Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #36222659

Tender For Construction Of Deficient Living In Accommodation For Airmen And Ncs E At Afs Borjhar

Issued by Statutory Bodies & Commissions/Committees · borjhar, Assam
Tender Value
16 Crore
Estimated cost
Bid Submission
20 Jun 2023
0 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
borjhar → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Deficient Living In Accommodation For Airmen And Ncs E At Afs Borjhar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Mar-2023 Corrigendum_1 Date 15-Apr-2023
2 10-Apr-2023 Corrigendum_2 Date 01-May-2023
3 25-Apr-2023 Corrigendum_3 Date 22-May-2023
4 16-May-2023 Corrigendum_4 Date 06-Jun-2023
5 30-May-2023 Corrigendum_5 Date 20-Jun-2023

BOQ

Name of Work: CONSTRUCTION OF DEFICIENT LIVING IN ACCOMMODATION FOR AIRMEN AND NC’S (E) AT AFS BORJHAR
Sl. No. Item Description
1SCHEDULE \"A\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:-
2Construction of Triple Storey Building for Cpl and below including pile foundation RCC framed structure complete all as specified and as shown on drawings. (80Nos Cpl and below, One Block)
3Construction of Double storey Building for Surgent and above RCC framed structure complete all as specified and as shown on drawings. (40 Nos SGT & above, One Block)
4Construction of Single storey Building for Havilder RCC framed structure complete all as specified and as shown on drawings. (07 Nos Havilder, One Block)
5Construction of RCC over head storage tank ( RCC framed structure ) of 25000 gallons capacity of 18.40 m staging height complete all as specified and as shown on drawings.
6SCHEDULE \"A\" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
7SCHEDULE \"A\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents.
8SCHEDULE \"A\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents.
9SCHEDULE \"A\" PART- V (ROAD/PATH/CULVERT)Details of prepriced Schedule is given in tender documents.
10SCHEDULE \"A\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents
11SCHEDULE \"A\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents
12SCHEDULE \"A\" PART- VIII (EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents
13SCHEDULE \"A\" PART- IX(EXTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents.
14SCHEDULE \"A\" PART- X(COOLING APPLIENCES)Details of prepriced Schedule is given in tender documents
15SCHEDULE \"A\" PART- XI(HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents
16SCHEDULE \"A\" PART- XII(DEMOLITION /DISMANTLING)Details of prepriced Schedule is given in tender documents
17SCHEDULE \"A\" PART -XIII (MISCELLANEOUS ITEMS)Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" F \" signifies this fact only.
18SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORKM&L for bringing approved earth as stipulated in 3.22.6 of SSR (Part-I) from outside MD land distance beyond 5 KM but not exc 10 KM and forming embankementincluding spreading in layers n. Exc. 30 cm thick, watering, ramming/ rolling with 8 to 10 tonne power roller to achieve OMC dry density 95 % and finished to required gradient/level, size and shape etc, complete all as specified and as directed.Note:- (i) Payment shall be made for solid quantity arrived after consolidation.(ii) Before execution of this earth shall be tested/ checked for suitability to use. (iii) Quoted rates shall be inclusive of all taxes and royalities.
19Internal ElectrificationS&F switch socket combination, 2 in 1, 6 pin, 20 amps flush type, universal complete all as specified and as directed.
20Supply andfixing for 450 mmsweep wall fan withosilation mechanism3 speed pullchordcontrol,bladeetcincludingfixingonwallby holefastnerarrangement including connection etc with flexible copper wire for connections from ceiling rose or connector to wall fan complete all as specified and as directed.
21Supplyandfixingfor1x20watt,LEDtubelight 4 feetindoordecorativealuminium extrudedLEDbattenintegratedbattenT8fitting230Vwithallaccessories,led lamp, connector block,prewired and including connecting up with twin core twisted flexible copper conductor of suitable size compete all as specified and as directed.
22Supplyandfixingfor1x10watt,LEDtubelight2 feet, indoordecorativealuminium extrudedLEDbattenintegratedbattenT5fitting230Vwithallaccessories,led lamp, connector block,prewired and including connecting up with twin core twisted flexible copper conductor of suitable size compete all as specified and as directed.
23Supplyandfixingfor1x35WattLEDpressurediecastaluminiumhousingLED security street light lumaniare fittings with IP 66 protection powder coated and suitable for workingwith230Volts,ACSupply withallaccessorieswithandincludingLED lampandnecessaryelectricconnectionwithusingrequiredsize coppercable complete all as specified and as directed.
24Supply and fixing for 1x10 Watt white LED lamp of 240 Volt complete all as specified and as directed.
25Materials and labour for earthing complete with galvanised iron earth plate electrode600mmx600mmx6mmthick,burrieddirectlyandpreferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with topedgeoftheplatenotlessthan1.5mbelowgroundlevelconnetcedwith galvanisedearthwireofsize 4mmdiaby meansofnuts,bolts,checknutsand washersmadeofgalvanisedironorsteelearthingleadtobeprotectedby galvanisedironpipe40mmbore(mediumgrade)andotherendconnectedto earthingtestpointorlighteningarrestorormaincontrollingswitchasdirected including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh,charcoal orcokeandcommonsaltinalternatelayerof15cm(compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with20mmgradedaggregate),50mmthickprecastRCC(1:2:4)coverslab(re- inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of10mmdia)includingnecessaryearthworkinexcavation,returningfillingand removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed.
26ROAD/PATH/CULVERTM & L for 200mm thick GSB (Granular sub-base) grade V of table 400-I of MORTH, IRC specification spreading in layers not exceeding 150 mm thick watering, ramming / rolling by tandem vibrator rollerand finish to longitudinal gardiant (1:150) & transvers gradient (1:100) and required camber for achive field compaction at least 98% of MDD (maximum dry density) determined using modified procter density determination method as per IS code complete all as specified and as directed.
27M & L for Bituminous premix semi dense asphaltic concrete of 40 mm consolidated thickness with 6% binder content by weightr of total mix (using bitumen Vg-30), rolled and compacted to required camber and gradient complete all as specified and as directed.
28Internal Water supplySupply and fixing for 15mm bore stop cock CP high pressure with capstan head long shank screwed down for iron pipe complete all as specified and as directed
29Cooling AppliancesSupply and install voltage stabilizer automatic operation, single phase, naturally air cooled, AC supply 50 cycle, indoor type wall or floor mountedand designed for input variation between 170 Volt to 260 Volt with and output voltage stabilzed at 220V with accuracy + 2.5% and capacity 1 KVAwith time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
30Sewage disposal.Construction of Septick tank for 30 usersLLDPE conventional type, designed to carry out sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent, shat connection etc complete all as specified and as shown on drawings.
31Construction of Septick tank for 100 usersLLDPE conventional type, designed to carry out sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent, shat connection etc complete all as specified and as shown on drawings.
32Construction of brick masonary Soakage Well for 100 users complete all as specified and as shown on drawings.
33Construction of brick masonarySoakage Well for 30 users complete all as specified and as shown on drawings.
34EXTERNAL WATER SUPPLYS&F centrifugally cast (spun) Ductile iron pressure pipes of size 100 mm with socket and spigot-END, Class k_9 conforming to IS:8329/2000 suitable for (push one rubber gasket joint of 100mm bore including rubber gasket 9push on) and laid in trenches complete all as specified and directed. Make: Electrosteel/ Electrotherm/ TATA/ Jay Balaji/ Rashmi. Note: The inner surface of pipe should have cement mortar lining with sulphur resistant cement and outer surface should have metallic zinc coating with finishing coat of black bituminous paint complete all as specified and directed.
35M&L for Cutting CI pipe of 150 /100 mm and measuring tee of size 100 x 100 x 50 mm bore and 01 no of size 100 mm bore complete all as specified and directed.
36M&L construction of brick masonry valve chamber of size 900mm x 900mm x 900mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting ot MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
37M&L construction of brick masonry valve chamber of size 600mm x 600mm x 600mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting ot MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
38M&L Trial bores of 250 mm dia upto 200 mtr depth below GL in any kind of soil/starter all as specified and directed.
39Development of trial bores by reaming as follows :-
40Reaming upto 675 mm for 60 RM from ground level including casing pipe of 350mm dia and thickness 8mm and pea gravel.
41Reaming upto 525 mm from depth exceeding60 RM to 200 RM from ground level including casing pipe of 250mm dia and thickness 8mm and pea gravel.
42Cost for MS reducer, bail plug, well cap, MS etc strip for centring, MS iron clamps, electric logging and sample strata box.
43Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water.
44Yield test for bore well by continously pumping for 16 hours to determine safe pumping yield.
45Additional Cost for slotted pipe of 250mmdia in lieu of casing pipe of 200 mm dia
46Supply,installed,Testing and commissioning of Submersible pumpset electric driven 415 V 3 phase suitable for 250 mm dia borewell (casing pipe size 200/250mm) supplied complete, of minimum discharge capacty 400 LPM and head 60mtr.
47Supply, Install, testing and commissioning of Catalytic type of Iron remover plant 10000 gph with prefilter suitable for raw water having iron content 10 mg/lit bring it to less than 0.3 mg/lit acceptable standard of potable water and testing chemical analysis of treated water from approved Govt laboratory , complete with face piping valves, filter and catalytic media, under bed plate system fitted with PVC Strainer, pressure gauge,Venturi, manholes, air vent system, coagulant feeder, chlorine dosing unit, Air Compressor of suitable capacity forback washcomplete all as specified and directed by Engr-in-charge with following specifications:-a.Iron Removal cum pressure filtration plant 10,000 GPH size: 2500 mm dia x 1500 mm ht shell th:08 mm x 10 mm x 12 mm complete with filter media, live catalytic media, under bed plate system with PVC strainer, back washing facilities with all other necessitates accessories - 01 set b. Oxidation chamber size: 1000 mm dia x 1200 mm ht with full charge of catalytic media - 01 set c. Cast Iron Butter Fly valve flange less finish 100 mm – 05 nos d. Frontal pipe line M S fabricate 100 mm – 01 set e. Suitable air compressor for proper aeration and back wash - 01 no .
48Supply,install,testing and commissioning of Altoch dosing system having dosing pump with suction line Strainer,Injection line strainer.Injection check valve ,Suction/Discharge tubing, capacity 2USGPD to 40 USGPD at 100 PSI and Solution solution preparation tank capacity of 100 Litrs complete all as specified.
49S&F Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors of size 6 sqmm 3 core 1100 volt, confirming to IS 694 complete all as directed.
50Supply and fix fully automatic star delta starter for 15 HP Motor in IP65 sheet - steel enclosure with single phase protection feature (motor rating AC-3 Duty, 415V, 50 Hz, 3-Ph), Relay Max Range 9-15A, MN16FASD complete all as specified and directed.
51External ElectrificationM & L for PCC cable route marking of 150x50x600 mm for under ground cable complete all as per specified and directed.
52Material and labour for FPB(CPRI approved) made out of black sheet 3.15 mm thick, angle iron1.2X1X.45 mtr complete with 400 amps4 Nos aluminium bus bar and incoming/outgoing MCCB (as below) :-( For pump )(a) Incoming - MCCB 4 pole, 415 volt, 125 Amp (25 KA) rating(b) Outgoing - (i) MCCB 3 pole, 63 Amp (18 KA), 415 volts - 3 Nos(c) On load change over 100 amps capacity =01(d) MCB SPN32 Amps415 volts - 01 Nos(e) LED indicating lamps for main supply indicating capacity (f) LCD Multifunctional meter.
53Material and labour for FPB (CPRI approved) made out of black sheet 3.15mm thick, angle iron1.2X1X.8 mtr complete with 400 amps4 Nos aluminium bus bar and incoming/outgoing MCCB (as below) :-(a) Incoming - MCCB 4 pole, 415 volt, 250 Amp (35 KA) rating(b) Outgoing - (i) MCCB 3 pole, 125 Amp (25 KA), 415 volts -6 Nos(c) MCB SPN32 Amps415 volts - 01 Nos.(d) LED indicating lamps for main supply indicating capacity (e) LCD Multifunctional meter
54M&L for Machinery /Equipment/chemical earthing complete with copper earth plate 90x60x5 mm burried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised iron earth lead by means of bolt,nut as shown and washer of copper strip 50x6 mm as earthing lead earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil,earth pit in PCC 1:3:6 type C1 using 20 mm stone aggregate funnel,20 mm dia GI med grade water pipe,15 mm dia GI light grade earth lead protection pipe ,CI frame and cover, wire copper lugs,wire mesh,charcoal or coke and common saltin alternate layers all around the earth electrode pit cover including disposal of surplus soil to a distance not exceeding 50m,complete testing on completion all as shown in electrical plate no of SSR part No 1 all as directed.
55Supply & fixing IP 65 thermoplastic-polycarbonate pole box with terminal and MCB Single Pole 6 amps, which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technologycomplete all as specified and directed.
56Supply and fixing bracket for street light fittings of any size made out of GI pipe medium grade 40 mm dia 1.5 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified and directed.
57Laying only old bricks for protection of UG cable complete all as specified and directed.(Note : Serviceable bricks obtained from taking down of UG cable shall be resued).
58COOLING APPLIENCES Supply and fixing for voltage stabilizer automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170 Volt to 250 Volt with and output voltage stabilzed at 230V with accuracy + 2.5% and capacity 1KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
59Note:- Schedule of credit (Sch \"A\" Part- XIV) amount of Rs 6,24,384.00 shall be deducted from the total quoted amount of BOQ.

AI Tender Summary

OUR REF NO 36222659
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 16 Crore
LAST DATE 20-06-2023
Authority
Authority Name Military Engineer Services
Work Description Construction Of Deficient Living In Accommodation For Airmen And Ncs E At Afs Borjhar
Basic Detail
Tender No 88365/BOR
Bidding Type Tender
Location
City borjhar
State Assam
Key Dates
Publish Date 30 May 2023
Submission Date 20 Jun 2023
Open Date 22 Jun 2023
Finance
Tender Value 16 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Not Available
Document List
71f67c69-6af2-4f52-9da1-bf3007d9584c.html
BOQ_650185.xls
TD1.rar
TD2.rar
Tender.pdf
Tendernotice_1.pdf
Working.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 30, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 15, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 01, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 22, 2023
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 06, 2023
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 20, 2023
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 20, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 22, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

71f67c69-6af2-4f52-9da1-bf3007d9584c.html

xls

BOQ_650185.xls

rar

TD1.rar

rar

TD2.rar

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

rar

Working.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders