}

Tender For Comprehensive Maint Of Air Conditioner Plant Split And Window Type Air Conditioner And Repair Maint To Summer Appliances, Desert Cooler, Deep Freezer, Refrigerator And Allied Services Under Ge (W) Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Comprehensive Maint Of Air Conditioner Plant Split And Window Type Air Conditioner And Repair Maint To Summer Appliances, Desert Cooler, Deep Freezer, Refrigerator And Allied Services Under Ge (W) Pathankot. Submission Date for this Tender is 11-03-2023. Air Conditioner Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36205805
Corrigendum : Tender For Comprehensive Maint Of Air Conditioner Plant Split And Window Type Air Conditioner And Repair Maint To Summer Appliances, Desert Cooler, Deep Freezer, Refrigerator And Allied Services Under Ge (W) Pathankot
Open Tender
Indian
Punjab
pathankot
11-03-2023

Tender Details

Comprehensive Maint Of Air Conditioner Plant Split And Window Type Air Conditioner And Repair Maint To Summer Appliances, Desert Cooler, Deep Freezer, Refrigerator And Allied Services Under Ge ( W ) Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Feb-2023 Amendment to BOQ and Tender documents BOQ 04-03-2023
2 04-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

BOQ Items

NAME OF WORK : COMPREHENSIVE MAINT OF AIR CONDITIONER PLANT/ SPLIT AND WINDOW TYPE AIR CONDITIONER ANDREPAIR/ MAINT TO SUMMER APPLIANCES, DESERT COOLER, DEEP FREEZER, REFRIGERATOR AND ALLIED SERVICES UNDER GE (W) PATHANKOT
Sl. No. Item Description
1Servicing of water /air type cooling tower / condensor complete by changing its acrilic fins inside the bottle and pipes, nozzeles etc including cleaning and spray painting with synthetic enamelled paint complete all as specified and directed by Engr- in -charge.
2S&F in replacement of existing UNSVWater pressure gauge 0-7 Kg of 15mm diaall as specified and directed by Engr- in -charge.
3S&F in replacement of existing UNSV Water temperature thermometer of dia 15 mmall as specified and directed by Engr- in -charge.
4Repair and maintenance of Central AC plantof capacity 2X50 TONton atKiran Auditorium including supply and fixing in replacment of following parts including testing complete:- a)S&F of air filter As per existing size-(6Nos) b)V-belt B-83- 02No c)Tyer Coupling TC93(2 (Nos) d)Servicing of electric motors(4 Nos) e)Cleaning the AHU -(2 Nos) f) S&F of air filter As per existing size- (6Nos
5M&L for replacement of old unsv compressor oil (servo) for AC plant complete all as specified and directed by Engr- in -charge.
6M&L for descaling of condensor of 50 TR capacity of AC Plant with dilute chemical solutionand with the help of nylon brush 3-4 times followed by the cleaning and washingwith water so that chemical solution is completely clean out from system complete all as specified and directed by Engr- in -charge.
7S&F Oil seal assembly for 50 ton compressor ofmake voltas model T-5000 completeall as specified and directed by Engr- in -charge.
8M&L for rewinding of AHU motor of 15 HP three phase with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, varnishing change the bearing of size,unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
9M&L for rewinding of Condensor/Chiller Pump motor of 7. 5 HP three phase with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, varnishing change the bearing of size,unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
10Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 4 KVA after disconnecting the voltage stabilizer from machine, rewinding transformer with super enamelled copper wire of existing gauge, Voltmeter, Amps Meter, PCB circutcomplete all as specified and directed by Engr- in -charge.
11Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 5 KVA after disconnecting the voltage stabilizer from machine, rewinding transformer with super enamelled copper wire of existing gauge complete all as specified and directed by Engr- in -charge.
12S& F in replacement of existing UNSVvoltmeter -600 volt ac complete all as specified and directed by Engr- in -charge.
13S& F in replacement of existing UNSV Amp meter 0-200 amps ac complete all as specified and directed by Engr- in -charge.
14S& F in replacement of existing UNSVAmp meter 0-100 amps ac complete all as specified and directed by Engr- in -charge.
15S& F in replacement of existing UNSV Amp meter 0-60 amps ac complete all as specified and directed by Engr- in -charge.
16S& F in replacement of existing UNSVAmp meter 0-50 amps ac complete all as specified and directed by Engr- in -charge.
17S& F in replacement of existing UNSV Power Contactor ML-2 coil voltage 240 Volt all as specified anddirected by Engr- in -charge.
18S& F in replacement of existing UNSV Contactor ML-1 coil voltage 240 Volt all as specified anddirected by Engr- in -charge.
19S&F in replacement of UNSV MCCB 100 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on load all as specified and directed by Engr- in -charge.
20S&F in replacement of UNSV MCCB 200 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on load all as specified anddirected by Engr- in -charge.
21Taking down defective AC, windowtype of capacity upto 2 ton of any make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge.
22S&F Starting relay for window AC, split AC fixed in repair all as specified and directed by Engr- in -charge.
23S&F Thermostate switch for window AC,hot and cold type fixed in repairall as specified and directed by Engr- in -charge.
24S&F Swing motor for window type AC / split type AC of capacity 1.5 ton as per existing make LG/Voltas/ whirlpool fixed in repair complete all as specified and directed by Engr- in -charge.
25S&F Running capacitor 50 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repairall as specified and directed by Engr- in -charge.
26S&F Running capacitor 60 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repairall as specified and directed by Engr- in -charge.
27S&F Running capacitor 45 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repairall as specified and directed by Engr- in -charge.
28S&F Running capacitor 36 +2, to 6 MFD (ISI Marked) for window AC 1.5/2 Ton fixed in repairall as specified and directed by Engr- in -charge.
29S&F Front grill of window AC, capacity 1.5/2 ton suitable for Make:- LG/ Carrier/ Sidwal/ Whirlpoolas per existingfixed in repair complete all as specified and directed by Engr- in -charge. Make;- LG/ carrier
30S&F Condensing fan of window type AC ofcapacity 1.5 ton as per existingfixed in repair complete all as specified and directed by Engr-in-charge. MAKE -LG/VOLTAS/CARRIER
31S&F Blower fan of window type AC ofcapacity 1.5 ton as per existingfixed in repair complete all as specified and directed by Engr- in -charge.
32S&F Sheet metal enclosurewithMCB single pole 20 Amp for AC fixed in repair complete all as specified and directed by Engr- in -charge.
33Servicing of window type AC/ split type AC ofcapacity 1.5 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motorcomplete all as specified anddirected by Engr- in -charge.
34S&F Blower Motor (ISI marked) 1/5 HP capacityof window type AC fixed in repair complete all as specified anddirected by Engr-in-charge.
35S&F in replacement of UNSV Recycle valve kit to maintain the desired temperatureof cooling system of window type AC /split type A 1.5/2 tonC as perrequirement includinggas charging, fixed in repair complete all as specified and directed by Engr- in -charge.
36S&F in replacement of UNSV PCB circuit Hot & cold for window type AC as per existing make complete all as specified and directed by Engr- in -charge.
37S&F in replacement ofunsv condensingcoil for window type AC of capcity 1.5 ton includinggas charging, complete all as specified and directed by Engr- in -charge.
38S&F Copper pipe of dia 1/4 inchfixed in repair complete all as specified and directed by Engr- in -charge.
39S&F Copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed by Engr- in -charge.
40S&F Copper pipe of dia 1/2 inch fixed in repair complete all as specified and directed by Engr- in -charge.
41Taking down defectivesplit type ACofany capacity /make after disconnecting electric connections and transporting to workshop from site ,dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same withnew compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge.
42Taking down defectivesplit type ACofany capacity /make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from INVERTER ACand replacing the same withnew compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge
43Taking down defective indoor Unitfor Split AC 1.5 / 2Ton and replacing the same withnew for existing make of AC complete all as specified and directed by Engr- in -charge.
44S&F in replacement ofPCB circuithot and cold to split type AC 1.5 /2 ton for existing makes of AC complete all as specified and directed by Engr- in -charge.
45S&F in replacement of PCB circuitfor INVERTER AC hot and cold to split type AC for existing makes of ACcomplete all as specified and directed by Engr- in -charge.
46S&F Blower Motor (ISI marked ) of split type ACfixed in repair complete all as specified anddirected by Engr- in-charge.
47S&F Condensor fan Motor (ISI marked ) of split type ACfixed in repair complete all as specified anddirected by Engr-in-charge.
48S&F in replacement of UNSV Remote control with two AAA battery for split type AC ofcapacity 1.5 ton/2 tonsuitable for make of LG/ Carrier/ Sidwal/ Whirlpoolas per existing complete all as specified and directed by Engr-in-charge.
49S&F Insulation material for copper pipe outer covering 25mm thick fixed in repair complete all as specified and directed by Engr-in-charge.
50S&F in replacement condensing fanforsplit type ACof capacity 1.5ton /2 ton complete all as specified and directed by Engr-in-charge.
51S&F in replacement Blower fanforsplit type ACof capacity 1.5ton /2 ton complete all as specified and directed by Engr-in-charge.
52S&FPVC flexible copper conductor sheathed cableof size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed by Engr-in-charge.
53Supply & Charging RefrigerantR-134 complete one time for topup or making full qty as per pressure requirment of plant and testing for any leakage and rectifying the sameall as specified anddirected by Engr- in -charge.
54Supply & charging Refrigerant R 22 to Aiir conditioner (window type /split type) of any capacity and make all as specified anddirected by Engr- in -charge.
55Supply & charging Refrigerant R 32 to Aiir conditioner (window type /split type) of any capacity and make all as specified anddirected by Engr- in -charge
56Supply & Charging Refrigerant R-410 to Air conditioner (window type /split type )of any capacity and make complete all as specified anddirected by Engr- in -charge.
57Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 0.5 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable partslike voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparingthe surface complete all as specified and directed by Engr- in -charge
58Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 1 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable partslike voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparingthe surface complete all as specified and directed by Engr- in -charge
59Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 2 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable partslike voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparingthe surface complete all as specified and directed by Engr- in -charge.
60Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 3 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable partslike voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparingthe surface complete all as specified and directed by Engr- in -charge.
61S&F in replacementUNSV Submersible water lifting pump for desert cooler ,230 V ,50 Hz fixed in repair include taking down old one complete all as specified and directed by Engr- in -charge. Make : Khaitan/ Cool Home/Orison.
62S&F in replacement of UNSV Fan motor of desert cooler 1/7 HP with fan blade & legs single phase230 V, 50 Hzcomplete all as specified and directed by Engr- in -charge. Make : Khaitan/ Cool Home/ AUE
63M&L for rewinding of D/cooler fan motor of 1/7 HP single phase 3 speed with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
64S&F in replacement Rubber pipe 15mm dia (ISI marked) heavy grade for desert cooler fixed in repaircomplete all as specified and directed by Engr- in -charge.
65S&F in replacement Wood wool padof size 24" x 18" (set of 3) for desert cooler fixed in repair complete all as specified and directed by Engr- in -charge.
66S&F in replacement Water distributorfor water connection of desert cooler complete all as specified and directed by Engr- in -charge.
67S&F in replacement in replacement selactor switch for desert cooler for three speed motor ISI Marked all as specified and directed by Engr- in -charge.
68S&F in replacement GI front show grill complete with selector switch, piano type switch and indicator etc. as per requirement fixed in repair complete all as specified and directed by Engr- in -charge.
69S&F in replacement Plug top three pin 15 Amps complete all as specified and directed by Engr-in-charge.
70S&F in replacement Plug top three pin 5 Amps complete all as specified and directed by Engr- in -charge. .
71S&F in replacement Ball valveofsize 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe fixed in repair complete all as specified and directed by Engr- in -charge.
72S&F in replacement PVC connection of size 15mm x 450 mmsuperier quality fixed in repair complete all as specified and directed by Engr- in -charge.
73S&F in replacement Stop valve of PTMT of size 15mm, any colourscrewed for iron pipe (ISI marked)fixed in repair complete all as specified and directed by Engr- in -charge.
74Removing of desert cooler coolers from site after disconnecting the electric connection and water connectiontaking out rusted bottom and replacing with new bottom as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed.by Engr- in -charge
75S&F in replacement Side shutter of Desert cooler as per existing size with 24 gauge PGI sheet of desert coolercomplete all as specified and directed.
76Removing of desert cooler coolers from site after disconnecting the electric connection and water connectiontaking out rusted Side legs and replacing with new legs as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed by Engr- in -charge..
77S&F in replacement Capacitor 4 MFD (ISI Marked) fixed in repair all as specified and directed by Engr- in -charge.
78Supply & Charging Refrigerant R 134 a/R-32 to Refrigeratorsof any capaciy, & replace old drier and capillary tybe as per existing size any lengthand make all as specified anddirected by Engr- in -charge. .
79S&F in replacement Starting relay for water cooler No CAJ -2612 / CAJ -34 /AHR 13 all as specified anddirected by Engr- in -charge.
80S&F in replacement Starting capacitorof capacity 60-80 MFD, 80 / 100,100/120 MFD (ISI Marked) for water cooler fixed in repair all as specified anddirected by Engr- in -charge.
81S&F in replacement Over load protectorof any size for water cooler fixed in repairall as specified anddirected by Engr- in -charge.
82S&F in replacement Thermostat switch of any size for water cooler fixed in repair all as specified anddirected by Engr- in -charge.
83S&F in replacement new Condensing fan blade (As per sample) for water cooler ofany sizefixed in repair all as specified and directed by Engr- in -charge..
84S&F in replacement Self closing bib cockchromium plated for water cooler of any size fixed in repair all as specified and directed by Engr-in-charge.
85S&F in replacement Rubber gasket coverof size 1cmx1cm for top cover of water coolerall as specified and directed by Engr- in -charge
86S&F Rubber pipe1.25 inch diafor water waste of water coolerall as specified and directed by Engr- in -charge..
87Removing of water cooler of model No CAJ-2612 from site after disconnectingelectric & water connections and transporting to workshop, taking out burnt compressorand replacing with new compressor suitable for refrigerentgas R134a of the same make/ company of existing water coolerwith 12 months warranty including leakage test, gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr- in -charge. Make - COPELAND/ VOLTAS / SHRI RAM
88Removing of water cooler of modelNo CAJ-34 from site after disconnectingelectric & water connections and transporting to workshop,taking out burnt compressorand replacing with new compressor suitable for refrigerentgas R134a of the same make/ company of existing water coolerwith 12 months warranty including leakage test, gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr-in-charge..Make - COPELAND/ VOLTAS / SHRI RAM
89Removing of water cooler of modelNo AHR-13 from site after disconnectingelectric & water connections and transporting to workshop ,taking out burnt compressorand replacing with new compressor suitable for refrigerentgas R134a of the same make/ company ofexisting water coolerwith 12 months warranty including leakage test, gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed. at site completeall as specified and directed.Engr- in -charge..Make - COPELAND/ VOLTAS / SHRI RAM
90S&F in replacement Blower motor of capacity1/35 HP for water cooler of capacity40/80, 60/120 Ltrs fixed in repair all as specified and directed by Engr- in -charge
91S&F in replacement Blower motor of capacity1/10 HP for water cooler of capacity150 Ltrs fixed in repair all as specified and directed by Engr- in -charge.
92S & Charging Refrigerant R 134 a / R22 /R-32 to Water Cooler of any capaciy, & replace old drier and capillary tybe as per existing size any lengthand make all as specified anddirected by Engr- in -charge. .
93Removal of rusted bottom and repair of body of water cooler of any make and capacity with MS sheet 0.71mm thick, pedestal legs and fixing bottom sheetof suitable existing size and pedstal legs,frame ofwater cooler by angle iron of size 25x25x3mmand welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge..
94Removal of rusted bottom and repair of body of refrigerator of any make andof capacity 165/ 300 ltrs with MS sheet , pedestal legs and fixing bottom sheet of suitable existing size and pedestal legs, frame of refrigerator with angle iron and welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge.
95Removingrefrigerator of capacity 280/300ltrsfrom site after disconnectingelectricconnection and transporting to workshop,taking out burnt compressorand replacing with new compressor 1/6 HP Suiteble comperessor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr- in -charge. Make - LG/ VOLTAS / GODREJ
96Removingrefrigerator of capacity 165/190liters from site after disconnectingelectricconnection and transporting to workshop ,taking out burnt compressorand replacing with new compressor1/8 hp R134a compitablecomperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr-in-charge. Make - LG/ VOLTAS / GODREJ
97Removingrefrigerator of capacity 320ltrsdoubble door from site after disconnectingelectricconnection and transporting to workshop,taking out burnt compressorand replacing with new compressor R134a compitablecomperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr- in -charge. Make - LG/ VOLTAS / GODREJ
98S&F in replacement fan motor with fan for Double door Refrigerator all as specified and directed byEngr- in -charge. Make -Whirlpool/ LG per suitable size.
99S&F in replacement PCB Circuitfor Double door Refrigerator all as specified and directed byEngr- in -charge.Make -Whirlpool/ LG / samsung per suitable size.
100S&F in replacement Bio Metalfor Double door Refrigerator all as specified and directed byEngr- in -charge. Make -Whirlpool / LG / samsung per suitable size.
101S&F in replacement heaterfor Double door Refrigerator all as specified and directed byEngr- in -charge. Make -Whirlpool/ LG suitable size.
102S&F Thermostat switchfor refrigerator fixed in repair all as specified anddirected by Engr-in-charge.
103S&F in replacement Starting relay of refrigarator of any capacity fixed in repair all asspecified and directed Engr- in -charge
104S&F Over load protector of refrigarator of any capacity fixed in repairall asspecified and directed by Engr- in -charge.
105S&F Freezer door of refrigerator of any capacityfixed in repair all asspecified and directed by Engr- in -charge
106S&F in replacement defective cooling coil from refrigerator and supply and fixingnew cooling coil as per existing size and make with gas refilling all as specified and directed by Engr- in -charge.
107S&F in replacement defective condensing coil from refrigerator and supply and fixingnew condensing coil as per existing size and make with gas refilling all as specified and directed by Engr- in -charge.
108S&F in replacement PVC flexible copper conductor sheathed cableof size 1.5 Sqmm 3 core, fixed in repair complete all as specified and directed by Engr- in -charge.
109S&F Thermostate switch for deep freezersof any capacity fixed in repair all asspecified and directed by Engr- in -charge.
110RemovingDeep Freezer of capacity 200/300 ltrsfrom site after disconnectingelectricconnection and transporting to workshop ,taking out burnt compressorand replacing with R134 a compitablecomperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging,testing including transporting back from workshop and installing at site completeall as specified and directed by Engr- in -charge.
111S&F in replacement defectivecondensing coil from deep freezer and supply and fix new condensing coilwith gas charging of R 134aall as specified and directed by Engr- in -charge Make of cooler :- voltas/ blue star/ usha
112S&F in replacement Condensor fan motor fordeep freezer of any capacity fixed in repair as per exiting size & makeall asspecified and directed Engr- in -charge .Make of deep freezer: voltas /blue star
113S&F in replacement vegitable tray for Refrigerator as per suitable size all as specified and directed byEngr- in -charge..
114S&F in replacement bulb for Refrigerator as per suitable size all as specified and directed byEngr- in -charge..
115S&F in replacement Racks Jali for Refrigerator as per suitable size all as specified and directed byEngr- in -charge..
116S&F in replacement bottle support for Refrigerator as per suitable size all as specified and directed byEngr- in -charge.
117Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 79,934.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the acceptedcontract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail