Department Of Agriculture-DOA has published Tender For Supply Of Essential Machinery For Establishment Of Plant Leaf And Tissue Analysis Laboratory. Submission Date for this Tender is 25-02-2023. Stationery Tenders in latur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36218284
Tender For Supply Of Essential Machinery For Establishment Of Plant Leaf And Tissue Analysis Laboratory
Open Tender
Indian
Maharashtra
latur
25-02-2023

Tender Details

Supply Of Essential Machinery For Establishment Of Plant Leaf And Tissue Analysis Laboratory- 1 Atomic Absorption Spectrophotometer ( Aas ) :-External Pc-Controlled New Generation Fully Automated Double Beam Optics Atomic Absorption Spectrometer Fitted With Fully Automated 8-Lamp Turret With Automatic Alignment With Strong Deuterium Background Correction For Analysis Of Cu, Fe, Zn, Mn, As, Hg, Pb, And Mo. Lamp Turret Should Have Independent Power Supply To Each Lamp Each With Two Heating Circuit For Lamp Preheating Operation. The Turret Must Have Comparability For Lamps From Other Aas Manufacturers.The System Should Have Both Single & Double Beam Optics With Optional Purge Function For Improved Uv Transmission. All Optics Should Be Quoted With Proactive Seal And Double Sealed With Special Light Proof Cover For Enhanced Stray Light Rejection And Prevention Of Dust Contamination.Monochromator: High Energy Czerny Turner Monochromatorwavelength Range: 185-900 Nmgrating: Holographic Grating With 1800 Lines / Nmslit Selection: Automated Slit Selection With 0.2, 0.5, 0.8 And 1.2Nmfocal Length: 389 Mmdetector: Solid State Detector Siosens, Is Most Sensitive Detector And Is Used In Only High Endequipment’S Like ( Icp Oes. ) Wide Range, Linear Read Out 0.1 100%, Low Noise Csa, 5 V Background Correction: The System Should Have Ultra-Fast ( 300Hz ) D2 Background Correction With Superior S / N Ratio And Identical Absorption Profile Of D2 And Element Lamp.Flame System: System Should Highest Safety Standard With Coded Burner Heads, Sensor Control Of Flame, As Type And Pressure, Pressure Relief Valve In The Spray Chamber, Siphon Sensor Control & Uv Sensor For Flame Detection. Automated Height Adjustment Of The Burner Head, Emission Mode With Baseline Correction Possibility. Gas Control: Automatic Control & Optimization ( Flow / Pressure ) Safety Measures: Gas Leak Check, Prevention Of Gas Release System Must Have Universal All Titanium 5 Cm Burner For Both Air / Acetylene And Acetylene / N2o Flame.The System Should Have Fully Computer Controlled Total Flow Gas Box With Dual Fuel And Oxidant Monitoring For Stable Control Of Fuel / Oxidant Ratio.Hg / Hydride-System. System Should Be Offered With Computer Controlled Dual Pump Hg / Hydride-System For The Determination Of Hydrideforming Elements In Μg / L Range With Electrically Heated Cell Module ( Up To1000oc ) Asstandardconfiguration.Itshouldalsohave Facilityforupgradationwithautomatedburnercleaningand Micro Volume Injection.Theaasshouldhaveeasy, Reproduciblechangebetween Burner Head And Cell Module With Quick-Lock. High Specialized Aas Software Package With Excellent And Exhaustive And Cook- Book Should Be Included. Software Should Have Options For Automatedoptimization Of Gas Composition Andburnerhead Position For Method Development Of Unknown Samples.The Aas Should Be Supplied With 2 Year Warranty Against All Manufacturing Defects. All Local Scope Of Supplies Like Pc & Printer, Hood, Gases, Regulators, Plumbing And Air Compressor Required For Installation And Operation Of Aas To Be Mentioned And Quoted Separately. This Instrument Is Supplied With Fume Hood. 2 Double Beam Spectrophotometer Double Beam Uv- Vis Spectrophotom Eter With 10Mm 8 ( Eight ) Place Cuvette Cell Holder With Spectral Band Width : Variable 0.5 / 1 / 2 / 4 / 5 Nm :- Highresolutionmonochromator, Seya-Namiokamount Wavelength Range: 190Nm - 1100Nm Spectral Bandwidth: Variable 0.5 / 1 / 2 / 4 / 5Nm Cuvette Holder:10 Mm8 ( Eight ) Place Cuvette Cell Holder Wavelength Accuracy: + / - 0.1Nm@656.1Nm, + / -0.3Nm@Allwavelengthrepeatability:-<=0.1Nmwavelength Accuracy:-: 0.2%T ( 0-100%T ) , + / - 0.002A ( 0-0.5A ) , + / -0.004A ( 0.5- 1A ) Wavelength Setting:-Autophotometric Repeatability::+ / - 0.15%T ( 0- 100%T ) , 0.001A ( 0-0.5A ) , 0.002A ( 0.5-1A ) Stray Light :-: <=0.03% T@220Nm, 360 Nm Photometric Range:-: 0-200%T.- 0.3-3A, 0-9999C ( 0-9999F ) Straylight:+ / -0.0003A / H@500Nm Wavelength Scan Speed: Auto Response: Fast, Medium, Slow Baseline Stability: 0.001 A Noise Level: 0.0005A@500Nm Work Mode: -T, A, C, E Baseline Flatness: 0.0001A Detector : Imported Silicon Photodiode Display: 10.1” Tft Colored High Quality 3 Flame Photometer With Pc Link Software And With Compressor:- • Micro Controller Based Automation For Ease Operation •Determination Up To Four Elements With Single Aspiration ( Na, K, Li & Ca ) • Curve Fitting Correction For Non Linear Emisiion Characteristics Of Elements At Higher Concentration , Maximum Five Point Calibration • Storing Facility For Setups And Results ( Date Wise & Batch Wise , Maximum 700 Results ) The Same Can Be Recalled Whenever Need Arise . • 4 Line 20 Character Lcd Readout • Facility For Restandardization With Single Standard • Built In Real Time Clock For Date And Time Analysis • Printout Facility For Individual Sample , Batch Sample , Total Days Samples Or Entire Results In The Memory ( 700 Max ) • Air Compressor With Built In Air Regulator And Air Filter • Pc Link Software For Transferring Data To Computer And Manipulation Of Data In Computer Using Rs-232. • Reproducibility : : Low Conc : Plus Or Minus 1% Fs , High Conc : Plus Or Minus 2% Fs. • Minimum Smaple : 3Ml / Element ( Approx ) • Averaging Time : 2 To 15 Seconds • Operating Air Pressure : 0.45 Kg / Cm Square • Air Compressor : With Built In Air Regulator And Air Filter To Deliver Stable And Moisture Oil Free Supply With Pressure Of 1 Kg / Cm Sqaure. • Printer Port : Epson Compatible 80 Column Dm Printer • Rs-232 Port : Pc Link Data Transfer • Memory : Storage 700 Results • Power : 230V Plus Or Minus 10% , 50 Hz • Dimensions : 415 ( W ) X 255 ( D ) X 305 ( H ) Mm ( Main Unit ) , 255 ( W ) X 210 ( D ) X 205 ( H ) Mm ( Compressor ) • Weight : Main Unit 6.5 Kg + Compressor 6 Kg • This Instrument Is Supplied With Pc Link Software. This Instrument Is Supplied With 4 Filters That Is Na, K, Li & Ca 4 Ph Meter 5 Point Calibration :- Display Capacitive Touch Screen With Resolution 1024*600 Ph ? Measurement Range :- ( -2.000 - 19.999 ) Ph ? Resolution :- 0.01 / 0.001Ph ? Accuracy :- + / - 0.01Ph ? Input Current :- < 1X10- 12 A ? Input Impedance :- > 1X10 ? Stability :- + / - 0.01 Ph / 3H ? Temperature Compensation :- ( 0-100 ) C ( Auto Or Manual ) Mv ? Measurement Range ( Mv / Orp / Eh ) :- -1999.9Mv~0~1999.9Mv ? Resolution :- 0.1Mv ? Accuracy :- + / - 0.03%% Fs Temperature ? Range :- -10C ~ 110C ? Resolution :- 0.1C ? Accuracy :- + / - 0.5 C Calibration Automatic ( 1, 2, 3Points ) , Niststandards Others ? Data Storage : 300 / 500 Sets ? Power : Dc12v / 1A ? Communication Interface : Usb ( A ) , Usb ( B ) , Wireless Bluetooth Module. 5 Touch Screen Analytical Balance Internal Calibration 0.1 Mg To 220 Gm :- Maximum : 220 Gm , Minimum : 0.1 Mg, Internal Calibration , Pan Size : 90 Mm , Repeatability : 0.1 Mg , Linearity : Plus Or Minus 0.2 Mg, Minimum Weight As Per Usp : 160 Mg, Response Time : 2 To 3 Seconds, Display : Alpha Numerical Lcd Backlite Display With A.E.P, Unit Of Measure : Gm , Mg , Ct , Gn , Mo , Oz , Dwt, Tare Range : Full Capacity , Operating Range : 10°C To 40°C, Protection : User Adminstration And Password Protection , Sensitivity Drift : Plus Or Minus 1 Ppm / °C In Temperature + 15 °C To35°C, Applicationmode:Pcs, %Weighing, Animal / Dynamic Weighing , Check Weighing . Automatic Density Determination, Formulation , Automatic Statistic Calculator Etc, Compliance :Iso, Glp, Gmp, Uspcompliance.Powersupply : A / C Adapter 230V Or 115V Plus Or Minus 20% 50 To 60 Hz, Net Weight : 8.0 Kg , Gross Weight : 9.3 Kg , Packing Size : 470 Mm Lenght X 310 Mm Width X 500 Mm Height , Packing Size :18.5 Inch Lenght X 12.2 Inch Width X 19.7 Inch Height 6 Hot Air Oven 22X22x36 Inch 300°C :- Size Dimension : 22 Inch X 22 Inch X 36 Inch • Rating Watts : 3500 • No Of Shelves : 4 • Hot Air Ovenare Sturdy Double Walled Units. •Inner Chambers Made Of Stainless Steel And Outer Made Of Mild Steel With Powder Coating . •Gap Between The Walls Fitted With Glass Wool Insulation To Avoid Heat Losses. •Heating Elements Are Made Of High Grade Chrome Plated Nichrome Wire. •Temperature Is Controlled By Thermostat. •Temp Range 50°C To 300°C And Accuracy Plus Or Minus 2°C ( With Digital Accuracy Plus Or Minus 1°C ) . •Air Ventilation Is Provided On The Top Of The Unit To Remove The Hot Gases / Fumes. In Lab Type Oven Heater Are Placed In The Bottom Side Of The Unit . •All The Control Switches And Pilotlamps Are Fitted On The Frontpanel.•Trays Shouldbe Supplied With Gi Wire Mesh With Digital Temperature Indicator Cum Controller And With Digital Timer . - This Oven Is Memmert Type. 7 Kjedhal Block Digester Along With Cooling Station And Fume Scrubber And Distillation Unit :- This Instrument Consist Of 3 Part = ( A ) Kjeldahl Block Digester With Cooling Station + ( B ) Fume Scrubber And ( C ) Automatic Kjeldahl Distillation Unit , And The Specification Of This 3 Parts Are Mentioned As Follows :- ( A ) Kjeldahl Block Digester With Cooling Station :- • Fast , Safe And Complete Digestion Of Samples Through Aluminiumblocks•Intricatelycontroldigestiontemperature Curves For Unsupervised Digestion. • Monitor Process Parameters & Pre-Set Samples Cycles. • Autolift Enables Complete Automation And Safety. • Cooling Stations Increase Throughput By Decreasing The Cooling Time Past Digestion. •Number Of Positions : 250 Ml X 12 Nos • Tube Capacity ( Ml ) : 250 Ml •Temperature Range : Ambient To 470°C • Timer Range : 1 To 300 Minutes • Temperature Precision : + Or - 1°C • Ramp And Hold : Upto 4 •Presets : Upto 50 • Auto Scrubber On / Off : Yes •Pid Control : Yes • Autolift : Yes • Auto Off After Achieving Set Time : Yes • Temperature Calibration : Yes , Single And Two Point • Pc & Printer Connectivity : Yes Upgradable • Display : Graphical Lcd • Body : Stainless Steel With Control Paneloffrp•Currentconsumption:8A•Dimension: 416X554x595mm • Power Consumption : 1600W • Cooling Station : Increase Sample Throughput By Saving Time On Sample Cooling • Save Time On Complete Kjeldhal Process As Cooling Station Offers Rapidsample Cooking. ( B ) Fume Scrubber:-• Transparentpc Protective Front Shield And Easy Removable Bottle Tray. • Carbon Adsorption Bottle Removal Any Trace Acid From Exhaust Air. • Fume Scrubber With 28Lpm Capacity For Complete Evacuation Of Acid Fumes. • Ptfe Air Baffle For Acid Neutralisation• 2 Litre Condensation And Neutralisation Jars For Larger Fume Volumes. • Polypropylene Head / Nozzle, Valve In Teflon & Diaphragm In Tefloncoatedneoprenerubber•Threadedtubeconnectorsfor Quick Removal Of Glass Components For Maintenance • Fume Condenser Attachment For Pre Condensation Of Excess Acid, Hence Saving Neutralisation Chemicals. • Current Consumption ( A ) :1A • Capacity :28Ltr / Min•Dimension ( Wxdxh ) Inmm : 365X375x480mm ( C ) Automatic Kjeldahl Distillation Unit : • Simple Programming And Stright Forward Operation • Quick Start Option With Favourite Method Menu • Start And Stop Cooling Water Automaticallly During The Distillation Process With Excellent Insulationofinternalparts•Robustacidresistanthousing• Compact Footprint Saves Useful Laboratory Bench Space • Brilliant Supervision Of All Crucial Functions • Comprehensive Built In Safety Systems For Operator Protection •Sample Analysis Reuires No Monitoring • The Inbuilt N / Protein Calculator With Extraction Of Results Makes The System Versatile Like Never Before • Automatic Dilution , Steam , Alkali , Acid And Test Tube Drain • Anti Corrosive Frp Body Construction • 7 Colored Touch Screen Display • Steam Regulation ( 10 To 100% ) • Process Kill Switch To Hall The Process In Caseofaccidential•Processresumefromstop•Detachable Bottom Drip Tray For Extra Protection Against Acid Attack • Anytime Alkali Addition During The Distillation Cycle • Tube Sensor That Enablessafeoperatingconditionsineventoftubedamage• Reagent Refill Level Sensor To Avert Reagent Dry Out • One Pointcalibrationofalkalianddistilledwaterpumps•Twopoint Calibrationforacidpumps•Realtimemonitoringofprocess Parameters • Selv Protection • Nitrogen Reproducibility : + Or -1% • Rsd < 1% • Lod Of 1 To 200 Mg With Greater Then Or Equalto0.1Mgof Nitrogen •Nitrogen Recovery Greater Then 99.5% •Tube Capacity ( Ml ) : 250 Ml , Minimum Distillation Time ( Mins ) : 5 , Current Consumption ( A ) : 10 , Power Consumption ( W ) : 1500, Dimension : Lenght 480 Mm X Breadth 470 Mm X 820 Mm 8 All Quartz Doubledistillation Unit 2.5 Ltr / Hr With Distillationapparatus Powersupply:- • Unit Consisit Of Primary Boiler With Built In Heater. Primary Boiler Has ‘O’ Ring Groove At The Top On Which A Silicone ‘O’ Ring Sits. The Primary Boiler Is Being Provided With ‘O’ Ring Which Acts As Cushion On Which Secondary Boiler And Condenser Unit Is Mounted. • The Secondry Boiler With Condenser Is Mounted On The Primary Boiler. • The Cooling Water Inlet And Outlet Are Both At The Top For Easy Maintenance • A Double Wall Condenser Ensuresseparate Condensation Of Vapor Coming From The Two Boilers Using Single Cooling Circuit. • An Additional Cooling Column Provides Larger Cooling Surface Area For Primary Boiler Avoiding Uncondensed Steam Escaping At The Top. • Daps ( Auto Cut Off System ) Has A Reset Button And A Buzzer. • We Provide 10 Mtrs Of 10Mm Id X 14Mm Silicon Tubing-- 10 Meters With Each Unit • The Bottom Outlet Is Connected To A ‘T’ Joint Of Which Limb Is Connected By Rubber Tubing & Pinch Cock For Cleaning Sediments In Primary Boiler By Acid Wash And Other Limb To The Water. •Dimension : Lenght : 35 Cm , Breadth : 35 Cm And Height : 100 Cm • Distillation Water Output Capacity : 2.5 Ltr / Hr . • Total Powerconsumed ( Kw ) : 4.4 • Condutivity ( S / Cm ) : 9 Automatic Titration Unit:- Volume Dosing: 0.001 To 999.999 Ml ? Volume Resolution: 0.001Ml To 1Μl ? Auto Fill And Dose During Titration Process ? Rsd Of 1% Or Less ? Dosing Resolution Is1 Μl ( 0.001 Ml ) In20, 000 Μl Or 1 / 20, 000 Resolution ? Special Feature Of “Burette Calibration And Correction” Of Dosed Volume. 10 Plant Sample Grinder / Mixture:-• Recommended For Grinding Of Samples • Polished ( Cast Mild Steel ) Chamber With Two Stationery Blades And Rotor With Four Cutting Edges • The Rotor Revolves At High Speed To Produce A Shearing Action Which Minimize Losses • Samples Introduced Through Hopper Are Agitated Until Cut To Sufficient Fineness To Fall Through The Sieve Delivery Tube Which Forms The Bottom Of The Chamber • Three Sieves 80 Mesh 1 Mm And 2 Mm Are Available.• Removable Glass Plate Forms The Face Of The Chamber And Permits Observation During Operations. • Removal Gives Access To The Interior For Cleaning • A Three Step V Belt Drive Permits Three Rotor Seeds By Changing The Pulley Position Of Belt • Complete With Hopper Wooden Plunger Three Sieves Of 80 Mesh 1 Mm & 2 Mm • Wrench For Adjusting Blades , Brush With 1 / 4-1H.P Continuous Duty Motor With V-Belt Drive, Switch, 3 Core Wire , Suitable For Operation On 230V , Single Phase, 50 Hz Ac Supply • Chamber Size :40X25mm • Motor Capacity : 0.25Hp 11 Magnetic Stirrer Along With Heater :- ? Mixes Volumes Up To 1.5L? Adjustable Speed Control From 100 To 1500 Rpm? Plate Dimensions: 8.5 X 8.5 Cm? External Dimensions L X W X H : 120 X 120 X 30 Mm? Weight : 0.2 Kg? Withstands Temperature Up To: 45 °C? Power : 2 W / 240 V / 50-60 Hz 12 Mechanical Shaker :- ? Intermittent & Continuous Shifting Motion? 20×4 Alphanumeric Lcd With Backlit Display? 2 Tier Password Protection? Fully Alphanumeric Keyboard ? Very Low Noise Operation? Up To 8 Sieves ( Test Sieve Dia 200Mm X 50Mm H ) 13 Centrifuge :- Max Speed Rpm 4400Max. Rcf ‘G’ 2350Max. Capacity Ml 200W X D X H Mm 330 X 370 X 295Supply: 220-240 Volts 50 Hz. Single Phase 14 Refrigerated Centrifuge:-Max. Speed 22, 000 Rpm Max. Rcf 55, 200 Xg ( R22a4 ) Max. Capacity 1, 500Ml X 4 Bottles ( R9a2 ) Speed Control Range 300 ~22, 000 Rpm Temperature Control Range Acl / Dcl Mode Acl: 9 Modes, Dcl: 9 Modes With Coasting Program Function 30 Programs, With Rcf ( G ) / G X Sec Function Drive Unit Induction Motor ( Inverter ) Refrigerator Closed Inverter Rotary ( Refrigerant : R410a ) 15 Fluorescence Microscope With Image Analyzer:-Standstable&Sturdy, Corrosionresistant.Anti-Fungalmould Treated, Singlemold Modular Stand Viewbody 300 Inclined Siedentopf Binocular / Trinocular Tubes, 3600 Rotatable With Ipd 53-75 Mm And Dioptric Adjustment Eyepiece Wf 10X / 22Mmwith Eye-Guards. Anti-Fungal Mould Treated Nosepiece Quadruple Reverse Angle Nosepiece Stage Double Layer Mechanical Stage 210Mm X 140Mm, Range Of Motion 75Mm X 50Mm. Integrated Mechanical Stage With Vernier, Low- Positioncoaxialcontrol Knobs Condenser N.A. 1.25 Abbe Condenser With Iris Diaphragm, Rack And Pinion Focusing Illumination / Reflectedfluorescence System3whighbrightnesswhiteled, Brightnessadjustable 3W Blue Led ( 460 / 470Nm ) , With Blue Fluorescentfilter System. Brightness Not Adjustable Power Input110-240V 50 / 60Hz Accessoriesorange Color Plastic Screen For Protection Against Uv Light, Powercode, Spare Fuses, Immersion Oil 16 Beaker:- 1. 1000 Ml -24, 2. 500 Ml -24, 3. 250 Ml -24, 4. 100 Ml -24 17 Volumetric Flask :- 1.1000 Ml -24, 2. 500 Ml -24, 3. 250 Ml -24, 4. 100 Ml -24, 5. 50 Ml -24, 6. 25 Ml -24 Conical Flask :- 1.250 Ml -24, 2.150Ml -24, Glass Rod:- 24 18 Boron ( Quarts Glass Wears ) Volumatic Flask:- 1.125 Ml -24, 2.250 Ml -24 19 Burrete ( 24 ) , Micro Pippate Electronic ( 10 ) , Manual Auto Pippate ( 10 ) , Measurening Cylinder ( 24 ) Etc. 20 Nitrogen :- 1. Boric Acid, 2. Sodium Hydroxide, 3. H2 So4, 4. Methyl Red Indicator, 5. Salicylic Acid, 6. Sodium Thiosulphate, 7. Copper Sulphate, 8. Selenium Powder, 9. Bromocresol Green, 10. Potassium Sulphate ( K2so4 ) 21 Phosphorus :- 1. Ammonium Molybdate, 2. Ammonium Vanadate, 3. Potassium Orthophosphate ( Kh2p04 ) Potassium :- 1. Potassium Chloride. 22 Ph :- Buffer Solution A. Ph-4.00 B. Ph-7.00 C. Ph-10.00 692 Ppm Nacl 23 Microcontinent :- 1. Standards For Calibration Fe, Cu, Zn, Mn 24 Sulphur :- 1. Barium Chloride, 2. Gum Acedia, 3. Magnesium Chloride ( Mgcl26h20 ) 4. Potassium Sulphate K2so4, 5. Potassium Nitrate, 6. Ethanol 7. Hydrochloric Acid 25 Boron :- 1. Ethenone Diamine Tetra Acetic Acid ( Disodium Salt ) , 2. Ascorbic Acid 3. Azomethine H, 4. Acetic Acid Glacial, 5. Calcium Oxidate, 6. Boric Acid ( H3b03 ) , 7. Ethyl Alcohol 26 Digestion :- 1. Nitic Acid ( Kn03 ) , 2. Perchloric Acid ( Helo4 ) , 3. Hydrogen Peroxide, 4. Hydrochloric Acid ( Hcl ) 27 Air Conditioner ( 1 To 1.5 Ton ) :- •Splitacwithinvertorcompressor•Capacitywith1.5Ton Suitable Formedium Size Room 125 To150 Sqft• Air Direction Control Auto With Brush Filter And Auto Clean • Rating 5 Star With Isi Mark 28 Computer With Monitor, Mouse And Keyboard And Software ( Auth. By Nic ) Printer :- • I5 • 8 Gb • 1 Tb Hdd • Integrated Uhd 730 Graphics • Wifi 6•Bluetooth 5.2 • Mineral Grey • 18.5 Monitor •Mouse •Keyboard • No Software Included With This Computer ( Software Like Windows 11 Not Included With This Computer , Only Hardware Will Be Supplied ) • All-In-Onemonochrome Printer Maximum Copy Width: 210 Mm Stack Copy: Up To 99 Pages, Or 1 Sided Print: Up To 34 Pages / Min ( A4 Size ) & Up To 36 Pages / Min ( Letter Size ) For 2 Sided Print: Up To 16 Pages / Min ( Up To 8 Sheets / Min ) ( A4 Size ) & Up To 17 Pages / Min ( Up To 8.5 Sheets / Min ) ( Letter Size ) Print, Scan & Copy Required 29 Chair, Stool, Trey, Cupboard :- 8 Chairs, 10 Stools, 10 Trey, 02 Cupboard, 06 Tables ( 2*8Ft ) 30 Laboratory Refrigerator :- Net Capacity ( Litres ) - 400 L 31 Cctv :- • 4 Ch E Series Dvr - 1 Quantity • 2.4 Mp Dome - 1 Quantity • 2.4 Mp Bullet - 1 Quantity • 1 Tb Toshiba Hdd Avdv - 1 Quantity • Power Supply - 1 Quantity • 3+1 Cctv Cable ( 1 Box 90 Meters ) • Bnc Dc Pins

Key Value

Document Fees
INR 1180 /-
EMD
INR 66320.0 /-
Tender Value
INR 66.32 Lakhs /-

BOQ Items

Name of Work: Supply of EssentialMachinery For Establishment of Plant Leaf & Tissue Analysis Laboratory
Sl. No. Item Description
1Atomic Absorption Spectrophotometer (AAS):-External PC-controlled new generation fully automated double beam optics Atomic Absorption Spectrometer fitted with fully automated 8-lamp turret with automatic alignment with strong deuterium background correction for analysis of Cu, Fe, Zn, Mn, As, Hg, Pb, and Mo. Lamp turret should have independent power supply to each lamp each with two heating circuit for lamp preheating operation. The turret must have comparability for lamps from other AAS manufacturers. The system should have both single & double beam optics with optional purge function for improved UV transmission. All optics should be quoted with proactive seal and double sealed with special light proof cover for enhanced stray light rejection and prevention of dust contamination. Monochromator: High energy Czerny Turner monochromator Wavelength range: 185-900 nm Grating: Holographic grating with 1800 lines/nm Slit Selection: Automated slit Selection with 0.2, 0.5, 0.8 and 1.2nm Focal Length: 389 mm Detector: Solid state Detector SiOSens, is most sensitive detector and is used in only high end equipment’s like (ICP OES.) wide range, linear read out 0.1 100%, low noise CSA, 5 V Background Correction: The system should have ultra-fast (300Hz) D2 background correction with superior S/N ratio and identical absorption profile of D2 and element lamp. Flame System: System should highest safety standard with coded burner heads, sensor control of flame, As type and pressure, pressure relief valve in the spray chamber, siphon sensor control & UV sensor for flame detection. Automated height adjustment of the burner head, Emission mode with baseline correction possibility. Gas control: Automatic control & optimization (flow/pressure) Safety measures: Gas Leak check, prevention of gas release System must have universal all Titanium 5 cm burner for both air/acetylene and acetylene/N2O flame.The system should have fully computer controlled total flow gas box with dual fuel and oxidant monitoring for stable control of fuel/oxidant ratio.Hg/Hydride-System. System should be offered with computer controlled dual pump Hg/Hydride-System for the determination of hydrideforming elements in µg/L range with electrically heated Cell Module (up to1000oC)asstandardconfiguration.Itshouldalsohave facilityforupgradationwithautomatedburnercleaningand micro volume injection. TheAASshouldhaveeasy,reproduciblechangebetween burner head and Cell Module with quick-lock. High specialized AAS software package with excellent and exhaustive and cook- book should be included. Software should have options for automatedoptimization of gas composition andburnerhead position for method development of unknown samples. The AAS should be supplied with 2 year warranty against all manufacturing defects. All local scope of supplies like PC & Printer, Hood, Gases, Regulators, Plumbing and Air compressor required for installation and operation of AAS to be mentioned and quoted separately. This instrument is supplied with Fume Hood.
2Double Beam Spectrophotometer Double Beam UV- VIS Spectrophotom eter with 10mm 8 (eight) place Cuvette cell Holder with spectral band width : variable 0.5 / 1 / 2 / 4 / 5 nm :- HighresolutionMonochromator,Seya-Namiokamount Wavelength Range: 190nm - 1100nm Spectral Bandwidth: Variable 0.5/1/2/4/5nm Cuvette Holder:10 mm8 (eight) place cuvette cell holder Wavelength Accuracy: +/- 0.1nm@656.1nm, +/-0.3nm@allWavelengthRepeatability:-<=0.1nmWavelength Accuracy:-: 0.2%T(0-100%T),+/- 0.002A(0-0.5A), +/-0.004A(0.5- 1A)Wavelength Setting:-AutoPhotometric repeatability::+/- 0.15%T(0- 100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) Stray light :-: <=0.03% T@220nm, 360 nm Photometric Range:-: 0-200%T.- 0.3-3A,0-9999C(0-9999F)StrayLight:+/-0.0003A/h@500nm Wavelength Scan Speed: Auto Response: Fast, Medium, Slow Baseline Stability: 0.001 A Noise Level: 0.0005A@500nm Work Mode: -T,A,C,E Baseline flatness: 0.0001A Detector : Imported Silicon Photodiode Display: 10.1” TFT Colored High quality
3Flame Photometer with PC Link Software and with compressor:- • Micro controller based automation for ease operation •Determination up to four elements with single aspiration (Na,K,Li & Ca) • Curve Fitting correction for non linear emisiion characteristics of elements at higher concentration , maximum five point calibration • Storing Facility for setups and results (date wise & batch wise , maximum 700 results ) the same can be recalled whenever need arise . • 4 line 20 character LCD readout • Facility for restandardization with single standard • Built in real time clock for date and time analysis • Printout facility for individual sample , batch sample , total days samples or entire results in the memory (700 max ) • Air compressor with built in air regulator and air Filter • Pc link Software for transferring data to computer and manipulation of data in computer using RS-232. • Reproducibility : : low conc : plus or minus 1% fs , High conc : plus or minus 2% Fs. • Minimum Smaple : 3ml / element (Approx) • Averaging Time : 2 to 15 seconds • Operating Air Pressure : 0.45 kg/cm square • Air Compressor : With Built in air regulator and air filter to deliver stable and moisture oil free supply with pressure of 1 kg/cm sqaure. • Printer Port : Epson compatible 80 column DM printer • RS-232 Port : PC Link data Transfer • Memory : Storage 700 results • Power : 230V plus or minus 10% , 50 Hz • Dimensions : 415 (W) x 255 (D) X 305 (H) mm (Main Unit) , 255 (W) x 210 (D) x 205(H) mm ( Compressor ) • Weight : Main Unit 6.5 Kg + Compressor 6 Kg • This instrument is supplied with PC Link SOftware. This instrument is supplied with 4 filters that is Na,K,Li & Ca
4PH Meter 5 point calibration :- Display capacitive touch screen with resolution 1024*600 pH ? Measurement Range :- ( -2.000 - 19.999) pH ? Resolution :- 0.01/0.001pH ? Accuracy :- +/- 0.01pH ? Input Current :- < 1x10- 12 A ? Input Impedance :- > 1x10 ? Stability :- +/- 0.01 pH/3h ? Temperature Compensation :- ( 0-100) C (Auto or Manual) mV ? Measurement Range(mv/ORP/EH) :- -1999.9mV~0~1999.9mV ? Resolution :- 0.1mV ? Accuracy :- +/- 0.03%% FS Temperature ? Range :- -10c ~ 110C ? Resolution :- 0.1C ? Accuracy :- +/- 0.5 C Calibration Automatic (1,2,3points),NISTStandards Others ? Data Storage : 300/500 sets ? Power : DC12V/1A ? Communication Interface : USB(A),USB(B), Wireless Bluetooth Module.
5Touch Screen Analytical Balance internal calibration 0.1 mg to 220 gm :- Maximum : 220 gm , Minimum : 0.1 mg, Internal Calibration , Pan Size : 90 mm , Repeatability : 0.1 mg , Linearity : plus or minus 0.2 mg, Minimum weight as per USP : 160 mg, Response time : 2 to 3 seconds, Display : Alpha Numerical LCD Backlite display with A.E.P, Unit of measure : gm , mg , ct , GN , mo , oz , dwt,Tare range : Full Capacity , Operating range : 10°C to 40°C, Protection : User adminstration and Password Protection , Sensitivity drift : plus or minus 1 ppm / °C in temperature + 15 °C to35°C,Applicationmode:PCS,%weighing,Animal/ Dynamic Weighing , Check weighing . Automatic density Determination, Formulation , Automatic statistic Calculator etc, Compliance :ISO,GLP,GMP,USPCompliance.Powersupply : A/C Adapter 230V or 115V plus or minus 20% 50 to 60 Hz, Net Weight : 8.0 Kg , Gross Weight : 9.3 Kg , Packing Size : 470 mm lenght x 310 mm width x 500 mm Height , packing Size :18.5 inch lenght x 12.2 inch width x 19.7 inch Height
6Hot Air Oven 22x22x36 inch 300°C :- Size Dimension : 22 inch x 22 inch x 36 inch • Rating Watts : 3500 • No of shelves : 4 • Hot Air Ovenare sturdy double walled Units. •Inner Chambers Made of Stainless Steel and Outer Made of Mild Steel with Powder Coating . •Gap Between the walls fitted with Glass wool Insulation to avoid heat losses. •Heating Elements are made of High Grade Chrome plated nichrome Wire. •Temperature is controlled by Thermostat. •Temp Range 50°C to 300°C and Accuracy plus or minus 2°C (with Digital accuracy plus or minus 1°C). •Air Ventilation is provided on the top of the Unit to Remove the Hot Gases/Fumes. In Lab Type Oven Heater are placed in the bottom side of the Unit . •All the control Switches and Pilotlamps are fitted on the FrontPanel.•Trays shouldbe supplied with GI Wire mesh with Digital Temperature indicator cum controller and with Digital Timer . - This oven is Memmert Type.
7Kjedhal Block Digester along with Cooling Station and Fume Scrubber and Distillation Unit :- This instrument consist of 3 part = (A) Kjeldahl Block Digester with cooling station + (B) Fume Scrubber and (C) Automatic Kjeldahl Distillation Unit , and the specification of this 3 parts are mentioned as follows :- (A)Kjeldahl Block Digester with cooling station :- • Fast , Safe and Complete digestion of samples through aluminiumblocks•Intricatelycontroldigestiontemperature curves for unsupervised digestion. • Monitor process parameters & pre-set samples cycles. • Autolift enables complete automation and safety. • Cooling stations increase throughput by decreasing the cooling time past digestion. •Number of Positions : 250 ml x 12 nos • Tube Capacity (ml) : 250 ml •Temperature range : Ambient to 470°C • Timer range : 1 to 300 minutes • Temperature precision : + or - 1°C • Ramp and Hold : upto 4 •Presets : upto 50 • Auto scrubber ON/OFF : Yes •PID control : Yes • Autolift : Yes • Auto OFF after achieving set time : yes • Temperature calibration : Yes , single and two point • PC & Printer connectivity : Yes Upgradable • Display : Graphical LCD • Body : stainless steel with control panelofFRP•Currentconsumption:8A•DImension: 416x554x595mm • power consumption : 1600W • Cooling Station : Increase sample throughput by saving time on sample cooling • Save time on complete Kjeldhal process as cooling station offers rapidsample cooking.(B)Fume Scrubber:-• TransparentPC Protective front shield and easy removable bottle tray. • Carbon adsorption bottle removal any trace acid from exhaust air. • Fume scrubber with 28LPM capacity for complete evacuation of acid fumes. • PTFE air baffle for acid neutralisation• 2 litre condensation and neutralisation jars for larger fume volumes. • Polypropylene head/nozzle,valve in TEFLON & Diaphragm in tefloncoatedneoprenerubber•Threadedtubeconnectorsfor quick removal of glass components for maintenance • Fume condenser attachment for pre condensation of excess acid, hence saving neutralisation chemicals. • Current Consumption (A) :1A • Capacity :28Ltr/Min•Dimension(WXDXH)inmm : 365x375x480mm (C) Automatic Kjeldahl Distillation Unit : • Simple programming and stright forward operation • Quick start option with favourite method menu • Start and stop cooling water automaticallly during the distillation process with excellent insulationofinternalparts•Robustacidresistanthousing• compact footprint saves useful laboratory bench space • Brilliant supervision of all crucial functions • comprehensive built in safety systems for operator protection •sample analysis reuires no monitoring • The inbuilt N/protein calculator with extraction of results makes the system versatile like never before • Automatic dilution , steam , alkali ,acid and test tube drain • Anti corrosive FRP body construction • 7" colored touch screen display • steam regulation (10 to 100%) • Process kill switch to hall the process in caseofaccidential•Processresumefromstop•Detachable bottom drip tray for extra protection against acid attack • Anytime alkali addition during the distillation cycle • Tube sensor that enablessafeoperatingconditionsineventoftubedamage• Reagent refill level sensor to avert reagent dry out • one point calibrationofalkalianddistilledwaterpumps•twopoint calibrationforacidpumps•Realtimemonitoringofprocess parameters • SELV protection • Nitrogen reproducibility : + or -1% • RSD < 1% • LOD of 1 to 200 mg with greater then or equal to0.1mgof Nitrogen •nitrogen recovery greater then 99.5% •Tube capacity (ml) : 250 ml , Minimum distillation time (mins) : 5 , Current consumption (A) : 10 , Power consumption (W) : 1500, Dimension : Lenght 480 mm x Breadth 470 mm x 820 mm
8All Quartz DoubleDistillation Unit 2.5 Ltr/hr with DistillationApparatus powersupply:- • Unit Consisit of Primary boiler with built in heater. Primary Boiler has ‘O’ Ring groove at the top on which a Silicone ‘O’ Ring sits. The primary Boiler is being provided with ‘O’ Ring which acts as cushion on which Secondary Boiler and Condenser Unit is mounted. • The Secondry Boiler with Condenser is Mounted on the primary Boiler. • The cooling water inlet and outlet are both at the top for easy maintenance • A Double wall Condenser ensures separate condensation of vapor coming from the two Boilers using single cooling circuit. • An Additional Cooling Column provides larger cooling surface area for primary Boiler avoiding uncondensed steam escaping at the top. • DAPS ( Auto cut off system ) has a Reset button and a buzzer. • We provide 10 mtrs of 10mm id x 14mm Silicon tubing-- 10 meters with each unit • The bottom outlet is connected to a ‘T’ joint of which limb is connected by rubber tubing & pinch cock for cleaning sediments in Primary Boiler by acid wash and other limb to the water. •Dimension : Lenght : 35 cm , Breadth : 35 cm and Height : 100 cm • Distillation water output capacity : 2.5 Ltr/hr . • Total Powerconsumed (kw) : 4.4 • Condutivity (S/cm) :
9Automatic Titration Unit:- Volume dosing: 0.001 to 999.999 ml ? Volume resolution: 0.001ml to 1µl ? Auto Fill and Dose during titration process ? RSD of 1% or less ? Dosing resolution is1 µl (0.001 ml) in20,000 µl OR 1/20,000 Resolution ? Special feature of “Burette Calibration and Correction” of dosed volume.
10Plant Sample Grinder/Mixture:-• Recommended for Grinding of samples • Polished (cast mild steel) chamber with two stationery blades and rotor with four cutting edges • The rotor revolves at high speed to produce a shearing action which minimize losses • Samples introduced through hopper are agitated until cut to sufficient fineness to fall through the sieve delivery tube which forms the bottom of the chamber • Three sieves 80 mesh 1 mm and 2 mm are available.• Removable glass plate forms the face of the chamber and permits observation during operations. • Removal gives access to the interior for cleaning • A three step v belt drive permits three rotor seeds by changing the pulley position of belt • Complete with hopper wooden plunger three sieves of 80 mesh 1 mm & 2 mm • wrench for adjusting blades , brush with 1/4-1H.P continuous duty motor with v-belt drive,switch,3 core wire , suitable for operation on 230V , single phase, 50 Hz AC supply • Chamber size : 40x25mm • Motor Capacity : 0.25HP
11Magnetic stirrer along with heater :- ? Mixes volumes up to 1.5L ? Adjustable speed control from 100 to 1500 rpm ? Plate dimensions: 8.5 x 8.5 cm ? External dimensions L x W x H : 120 x 120 x 30 mm ? Weight : 0.2 kg ? Withstands temperature up to: 45 °C ? Power : 2 W / 240 V / 50-60 Hz
12Mechanical Shaker :- ? Intermittent & Continuous Shifting Motion ? 20×4 Alphanumeric LCD with Backlit Display ? 2 Tier Password Protection ? Fully Alphanumeric Keyboard ? Very Low Noise Operation ? Up to 8 Sieves (Test sieve Dia 200mm x 50mm h)
13Centrifuge :- Max Speed rpm 4400 Max. RCF ‘g’ 2350 Max. Capacity ml 200 W x D x H mm 330 x 370 x 295 Supply: 220-240 Volts 50 Hz. Single Phase
14Refrigerated Centrifuge:-Max. Speed 22,000 rpm Max. RCF 55,200 xg(R22A4) Max. Capacity 1,500ml x 4 bottles (R9A2) Speed Control Range 300 ~ 22,000 rpm Temperature Control Range ACL/DCL Mode ACL: 9 modes, DCL: 9 modes with coasting Program Function 30 programs, with RCF(g) / g x sec function Drive Unit Induction Motor (Inverter) Refrigerator Closed Inverter Rotary (Refrigerant : R410A)
15Fluorescence Microscope with Image analyzer:-StandStable&Sturdy,corrosionresistant.Anti-fungalmould treated, singlemold modular stand ViewBody 300 Inclined Siedentopf Binocular/Trinocular tubes, 3600 rotatable with IPD 53-75 mm and dioptric adjustment Eyepiece WF 10x/22mmwith Eye-guards. Anti-fungal mould treated Nosepiece Quadruple Reverse angle nosepiece Stage Double layer mechanical stage 210mm x 140mm, range of motion 75mm x 50mm. Integrated mechanical stage with vernier, low- positioncoaxialcontrol knobs Condenser N.A. 1.25 Abbe condenser with Iris diaphragm, rack and pinion focusing Illumination / ReflectedFluorescence System3WhighbrightnesswhiteLED,brightnessadjustable 3W blue Led (460/470nm), with blue fluorescentfilter system. Brightness not adjustable Power Input110-240V 50/60Hz AccessoriesOrange color plastic screen for protection against UV light, Powercode, Spare fuses, Immersion Oil
16Beaker:- 1. 1000 ml -24,2. 500 ml -24, 3. 250 ml -24, 4. 100 ml -24
17Volumetric Flask :- 1.1000 ml -24, 2. 500 ml -24, 3. 250 ml -24, 4. 100 ml -24, 5. 50 ml -24, 6. 25 ml -24 Conical Flask :- 1.250 ml -24, 2.150ml -24, Glass Rod:- 24
18Boron (quarts Glass wears) Volumatic Flask:- 1.125 ml -24, 2.250 ml -24
19Burrete (24), Micro Pippate electronic (10), Manual Auto Pippate (10), Measurening Cylinder (24) Etc.
20Nitrogen :- 1. Boric Acid, 2. Sodium Hydroxide, 3. H2 So4, 4. Methyl red Indicator, 5. Salicylic Acid, 6. Sodium Thiosulphate, 7. Copper Sulphate, 8. Selenium Powder, 9. Bromocresol Green, 10. Potassium Sulphate (k2so4)
21Phosphorus :- 1. Ammonium Molybdate, 2. Ammonium Vanadate, 3. Potassium Orthophosphate (Kh2P04) Potassium :- 1. Potassium Chloride.
22PH :- Buffer Solution a. PH-4.00 b. PH-7.00 c. PH-10.00 692 PPM NACL
23Microcontinent :- 1. Standards for Calibration Fe, Cu, Zn, Mn
24Sulphur :- 1. Barium Chloride, 2. Gum Acedia, 3. Magnesium Chloride (mgcl26H20) 4. Potassium Sulphate K2So4, 5. Potassium Nitrate, 6. Ethanol 7. Hydrochloric Acid
25Boron :- 1. Ethenone Diamine Tetra Acetic Acid (Disodium Salt), 2. Ascorbic Acid 3. Azomethine H, 4. Acetic Acid Glacial, 5. Calcium Oxidate, 6. Boric Acid (H3B03), 7. Ethyl Alcohol
26Digestion :- 1. Nitic Acid (Kn03), 2. Perchloric Acid (Helo4), 3. Hydrogen Peroxide, 4. Hydrochloric Acid (hcl)
27Air Conditioner (1 to 1.5 Ton) :- •SplitACwithinvertorcompressor•Capacitywith1.5ton suitable formedium size room 125 to150 sqft• Air direction control auto with brush filter and auto clean • Rating 5 star with ISI Mark
28Computer with Monitor, Mouse and Keyboard and Software (Auth. By Nic) Printer :- • i5 • 8 GB • 1 TB HDD • Integrated UHD 730 Graphics • Wifi 6•Bluetooth 5.2 • Mineral grey • 18.5" Monitor •Mouse •Keyboard • No software included with this computer (Software like Windows 11 not included with this computer , only hardware will be supplied) • All-in-oneMonochrome Printer Maximum Copy Width: 210 mm Stack Copy: Up To 99 Pages, or 1 Sided Print: Up to 34 pages/min (A4 size) & Up to 36 pages/min (Letter size) For 2 Sided Print: Up to 16 pages/min (Up to 8 sheets/min) (A4 size) & Up to 17 pages/min(Up to 8.5 sheets/min) (Letter size) Print, Scan & Copy Required
29Chair, Stool, Trey, Cupboard :- 8 Chairs, 10 Stools, 10 Trey, 02 Cupboard, 06 tables (2*8ft)
30Laboratory Refrigerator :- Net Capacity (Litres)- 400 L
31CCTV :- • 4 ch E series DVR - 1 quantity • 2.4 MP Dome - 1 quantity • 2.4 MP Bullet - 1 quantity • 1 TB Toshiba HDD AVDV - 1 quantity • Power supply - 1 quantity • 3+1 CCTV cable (1 box 90 meters) • BNC DC pins