National Power Training Institute-NPTI has published Tender For E-Tender For Supply, Installation And Setting-Up Of Advanced Metering Infrastructure (Ami) Laboratory At Npti (Psti), Bangalore -70. Submission Date for this Tender is 23-02-2023. Energy Meter Tenders in bengaluru Karnataka. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Server/ workstationHardware |
2 | Workstation Console, work station processor should be Intel Core i9-12900K12th Generation and go for Intel® Itanium® Processor 9350, 64GB DDR4 RAM, 512 GB SSD, Dedicated Graphics Card with Minimum 4GB Graphic memory, Dual Gigabit LAN ports, At least one port each of USB 3.0 Type-C, USB 3.0 Type-A, USB 2.0 Type A, Optical Mouse, Keyboard, LED Monitor with 22-inch display of 1920x1080p resolution. Windows 10 Pro upgradable to Windows 11 with MS office Professional Plus Perpetual License ** Classification- 04 No"s Work Station Console with 4GB Graphic Card and01 No Work Station with 8 GB Graphic Card. |
3 | Laptop with LAN Port Laptop workstation grade computer with 11th Generation Intel Core i9 processor, 64GB DDR4 RAM, 512 GB SSD, Dedicated Graphic Card with Minimum 4GB Graphic Memory, Dual Gigabit LAN ports, At least one port each of USB 3.0 Type-C, USB 3.0 Type-A, USB 2.0 Type A, Optical Mouse, Keyboard, LED Monitor with 22-inch display of 1920x1080p resolution. Windows 10 Pro upgradable to Windows 11 With MS Office Professional Plus Perpeyual License * Classification- 08 GB Graphic Card |
4 | Server for Utility"s Application Software such as Billing System Software/ SCADA/ R-APDRP/GIS/ERP/Web Portal etc. Processor Cores: 6 Processor Cache: 11.00 MB L3 Processor Name: Intel® Xeon® Scalable 3204 (6 core, 1.9 GHz, 85W) Processor Number: 1 Processor Speed: 1.9 GHz Memory Type: DDR4 Standard Memory: 8 GB (1x 8 GB) RDIMM Hard Drive: 1 TB Power Supply: 350W or better or as per OEM Expansion Slots: 5 PCIe 3.0 Network Controller: 1Gb 2-port Storage Controller: RAID1 Form Factor: Tower |
5 | Head End System Software The HES software shall be capable of performing the primary tasks between smart meter/ DCU and HES such as Automatic polling / On Demand reads, Two way communication establishment, Remote Disconnect / Reconnect, Data encryption for communication, RTC time synchronization, Data retention, Control signals / Event messages handling & logging, Smart meter configuration support, Communication device status and history logging, Network information logging, and Critical and non-critical reporting etc. |
6 | MDM Software The MDM software shall be capable of performing the primary tasks between HES and MDMas well as MDM and Other Applications of DISCOMs such as Meter asset management, Meter installation support, Meter data management, Data Validation, Estimation, and Editing (VEE), Billing determinants calculations, Exception management, Service order management, Customer service support, Data analysis & reporting, Revenue protection support, Demand control / Demand Response Support, Prepayment functionality, Net metering integration, Other business system integrations etc. |
7 | Interface Evaluation Software between Utility"s Software Applications and MDMS As the MDMS is developed the AMI Solution provider, interface software is required for the seamless data exchange between the utility’s existing IT and software infrastructure. The interface evaluation software should be capable of designing the interface between MDM software and the existing Utility’s software applications such as Billing System Software/ SCADA/ R-APDRP/GIS/ERP/Web Portal etc. As this AMI lab is aimed to train the Power Utilities all over India, the offered Interface evaluation software should be capable of designing interfaces for applications of all Power Utilities in India. |
8 | Prepaid Recharge System Simulator This simulator shall be used for recharging the smart prepaid meters.** It should be Pre-paid facility perform by Generalised System. |
9 | In-Home Display The In-Home Display shall be connected to the smart meter wirelessly and the show the essential information of the meter display and alerts to the consumers. The IHD shall be provided with RF and RS-232 communication ports. |
10 | Data Concentrator Unit The data concentrator unit (DCU) shall collect the information from Smart meters and update to the HES. Also, DCU shall receive commands or updates from HES and send to the smart metes. DCU shall work with RF/ 4G/5G Communication. The No. ofmeters need to be connected to each DCU is 20 ( 10 Nos single phase and 10 Nos 3 phase) Expansion upto 100 meters shall be considered. ii) The No. ofData points, event records shall be stored as per relevant standards of REC documents. iii) Data retention period for cyclic recording etc. (As per REC standard documents) |
11 | Router A router with 1xWAN port, 1xLTE LAN, 4xLAN, 1xRS232 port, and 1xUSB port shall be provided. The WAN port shall be connected to lease line provided by NPTI. The router shall work in redundant communication mode with auto failover to LTE network in case leased line is down. When lease line resumes, the router shall change the communication to lease line from LTE network seamlessly. The RS-232 port shall be capable of sending SMS alerts without interrupting the Data connection. |
12 | GPS Clock for laboratory A satellite GPS clock system shall be provided for synchronizing the Real-time for entire AMI network. |
13 | 3-ph Power source (variable test panel) 3-Ph 415V, 15A Panel with Resistive Dummy Load Input Voltage: 3x240V, +20% 3 phase 4 wire, Input frequency: 50Hz +/- 5%, Input Switch: 3 pole MCB of adequate rating, Output Voltage: 3x300V (Adjustable from Zero Volts), Output Current: Adjustable from zero to 15AMPS, Output Burden on: 15VA on each phase Current Circuit, Power Factor select through UPF, LAG LEAD, Isolation between input and output voltages, Isolation between output voltage and output current, Equipment will be rated for continuous operation. |
14 | DC - Electromagnet Magnetic field 67 MT& 02.T DC+5%Ampere turns 1000AT& 17500AT,Electro Magnetic size as per CBIP TR 88, CLAUSE.5.6.2.1 Including Dc Voltage Source. |
15 | AC - Electromagnet AC Electro magnet 00.5mill Tesla & 10 mill Tesla AC +/-5%, 2800 AT for 10millTesla AC Electromagnet. & 140 AT for 0.5 mill Tesla AC Electromagnet. The Electromagnet wound with supper enameled conductor. As per IS 13779. |
16 | Closed Type Dimmer stat Closed type dimmer start Input:0-240V , AC, 50HZ; Output: 0-270V,AC 50 HZ 10 AMPS; Input supply: 3core mains cable; Output: Terminal: BTI Terminals. |
17 | Gauss Meter Rangers full-scale: 0 to 2 and 0 to 20 Kilo Gauss; Accuracy : ±1%full scale + one digit on the 2K.Gass range;: ±2%full scale + one digit on the 20K.Gass range; Resolution : 0.1%of full scale. Visual Display : 3½ Digit panel meter, Power : 240 V a.c. 50 Hz., 10 Watts; Size & Weight:210 mm x 95 mm x 225 mm and 1 Kg appr. |
18 | LED TV70"" with ancillary support connection and support hangers |
19 | Storage & Backup Devices |
20 | External RAID Mass storage device ( for 24 months online backup) |
21 | Exteranl DAT drive : External DAT drive capacity shall be 7TB raw. |
22 | Switches |
23 | Layer II switch (AMI/SCADA/DMS LAN): It shall be with 24 ports + 24 ports of speed 1Gbps (Managed) |
24 | Layer II switch ( Planning & Development system LAN): It shall be with 24 ports + 24 ports of speed 1Gbps (Managed) |
25 | Routers |
26 | Router for interfacingEXTERNAL SYSTEM |
27 | Security system (DMZ) |
28 | Web server with load balancing |
29 | Mail server |
30 | Router |
31 | Firewall & network IDS/IPS |
32 | UTM (Unified Threat Management ) System alongwith Next Generation Industrial Firewall where the DPI tool should be incorporated. - 01 number |
33 | Layer II switch& Multilyers security Switch |
34 | Other Active Devices |
35 | GPS Timesynchronisation system (A satellite GPS clock system shall be provided for synchronizing the Real-time for entire AMI network. ) |
36 | Time, day & date digital displays |
37 | RF Packet Sniffer Hardware |
38 | RF Protocol Analyzer Tool |
39 | DLMS/COSEM Protocol Validation Tool and protocol analyzer |
40 | Printers |
41 | Color inkjet printer with Ethernet networking, Automatic document feeder; Print from phone or tablet; Two-sided printing; Two-sided scanning; Scan to email; Scan to PDF; Fax; Front USB flash drive port; Optional high-capacity trays; Touchscreen; JetIntelligence cartridge- Print, copy, scan, fax(Canon/HP/Epson or Equivalent) |
42 | B/W Laser printer-Ethernet networking, Automatic document feeder; Print from phone or tablet; Two-sided printing; Two-sided scanning; Scan to email; Scan to PDF; Fax; Front USB flash drive port; Optional high-capacity trays; Touchscreen; JetIntelligence cartridge- Print, copy, scan, fax(Canon/HP/Epson or Equivalent) |
43 | GIS SERVER WITHSW : GIS shall be supplied for 100 meters and 50 Nos of other assets (assets are referred to the items of BoQ). |
44 | Ancillary Items |
45 | DC Regulated Power Supply Input : 230V +10%, 50-60Hz, Single Phase, Mode at the Output: Constant Voltage Mode, Output Voltage: 0-30V DC, Output Current: 0-5A DC settable continuously with two potentio- meters provided on Front Panel clearly marked with coarse and fine controls. |
46 | Humidity and Temperature Sensor Display Temperature Range : -50°C ~70°C (-58°F ~ 158°F), Temperature Accuracy : ±1.0°C or ±1.8°F, Humidity Range : 10% ~ 99% RH, Humidity Accuracy : ±5% (35% ~ 75%) & else ±10%, Time / Temperature / Humidity indicate, Temperature Reading for °F &°C, MAX./MIN. Temperature & Humidity Memory, Calendar with Alarm Clock. |
47 | Digital Multi-meter (Calibrated) DC Voltage : 600mV/ 6 / 60 / 600 / 1000V, Accuracy : ± (1.0% rdg + 4 dgt) DC Current600 / 6000 A / 60 / 600mA/ 6 / 20A Accuracy : ± (1.0% rdg + 2 dgt) AC Voltage : 600mV / 6 / 60 / 600 / 750V, Accuracy : ± (1.0% rdg + 5 dgt) AC Current : 600 / 6000 A / 60 / 600mA/ 6 / 20A, Accuracy : ± (1.5% rdg + 5 dgt) |
48 | Magnifying lamp Supply voltage: 230V AC, Lens diameter: Phase 125mm, Lens option: Common and optical lens optional, Magnifications: X3, X5; Adjustable range: 1000mm; Features: Table-clamping, folding arm |
49 | Communication Network Implementation for Smart Meters RF/4G/5G or any other suitable communication system |
50 | Smart Meter-1 Phase as per TS alongwith Test Bench with complete wiring and integration |
51 | Smart Meter-3 Phase as per TS alongwith Test Bench with complete wiring and integration |
52 | Hi-POT Test for Smart Meter functinality with Testing Tool of Meter |
53 | Hi-POT Test for Smart Meter functinality with Testing Tool of Meter |
54 | 3 Phase Inductive Load |
55 | Redundant UPS system: 15 kVA |
56 | 5 KW Solar Power Plant with LED Load ( On and Off Grid) with Bus Enterprise Solution for data display- (approximate 24 LED Lights Load will be supplied by NPTI) |
57 | Distribution Transformer Monitoring System |
58 | Furniture and Support Strcutre: As per the supplier requirement. |
59 | Model of a prepaid Electric Vehicle Charging station at Dashboard. (shall be integrated with the system when it"s available) |
60 | Any otheritems required to meet functional /Performancerequirement as per AMI Lab |
61 | Annual Maintenance Cost ( 5 Years) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail