Military Engineer Services-MES has published Special Repair To Ber Summer And Electrical Appliances At Af Stn Under Ge ( Af ) Bamrauli. Submission Date for this Tender is 03-03-2023. Electrical Maintenance Tenders in bamrauli Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Feb-2023 | Corrigendum No 1 | BOQ | 03-03-2023 |
Sl. No. | Item Description |
1 | Supply, install,fixing and commissioning split type air conditioner of capacity 1.5 TR,five star rated withinvertor type cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed. Note :- (i) Quoted rates deem to be included cost ofdrain pipe, copper tubing and 2.5 sqmm multi standard copper cable (all 3 mtr length) , backet,wall mounted AC Stand, hole in brick wall etc. (ii)Installation and commissioning to be done through OEM / itsauthorised service centre / dealer. |
2 | Supply, install,fixing and commissioning split type air conditioner of capacity 2.0 TR,five star rated invertorwith cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed. Note :- (i) Quoted rates deem to be included cost ofdrain pipe, copper tubing and 2.5 sqmm multi standard copper cable (all 3 mtr length) , backet, wall mounted AC Stand,hole in brick wall etc. (ii)Installation and commissioning to be done through OEM / itsauthorised service centre / dealer. |
3 | M&L for laying of copper tubing of dia5/8” including insulation and brazing work complete all as specified anddirected by Engineer –in-Charge |
4 | M&L for laying of copper tubing of dia3/8” including insulation and brazing work complete all as specified anddirected by Engineer –in-Charge |
5 | S&F PVCinsulated stranded 4 core flexible copper cable of size 2.5sqmm 1100 volt grade complete all as specified anddirected by Engineer –in-Charge |
6 | Supply, fixing and commissioning refrigerator electric driven 230V AC 50 AC 50 Hz capacity 310 Ltrs or nearest higher capacity frost free, double doorstar rated andnecessary connections complete. |
7 | Supply installation, commissioning of Deep freezer hard top suitable for operation on 240 volts 50Hz AC supply of capacity 320 Ltrs (or nearest higher size) double basket type withstar rated with suitable refrigerant complete all as specified and as directed |
8 | Supply, installation, testing and commissioning desert cooler overall minimum size 650mm x 650mm x 910mm, electric driven, 230 volts, single phase, 50 HZ supply having nominal air flow capacity of 4000 cubic metre per hour or nearest standard size shall be placed on existing platform /standincluding provision of PVC braided connection heavy duty 750mm long with brass union at both ends for necessary water connection complete. Desert cooler comprising of following : - 1. Nominal air delivery : Min 4000 Cum/hr.2. Mounting:Floor standing without wheels.3. Filter pads: Wood wool pads( Non-corrosive wire guard for filter Pads shall be provided). 4. Float valve at inlet : 15 mm dia PVC with plastic ball and aluminimumrod. 5. Sump tank capacity : 80 liters for 4000 nominal capacity. 6. Sheet thickness and material of filter panel, grill, top of coller body and cabinet :Minimum 1.00 mm thick PGI sheet(zinc coating not less than 100 gms / sq mtr)and Sump tank - Minimum 1.25 mm thick PGI sheet(zinc coating not less than 100 gms / sq mtr). 7.All internal surfaces of cooler shall be painted with Water resistant paint to IS 9862 (latest revision)8. Fan size: 18 inch for 4000 nominal capacity. .9. Fan motor:Khaitan(Model A-080 ,Power:1/7 HP, 3 speed,Voltage : 230V, 50Hz , Speed: 1360 RPM ,Class B insulation )with standard clamps for fixing to body of cooler.or equivalent make of CG/Usha. 10.Three metreminimum length of ISI marked connecting cable with 3-pin moulded plug top, 5/6 Amps with on /off switch shall be provided. 11. Submersible pump: Make:Khaitan (Model:AQUA80) 40 watt (minimum) capacity, 220/240 volts, single phase, 50Hz having lifting height 3 metre of or Crompton/Vansal/Bajaj . 12. Spray painting to external surfaces of cooler and anticrosive rubber paint to internal surface of water tank portion.12.Stop valve and PVCwater connection pipe shall be deemed to included in rate quoted by contractor |
9 | Dismantling and taking down and depositing to MES Store yard of old unserviceable split type AC/Water Cooler/deset cooler any capacity |
10 | Supply and fixing ceiling fansRobust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5star rating for energy saving,AC single phase 230/240 V of size 1200 mm sweepincluding making connection with three core flexible, copper cable pvc insulated of suitable length incl taking down old & deposited to MES store yardcomplete all as spd & directed. Note : Cost of remote cell included in this item |
11 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe suitable size with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltrs having element 1.5/2 KW BEE star rating incl taking down old and deposted to MES store yard |
12 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified as directed. |
13 | Removing excavated soil n.exc 50m and depositing where directed at a level n.exc1.5m above the starting point etc complete all as specified as directed. |
14 | M&L forPCC 1:4:8 type D-2 (40mm graded aggregate) Cement concrete in foundations filling and mass concrete etc complete all as specified as directed. |
15 | M&L for Pre- painted galvalume aluminum zinc coating GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all specifiedas directed. |
16 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe-410- W(GdeE-250) quality-B etc complete all as specified and directed. |
17 | M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete. |
18 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed |
19 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed |
20 | S&F elevation tiles in vertical surfaces 300x450x10mm/300x600x10mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match rendering 10 mm thick in CM 1:4 on vertical surface as in backing coat all as specified and directed. |
21 | M&L for complete removing of existing treatment on wall surface and applyingtwo coat of OBD including a coat of birla white care Putty on wallobtain smooth finish etc completeall as specified and directed. |
22 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail