg Psc Poles 158 A Type Pole, 10M - Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 159 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 160 3X95+1X70+1X16sqmm ( Insulated Messenger ) 161 3X70+1X50+1X16sqmm ( Insulated Messenger ) 162 Supply Of Abc Accessories 163 Abc To Abc T Connector 164 Abc To Abc Mid Span Joint ( Straight Joint ) 165 Satellite Connectors For Multiple Service Connection. 166 Ipc For Service Connection 167 Ipc For Abc To Db Connection 168 Ipc For Abc To Bare Conductor 169 Lt Distribution Box Suitablefor Single Phase And Three Phase Service Connection 170 Heat Shrinkable Tube 171 End Cap As Per Cable Size 172 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 173 Suspension Clamp Suitable For Lt Abc 174 Stainless Steel Strap 175 Stainless Steel Buckles 176 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 177 Bimetal Crimp Lug As Per The Cable Size 178 Nut & Bolt For Lug M12x40mm Brass 179 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 180 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 181 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 182 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 183 Earth / Groundenhancementmaterial 184 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamp, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 185 3.5Cx25sqmm Xlpealuminium Cable 186 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 187 Rdss Sign Board As Per Specifications 188 70 Sqmm 1 C Xlpe Cable 189 Fuse Unit Withbackalite / Frp Base 190 63 A 191 100 A 192 200 A 193 New Pvc Alweather Proof Cable For Service Connection 194 2 C 2.5 Sqmm 195 4 C 16 Sqmm 196 4 C 25 Sqmm 197 Boq - 7 - Lt Reconductoring Using Bare Oh 198 Supply Of Poles As Per Specification And Scope Of Work 199 8 M Long / 380 Kgs Psc Poles 200 9 Meter Long / 487 Kg Psc Poles 201 Prefabricated Items Likes 2 Line Cross Arm, 4 Line Cross Arms, Clamps, Gi Wire, Bolt And Nut, Washers Etc As Per Specifications And Scope Of Work. 202 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamps, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Diagi Wire, Thimble & Guy Grip ( Black Colour ) As Per Specification And Scope Of Work 203 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 204 Lt Shackles Set 205 Ltpin Insulator With Gi Pin 206 Earth Knobfor Neutral Line And Providing Earth 207 Aluminium Bail Clamp 208 Dead-End Rabbit 209 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 210 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 211 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 212 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 213 Acsr Conductor With Following Sizes For Oh And Jumpers With Binding Materials Etc. 214 Acsr Rabbit 215 Line Spacers 216 300Mm 217 450Mm 218 Rdss Sign Board As Per Specifications 219 Fuse Unit Withbackalite / Frp Base 220 100 A 221 200 A 222 New Pvc Alweather Proof Cable For Service Connection 223 2 C 2.5 Sqmm 224 4 C 16 Sqmm 225 4 C 25 Sqmm 226 Boq - 8 - Installation Ofnew Lt Abc Of Sizes 3X95+1X70+1X16sqmm ( Insulated Messenger ) And 3X70+1X16sqmm ( Insulated Messenger ) 227 Supply Of Supporting Poles For Constructing New Lt Abc Lines 228 8 M Long / 380 Kgs Psc Poles 229 9 Meter Long / 487 Kg Psc Poles 230 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 231 3X95+1X70+1X16sqmm ( Insulated Messenger ) 232 3X70+1X50+1X16sqmm ( Insulated Messenger ) 233 Supply Of Abc Accessories 234 Abc To Abc T Connector 235 Abc To Abc Mid Span Joint ( Straight Joint ) 236 Satellite Connectors For Multiple Service Connection. 237 Ipc For Service Connector 238 Ipc For Abc To Db Connection 239 Ipc For Abc To Bare Conductor ( Two-Bolted ) 240 Lt Distribution Boxsuitable For Single Phase And Three Phase Service Connection 241 Heat Shrinkable Tube 242 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 243 End Cap As Per The Cable Size 244 Suspension Clamp Suitable For Lt Abc 245 Stainless Steel Strap 246 Stainless Steel Buckles 247 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 248 Bimetal Crimp Lug As Pe The Cable Size 249 Nut & Bolt For Lug M12x40mm Brass 250 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 251 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 252 40Mm Dia, 3000Mm Long Class B Gi Pipe Earth Electrode , With Accessories Complete 253 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 254 Earth / Groundenhancementmaterial 255 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamps, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16 Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 256 3.5 C 25 Sqmm Unarmoured Xlpecable For Connecting Ipc To Distribution Box 257 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 258 Rdss Sign Board As Per Specifications 259 70 Sqmm 1 C Xlpe Cable 260 Fuse Unit Withbackalite / Frp Base , 100 A 261 Fuse Unit Withbackalite / Frp Base , 200 A 262 Boq - 9 - Single Phase To Three Phase Conversion Using Abc 263 Supply Of Poles As Per Specification And Scope Of Work 264 8 M Long / 380 Kgs Psc Poles 265 9 Meter Long / 487 Kg Psc Poles 266 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 267 3X95+1X70+1X16sqmm ( Insulated Messenger ) 268 3X70+1X50+1X16sqmm ( Insulated Messenger ) 269 Supply Of Abc Accessories 270 Abc To Abc T Connector 271 Abc To Abc Mid Span Joint ( Straight Joint ) 272 Satellite Connectors For Multiple Service Connection. 273 Ipc For Service Connection 274 Ipc For Abc To Db Connection 275 Ipc For Abc To Bare Conductor 276 Lt Distribution Box Suitablefor Single Phase And Three Phase Service Connection 277 Heat Shrinkable Tube 278 End Cap As Per Cable Size 279 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 280 Suspension Clamp Suitable For Lt Abc 281 Stainless Steel Strap 282 Stainless Steel Buckles 283 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 284 Bimetal Crimp Lug As Per The Cable Size 285 Nut & Bolt For Lug M12x40mm Brass 286 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 287 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 288 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 289 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 290 Earth / Groundenhancementmaterial 291 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamp, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 292 3.5Cx25sqmm Xlpealuminium Cable 293 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 294 Rdss Sign Board As Per Specifications 295 70 Sqmm 1 C Xlpe Cable 296 Fuse Unit Withbackalite / Frp Base 297 100 A 298 200 A 299 New Pvc Alweather Proof Cable For Service Connection 300 2 C 2.5 Sqmm 301 Boq -10- Single Phase To Three Phase Conversion Bare Oh 302 Supply Of Poles As Per Specification And Scope Of Work 303 8 M Long / 380 Kgs Psc Poles 304 9 Meter Long / 487 Kg Psc Poles 305 Prefabricated Items Likes 2 Line Cross Arm, 4 Line Cross Arms, Clamps, Gi Wire, Bolt And Nut, Washers Etc As Per Specifications And Scope Of Work. 306 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamps, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Diagi Wire, Thimble & Guy Grip ( Black Colour ) As Per Specification And Scope Of Work 307 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 308 Lt Shackles Set 309 Ltpin Insulator With Gi Pin 310 Earth Knobfor Neutral Line And Providing Earth 311 Aluminium Parallel Groove Clamp 312 Aluminium Bail Clamp 313 Dead-End Rabbit 314 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 315 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 316 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 317 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 318 Acsr Conductor With Following Sizes For Oh And Jumpers With Binding Materials Etc. 319 Acsr Rabbit 320 Line Spacers 321 300Mm 322 450Mm 323 Rdss Sign Board As Per Specifications 324 Fuse Unit Withbackalite / Frp Base 325 100 A 326 200 A 327 New Pvc Alweather Proof Cable For Service Connection 328 2 C 2.5 Sqmm 329 Boq - 11- Installation Of New Distribution Transformer Of Capacities 100, 160, 250, 315 And 500 Kva 330 Dtr Substation Supports As Per Technical Specification, Approved Drawings And Scope Of Work 331 Psc Pole 9M- / 487 Kg 332 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 333 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 334 Prefabricated Items Likes V Cross Arm, Pole Top Bracket, Channel Cross Arm ( 3M, 2.4M ) , Clamps, 2 Line / 4 Line Cross Arm, Cross Bracings, Guarding Channels, Ms Flat Of Given Sizes, Gi Wire, Gi Strip 25 X 3Mm , Gi Strip 25 X 6Mm Etc As Per Specifications And Scope Of Work 335 Bolts & Nuts & Washers Of Various Sizes With Stud 336 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 337 Stay Set ( Galvanized ) With 50X8mm Stay Clamp, Stay Insulator ( 2 Nos ) , Anchor Plate ( 300X 300X 10 Mm ) , Nuts &Bolts, Stay Tightner / Turn Buckle, Stay Rod ( 1.8M Long, 20 Mm Dia ) , 7 / 3.15 Mmdia Gi Stranded As Per Spec And Scope Of Work. 338 Polymerinsulators With Hardware Fittings, Hardware Etc 339 11 Kv Disc Insulator With Ms Cleat And Harware Fittings 340 11 Kv Pin Insulator With Gi Pin 341 Do Fuse Unit With Support Insulators 342 Earthing Arrangement 343 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 344 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 345 Earth / Groundenhancementmaterial 346 Lightning Arrestor 347 Distribution Class Lightning Arrestor 9 Kv, 5 Ka 348 Station Class Lightning Arrestor 9 Kv, 10 Ka 349 Acsr Conductor Raccoon For Providing Drops And Jumper Connections 350 Acsr Conductor Rabbit For Providing Ltconnections 351 1.1 Kv Xlpe Insulated Unarmoured Cable For Connection Of Transformer Lv Side To Distribution Box And Distribution Box To Over Head Line As Perspec 352 1X 120 Sqmm Al Conductor Cable 353 Aluminium Socket 354 New Distribution Transformer ( Level 1 ) With All Accessories As Per Spec 355 11Kv / 433 V 100 Kva Distribution Transformer With All Accessories As Per Spec 356 Lt Distribution Box Made Of Ms Sheet Of Thickness Not Less Than 18 Swg Crca Sheet By Deep Drawn Method, Earthing Bus, Earthing Terminalfront Door Operate With Fuse Units & Proper Locking Arrangement As Per Tech.Spec 357 3 Pahse 100 Kva 2 / 3 Way Distribution Box 358 Statutory Boards 359 Rdss Sign Board As Per Specifications 360 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 361 Lt Shackles Set 362 Ltpin Insulator With Gi Pin 363 Earth Knobfor Neutral Line And Providing Earth 364 Aluminium Parallel Groove Clamp 365 Dead-End Rabbit 366 Boq-12 Enhancement Of Transformer 367 Dtr Substation Supports As Per Technical Specification, Approved Drawings And Scope Of Work 368 Psc Pole 9M- / 487 Kg 369 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 370 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 371 Prefabricated Items Likes V Cross Arm, Pole Top Bracket, Channel Cross Arm ( 3M, 2.4M ) , Clamps, 2 Line / 4 Line Cross Arm, Cross Bracings, Guarding Channels, Ms Flat Of Given Sizes, Gi Wire, Gi Strip 25 X 3Mm , Gi Strip 25 X 6Mm Etc As Per Specifications And Scope Of Work 372 Bolts & Nuts & Washers Of Various Sizes With Stud 373 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 374 Stay Set ( Galvanized ) With 50X8mm Stay Clamp, Stay Insulator ( 2 Nos ) , Anchor Plate ( 300X 300X 10 Mm ) , Nuts &Bolts, Stay Tightner / Turn Buckle, Stay Rod ( 1.8M Long, 20 Mm Dia ) , 7 / 3.15 Mmdia Gi Stranded As Per Spec And Scope Of Work. 375 11 Kv Pin Insulator With Gi Pin 376 Do Fuse Unit With Support Insulators 377 Earthing Arrangement 378 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 379 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 380 Earth / Groundenhancementmaterial 381 Distribution Class Lightning Arrestor 9 Kv, 5 Ka 382 Station Class Lightning Arrestor 9 Kv, 10 Ka 383 Acsr Conductor Raccoon For Providing Drops And Jumper Connections 384 Acsr Conductor Rabbit For Providing Ltconnections 385 1.1 Kv Xlpe Insulated Unarmoured Cable For Connection Of Transformer 386 1X 120 Sqmm Al Conductor Cable 387 1X185 Sqmm Al Conductor Cable 388 Aluminium Socket 389 New Distribution Transformer ( Level 1 ) With All Accessories As Per Spec 390 11Kv / 433 V 160 Kva Distribution Transformer With All Accessories As Per Spec 391 11Kv / 433 V250kva Distribution Transformer With All Accessories As Per Spec 392 11Kv / 433 V 315 Kva Distribution Transformer With All Accessories As Per Spec 393 3 Phase 160 Kva 3 Waydistribution Box 394 3 Phase 250 Kva 3 Way Distribution Box 395 3 Phase315 Kva 4 Way Distribution Box

Key Value

Document Fees
INR 17700 /-
EMD
INR 50000000.0 /-
Tender Value
INR 285.90 Crore /-

BOQ Items

Name of Work: DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT MALAPPURAM District (Electrical Circle Manjeri, Electrical Circle Tirur & Electrical Circle Nilambur)of KERALA UNDER REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME (BoQ for Plant and Equipment)
Sl. No. Item Description
1BOQ - 1 -11 KV line using 3 x 300 sq mm XLPE UG Cable
2Supply of 11 KV UG Cable of size 3x 300 sqmm
3HDPE PipePN 6 configuration and PE grade 80
4110 mm
5150mm
6Class B4.8 mm thick GI pipe
7150 mm
8110 mm
9Heat shrinkable Cable End Termination Kit suitable for 3 x 300 sqmm UG Cable
10Outdoor Type
11Heat shrinkable Straight joints using Shear Bolt Type as per IS 13573 Part II 2011 with dual wall and single triple extruded hybrid tubing with shear bolt connector as per IEC 61238, of rating 300/400 A
12Poles for the construction of DPs/ Cut pole
13PSC Poles 9M- 487 Kg
14Galvanized A Poles 11 M ( Hot dip Galvanized)
15Prefabricated materials like cross arms, clamps,bolts and nuts, GI Wire of size6 SWG, GI Strip of size 25 x 3mm etc
1640 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
176Kg 10 inch PVC pipe of length 30 cm withPVC end cap
18Earth/ Groundenhancementmaterial
19Properly cured Reinforced Concrete Slabs of size 40 x 30 x 5 cm , 1 : 1.5 : 3cement concrete with6mm baby metal using 6 mm TMT at 10 cm c/c -with markings as specified
20Cable Route Markeras per specification
21Station Classpolymer type LA, 9 KV, 10 KA with all accessories
2212KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
23RDSS sign Board as per specifications
24Hot dip Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, stay insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
25BOQ-2 - 11 kV Aerial Bunched Cables
26POLES for 11 KV ABCline as per technical specifications approved works and as per drawing.
27PSC pole 9M- /487 kg
28A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
29A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
30A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
31A pole 13 m -- do - Horizontal ties ISA 65x65x6mm;
32Supply of 11KV ABC as per technical specification and scope of work.
333x150+1x120sqmm(insulated messenger)
343x120+1x95sqmm(insulated messenger)
35Single core removable and re usable TEE for 11kV ABC (MVT) (Set of 3nos)
36Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc.
3711KV end termination kits
38suitable for 150sqmm
39suitable for 120sqmm
40ABC accessories
41Heat shrinkable tube
42Anchor clamp or dead end clamp suitable for HT ABC
43Suspension clamp suitable for HT ABC
44Stainless steel strap
45Stainless steel buckles
46Cable ties UV plastic heavy duty around 250mm long
47Ligthning Arrester
489KV 10KAmps polymeric surge arrester Station classs(3nos per set)
4940 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
506Kg 10 inch PVC pipe of length 30 cm withPVC end cap
51Earth/ Groundenhancementmaterial
52LT Coil for Earthing (50mm dia, 115 turns) as per specification
53Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranded wire as per technical specifications ,scope of works and as per drawing.
54RDSS sign Board as per specifications
55Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification,
56Polymeric insulator with accesoeries
5711kV 45 KN, polymeric disc insulators with hardware fittings
5811kV polymeric pin insulator with GI pin
5912KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
60BOQ - 3 - 11 kV Reconductoring using Covered Conductor
61POLES for 11 KV OH line as per technical specifications approved works and as per drawing.
62PSC pole 9M- /487 kg
63A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
64A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
65Prefabricated ItemsV cross arm(10.75kg/each), Pole top F clamp(1.5kg/each), Double C cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, including back clamp, etc made of GI Channels,angle, flats of given sizes for over head structures, GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etcas per technical specification, approved drawings and scope of work.
66MS bolts and nuts with washers
67Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
68Polymeric insulator with accessories
6911kv 45 KN, polymeric disc insulators with Anchoring clamp
7011kv polymeric pin insulator with GI pin
7140 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
726Kg 10 inch PVC pipe of length 30 cm withPVC end cap
73Earth/ Groundenhancementmaterial
74LT Coil for Earthing (50mm dia, 115 turns) as per specification
7511KVCovered Conductor with following types
7699 sqmm AAAC/ ACSR HT Covered Conductor
77Covered Conductor Accessories
78Insulated Piercing Connector for bare to insulated connection
79Mechanical Connector with heat shrink sleeve for bare to insulated connection
80Insulated Piercing Connector for branching(IPC - type 2)
81Insulated Piercing Connector with Al bail for earthing(maintenance earthing IPC-type3)
82Heat shrinkable end cap
83Mid span Joint for CC
84UV resistant Insulated Cable Tie
859 KV, 5 kA Distribution class LA
86RDSS sign Board as per specifications
8712KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
88Fuse unit withbackalite/ FRP base 100 A
89PVC Plastic tie
90Mid span joint with Heat shrinkable sleeve
91IPC for CC
92New PVC Alweather proof cable for service connection
932 C 2.5 sqmm
944 C 16 sqmm
95BOQ4 - Reconductoring 11kV lines withABC
96POLES for 11 KV ABCline as per technical specifications approved works and as per drawing.
97PSC pole 9M- /487 kg
98A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
99A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
100A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
101A pole 14 m 14m Vertical member ISA 100x100x8mm -- diagonal tie 50x50x8mm; Horizontal ties ISA 65x65x6mm;bottom support horizontal ties- 580 mm
102Supply of 11KV ABC as per technical specification and scope of work.
1033x150+1x120sqmm(insulated messenger)
1043x120+1x95sqmm(insulated messenger)
105Single core removable and re usable TEE for 11kv ABC (MVT) (Set of 3nos)
106Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc.
10711KV end termination kits for 3phase
108suitable for 150sqmm
109suitable for 120sqmm
110ABC Accessories
111Heat shrinkable tube
112Anchor clamp or dead end clamp suitable for HT ABC
113Suspension clamp suitable for HT ABC
114Stainless steel strap
115stainless steel buckles
116Cable ties UV plastic heavy duty around 250mm long
11740 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
1186Kg 10 inch PVC pipe of length 30 cm withPVC end cap
119Earth/ Groundenhancementmaterial
120LT Coil for Earthing (50mm dia, 115 turns) as per specification
121Lightning Arrestor
1229 KV, 5 KA, Distribution Class LA
1239 KV, 10 KA, Station Class LA
124Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
125RDSS sign Board as per specifications
126New PVC Alweather proof cable for service connection
1272 C 2.5 sqmm
1284 C 16 sqmm
1294 C 25 sqmm
13012KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
131Fuse unit with base 100 A
132GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etc
133Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification,
134BOQ - 5 - 11 KV Reconductoring using Bare OH
135SUPPORT POLE for 11 KV OH line as per technical specifications approved works and as per drawing.
136PSC pole 9M- /487 kg
137A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
138A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
139Prefabricated Items likes V cross arm(10.75kg/each), Pole top F clamp(1.5kg/each), Double C cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, including back clamp, etc made of GI Channels,angle, flats of given sizes for over head structures, GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etc as per technical specification, approved drawings and scope of work.
140MS bolts and nuts with washers and stud
141Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
142Polymeric insulator with accesoeries
14311kV 45 KN, polymeric disc insulators with hardware fittings
14411kV polymeric pin insulator with GI pin
14540 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
146LT Coil for Earthing (50mm dia, 115 turns) as per specification
147ACSR Conductor with following types
148ASCR Racoon
14912KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
150RDSS sign Board as per specifications
151ABC Accessories
152New PVC Alweather proof cable for service connection
1532 C 2.5 sqmm
154BOQ - 6 -LT Reconductoring using ABC
155Supply of poles as per specification and scope of work
1568 m long /380 kgs PSC Poles
1579 meter long /487 KG PSC Poles
158A Type Pole, 10m - Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
159Supply of LT ABC as per technical specification and scope of work.
1603x95+1x70+1x16sqmm(insulated messenger)
1613x70+1x50+1x16sqmm(insulated messenger)
162Supply of ABC accessories
163ABC to ABC T connector
164ABC to ABC Mid span joint (straight joint)
165Satellite connectors for multiple service connection.
166IPC for service connection
167IPC for ABC to DB connection
168IPC for ABC to bare conductor
169LT Distribution Box suitablefor single phase and three phase service connection
170Heat shrinkable tube
171End cap as per cable size
172Anchor clamp or dead end clamp suitable for LT ABC
173Suspension clamp suitable for LT ABC
174Stainless steel strap
175Stainless steel buckles
176Cable ties UV plastic heavy duty around 250mm long
177Bimetal crimp lug as per the cable size
178Nut & Bolt for LUG M12x40mm Brass
179Earthingarrangement for LT line as per technical specifications and scope of work
180LT Coil for Earthing (50mm dia, 115 turns) as per specification
18140 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
1826Kg 10 inch PVC pipe of length 30 cm withPVC end cap
183Earth/ Groundenhancementmaterial
184Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
1853.5Cx25sqmm XLPEAluminium Cable
18625 sqmmXLPE insulated single core cable for connecting to Distribution Box
187RDSS Sign Board as per specifications
18870 sqmm 1 C XLPE cable
189Fuse unit withbackalite/ FRP base
19063 A
191100 A
192200 A
193New PVC Alweather proof cable for service connection
1942 C 2.5 sqmm
1954 C 16 sqmm
1964 C 25 sqmm
197BOQ - 7 - LT Reconductoring using Bare OH
198Supply of poles as per specification and scope of work
1998 m long /380 kgs PSC Poles
2009 meter long /487 KG PSC Poles
201Prefabricated Items likes 2 line cross arm, 4 line cross arms, clamps, GI wire,bolt and nut, washers etc as per specifications and scope of work.
202Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamps, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm diaGI wire,Thimble & Guy grip (Black colour) as per specification and scope of work
203LT Insulators and hardware fittings as per specification and scope of work
204LT shackles Set
205LTpin insulator with GI pin
206Earth Knobfor neutral line and providing earth
207Aluminium bail clamp
208Dead-end Rabbit
209Earthingarrangement for LT line as per technical specifications and scope of work
210LT Coil for Earthing (50mm dia, 115 turns) as per specification
21140 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
2126Kg 10 inch PVC pipe of length 30 cm withPVC end cap
213ACSR Conductor with following sizes for OH and jumpers with binding materials etc.
214ACSR Rabbit
215Line Spacers
216300mm
217450mm
218RDSS Sign Board as per specifications
219Fuse unit withbackalite/ FRP base
220100 A
221200 A
222New PVC Alweather proof cable for service connection
2232 C 2.5 sqmm
2244 C 16 sqmm
2254 C 25 sqmm
226BOQ - 8 - Installation ofnew LT ABC of sizes 3x95+1x70+1x16sqmm(insulated messenger)and 3x70+1x16sqmm(insulated messenger)
227Supply of supporting poles for constructing New LT ABC Lines
2288 m long /380 kgs PSC Poles
2299 meter long /487 KG PSC Poles
230Supply of LT ABC as per technical specification and scope of work.
2313x95+1x70+1x16sqmm(insulated messenger)
2323x70+1x50+1x16sqmm(insulated messenger)
233Supply of ABC accessories
234ABC to ABC T Connector
235ABC to ABC Mid span joint(straight joint)
236Satellite connectors for multiple service connection.
237IPC for service connector
238IPC for ABC to DB connection
239IPC for ABC to bare conductor(two-bolted)
240LT distribution boxsuitable for single phase and three phase service connection
241Heat shrinkable tube
242Anchor clamp or dead end clamp suitable for LT ABC
243End cap as per the cable size
244Suspension clamp suitable for LT ABC
245Stainless steel strap
246Stainless steel buckles
247Cable ties UV plastic heavy duty around 250mm long
248Bimetal crimp lug as pe the cable size
249Nut & Bolt for LUG M12x40mm Brass
250Earthingarrangement for LT line as per technical specifications and scope of work
251LT Coil for Earthing (50mm dia, 115 turns) as per specification
25240mm dia,3000mm long class B GI pipe earth electrode ,with accessories complete
2536Kg 10 inch PVC pipe of length 30 cm withPVC end cap
254Earth/ Groundenhancementmaterial
255Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamps, stay insulator, stay tightner,bolt and nut, 1.8m long 16 mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
2563.5 C 25 sqmm unarmoured XLPEcable for connecting IPC to Distribution Box
25725 sqmmXLPE insulated single core cable for connecting to Distribution Box
258RDSS sign Board as per specifications
25970 sqmm 1 C XLPE cable
260Fuse unit withbackalite/ FRP base ,100 A
261Fuse unit withbackalite/ FRP base ,200 A
262BOQ - 9 - Single Phase to Three Phase Conversion using ABC
263Supply of poles as per specification and scope of work
2648 m long /380 kgs PSC Poles
2659 meter long /487 KG PSC Poles
266Supply of LT ABC as per technical specification and scope of work.
2673x95+1x70+1x16sqmm(insulated messenger)
2683x70+1x50+1x16sqmm(insulated messenger)
269Supply of ABC accessories
270ABC to ABC T connector
271ABC to ABC Mid span joint (straight joint)
272Satellite connectors for multiple service connection.
273IPC for service connection
274IPC for ABC to DB connection
275IPC for ABC to bare conductor
276LT Distribution Box suitablefor single phase and three phase service connection
277Heat shrinkable tube
278End cap as per cable size
279Anchor clamp or dead end clamp suitable for LT ABC
280Suspension clamp suitable for LT ABC
281Stainless steel strap
282Stainless steel buckles
283Cable ties UV plastic heavy duty around 250mm long
284Bimetal crimp lug as per the cable size
285Nut & Bolt for LUG M12x40mm Brass
286Earthingarrangement for LT line as per technical specifications and scope of work
287LT Coil for Earthing (50mm dia, 115 turns) as per specification
28840 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
2896Kg 10 inch PVC pipe of length 30 cm withPVC end cap
290Earth/ Groundenhancementmaterial
291Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
2923.5Cx25sqmm XLPEAluminium Cable
29325 sqmmXLPE insulated single core cable for connecting to Distribution Box
294RDSS Sign Board as per specifications
29570 sqmm 1 C XLPE cable
296Fuse unit withbackalite/ FRP base
297100 A
298200 A
299New PVC Alweather proof cable for service connection
3002 C 2.5 sqmm
301BOQ -10- Single Phase to Three Phase Conversion Bare OH
302Supply of poles as per specification and scope of work
3038 m long /380 kgs PSC Poles
3049 meter long /487 KG PSC Poles
305Prefabricated Items likes 2 line cross arm, 4 line cross arms, clamps, GI wire,bolt and nut, washers etc as per specifications and scope of work.
306Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamps, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm diaGI wire,Thimble & Guy grip (Black colour) as per specification and scope of work
307LT Insulators and hardware fittings as per specification and scope of work
308LT shackles Set
309LTpin insulator with GI pin
310Earth Knobfor neutral line and providing earth
311Aluminium parallel groove clamp
312Aluminium bail clamp
313Dead-end Rabbit
314Earthingarrangement for LT line as per technical specifications and scope of work
315LT Coil for Earthing (50mm dia, 115 turns) as per specification
31640 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
3176Kg 10 inch PVC pipe of length 30 cm withPVC end cap
318ACSR Conductor with following sizes for OH and jumpers with binding materials etc.
319ACSR Rabbit
320Line Spacers
321300mm
322450mm
323RDSS Sign Board as per specifications
324Fuse unit withbackalite/ FRP base
325100 A
326200 A
327New PVC Alweather proof cable for service connection
3282 C 2.5 sqmm
329BOQ - 11- Installation of New Distribution Transformer of capacities 100, 160, 250, 315 and 500 KVA
330DTR Substation Supports as per technical specification, approved drawings and scope of work
331PSC pole 9M- /487 kg
332A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
333A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
334Prefabricated Items likes V cross arm, Pole top bracket, Channel cross arm (3M,2.4M), Clamps, 2 line/4 line cross arm, Cross bracings, Guarding channels, MS flat of given sizes, GI wire, GI strip 25 x 3mm , GI strip 25 x 6mm etc as per specifications and scope of work
335Bolts & Nuts & Washers of Various sizes with stud
33612KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
337Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work.
338PolymerInsulators with hardware fittings, hardware etc
33911 KV Disc Insulator with MS Cleat and harware fittings
34011 KV Pin Insulator with GI pin
341DO Fuse Unit with support insulators
342Earthing arrangement
34340 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
3446Kg 10 inch PVC pipe of length 30 cm withPVC end cap
345Earth/ Groundenhancementmaterial
346Lightning Arrestor
347Distribution class Lightning Arrestor 9 KV, 5 KA
348Station Class Lightning Arrestor 9 KV, 10 KA
349ACSR Conductor Raccoon for providing drops and jumper connections
350ACSR Conductor Rabbit for providing LTconnections
3511.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec
3521x 120 sqmm Al conductor cable
353Aluminium socket
354New Distribution Transformer (Level 1) with all Accessories as per spec
35511KV/433 V 100 KVA Distribution Transformer with all Accessories as per spec
356LT Distribution Box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, earthing bus, earthing terminal front door operate with Fuse units & proper locking arrangement as per tech.spec
3573 Pahse 100 KVA 2/3 way Distribution Box
358Statutory Boards
359RDSS Sign Board as per specifications
360LT Insulators and hardware fittings as per specification and scope of work
361LT shackles Set
362LTpin insulator with GI pin
363Earth Knobfor neutral line and providing earth
364Aluminium parallel groove clamp
365Dead-end Rabbit
366BOQ-12 Enhancement of Transformer
367DTR Substation Supports as per technical specification, approved drawings and scope of work
368PSC pole 9M- /487 kg
369A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
370A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
371Prefabricated Items likes V cross arm, Pole top bracket, Channel cross arm (3M,2.4M), Clamps, 2 line/4 line cross arm, Cross bracings, Guarding channels, MS flat of given sizes, GI wire, GI strip 25 x 3mm , GI strip 25 x 6mm etc as per specifications and scope of work
372Bolts & Nuts & Washers of Various sizes with stud
37312KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
374Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work.
37511 KV Pin Insulator with GI pin
376DO Fuse Unit with support insulators
377Earthing arrangement
37840 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
3796Kg 10 inch PVC pipe of length 30 cm withPVC end cap
380Earth/ Groundenhancementmaterial
381Distribution class Lightning Arrestor 9 KV, 5 KA
382Station Class Lightning Arrestor 9 KV, 10 KA
383ACSR Conductor Raccoon for providing drops and jumper connections
384ACSR Conductor Rabbit for providing LTconnections
3851.1 KV XLPE insulated unarmoured cable for connection of transformer
3861x 120 sqmm Al conductor cable
3871x185 sqmm Al conductor cable
388Aluminium socket
389New Distribution Transformer (Level 1) with all Accessories as per spec
39011KV/433 V 160 KVA Distribution Transformer with all Accessories as per spec
39111KV/433 V250KVA Distribution Transformer with all Accessories as per spec
39211KV/433 V 315 KVA Distribution Transformer with all Accessories as per spec
3933 Phase 160 KVA 3 wayDistribution Box
3943 Phase 250 KVA 3 way Distribution Box
3953 Phase315 KVA 4 way Distribution Box
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail