Provision Of Joinery, False Ceiling And Certain E / M Fittings At Airmen Billet Of 10 Afh, Provn Of 5 Kva Ups In Major / Minor Ot And Icu, Iron Grill Gate For Hospital Bldg Entry And Exit Including It Cell Oxygen Plant And Ration Store, Iron Grill For, hasimara-West Bengal

Military Engineer Services-MES has published Provision Of Joinery, False Ceiling And Certain E / M Fittings At Airmen Billet Of 10 Afh, Provn Of 5 Kva Ups In Major / Minor Ot And Icu, Iron Grill Gate For Hospital Bldg Entry And Exit Including It Cell Oxygen Plant And Ration Store, Iron Grill For. Submission Date for this Tender is 04-03-2023. UPS Tenders in hasimara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

36223333
Corrigendum : Provision Of Joinery, False Ceiling And Certain E / M Fittings At Airmen Billet Of 10 Afh, Provn Of 5 Kva Ups In Major / Minor Ot And Icu, Iron Grill Gate For Hospital Bldg Entry And Exit Including It Cell Oxygen Plant And Ration Store, Iron Grill For
Open Tender
Indian
West Bengal
hasimara
04-03-2023

Tender Details

Provision Of Joinery, False Ceiling And Certain E / M Fittings At Airmen Billet Of 10 Afh, Provn Of 5 Kva Ups In Major / Minor Ot And Icu, Iron Grill Gate For Hospital Bldg Entry And Exit Including It Cell Oxygen Plant And Ration Store, Iron Grill For Ht Tank For Hospital And Airmen Mess At 10 Afh, Provn Of Certain E / M And B / R Work For Tech Accn At Af Stn Hasimara Under Ge ( Af ) Hasimara

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Feb-2023 CORRIGENDUM TO TENDER Other 04-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
Refer document

BOQ Items

Nature of Work : PROVN OF JOINERY, FALSE CEILING AND CERTAIN E/M FITTINGS AT AIRMEN BILLET OF 10 AFH, PROVN OF 5 KVA UPS IN MAJOR/MINOR OT AND ICU, IRON GRILL GATE FOR HOSPITAL BLDG ENTRY AND EXIT INClUDING IT CELL OXYGEN PLANT AND RATION STORE, IRON GRILL FOR HT TANK FOR HOSPITAL AND AIRMEN MESS AT 10 AFH, PROVN OF CERTAIN E/M AND B/R WORK FOR TECH ACCN AT AF STN HASIMARA UNDER GE(AF) HASIMARA
Sl. No. Item Description
1Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
2M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
3M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
4All as per item No. 3 above but for ornamental and intricate design work, complete all as specified and directed.
5M&L forapplying two coats of synthetic enamal paint (1st grade quality) over a coat of red oxide zinc chrome primer on new steel surfaces including preparation, over 10cm in width or girth, not otherwise described, complete all as specified and directed.
6M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specifed and directed
7M&L for rendering 15mm thick in CM (1:4) onbrick/stone masonry surfaces finishing even and smooth without using extra cement, complete all as specified and directed.
8M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces, complete all as specified and directed.
9M&L for preparing old plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old plastered surfaces, complete all as specified and as directed.
10Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required depth exc half brick and not exc one brick,complete all as specified and directed.
11S&F MS rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp & staple & one shop coat of primer, erected in position as indicated, complete gear operated type with bevel gear box & crank handle, thickness of laths 1.25mm,complete all as specified and directed.
12S&F in repair toughened glass 12mm thick incl necessary itching for logo with arrangement of one D/L shutter with fixing ofH type handel SS finish 25mmx450mm (2 Nos) in each shutter for each panel position, one SS lock push bottom type, 2 floor spring along with non toxic/odourless silicon gel around the junction, complete all as specified and directed
13S&F standard SS patch fitting for side glass panel and glass door incl necessary fixing arrangements, complete all as specified and directed.
14S&F for 12mm thick seamless calcium silicate ceiling made of 1800x1200mm size board of silicious and calcarious materials reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having philips head with under head and cutter at 200mm centre to centre including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finishing with primer and two coats of oil bound distemper, complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately)
15S&F for anodised aluminium for seamless ceiling comprising of Al perimeter channnel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre.along with wall suspended with and including GI stripas in suspenders of ceiling members fixed in proper position, complete all as specified and directed.
16S&F powder coated aluminium three track sliding window with frame using standard medium weight Jindal sections of weight not less than 0.55 Kg/m excluding glazing with 4.8mm thick sheet glass stainless steel wire cloth (1.40mm aperture and 0.63mm dia) aluminium snap beadings, but including decogrill DG-102 and F channel etc, complete all as specified and directed.
17S&F for 4.8mm thick tinted sheet glass glazing with and including rubber gasket not exc 0.50 Sqm in each pane, complete all as specified and directed.
18S&F inaluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staple, complete all as specified and directed.
19S&F power coatedaluminium window & ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc, complete all as specified and directed.
20S&F figured glass 3.0mm thick, pin head type & glazing with oil putty in squares n. exc 0.5 Sqm in each pane, complete all as specified and directed.
21M&L for providing cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
22M&L 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
23M&L for preparing new plastered surfaces by applying two coats of distemper oil emulsion over a coat of primer on surfaces of walls, complete all as specified and directed.
24Refixing in other opening frame exc 1.5 Sqm but n.exc. 4 Sqm in each with shutters (without taking off shutters from the frame)(aluminium frame cum shutter), complete all as specified and directed.
25S&F stainless steel 25mmdia powder coated fancy typecurtain rod with brackets, of any length fixed in repairs, complete all as specified and directed.
26M&L for non asbestos, fibre reinforced designer board ceiling, 4mm thick (610mm X 610mm) with hot-dip GI heavy duty suspended ceiling grid system T-2430 with GI frame work for seamless ceilling comprising of GI perimeter channel, unequal flanges and web etc of suitable size suspended from soffit at approx 900mm center with GIO cleat and steel expansion fastner with and incl ceiling section incl hangers of 6mm dia GI, fixed to roof by means of ceiling cleats made out of GI flat, all as per manufacture"s instructions, complete all as specified and directed.
27S&F for anodised aluminium frame for doors,windows, ventilators with one or morerebates including joining cleat for fixing etc including powder coating (minimum thickness of powder coating 50 micron), complete all as specified and directed.
28S&F for anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. powder coating of any colour, complete all as specified and directed. (Thickness or powder coating not less than 50 micron)
29S&F for anodised aluminium partitions,aluminium section including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. powder coating of any colour, complete all as specified and directed. (Note :- Aluminium section weighing 1.175 kg/m and area of each box not exc. 0.60 Sqm) complete all as sepcified. (Thickness or powder coating not less than 50 micron)
30S&F 3mm thick PVC tiles/sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in vertical surface, complete all as specified and directed.
31S&F aluminium mortice lock, vertical type, size 100mm (2 levers), complete all as specified and directed.
32M & L for 6.3mm sheet glass, ordinary quality, in squares exc 0.5 Sqm in each pane, complete all as specified and directed.
33Taking down cement plaster of any description any thickness incl racking out joints hacking for keys scrubbing down with water etc and rubbish off the premises, complete all as specified and directed.
34Material and labourrendering 10mm thick plaster in CM (1:6) on fair faces of brick or concrete surface finished even and smooth without using extra cement, complete all as specified and directed.
35M & L for applying 2mm thick wall care putty on wall finished, complete all as specified and directed.
36M & L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over one coat of priming paint, complete all as specified and directed.
37Supply, installation and testing and commissioning of 5 KVA online UPS with CRCA enclosure, IP 41, input voltage : 160-260 Volt AC Single phase, frequency : 50Hz+6%, output voltage : 230Volt + 1%, Fequency : 50 Hz, Power factor 0.8, including2 Volt sealed maintenance free battery bank with suitable number of battery to cater the fullload for 60 minute minimum back up time for5 KVA UPSalong with FRP madebattery rack/stand with adequate shelf as required to accomadate all battery including connection from UPS to battery with suitable connectorcompletemicroprocessor based display for I/P & O/P voltage, DC Voltage output, frequency, % battery back up etc, LED indicators for mains on, battery on, charge, low battery imminent, load in inverter, load in auxillary supply etc, electrical protection, input/output/under volt, over temp, over load, short circuit and battery low trip, surge protection, inbuilt over voltage cut off device etc, inbuilt isolation transformer between UPS out put and supply mains, intergration of UPS with battery bank, UPS should have multi line LCD display which shall show various status parameters of system and UPSshallgive district audio signals/alarms for battery mode low battery or other faults etc.,complete all as specified and directed. Make : Blue Bird, Exide, Microtek or equivalent make approved by GE.
38M & L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6.0Sqmm drawn through in and including rigid PVC casing caping surface typeincluding 6.0 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals, complete all as specified and directed. Note:- (i)Threeruns of 6.0 Sqmm cabledrawn in casing capingshall be measured as one length of sub main wiring. (ii)Casing capingand its accessories deem to be included in this item rates. (iii) Unit rate include for cutting walland making holes making good to wall, ceiling etc.
39Supply and fixing MCB, SPN 63 Amp, 10 KA "C" curve complete with connection testing and commissioning, complete all as specified and directed.
40S & Fdistribution board SPN 4way for MCBs fitted with bus bar, neutral link, earth bar and din rail suitable for use on 240 V, 50 Hz supply double door (for toilets and corridoor), complete all as specified and as directed.
41M&L for point wiring with 1100 V grade with 1.5 Sqmm single core PVC insulated unsheathedFRLSHcable, copper conductor multistrandedpassing through and including concealedPVC conduit not less than 20mm dia with concealed modularboxsuitable for logic modular switches , sockets , etc and logic modular white plates, sorroundingsof suitable sizeas required atsitewith PVC insulated FRLSHunsheathedstranded copper conductor of size 1.5 sqmmas earth wireconnected to common earthdolly as specified for one light/fanpoint controlled by one, one way switch single pole, complete all as specified and directed. Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good tothe walls (No extra payment shall be made for the same) (ii) Provision of blank plates as per site requirement (No extra payment shall be made for the same)
42All as per ser item No. 41 here in before but one 5 pin 5 Amps socket point on the sameboard with other switches including earth wire, complete all as specified and directed.
43All as per ser item No. 41 here in before but on independent board, complete all as specified and directed.
44All as per ser item No. 41 here in before but with 4 SqmmPVC copper stranded cable FRLSH type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLSH type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes, complete all as specified and directed.
45M& L for Point wiring with 1.5 SqmmPVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including PVC conduitmedium grade (ISI marked) ofsize not less than 20mm dia on wall /floor /surface type /though existing conduit on ceiling and its connectedaccessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thickplastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5Sqmm (nominalarea) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end for one light point/one fan point controlled by one, one way swtich single pole, complete all as specified and directed. Note:-Unit rate include for cutting chases for conduits and sinking of boxes andmaking good to wall, floors etc.
46All as per item No. 45 here-in-before one 5 Amp 3 pin socket point on the same board, complete all as specified and directed.
47All as per item No. 45 here-in-before one 5 Amp 3 pin socket point on independent board, complete all as specified and directed.
48All as per item No 45 here-in but with 4.0 Sqmm cable and 4.00 Sqmm earth continuity conductor for 3 pin/5 pin 15 Amp sockect, complete all as specified and directed.
49Supply and fixing switch modular type, single pole, one way, 5/6 Amp, one module, complete all as specified and directed.
50Supply and fixing switch modular type, single pole, one way,15/16 Amps, one module, complete all as specified and directed.
51Supply and fixing socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, two module, modular type, complete all as specified and directed.
52Supply and fixing socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp, modular type, complete all as specified and directed.
53Supply and fixing fan step regulator modular type, two module, complete all as specified and directed.
54M & L for switch piano flush button single pole one way 6 Amps 240 volts, complete all as specified and directed.
55M & L for socket outlet 2 in 1, 3 pin 6 Amp flush type, complete all as specified and directed.
56M & L for switch and socket combination 5 in 1. 6 Amp/16 Amp flush type, complete all as specified and directed.
57Supply and fix ceiling fan complete with down rod and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified anddirected. Make :- Havells/Khaitan/Usha/Orient
58Supply and fix galvanized iron (medium grade) 40mm pipes with complete fittings such as bends, tees, elbows, reducers, flanges, fixed inside the wall horizontally below the ceiling level for hanging the ceiling fan and fix the necessary fan hooks/accessories for fitment of ceiling fan etc., complete all as specified and directed.
59S&F ceiling rose of size 65 x 50mm surface bakelite 240 Voltsthree terminal, complete all as specified and directed.
60S & FLED luminaire 600mm x 600mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size, complete all as specified and directed.
61S&F MCB DB SPN double door 08 way, IP 43 protection fixed on wall, complete all as specified and directed.
62S&F RCBOs for earth leakage, over load and short circuit protection 32 Amp DP 100 mA, complete all as specified and directed.
63Supply & fixing MCB SP of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed.
64Supply & fixing MCB SPN of capacity 6 to 32 Amps, 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed.
65Supply and draw sub main wiring of two run of 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, drawn through and including concealed type and accessories of not less than 25 mm size (ISI marked) including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of4.0 sqmm single core PVC insulated unsheathed copper earth continuity conductor (FRLSH), complete all as specified and directed. (Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length) the quoted rate is including making good disturbed surfaces.
66Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation, laying of cables, pipes in trenches, etc, and getting out in soft/loose soil, complete all as specified and directed.
67Returning filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm thick for soft/loose soil, complete all as specified and directed.
68Removing excavated material exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point in soft/loose soil, complete all as specified and directed.
69Materials and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 50 Sqmm 3.5 core, complete all as specified and directed. Note : Excavation and earth work shall be measured and paid separately under respective items.
70Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mmdia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
71Boring of holes under road, pavement, hard standing, runway & PTT by trenchless technology using ultra sounding technique and necessary machine including DWC pipe of 100mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed. Note: An amount of Rs.6500.00 on account of credit schedule for schedule "A" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
72Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips
Disclaimer :