Tender For Provision Of Hangar And Annexe Building At, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Provision Of Hangar And Annexe Building At. Submission Date for this Tender is 01-07-2023. Aircraft Hanger Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36243748
Corrigendum : Tender For Provision Of Hangar And Annexe Building At
Open Tender
Indian
Andhra Pradesh
visakhapatnam
01-07-2023

Tender Details

Provision Of Hangar And Annexe Building At Provision Of Hangar And Annexe Building At Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Feb-2023 Drawings Other 18-03-2023
2 15-Feb-2023 Corrigendum No 1 Financial Bid 18-03-2023
3 11-Mar-2023 Date Corrigendum 1 Date 25-03-2023
4 17-Mar-2023 Date corrigendum no 2 Date 11-04-2023
5 03-Apr-2023 Date Corrigendum 3 Date 26-04-2023
6 18-Apr-2023 Date corrigendun no 4 Date 15-05-2023
7 08-May-2023 Date Corrigendum 5 Date 31-05-2023
8 24-May-2023 DATECORRIGENDUM6 Date 13-06-2023
9 05-Jun-2023 DATE CORRIGENDUM 7 Date 01-07-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 22.99 Crore /-

BOQ Items

Name of Work: PROVISION OF HANGAR AND ANNEXE BUILDING AT VISAKHAPATNAM
Sl. No. Item Description
1SCHEDULE "A" PART-I to SCHEDULE "A" PART-XIII: Note: Schedule "A" Part-I to Part-XIV are prepriced by MES.Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
2Lump Sum price worked out by the contractor for "Buildings & Structures" as listed in Schedule "A" Part-I.
3Lump Sum price worked out by the contractor for "Site Clearance/Area Development/Earth Work/Excavationas listed in Schedule "A" Part-II.
4Lump Sum price worked out by the contractor for "Pile Foundation"as listed in Schedule "A" Part-III.
5Lump Sum price worked out by the contractor for "Internal Water Supply"as listed in Schedule "A" Part-IV.
6Lump Sum price worked out by the contractor for "Internal Electrification"as listed in Schedule "A" Part-V.
7Lump Sum price worked out by the contractor for "External Water Supply"as listed in Schedule "A" Part-VI.
8Lumpsum price worked out by the contractor for "External Electrification" as listed in Schedule "A" Part-VII.
9Lump Sum price worked out by the contractor for "Area Drainage"as listed in Schedule "A" Part-VIII.
10Lump Sum price worked out by the contractor for "Sewage Disposal"as listed in Schedule "A" Part-IX.
11Lump Sum price worked out by the contractor for "Lightening Protection"as listed in Schedule "A" Part-X.
12Lump Sum price worked out by the contractor for "Road/Path/Culvert", as listed in Schedule "A" Part-XI.
13Lump Sum price worked out by the contractor for "Fire Fighting System"as listed in Schedule "A" Part-XII.
14Lump Sum price worked out by the contractor for "Fire Alarm"as listed in Schedule "A" Part-XIII.
15SCHEDULE "A" PART-XIV (MISCELLANEOUS ITEMS): PILE FOUNDATION , ROAD /CULVERT, AREA DRAINAGE, SEWAGE DISPOSAL, INTERNAL WATER SUPPLY, INTERNAL ELECTRIFICATION , LIGHTENING PROTECTION COOLING APPLIANCES, TV & TELEVISION,CHEMICAL EARTHING , AIR CIRCULATORS, AVIATION LIGHT, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIFICATION, FIRE FIGHTING SYSTEM, FIRE ALARM, DG SET,EOT CRANE,
16PILE FOUNDATION
17Boring for bored cast-in-situ piles 500mmdia. in SDR/any type of rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed.
18Boring for bored cast-in-situ piles 500mmdia. in any strata except SDR/hard rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed.
19Carrying out initial load [Compression] test on 500mm dia. pile complete all as specified and as directed.
20Carrying out initial load [Lateral] test on 500mm dia. pile complete all as specified and as directed.
21Carrying out Routine load [Compression] test on 500mm dia. pile complete all as specified and as directed.
22Carrying out Routine load [Lateral] test on 500mm dia. pile complete all as specified and as directed.
23Carrying out low strain integrity test on cast in situ piles 500mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed.
24INTERNAL WATER SUPPLY:
25Supply and fixing ofBib taps two way, fancy typescrewed down for size of15 mm inner dia, suitable for 16 mm outer dia CPVC pipes complete all as specified and as directed.
26Supply and fixing of health faucet chromium plated , fancy type with steel flexible complete of size of15 mm dia suitable for 16 mm dia outer dia CPVC pipes complete all as specified and as directed.
27S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed 15 mm inner dia suitable for 16 mm dia outer dia CPVC pipescomplete all as specified and as directed.
28S & F Urinal water dropper, chromium plated , fancy type ,suitable for 15mm angle valve/16 mm dia outer dia CPVC pipescomplete all as specified and as directed.
29INTERNAL ELECTRIFICATION
30Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dollyOne lightpoint controlled by one switch complete all as specified and directed.
31Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One fan (ceiling fan/exhaust fan/wall mounted/ air circular fan) point controlled by one switchcomplete all as specified and directed.
32Material and Labour for Point wiring with 2 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 2 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One 3 Pin socket outlet 6 Amps socket on independent board complete all as specified and directed.
33Material and labour for Point wiring with 4 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 4 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity.
34Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one light point controlled by two Nos. two way switches complete all as specified and directed.
35Supply and fixing ceiling fan complete with blades, down rods, electronic regulator modular type, and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 sqmm form ceiling rose to connector of ceiling fan complete all as specified and as directed.
36Supply and fixingExhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, RPM 1200 copper winding of sweep 250 mm . fixed on wall making opening, fixing and making good the disturbed surfaces etc.complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed.
37Supply and fixing Exhaust fan AC single phase 230 Volt of size 300 mm sweep, steel body with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc.complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed.
38Supply and fixing Exhaust fan AC single phase 230 Volt of size 450 mm sweep, steel body with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc.complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed.
39S & F, Wall mounted fan AC single phase 230 Volt of size 400 mm sweepwith three blades & inbuilt regulator and framefixed on walland making good the disturbed surfaces etc.complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed.
40Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x1.5 sqmm for phase and neutral duly colour coded and 1x1.5 sqmm for earth continuity conductor green in colour complete for one 450 mm sweep exhaust fan pointcontrolled by one 06 amps modular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately.
41Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall/drawn along with truss, and PVC wire of size 2x1.5 sqmm for phase and neutral duly colour coded and 1x1.5 sqmm for earth continuity conductor green in colour complete for two Nos High bay light point controlled by one 06 ampsmodular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately.
42Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall/drawn along with truss, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete for three Nos High bay light point controlled by one 15 ampsmodular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately.
43Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
44Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
45Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x6 sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed
46Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x6 sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
47Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x10sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
48Supply and fixingEnergy efficient LED tube light fitting with tube 9 watts,lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
49Supply and fixingEnergy efficient LED tube light fitting with tube 10 watts,240V, 50hz surface mounted, with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
50Supply and fixingEnergy efficient LED tube light fitting with tube 20 wattsor nearest size ,240V, 50hz surface mounted,with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
51Supply and fixingLED high bay light fitting IP 65Energy efficient , environment friendly & robust IP 65 protected LED midbay with PDC housing suitable for ceiling (surface/suspended) mount & available in wide beam optics of 50 watts complete with mounting bracket etc. including connecting up all as specified and directed
52Supply and fixingLED medium bay/high bay light fitting IP 65Energy efficient , environment friendly & robustLED luminaire with high efficiency with toughened glass of 100 watts suitable for ceiling (surface/suspended) mount complete with mounting bracket etc. including connecting up all as specified and directed
53Supply and fixingLED medium bay/high bay light fitting IP 65Energy efficient , environment friendly & robustLED luminaire with high efficiency with toughened glass of 120 watts suitable for ceiling (surface/suspended) mount complete with mounting bracket etc. including connecting up all as specified and directed
54Supply and fixing LED Security light fitting30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and lens embedded PC cover having bottom opening separate driver compartment with IP66 protection pre wired and connecting upupto connector including 1.5 m long GI Tubing light grade of 32mmdia bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etc.complete all as specified and as directed.
55Material and labour for wall/floor mounted LT Panel board made out of CRCA sheet 2 mm thick indoor , CPRI approved, totally enclosed with frontopening, hinged doors, compartmentalised, weather and water proof with necessary locking arrangements along with lugs, danger notice plate, cable glands, stickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material incl Aluminium bus bar duly covered with heat proof colour code, insulators suitable for three phase and neutralLT AC, 50 Hz 415 V, 400 A capacity, complete with powder coated painting, necessary internal electric connection with suitable size coper wire, fitted with and inclusive following items:
56INCOMING : (a) MCCB 4 Pole, 415 V, Adjustable type variable range, 250 Amps,with O/L and short circuit protection, breaking capacity 25 kA - 01 No OUTGOING : (a) MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 16 kA - 01 Nos (b) MCCB 4 Pole, 415 V, 40 Amps with breaking capacity 16 kA - 09 Nos(01 spare) (c) MCCB 4 Pole, 415 V, 32 Amps with breaking capacity 16 kA - 05 Nos(01 spare) (d) MCP SPN 32 Amps, 240 Volt "C" curve - 09 Nos (e)Volt meter with selector switch 0 to 415 Volt - 01 No (f) Ammeter with selector switch and CTs 0 to 250 Amps - 1 No (g) LED phase indicator lamp for R Y B phases- 16 set
57M&L for earthing complete with galvanised steel plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip of 25mm x 4mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto panels, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and directed.
58M&L for earthing complete with galvanised steel plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 15 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and directed.
59COOLING APPLIANCES
60Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having nominal cooling capacity 40 litres/hour and storage capacity 80 ltr complete all as directed.
61Supply and fix water cooler electric driven (single phase), having approx. storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour all as specified and as directed.
62Supply and installed Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Vto 250 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 2.0 kVA
63TV & TELEVISION
64Supply and fix factory fabricated GI metal flush boxes suitable for 2 module complete all as specified and as directed.
65Supply and fix RJ 11 telephone socket 1 module withcoverplate complete all as specified and as directed.
66Supply and fix TV socket 1 module withcoverplate complete all as specified and as directed.
67M&LRigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees,bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., dia. of conduit 20 mm all as specified and as directed
68M&LRigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees,bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., dia. of conduit 25mm all as specified and as directed.
69Supply and fixing/drawing PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of make Havells or equivalent make Note :PVC conduit shall be measured separately.
70Supply and fixing/drawing of CATV co-axial cables (Electrolytic grade solid annealed copper conductor, jelly field, Aluminium foiled and aluminium wire braided)of Havells make or any other equivalent make Note :(i) PVC conduit shall be measured separately .Note :Prior to drawing of telephone conduits/TV conduits, the contractor shall take necessary approval of diagram from Engr-in-Charge.
71Supply and fix PVC junction box 20 mm complete all as specified and as directed.
72Supply and fix PVC junction box 25 mm complete all as specified and as directed.
73CHEMICAL EARTHING
74Material and labour for Chemical Earthing complete with copper earth plate electrode 90 cm x 60 cm x 5 mm thick buried directly in ground to a depth not less than 2.25 metre below normal ground level connected to copper strip of 32 x 6 mm earth lead with GI protection pipe 75 mm dia light grade connected to test point terminal block by means of bolts, nuts and washers of copper all as shown on plate No 3 of SSR Part-I to the extent applicable to this item including necessary excavation earth work PCC chamber in 1:3:6 type of C1 RCC cover slab, lifting handle, watering pipe of GI 20mm dia light grade, funnels wire mesh, chemical PRO-CEM and earth enhancing mineral compound meeting the requirement "As PER is - 3043" etc. testing on completion complete all as specified and as directed..
75Supply and fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc. as required for copper strips 32 X 6 mm with proper saddles / spacer, screws etc. all as directed.
76Supply and fixing steel tubing of light grade, galvanised, with all fittings and fixed complete to wall and ceiling or laid in floors of 40 mm bore complete all as specified and as directed.
77AIR CIRCULATORS
78Supply and install Air circulator fans dia 24 inch, 230 volts, 50 Hz, 1440 rpm,15000 CMH, single phase oscillating 600 mm sweep having 3 no of blades, with aluminium front and back false cover, high torque cast iron gear box with safety clutch, max temp rise 52 degC, suitable for wall mounting with all necessary arrangement all as specified and as directed.
79AVIATION LIGHT
80Supply and fix aviation obstruction light LED type 10 Wattincluding standard fixing arrangements complete all as specified and as directed.
81Supply and fix cable PVC insulated armouredPVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps spacers bolts nuts etc. all as specified and as directed
82Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure all as specified and directed.
83EXTERNAL WATER SUPPLY
84Material and Labourfor valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed.
85Cutting existing 150 mm steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 80 mmfor tapping all as specified and directed.(Tapping point shown)
86EXTERNAL ELECTRIFICATION
87Supply and fix lightning arrestor HT 11 KV 10 KA station classcomplete all as specified and directed.
88Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse having 12 insulators of rating upto 400 Ampscomplete all as specified and directed.
89Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 300 Sqmm
90Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 70 Sqmm
91Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 35 Sqmm
92Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 4 core 16 Sqmm
93Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
94Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:
95INCOMING: (a)MCCB 4 Pole, 415 V, 36 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 400 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. OUTGOING: a)MCCB 4 Pole, 415 V,36 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 250 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 02 Nos.(01 for bldg. and 01 spare) b) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 125 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos.(AC Plant Panel and spare) c) MCB SPN "C" curve 32A , 415 V, 50 Hz - 02 Nos (street lights and spare) d) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 63 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos.(01 for crane and spare)
96e)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs of each breakers f) Timer switch with control relay/contactor - 01 No g) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers
97Supply, install, testing and commissioning of factory made APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction [APFC] Panel of capacity of 60 KVAR with 2 steps (2 x 30) Compartmentalised, indoor type, fabricated as per IEC 61921 with 2 mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 35 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such asPower Factor Meter – 1 Nos, Digital type Ammeter of Range 0 to 250 Amps with CTs & Selector Switch – 1 Nos, Digital type Volt Meter of Range 0 – 500 V – 1 Nos, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete andpanel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed.
98Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering including tested on completion complete all as specified and as directed.
99Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure as directed.
100Supply & install steel tubular swaged poles Type 410 SP-31 (9.0 metres long) complete with CI base plate and finial and single swan neck including foundation(12 for street light, 03 for solar street lights) all as specified and as directed.
101Supply and fixing LED street light fitting 35/36 W 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
102Supply and fix Loop in loop out box (minimum size-200mm x 160mm x 98mm)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. all as specified and directed.
103Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 25 KVA complete all as specified and as directed.
104M & L for PVC insulated copper conductor of size 2.5 sqmm 3 core drawn through PVC pipe with clamping materials complete all as specified and as directed.
105M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less "than 1.5 metres below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
106M & L for steel tubes, "light grade", galvanised, 32 mm bore with all fitting bend to shape fixed to pole with one set of clamps of appropriate size all as specified and as directed.
107M & L for sub main wiring with 4 runs of single core 16 Sq.mm,single core , FRLS, PVC insulated, unsheathed, Multistrandedcopper conductor cable, 1100 volts, FRLS grade, ISI marked, for phase and neutral duly colour coded drawing through and including medium duty PVC conduit, 32 mm dia with all accessories concealed in walls/ roofs/ floors / ceiling etc. including one run of 16 Sqmm single core, FRLS PVC insulated, unsheathed, Multistranded copper conductor cable, 1100 volts, FRLS grade earth continuity conductor complete all as specified. Note: 4 runs of 16 Sqmm, 1 runs of 16 sqmm & one run 32 mm dia PVC conduit will be measured as one unit.
108Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size, for HT, 25x20 cm size all as specified and directed.
109AREA DRAINAGE
110Removal of excavated soil to a distance exc 250m and not exc 500m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified.
111SEWAGE DISPOSAL
112Material and labour for SFRC cover slabs (for manhole) with plain faces set in Cement motar 1:4 complete all as specified.
113LIGHTENING PROTECTION
114Material and Labour for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering including testing on completion complete all as specified and as directed.
115ROAD /CULVERT
116Material and Labour for painting lines, dashes, arrows, letters etc. on roads pavements and the like n.exc 10 cm wide with road marking painr , white or golden yellow complete all as specified as directed.
117FIRE FIGHTING SYSTEM
118Supply and lay ductile Iron flanged pipe, including specials, Class “K-9” ,150 mm (6”) dia conforming toIS-8329 in standard length suitable for push on rubber gasket complete all as specified and as directed.
119Cutting existing F/F pipe line for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 150 mmfor tapping all as specified and directed.
120FIRE ALARM
121Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
122Supply and fix LED EXIT light double sided with battery back up up to 2 Hrs. of operating voltage 230 V, 50 Hz complete with all as specified and as directed.
123DG SET
124Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 200 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-
125(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test
126(A) Alternator :-Standard design alternator rated at 200 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class "H" and voltage regulation of+/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 (i) Insualation class - "H" (ii) Temparature rise Class - "H" (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%
127(B) Diesel Engine: - Adequate capacity of Diesel engine as accepted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under (i)Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts (iii) Cooling Water pump : - Centrifugal type belt driven (iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
128iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters,Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
129ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
130x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine. xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling. xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xvi) MS pipe line to and from the fuel tank to the DG Set
131C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of200 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc
132g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
133f)Battery charger (i) Transformer shall be dry type, double wound, with copper conductor and Class–B insulation with temperature rise limited to Class-A insulation. (ii) Isolating switch shall be heavy duty, load break type, operated by an external handle. (iii). Fuses shall be HRC type and arranged for easy replacement. Semiconducting devices fuses shall be fast-acting type. (iv). Indicating meters (voltmeter and ammeter) shall be 96mm x 96mm, flush type 90 degree scale with antiglare glass, + 1% accuracy with zero adjuster on the front of the meter. (v.) The following indications/alarm annunciation shall be provided: a) Failure of input AC supply to the charger b) Low battery voltage c) DC output fuse blown d) Charger fail e) Over voltage f) Earth fault g) Battery on boost charge directed.
134(v) DC Ammeter (vi) Charger rate selector switch
135D) Accoustic Enclosure:-Manufactured by OEM suitable for 200 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment andPollution control board (iii) The generating setbattaries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms v) The accoustic should be composite in construction and fully assembled integral unit vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulatedplat form vii) The DG Set should be provided with external Emergency stop push button viii) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings. ix) The noise level should be 75 dba at 1m under free field conditions x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
136E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Setcomplete all as specified and directed.
137Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm dia by means of bolts, nuts, check nutsand washers of galvanised iron or steel usinggalvanised iron strip 32×6mm and 40 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipeas earthing leadall as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
138EOT CRANE
139Supply, installation, erecting, commissioning, and testing ofdouble box girder electrically operated OH crane, indoor type, 15 ton capacity with span 20 meter having lift 12 metre (approx.) and bay length 35.0 mtrs, AC 400/440 V, 3 phase, 50 Hz , Class-II Medium Duty M-5 as conforming toIS 807/3177 and IS : 3177-1999 with and including the following:
140(A) SPEEDS: (a) Hoist speed -2.0 M/MIN (b) Cross Travel - 7.0 M/MIN (c) Long travel speed - 10.0 M/MIN (B) Wire Rope construction- (a) 6 x 36 best plough steel fibre core R, H.D. lay per IS: 2266-1976 (b) No of falls - 8 falls (c) Factor of safety - greater than 6 (C) Bridge construction - Double web M.S. plate welded box type construction with adequate stiffeners and diaphragm and fusion welded. (D) End carriage and LT frame - fabricated out of M.S. section and plates with adequate diaphragm (E) End stoppers shall be provided on either side of the bridge to limit the motion of the trolley and on main LT rails, to limit and LT movement. (F) Full length platform on the driving side shall be provided. These platform shall be covered fully with antiskid chequered plates and provided with hand rails.
141(G) DSL system shall be G.I. shrouded bus bar system. (H) C.T. Trolley shall be made of all welded construction fabricated from rolled steel, sections and plates, hoist and cross traverse machineries shall be mounted on this frame. Entire trolley shall be fully covered all round with safety hand rails. (I) Rope Drum shall be fabricated out of low carbon steel as per IS: 2062 duly stress relieved of heavy duty seamless pipe constructionto accommodate wire rope in single layer. (J) Brakes:- a) Hoist Brake - 250 Dia thruster brake - qty -2 Nos b) Long travel brake- 150 Dia x 2 Nos thruster brakes c) Cross travel brake- 150 Dia thruster brakes K) Hook - Forged heavy duty steel standards single shank type plain hook as per IS 3815/3610. Materials shall be EN3 freely swivelling and supported on thrust bearing 360° swivel hook shall also be provided with spring loaded safety latch. L) Wheel: Wheels should be double flanged fabricated out of forged steel of EN-9 mounted on double bearings. M) Material of pinion : EN-9 hardness 250 to 300 BHN Material of gears : EN -8/9 hardness 250 BHN All necessary testing of the crane including SWL, overload and deflection shall be done all as specified and as directed.
142Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering including tested on completion complete all as specified.
143Supply and fix Galvanised iron strip 32x6 mm buried in ground /fixed to walls all as specified and as directed
Disclaimer :