Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supply & Installation or only Installation offollowing types and ratings of COMPACT FLUORESCENT LAMPS (NON INTEGRAL). |
| 2 | 13 W 2 Pin CFL Lamps……………………….……. SUPPLY |
| 3 | 13 W 2 Pin CFL Lamps……………………..…... ERECTION |
| 4 | 18 W 2 Pin CFL Lamps …………………..…………. SUPPLY |
| 5 | 18 W 2 Pin CFL Lamps ……………………...…… ERECTION |
| 6 | 18 W 4 Pin CFL Lamps …………………...……… ERECTION |
| 7 | 36 W 4 Pin CFL Lamps ……………………..………. SUPPLY |
| 8 | 36 W 4 Pin CFL Lamps………………..………… ERECTION |
| 9 | Installation of following ratings of FLUORESCENT TUBE LIGHTS. |
| 10 | 20 W (2\") FTL UV Lamp for Fly catcher……..… ERECTION |
| 11 | 36 W (4\") FTL …………………….…………….…. ERECTION |
| 12 | Supply and Installation or only installation of following types and ratings of ELLIPTICAL, TUBULAR SHAPED, SINGLE AND DOUBLE ENDED DISCHARGE LAMPS. |
| 13 | 70W ES type Metal Halide/HPSV lamps…….... ERECTION |
| 14 | 125W ES type HPMV lamps…….……………... ERECTION |
| 15 | 150W ES type MH lamps………………………..… SUPPLY |
| 16 | 150W ES type MH lamps…...………………..… ERECTION |
| 17 | 250W ES type HPMV/SV/MH lamps…...…...… ERECTION |
| 18 | 400W ES type HPMV/MH/HPSV lamps…….… ERECTION |
| 19 | Installation of following types and ratings of COPPER WOUND BALLASTS. |
| 20 | Ballasts For 11W CFL Lamps…...……………..ERECTION |
| 21 | Ballasts for 18W CFL Lamps…...……….......…ERECTION |
| 22 | Ballasts for 36W Fluorescent Tube Lights….… ERECTION |
| 23 | Ballasts for 70W MH / SV Lamps…...…......….ERECTION |
| 24 | Ballasts for 125W ES type MV lamps…......….ERECTION |
| 25 | Ballasts for 150W ES type MH/HPMV/SV lamps … ERECTION |
| 26 | Ballasts for 250W HPMV/SV/MH lamps…….… ERECTION |
| 27 | Ballasts for 400W HPMV/MH/HPSV lamps…… ERECTION |
| 28 | Installation of following types and ratings of ELECTRONIC BALLASTS for Fluorescent Tube Light Fixtures. |
| 29 | Ballasts For 1/2 x 36W Fluorescent Tubelight Fixtures …...……………..….…..ERECTION |
| 30 | Installation of following types and ratings ofELECTRONIC IGNITORS. |
| 31 | Ignitors For 70W HPSV Lamps…...…......…….. ERECTION |
| 32 | Ignitors For 150W HPSV Lamps …...…......……. ERECTION |
| 33 | Ignitors For 250W HPSV Lamps …...…......……. ERECTION |
| 34 | Installation of following types and ratings of LED LAMP Driver Units for LED Lamp Fixtures. |
| 35 | Driver Units For 22W…...……………..….…….. ERECTION |
| 36 | Driver Units For 38W…...……………..….…….. ERECTION |
| 37 | Driver Units For 150W…...……………..….…… ERECTION |
| 38 | Installation of following types and ratings of OTHER LIGHTING ACCESSORIES. |
| 39 | 2/4 Pin CFL lamp Holder…...…....................…. ERECTION |
| 40 | Bimetallic Fluorescent Tube Light Starter....…. ERECTION |
| 41 | Rectangular/Barrel/Press fit Soldering/Connection Types of Tube Light Starter Holder/Base...................…. ERECTION |
| 42 | Screw Mounting / Press Fit type Bi-pin Rotor Holder For FTL…...…............................................................…. ERECTION |
| 43 | End cap for mounting all types of FTL Bi pin Rotor Holder …...…............................................................…. ERECTION |
| 44 | ES & BC type Porcelain Lamp Holder for all types and ratings of discharge lamps.….....................................…. ERECTION |
| 45 | Installation of following types and ratings of FLUSH MOUNTING TYPE SWITCHES, SOCKETS AND OTHER CONTROL ACCESSORIES. |
| 46 | 6 Amps 1 way SP Switch.…......................….. ERECTION |
| 47 | 6 Amps 5 pin socket.…...............................…. ERECTION |
| 48 | 6 Amps 3 Pin Plug Top…..........................….. ERECTION |
| 49 | 16 Amps 1 way SP Switch….....................….. ERECTION |
| 50 | 16 Amps 5 pin socket.….............................…. ERECTION |
| 51 | 16 Amps 3 Pin Plug Top…........................….. ERECTION |
| 52 | Switch/Socket Type 5 Step Electronic Ceiling Fan Regulator…...…................................................................ ERECTION |
| 53 | 20 A Industrial Metal Clad Scrapping Type Plug top…...…................................................................ ERECTION |
| 54 | 20 A Industrial Metal Clad Socket…..........….. ERECTION |
| 55 | 2.25 µFd Ceiling Fan Capacitor….............….. ERECTION |
| 56 | Supply & Installation of RIGID PLASTIC, SURFACE MOUNTING TYPE, HEAVY DUTY ABC PLASTIC BOXES suitable for mounting flush type switches and sockets as per the following. |
| 57 | 2 module.…...............................................…….. SUPPLY |
| 58 | 2 module.…................................................…. ERECTION |
| 59 | 3 module.…...............................................…….. SUPPLY |
| 60 | 3 module.…................................................…. ERECTION |
| 61 | 4 module.…...............................................…….. SUPPLY |
| 62 | 4 module .….................................................…. ERECTION |
| 63 | 6 module.…...............................................…….. SUPPLY |
| 64 | 6 module.…................................................…. ERECTION |
| 65 | 8 module.…................................................…….. SUPPLY |
| 66 | 8 module.…................................................…. ERECTION |
| 67 | Supply & Installation or only installation of MODULAR FLUSH TYPE SWITCHES, SOCKETS AND OTHER CONTROL ACCESSORIES as per the following. |
| 68 | 6 Amps 1 way SP Switch.............................….….. SUPPLY |
| 69 | 6 Amps 1 way SP Switch................................... ERECTION |
| 70 | 6 Amps 5 pin socket........................................... ERECTION |
| 71 | 16 Amps 1 way SP Switch...........................….….. SUPPLY |
| 72 | 16 Amps 1 way SP Switch................................. ERECTION |
| 73 | 16 Amps 5 pin socket..................................….….. SUPPLY |
| 74 | 16 Amps 5 pin socket........................................ ERECTION |
| 75 | Switch / Socket Type 5 Step Electronic Ceiling Fan Regulator........................................…………………...…….... SUPPLY |
| 76 | Switch / Socket Type 5 Step Electronic Ceiling Fan Regulator...............................………………………...…...... ERECTION |
| 77 | 1 Way Blank Plates........................................... ERECTION |
| 78 | Supply & Installation of 2 mm THICK ELECTRICAL GRADE HYLAM SHEETS including making cut out for the switches, sockets and other accessories and installation.……………………………………….………………... SUPPLY |
| 79 | Supply & Installation of 2 mm THICK ELECTRICAL GRADE HYLAM SHEETS including making cut out for the switches, sockets and other accessories and installation.…………………………………………..………..... ERECTION |
| 80 | Supply & Installation or only installation of MCBs, MCCBs and MCB Enclosures as per the following. |
| 81 | SP MCB : 2 Amps to 32 Amps……..….……..... ERECTION |
| 82 | DP MCB : 2 Amps to 32 Amps……..…….…..... ERECTION |
| 83 | 4P MCB : 6 Amps to 32 Amps……..…….…..... ERECTION |
| 84 | DP MCB Metal Enclosure with MCB……......... ERECTION |
| 85 | 4P MCB Metal Enclosure with MCB……......... ERECTION |
| 86 | Enclosure with 20 Amps Metal Clad Plug & Socket suitable for DP MCB with 1 x 20 Amps DP MCB for AC points ………………...……………….……………..……... SUPPLY |
| 87 | Enclosure with 20 Amps Metal Clad Plug & Socket suitable for DP MCB with 1 x 20 Amps DP MCB for AC points………………………………………..………….... ERECTION |
| 88 | 63 Amps 4 Pole MCCB with spreaders and extended links………………………………………..………….... ERECTION |
| 89 | 100 Amps 4 Pole MCCB with spreaders and extended links………………………………………..………....... ERECTION |
| 90 | Supply & Installation of POWER EXTENSION BOARDS of size: 250 mm X 200 mm X 50 mm made out of 1.6 mm thick CRCA MS sheet steel covered with 2 mm thick Hylam sheet cover, cover fixed with 1 x 16 Amps Flush type SP MCB, 1 x Flush Type Red Indicator, 1 x 16 Amps Flush Type 1 way SP Switch and 5 pin socket , 3 x 6 Amps Flush Type 1 way SP Switches and 5 pin sockets, wired with 2.5 sq.mm FRLS PVC insulated copper conductor wire, box provided with 2 Nos. M6 x 15 mm brass bolts, nuts & washers for earthing purpose, surface 7 tanks processed, painted with powder coating including installation to RCC/Brick wall/ MS structure using wood screws/GI bolts & nuts, testing and commissioning.……....................…........ SUPPLY |
| 91 | Supply & Installation of POWER EXTENSION BOARDS of size: 250 mm X 200 mm X 50 mm made out of 1.6 mm thick CRCA MS sheet steel covered with 2 mm thick Hylam sheet cover, cover fixed with 1 x 16 Amps Flush type SP MCB, 1 x Flush Type Red Indicator, 1 x 16 Amps Flush Type 1 way SP Switch and 5 pin socket , 3 x 6 Amps Flush Type 1 way SP Switches and 5 pin sockets, wired with 2.5 sq.mm FRLS PVC insulated copper conductor wire, box provided with 2 Nos. M6 x 15 mm brass bolts, nuts & washers for earthing purpose, surface 7 tanks processed, painted with powder coating including installation to RCC/Brick wall/ MS structure using wood screws/GI bolts & nuts, testing and commissioning.…….………............... ERECTION |
| 92 | Supply and installation of following sizes of MS BOXES made out of 1.6 mm thick CRCA MS sheet steel covered with 2 mm thick Hylam sheet cover,box provided with 2 Nos. M6 x 15 mm brass bolts, nuts & washers for earthing purpose, surface 7 tanks processed, painted with powder coating including installation to RCC/Brick wall/MS structure using wood screws/GI bolts & nuts. |
| 93 | 100 x 100 x 50 mm………….………..…....……... SUPPLY |
| 94 | 100 x 100 x 50 mm……………..………........... ERECTION |
| 95 | 150 x 100 x 50 mm………….……………..……... SUPPLY |
| 96 | 150 x 100 x 50 mm……………..………........... ERECTION |
| 97 | 200 x 100 x 50 mm………….……………..……... SUPPLY |
| 98 | 200 x 100 x 50 mm……………..………........... ERECTION |
| 99 | Supply and Installation of FRLS PVC INSULATED MULTI STRAND COPPER CONDUCTOR WIRES in the following sizes. |
| 100 | 1.5 Sq.mm………….………..……………....……... SUPPLY |
| 101 | 1.5 Sq.mm………….………..……………………ERECTION |
| 102 | 2.5 Sq.mm………….………..……………....……... SUPPLY |
| 103 | 2.5 Sq.mm………….………..……………………ERECTION |
| 104 | Supply and Installation or only installation of FRLS PVC INSULATED, PVC OUTER SHEATHED MULTI STRAND COPPER CONDUCTOR WIRES FLEXIBLE CABLE in the following sizes. |
| 105 | 3 C x 1.5 Sq.mm………….………………....……... SUPPLY |
| 106 | 3 C x 1.5 Sq.mm………….………………...…... ERECTION |
| 107 | 3 C x 2.5 Sq.mm………….………………...…... ERECTION |
| 108 | Supply & Installation of ELECTRICAL GRADE ISI MARKED FRLS PVC CONDUITS IN IVORY/WHITE COLOUR with all types of accessories on RCC/Brick wall surface/MS Angle with spacer saddles at regular intervals as per the following. |
| 109 | 19 mm dia conduit of 1.8 mm thick…….....…..…... SUPPLY |
| 110 | 19 mm dia conduit of 1.8 mm thick……....…..... ERECTION |
| 111 | 25 mm dia conduit of 1.8 mm thick……....…...…... SUPPLY |
| 112 | 25 mm dia conduit of 1.8 mm thick……....…..... ERECTION |
| 113 | Maintenance / Repair of following types and ratings of Electrical Light Fixtures mounted at various heights. Note: Supply & Installation of components will be measured under their respective items. |
| 114 | 1/2x36W,1/2x65W Fluorescent tube light luminaires…………………..………………………..…..... MAINTENANCE |
| 115 | 1/2X11W/2X18W CFL luminaires…..……... MAINTENANCE |
| 116 | 2/3x36w CFL luminaires……………….….... MAINTENANCE |
| 117 | 70/125/150W MH/HPMV/HPSV Medium Bay Luminaires…....…………………………..………....…...... MAINTENANCE |
| 118 | 250/400W HPMV/HPSV High Bay Luminaires...MAINTENANCE |
| 119 | 2X150W/250W HPSV Flood light luminaires…MAINTENANCE |
| 120 | 10/13/26W CFL and 12V/50W Recess Mounting type Halogen Down light Lamps non integral.……….….... MAINTENANCE |
| 121 | Rewiring of 1/2 x 36W Flouresent tube light luminaires with 0.5 Sq.mm PVC insulated solid copper conductor wires in case of wires burnt out and conversion from copper wound ballast to Electronic ballast etc including supply of wires...…………………….......…..................................... REWIRING |
| 122 | Replacement & Installation of Ceiling / Wall Mounting Fans / Air Circulators. All Fans will be issued by the dept. free of cost, shifting and installation alone is in the scope of this contract. |
| 123 | 1200/1400mm Sweep Ceiling Fans...…….… REPLACEMENT &ERECTION |
| 124 | 450 mm Wall Mounting fans……................... REPLACEMENT & ERECTION |
| 125 | 450/600 mm Wall Mounting Air Circulators ….. REPLACEMENT & ERECTION |
| 126 | Maintenance and Servicing of Ceiling / Wall Mounting fans / Air Circulators as per the following. |
| 127 | 1200/1400 mm Sweep Ceiling Fans…...........MAINTENANCE |
| 128 | 450 mm Wall Mounting Fans/Pedestal Fans … MAINTENANCE |
| 129 | 450 / 600mm Wall Mounting Air Circulators.....MAINTENANCE |
| 130 | Rewinding of defective 450/600mm Air Circulator Motors including removing, dismantling, rewinding, reassembling and reinstallation as per the following. ...REWINDING & ERECTION |
| 131 | Replacement of following types of Double Ball Bearings for Ceiling, Wall Mounting Fans and Air Circulators. |
| 132 | 6201 …....................................…................ REPLACEMENT |
| 133 | 6202 …............................................…........ REPLACEMENT |
| 134 | 6203 ….....................................……..…...... REPLACEMENT |
| 135 | Maintenance of 3 Phase Flush/Surface wall mounted 4/6/8/12 Way/16 Module MCB TPN/SPN Lighting/Power/Roof Extractor Distribution Boards and MCC Panels as per the following. |
| 136 | 4/6 Way upto 1150 x 950 x 165 mm……........ MAINTENANCE |
| 137 | 8/12 Way upto 1300 x 950 x 165 mm….......... MAINTENANCE |
| 138 | Single row 16 Module upto 460 mm x 250 mm..MAINTENANCE |
| 139 | MCC, Control panels and Feeder pillar boxes of sizes upto 2,000 mm x 2,000 mm x 1,000 mm. …........................ MAINTENANCE |
| 140 | Maintenance of Electrical System and Lightning Protection Earth pits including Cleaning of chamber, terminals, application of petroleum jelly, adding of salt & watering, measurement of earth resistance values, repairing of damaged brick work & plastering & PCC if any, replacement of Brass bolts & nuts & Bimetallic Clamps, C.I. top covers and watering, etc as per the following. Note: Civil works and CI top Cover with frame replacement shall be measured in respective BOQ items. |
| 141 | Electrical system Plate Earth Electrode assembly Brick Work Earth Pit Chambers of Size: 600 mm X 600 mm.…………………………………………….…..... MAINTENANCE |
| 142 | Lightning Protection Copper Earth Rod Electrode assembly Brick Work Earth Pit Chambers of Size: 300 mm X 300 mm........................................................................ MAINTENANCE |
| 143 | Supply and Installation of Medium Duty Cast Iron earth pit chamber inspection cover with frame as per the following. |
| 144 | Size: 300 x 300 mm................................................ SUPPLY |
| 145 | Size: 300 x 300 mm............................................ ERECTION |
| 146 | Size: 450 x 450 mm................................................ SUPPLY |
| 147 | Size: 450 x 450 mm............................................ ERECTION |
| 148 | Size: 600 x 600 mm................................................ SUPPLY |
| 149 | Size: 600 x 600 mm............................................ ERECTION |
| 150 | Extension of metered temporary construction power supply from LT MCC panels using free standing MS meter boards and copper/aluminium power cable at BARC, Mysore at various process facilities. Note: Meter board with cables alone will be provided by the dept. free of cost. Shifting, connecting temporarily, testing and commissioning is in the scope of contractor. ......... TEMPORARY POWER SUPPLY ERECTION |
| 151 | REMOVAL OF EXISTING LIGHT FIXTURES |
| 152 | Removal of existing 1/2X36W FTL and 1/2x11W/2x18W/3x36W CFL fixtures at variuos heights.…......................... REMOVAL |
| 153 | Removal of existing 125/150/250 W Low/ Medium/ High Bay Light Fixtures of various ratings at various heights................................................................................. REMOVAL |
| 154 | Installation of Street Light Fixture Accessories as per the following. |
| 155 | Vacuum Impregnated Copper Wound Ballasts…. ERECTION |
| 156 | Electronic Ignitors................................................. ERECTION |
| 157 | Lamp holders........................................................ ERECTION |
| 158 | Maintenance and Installation of Street Light Junction Boxes and Control Panels as per the following. |
| 159 | Maintenance of Street Light Junction Boxes of size upto 260 x 200 x 125 mm with connectors.……….......... MAINTENANCE |
| 160 | Installation of new street light JB boxes of size upto 260 x 200 x 125 mm with connectors in place of existing or new location including removal of old junction boxes................ ERECTION |
| 161 | Maintenance of Street Light Control Panels of size upto 600 x 400 x 250 mm consisting of Electrical Power, Control and Indication accessories.……………….…….... MAINTENANCE |
| 162 | Supply & Installation of LED Light Fixtures including removal of existing LED Light fixtures for Street light poles upto a height of 2.5m/3.75m/6.0m/7.0m /10.0m. |
| 163 | 20W LED street light fixtures.................................. SUPPLY |
| 164 | 20W LED street light fixtures.............................. ERECTION |
| 165 | 45W LED street light fixtures.................................. SUPPLY |
| 166 | 45W LED street light fixtures.............................. ERECTION |
| 167 | 60W LED street light fixtures.................................. SUPPLY |
| 168 | 60W LED street light fixtures.............................. ERECTION |
| 169 | 90W LED street light fixtures.................................. SUPPLY |
| 170 | 90W LED street light fixtures.............................. ERECTION |
| 171 | Supply, Installation, Testing and Commissioning of following types and ratings of LED light fixtures including removal of the existing CFL/FTL fixtures and replacing with a new one or installing a new one at a fresh location.Industrial Batten Type 120 Cm. LED Light Fixtures |
| 172 | 2000 Lumens ........................................................... SUPPLY |
| 173 | 2000 Lumens ....................................................... ERECTION |
| 174 | 4000 Lumens ........................................................... SUPPLY |
| 175 | 4000 Lumens ....................................................... ERECTION |
| 176 | LED Surface Mounting Square Type Down Light Fixtures with driver Units |
| 177 | 1200 Lumens......................................................... SUPPLY |
| 178 | 1200 Lumens..................................................... ERECTION |
| 179 | Suspended type Industrial High Bay LED Light Fixtures |
| 180 | 14500 Lumens....................................................... SUPPLY |
| 181 | 14500 Lumens................................................... ERECTION |
| 182 | 19500 Lumens....................................................... SUPPLY |
| 183 | 19500 Lumens................................................... ERECTION |
| 184 | Industrial LED Flood Light Fixtures |
| 185 | 11000 Lumens....................................................... SUPPLY |
| 186 | 11000 Lumens................................................... ERECTION |
| 187 | 14500 Lumens....................................................... SUPPLY |
| 188 | 14500 Lumens................................................... ERECTION |
| 189 | Industrial LED High bay Retrofit Lamps with E27/E40 Cap. |
| 190 | 10000 Lumens....................................................... SUPPLY |
| 191 | 10000 Lumens................................................... ERECTION |
| 192 | 20000 Lumens....................................................... SUPPLY |
| 193 | 20000 Lumens................................................... ERECTION |
| 194 | Retrofitting of existing FTL, CFL and Discharge lamps/bulbs with 65000 K LED Lamps as per the following. |
| 195 | 36W CFL-NI PL-L LED Lamp for 2/4 PIN 36 W CFL lamps................................................................................ SUPPLY |
| 196 | 36W CFL-NI PL-L LED Lamp for 2/4 PIN 36 W CFL lamps............................................................................ ERECTION |
| 197 | 20W/2100 Lumens TLED Lamp for 1200 mm long 36 W FTL Fixtures .................................................................. SUPPLY |
| 198 | 20W/2100 Lumens TLED Lamp for 1200 mm long 36 W FTL Fixtures .............................................................. ERECTION |
| 199 | LED Lamp for 2/4 PIN 11/13/18 W CFL lamps ........... SUPPLY |
| 200 | LED Lamp for 2/4 PIN 11/13/18 W CFL lamps ....... ERECTION |
| 201 | LED Lamp for 70W/125W HPMV lamps ..................... SUPPLY |
| 202 | LED Lamp for 70W/125W HPMV lamps ................. ERECTION |
| 203 | Supply, Installation, Testing and Commissioning of following Decorative type LED light fixtures. |
| 204 | Indoor Square Decorative Type LED luminaire Surface Mounting type of 3200 Lumens rating. ................... SUPPLY |
| 205 | Indoor Square Decorative Type LED luminaire Surface Mounting type of 3200 Lumens rating. ............... ERECTION |
| 206 | LED Bulk Head type Light Fixture 10 Watts / 1100 Lumens rated................................................................. SUPPLY |
| 207 | LED Bulk Head type Light Fixture 10 Watts / 1100 Lumens rated............................................................. ERECTION |
| 208 | Supply, Installation, Testing and Commissioning of Motion Control Sensors mounted in a ABC Plastic box of approx. size 125 x 125 x 50 mm, with top removable cover with screws, mounted with the motion control sensor, with knockouts for conduiting all round including installation to wall with wood screws, testing and commissioning. ......................... SUPPLY |
| 209 | Supply, Installation, Testing and Commissioning of Motion Control Sensors mounted in a ABC Plastic box of approx. size 125 x 125 x 50 mm, with top removable cover with screws, mounted with the motion control sensor, with knockouts for conduiting all round including installation to wall with wood screws, testing and commissioning. ..................... ERECTION |
| 210 | ATTENDING ELECTRICAL COMPLAINTS / FUSE OF CALLS |
| 211 | Attending Lighting/Power/Electrical complaints including identification of fault by refering concerned electrical drgs. If available with dept. or by tracing the circuit physically if needed, Switching ON a trippedO/g or I/c MCB, switching on a switch put off, attending a failed wire joint, loose contact in the electrical circuit if anywhere from the DB upto the load point. S & I of components if any will be measured under the respective items.................................................... ATTENDING COMPLAINTS |
| 212 | Attending Electrical complaints on Industrial Vertical/Horizontal Storage/Instant Geysers of all ratings/capacities including identification of fault by checking, replacing a failed Thermostat, Thermal cutout, Heating element, gasket, attending a failed wiring inside and loose contact etc. Necessary spare Thermostat, Thermal cutout, Heating element and gasket, if any, will be provided by the dept. ........................... ATTENDING COMPLAINTS |
| 213 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DBS AND PANELS. |
| 214 | STREET LIGHT CONTROL PANEL: Outdoor MS Self standing Street Light Control panel made up of 1.6 mm thick MS sheet steel enclosure double door type of size: 1200mm (H) x600mm (W) x 400 mm (D) mounted over a MS angle stand frame work, IP 65 protected, hood on top, consisting of 1 No. 63A 4P MCB as an incomer,3 Nos. 32 Amps 4 Pole contactor, 1 No. multi time setting digital timer, one set of RYB LED indicationlamps, 1 No. Auto/manual selector switch mounted on inner door with with suitable fuse TBs for protection, 1 No. 2 A DP MCB for control circuit protection, with terminal blocks on bottom with incomoing TBs suitable for 25 sq.mm cables and outgoing TBs suitable for 10 sq.mm cables, with complete power wiringwith 6 sq.mm, control wiring with 2.5 sq.mm FRLS PVC insulatedmulti strand copper conductor wires, to work on 415V 50 Hz. AC power supply, powder coated, bottom angle frame wok with holes for installation, front opening,doors with quarter turn locks and pad lock,gasket all around, all components except indicating lamps and A/M selector switch mounted on mounting plate, with suitable wire ways for wires management, wires identification, termination with copper terminal ends, name and danger plate etc. as per the drg. enclosed herewith....................... SUPPLY |
| 215 | STREET LIGHT CONTROL PANEL: Outdoor MS Self standing Street Light Control panel made up of 1.6 mm thick MS sheet steel enclosure double door type of size: 1200mm (H) x600mm (W) x 400 mm (D) mounted over a MS angle stand frame work, IP 65 protected, hood on top, consisting of 1 No. 63A 4P MCB as an incomer,3 Nos. 32 Amps 4 Pole contactor, 1 No. multi time setting digital timer, one set of RYB LED indicationlamps, 1 No. Auto/manual selector switch mounted on inner door with with suitable fuse TBs for protection, 1 No. 2 A DP MCB for control circuit protection, with terminal blocks on bottom with incomoing TBs suitable for 25 sq.mm cables and outgoing TBs suitable for 10 sq.mm cables, with complete power wiringwith 6 sq.mm, control wiring with 2.5 sq.mm FRLS PVC insulatedmulti strand copper conductor wires, to work on 415V 50 Hz. AC power supply, powder coated, bottom angle frame wok with holes for installation, front opening,doors with quarter turn locks and pad lock,gasket all around, all components except indicating lamps and A/M selector switch mounted on mounting plate, with suitable wire ways for wires management, wires identification, termination with copper terminal ends, name and danger plate etc. as per the drg. enclosed herewith.................. ERECTION |
| 216 | AUTO WORK SHOP PANEL: Outdoor MS Self standing Power Control panel made up of 1.6 mm thick CRCA MS sheet steel enclosure, double door type, of size: 1500 mm (H) x1200 mm (W) x 600 mm (D) mounted over an MS angle stand frame work, Vermin Proof, IP 54 protected, Indoor duty,consisting of 1 No. 160 A 4P MCCB as an incomer,5 Nos. 32 Amps 4 Pole MCBs, 3 Nos. 63 Amps 4 Pole MCBs, 3 Nos. 100 Amps 4 Pole MCCBs, one set of RYB LED indicationlamps, with incoming cable directly terminated to the I/C MCCB with spreader links & phase barriers, with all out going cables terminated on the cable alleywith bolted type melamine terminal blocks, with aluminium bus bar chamber on the rear side,complete wiring with FRLS PVC insulatedmulti strand copper conductor wires of appropriate size, to work on 415V 50 Hz. AC power supply, powder coated, bottom angle frame wok with holes for installation, front & back opening,doors with quarter turn locks and pad lock,gasket all around, all components except indicating lamps mounted on mounting plate, with suitable wire ways for wires management, wires identification, termination with copper terminal ends, name and danger plate etc. as per the drg. enclosed herewith..................................................................................... SUPPLY |
| 217 | AUTO WORK SHOP PANEL: Outdoor MS Self standing Power Control panel made up of 1.6 mm thick CRCA MS sheet steel enclosure, double door type, of size: 1500 mm (H) x1200 mm (W) x 600 mm (D) mounted over an MS angle stand frame work, Vermin Proof, IP 54 protected, Indoor duty,consisting of 1 No. 160 A 4P MCCB as an incomer,5 Nos. 32 Amps 4 Pole MCBs, 3 Nos. 63 Amps 4 Pole MCBs, 3 Nos. 100 Amps 4 Pole MCCBs, one set of RYB LED indicationlamps, with incoming cable directly terminated to the I/C MCCB with spreader links & phase barriers, with all out going cables terminated on the cable alleywith bolted type melamine terminal blocks, with aluminium bus bar chamber on the rear side,complete wiring with FRLS PVC insulatedmulti strand copper conductor wires of appropriate size, to work on 415V 50 Hz. AC power supply, powder coated, bottom angle frame wok with holes for installation, front & back opening,doors with quarter turn locks and pad lock,gasket all around, all components except indicating lamps mounted on mounting plate, with suitable wire ways for wires management, wires identification, termination with copper terminal ends, name and danger plate etc. as per the drg. enclosed herewith................................................................................. ERECTION |
| 218 | CABLING: Installation, Testing and Commissioning of Aluminium/Copper Conductor, Armoured Power cables as per the following. Note: Cables in standard lengths alone will be issued by the dept. free of cost at BARC central Stores in wooden/steel cable drums, shifting to the location of laying and installation is in the scope of contractor. In ground complete with excavation in all types of soil, supply & installation of table moulded bricks at sides and on top, covering the cable on all sides with M sand, dressing the cable, refilling the excavated trench with soil and ramming. The depth of trench will be 800 mm from the FGL. |
| 219 | 2C/3C/4C X 2.5/4 Sq. mm Copper …………….... ERECTION |
| 220 | 4C X10/16/25 Sq. mm Aluminium ……………..… ERECTION |
| 221 | In RCC cable trench, M.S.Cable Supports, G.I. Cable Trays, RCC hume/DWC Pipes, GI/MS pipes and RCC/Brick wall surfaces including supply and installation of cable clamping accessories like GI Spacer saddles, screws and Cable Ties etc. |
| 222 | 2C/3C/4C X 2.5/4 Sq. mm Copper ……………... ERECTION |
| 223 | 4C X 16/25/3.5C x 70 Sq. mm Aluminium …….... ERECTION |
| 224 | CABLES END JOINTINGEnd jointing of the following Copper/Aluminium conductor, Multi Core, Armoured Power cables by crimping method including supply of materials viz. single compression heavy duty brass cable glands, wires dressing and Copper/Aluminium terminal endsetc. as per the following. |
| 225 | 4C X 2.5 Sq. mm / 4C X 4 Sq. mm Copper ……...…... SUPPLY |
| 226 | 4C X 2.5 Sq. mm / 4C X 4 Sq. mm Copper ….. END JOINTING |
| 227 | 4C X 10/16/25 Sq. mm Aluminium ……………..……... SUPPLY |
| 228 | 4C X 10/16/25 Sq. mm Aluminium …………..... END JOINTING |
| 229 | 3.5 C X 70 Sq. mm Aluminium …………….……...…... SUPPLY |
| 230 | 3.5 C X 70 Sq. mm Aluminium …………..…..... END JOINTING |
| 231 | STRAIGHT THROUGH JOINTING OF POWER CABLES Installation, Testing and Commissioning of Heat Shrinkable type LT Cable Straight Through jointing kit suitable forAluminium/Copper conductor, armoured, XLPE insulated power cable including crimping etc. as per the following. |
| 232 | Upto and including 4C X 10 Sq. mm Aluminium………………………….… STRAIGHT THROUGH JOINTING |
| 233 | 4C X 16 / 25 / 3.5 C x 70 Sq. mm Aluminium………………………….… STRAIGHT THROUGH JOINTING |
| 234 | REMOVAL OF EXISTING REDUNDANT POWER AND CONTROL CABLES laid in RCC cable trenches/on over head cable trays/on the wall, pipes, segregating as per size, coiling the removed cables, identifying and shifting to the designated storage place as per the instructions of EIC. |
| 235 | Upto and including 3.5C x 70 sq mm alu. Conductor power cable………………………………....…. REMOVAL |
| 236 | Installation of following sizes of flexible telephone wires in the existing Metal / PVC Conduit / Casing & cappings. Note: Flexible Telephone Wires alone will be issued by the dept. free of cost and installation is in the scope of contract. |
| 237 | 2 Pair ……………………………………………… ERECTION |
| 238 | 5 / 10 Pair ………………………………………… ERECTION |
| 239 | EARTHING Installation of Electrolytic grade Copper wire/Flat in excavated trench and in concrete surfaces/pipes etc. as per the following.Note: If excavation is carried out exclusively for the installation of copper wire then only the excavation will be measured under the respective BOQ item. |
| 240 | No.14 SWG Copper Wire ……………….……… ERECTION |
| 241 | No. 8 SWG Copper Wire ………………..……… ERECTION |
| 242 | 25 x 3 / 6 mm Copper flat ……….……....……... ERECTION |
| 243 | Segregation and shifting of Scrap Marerials accumulated due to Lighting Maintenance to BARC Central Stores after obtaining clearance from the dept. as per the following. |
| 244 | Copperitems viz., bare wires, PVC insulated copper wires, flats, links, bus bars, tube light ballasts, ceiling fan motor wdgs etc.………………...….…… SEGREGATION AND SHIFTING |
| 245 | Aluminium items viz., flats, bus bars, ceiling fan bodies,switch box covers, light fixture covers and clamps etc.………………...…………… SEGREGATION AND SHIFTING |
| 246 | E-waste items viz., lgnitors, electronic tubelight ballasts and PCBs etc. ……..………..… SEGREGATION AND SHIFTING |
| 247 | PVC items viz., Light fixture louvers, regulator covers, Canopies, Holders, Fan bodies and Porcelain items etc.……………………...…....… SEGREGATION AND SHIFTING |
| 248 | M.S scrap items viz., angles, flats, enclosures, boxes, panels and light fixtures, reflectors/ railings, junction boxes, pull boxes and plates /sheets etc. .…. SEGREGATION AND SHIFTING |
| 249 | Supply including Transport, Fabrication, Welding, Installation and Painting of MS structural items like ISMA Angles, Channels and Flats etc. ……………………….……...…………. SUPPLY |
| 250 | Supply including Transport, Fabrication, Welding, Installation and Painting of MS structural items like ISMA Angles, Channels and Flats etc. …………………..…... ERECTION & PAINTING |
| 251 | MISCELLANEOUS ITEMS |
| 252 | Supply and installation of \"Cast Iron Cable Route Markers\" with embossed text \"LT Cable\", \"LT Cable Joint\" supported with 500 mm long 40 x 40 x 3 mm M.S angle grouted in concrete block of size 150 x 150 x 150 mm at bottom, painted and installed along the cable route including excavation. ........................................... SUPPLY |
| 253 | Supply and installation of \"Cast Iron Cable Route Markers\" with embossed text \"LT Cable\", \"LT Cable Joint\" supported with 500 mm long 40 x 40 x 3 mm M.S angle grouted in concrete block of size 150 x 150 x 150 mm at bottom, painted and installed along the cable route including excavation. ............................................ ERECTION |
| 254 | Installation of 160 mm nominal dia. \"Double Wall Corrugated (DWC) HDPE pipe\" across roads for cabling. Note: Cable Trench excavation across road will be measured in respective BOQ item. …..………. ERECTION |
| 255 | Supply and installation of 2 mm thick Aluminium engraved labels with white letters in black background including drilling of 2/4 nos. fixing holes and fixing with 2 Nos. suitable fasteners.……………….....……..….. SUPPLY |
| 256 | Supply and installation of 2 mm thick Aluminium engraved labels with white letters in black background including drilling of 2/4 nos. fixing holes and fixing with 2 Nos. suitable fasteners.…………………….…….. ERECTION |
| 257 | Removal and shifting of Existing 7.2 Mtr Curved/StraightArm MS Street Light Tubular Poles including removal of light fixture, excavation around the pole, pulling of existing terminated cables out, along with 1,200 x 350 x 350 mm size PCC concrete pedestal, shifting to the new location and reinstallation including earth work excavation for installation of pole in the new location. ........... REMOVAL, SHIFTING & ERECTION |
| 258 | Removal and Shifting of Existing Street Light Control Panel of size: 750 mm (H) x 450 mm (W) x 350 mm (D) including removal of already terminated cables, earthing, shifting to the new location, reinstallation over a brick work pedestal and commissioning. Note: Civil works viz., PCC shall be measured under respective BOQ items. ................. REMOVAL, SHIFTING & ERECTION |
| 259 | PAINTING WORKS |
| 260 | Painting of MS Tubular Street Light Poles of6.0 Mtr height as per the drg. enclosed. ……..…..……. PAINTING |
| 261 | Painting of MS Feeder Pillar boxes ……… PAINTING |
| 262 | CIVIL WORKS |
| 263 | Excavation in all types of soil including Hard Murram except hard rocks including refilling and levelling. …...… EXCAVATION |
| 264 | Table moulded brick work including plastering. ... PLASTERING |
| 265 | PCC with 1:2:4 ratio concreting .……………….... CONCRETING |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy