| 1 | Renavation of Hospital Kitchen |
| 2 | 15.28.1Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet |
| 3 | 15.17.1Dismantling steel work in single sections including dismembering and stacking within 50 metes leadin:R.S. Joists |
| 4 | 15.3Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposalof unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 5 | 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 6 | 15.7.4Demolishing brick work manually / by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 7 | 15.12.1Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below |
| 8 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 9 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete |
| 10 | 4.1.6Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 11 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size |
| 12 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 13 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good qualityblasted rubble including packing to compactness to lines and levels cost and conveyance of all materialslabour charges etc. complete as per direction of Departmental officers at site |
| 14 | od13484/2022_2023Filling with departmental earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 15 | 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest availablesize confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 16 | 50.6.1.7Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 17 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantilevers |
| 18 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,Abutments, Posts and Struts |
| 19 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform |
| 20 | 13.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 21 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labourcharges etc complete |
| 22 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specifiedby the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm,including pointing in white cement mixed with pigment of matchingshade complete. |
| 23 | 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement primer |
| 24 | 13.83.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile includingapplying additional coats wherever required to achieve even shade and colour.Two coats |
| 25 | 13.47.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:Newwork (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20kg/ 10 sqm) |
| 26 | 9.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows bywelding |
| 27 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two ormore coats on new work |
| 28 | od27094/2022_2023Re-fixing departmental doors, windows and clerestory windows (steel wood or aluminium sliding window )shutter including chowkhats, architrave, holdfasts etc.all complete |
| 29 | od28551/2022_2023Providing and laying vitrified rustic floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, inall colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), includinggrouting the joints with white cement and matching pigments etc., complete. Size of Tile 400 x 400mm.(9mm or nearest size thickness) |
| 30 | 10.2Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, includingcutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 32 | 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation asapproved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum toavoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm)with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 33 | od27444/2022_2023Providing and fixing Deparmental profile sheets.to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required. |
| 34 | od25223/2022_2023Supplying and fixing best quality PVC square type gutter 200 mm or nearest size with GI clamps at1.00m spacing including cost and conveyance of materials and labour charges etc.. |
| 35 | 17.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets andstainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x 1040 mm bowl depth 225 mm |
| 36 | 17.28.1.1Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semirigid pipe32 mm dia |
| 37 | 50.18.7.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |