| 1 | M&L for monthly \"A\" Check Inspection, maintenance and serviceing DG sets, 125 KVA Capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House, including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintanance as required at site and directed by Engr-in Charge. Note: Items/ Spares required shall be measured and paid separately under respective item of BOQ (i) Checking engine oil level and topping up as and when required. (ii) Checking and adjusting the belt for tension and replacement of belt if required. (iii) Checking of oil bath air cleaner level(iv) Checking of exhaust system for leakage(v) Draining of sediment from fuel filter and fuel tank(vi)Cleaning of air cleaner elements(vii) Checking engine alternator coupling, mounting bolts and alignment(viii) Tighting all nuts, bolts, in altenator terminal block(ix) Checking of alternator carbon brushes and connections in alternator(x)Checking and tightening of all connection in DC control wiring.(xi)Checking of all radiator rubber hoses for leakage and replacement if required. (xii)Checking and recording oil pressure, water and oil temperarute for smooth functioning.(xiii)Checking anti vibration mounting pads for any deformation.(xiv)Checking throttle linkage for smooth operation.(xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level(xvi)Routine check / repair work of panel, switches, MCCBs, main switch, all contactors, engine control unit etc.(xvii)Checking of AMF panel, all electrical connections etc.(xviii) Checking of earthing resistance(xix)Cleaning of vegitation around the DG set up to 1.5 mtr area. |
| 2 | All as per serial item No 1 but DG set 100 KVA capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house |
| 3 | All as per serial item No 1 but DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house |
| 4 | All as per serial item No 1 but DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house |
| 5 | All as per serial item No 1 but DG set 200 KVA capacity, Make : Kirloskar, ModalKG 254M-1 Location :DAD complex |
| 6 | All as per serial item No 1 but DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house |
| 7 | All as per serial item No 1 but DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhingar pump house |
| 8 | M&L for \"B\" Check once in Six month OR 250 Hrs running whichever is earlier for DG sets of 125 KVA Capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House,Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintenance as per OEM instructions and as directed by Engr-in-Charge.Note: Items/ Spares including \"B\" Check kit, coolent, lubricating oilrequired shall be measured and paid separately under respective item of BoQ. (i)Repeat the activities of \"Á\" Check services(ii)Replacment of lubricant oil. (iii)Replacing lubricant oil filters element with O rings(iv)Replacing fuel filters element with O rings(v)Replacing air filter elements with O rings(vi)Replacing coolant. |
| 9 | All as per serial item No 8 but for DG set 100 KVA capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house |
| 10 | All as per serial item No 8 but for DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house |
| 11 | All as per serial item No 8 but for DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house |
| 12 | All as per serial item No 8 but for DG set 200 KVA capacity, Make : Kirloskar, ModalKG 254M-1 Location :DAD complex |
| 13 | All as per serial item No 8 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house |
| 14 | All as per serial item No 8 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house |
| 15 | Supply only \"B\" check kit for DG set 125 KVA capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House. Note : Quoted rate includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters and air filters inner and outer as recommended by OEM |
| 16 | All as per serial item No 15 but for DG set 100 KVA capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house |
| 17 | All as per serial item No 15but for DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house |
| 18 | All as per serial item No 15 but for DG set 160 KVA capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house |
| 19 | All as per serial item No 15 but for DG set 200 KVA capacity, Make : Kirloskar, ModalKG 254M-1 Location :DAD complex |
| 20 | All as per serial item No 15 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house |
| 21 | All as per serial item No 15 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house |
| 22 | Supply & Refiling coolent, K cool super plus 50-50 premix all as specified and as directed. |
| 23 | Supply & Refiling battery water with electrolyte mix all as specified and as directed. |
| 24 | Supply & Refiling engine oil 20 W 40 turbo synthetic superior quality engine oil all as specified and as directed. |
| 25 | S&F radiator hose pipe set with clamps suitable for DG set of capacity 100 /125 KVA all as specified and as directed. |
| 26 | S&F radiator hose pipe set with clamps suitable for DG set of capacity 160/200 KVAall as specified and as directed. |
| 27 | S&F radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA all as specified and as directed. |
| 28 | S&F fan belt set suitable for 100/125 KVA all as specified and as directed. |
| 29 | S&F fan belt set suitable for 160/200 KVA all as specified and as directed. |
| 30 | S&F fan belt set suitable for 320 KVA all as specified and as directed. |
| 31 | S&F in replacement of battery lead with negative & positive brass terminals of suitable size and length of each lead all as specified and as directed. |
| 32 | Servicing & repair to self starter of DG set of 100 KVA to 320 KVAincludingreplacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc. assembling and testing complete all as directed by Engr-in-Charge. |
| 33 | S&F in replacement of battery 12 V, 180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete as directed by Engr-in-Charge. Make: Excide/ Amara Raja/ Luminous |
| 34 | M&L in replacement of indicator lamp 230 V AC supply of AMF panel all as specified and as directed. |
| 35 | S&F in repairs cam shaft assembly for Greaves make DG set 320kVA all as specified and as directed. |
| 36 | S&F in repairs cam shaft bushings set for Greaves make DG set 320kVA all as specified and as directed. |
| 37 | M&L in replacement cam shaft assembly of 320 KVA including dismentalling of concerned subassemblies, lifting arrangments, packings & O rings for head, top cover, copper washers & O rings for push rod complete work all as specified and as directed. |
| 38 | S&F in repairs oil pump assembly for 320KVA Greaves DG set with replacement of chamber packing & O rings all as specified and as directed. |
| 39 | M&L in repairs broken conopy door hinges of DG set ofany capacity and make. Setting of conopy door, properly locking arrengement complete all as specified and as directed. |
| 40 | S&F in replacement of fuel level gauge of DG set as per existing make, model complete all as specified and as directed. |
| 41 | M&L for dismantling, transportation to workshop and back, opening, rewinding main winding assembly and refixing 100 to 320 KVA DG set alternater, three phase, 415 V, 50 Hz with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint includingrepair/replacement of diode plates for neutral & phase and repair / replacement of AVR, connecting, testing and commissioningat site for satisfactorily operation as required and directed by Engr-in-Charge. |
| 42 | S&F in replacement of alternator connection terminal block suitable for 100 to 320 KVA DG Set alternetor as per existing sample complete all as specified and as directed. |
| 43 | M&L in replacement of battery stand frame of size 4 feet x 1.5 feet with height of 1 feet made of 50mm x 50mm x 6mm angle iron and support with flat iron of size 40mm x 6mm, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, 20 mm wooden plank on top to place 02 Nos batteries complete all as specified and as directed. |
| 44 | Supply installing testing & commissioning in replacement AMF Control panel boardCPRI type tested suitable for 200 KVA DG set, outdoor type with angle iron pedestal frame, cubical type, free standing, floor mounted, working on 415V 3 phase 50 Hz AC complete with color coated copper bus 300 Amps fully compartmentalised, dust proof and vermin proof outdoor type 3.15 mm thick CRCA sheet enclosure complete including painting as per 7 tank process and suitable for IP 52 protections as per specifications includingtaking down existing AMF control panel board and providing necessary arrangement at engine side for the satisfactory functioning of AMF panel, provision of wiring system from DG set to AMF panel and Circuit diagram plate and comprising the followings all as specified and as directed:- Incomer:AMF control circuit with MCCB 4 pole with overload current rating of 300 Amps with beaking capacity at 415 V AC 50 Hz of 36KA with thermal magnetic release setting complete with all standard accessoies all as specified and directed - 02 Nos ( one for main supply and one for DG set supply) 4 pole changeover contractors AC 3 heavy duty with HRC backup fuse complete with all DC control relays / line voltage monitor (LVM) Outgoing :-(i) MCCB 4 pole with over load current rating of 300 amps and ultimate breaking capacity at 415V 50 HZ of 36 kA with thermal magnetic release setting complete with all standard accessories all as specified and directed -01 No(a)Panel Mounted battery charger - 01 No(b)Toggle switches for mannual and auto operation(c)Digital type voltmeter for DG supply & main supply 0-500V with selector switch -02 Nos(d)Alarm / Hooter - 01 No(e)Digital Type ammeter 0-400Amps with cast resin type CT\"s & selector switch -02 No(f)Start/Stop push buttons(g)Digital Type frequency meter for 50Hz AC supply - 01No(h)Analogue type Power factor meter - 01 No(i) LED indicators (R, Y, B) |
| 45 | Dismaintling, radiator assembly from the engine of 200KVA DG set Make KIRLOSKARModel 6 SL 9088T by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back including necessary welding brazing as required , refixing , reconnecting and testing for proper functioning all as specified and as directed. |
| 46 | All as per serial item No 45 but for 160 KVA DG set Make : KIRLOSKARModel 6 SL 1500TA. |
| 47 | All as per serial item No 45 but for 125 KVA DG set Make KIRLOSKAR Model 6 SL 9088T. |
| 48 | All as per serial item No 45 but for 100 KVA DG set Make KIRLOSKAR Model 6 SL 9088T/Model no. KG100W52. |
| 49 | S&F in repairs, fuel level indicator pipe white transparent including two jublee clamps, marking level with radiem paint/ tape complete all as specified and as directed. |
| 50 | S&F in repairs, exhaust pipewhite asbestos rope including removing old unservicable ropeall as specified and as directed. |
| 51 | S&F in repairs,MCCB, 3 Pole,400 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugsall as specified and as directed. |
| 52 | S&F in repairs,MCCB, 3 Pole 250 Amps, capacity 50 Hz, 415 volts with rating 36KA and connection with proper lugsall as specified and as directed. |
| 53 | S&F in repairs,MCCB, 3 Pole 200 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugsall as specified and as directed. |
| 54 | S&F in repairs,MCCB, 3 Pole 160 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugsall as specified and as directed. |
| 55 | S&F in repairs, automatic voltage regulator Kitsuitable for 100/125 KVAalternator including incomingand out going cable connection and tesring on completion all as specified and as directed |
| 56 | M&L for Bearing grease HP/BP type servo Gem Natra-3/Lithon-3. in 5 kg pack all as specified and as directed |
| 57 | S&F in repairs, flexible love-joy coupling set with Nut/ Bolt and rubber bushes suitable for existing DG set including metal fillinggrinding, finishing to suit the siteinstallation alinging for noise free function all as specified and as directed |
| 58 | S&F in repairs, rubber bushing/rubber spider of DG set coupling complete with Nut , bolt and washer all as per site requirement and as directed by Engineer - in - charge . |
| 59 | M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panelall as specified and as directed |
| 60 | Supply and topping up / replacement of insulating oil of stabilizer chamber with new insulating / transformer oil upto the required level in any type and capacity of the voltage stabilizer all as directed by Engineer-in-Charge.Note : Insulating / transforemer oil brought by the contractor at site must be in seal packed in drum having ISI mark as per IS-335 / 1983.Make : Savita / Asian. |
| 61 | Repair / Servicing to voltage stabilizers 3 phase 4 wire system, 160 to 300 KVA by at siteby opening carefully from top,taking out coils / connections, cleanig coils checking defective joints / soldering / jointing, re- assembling and testing on full load and making fully servicable including spray painting with supper enamelled paint of colour as directed by EIC, complete all as specified and directed. |
| 62 | S&F in repairs, off load change over switch - Disconnectors in sheet metal enclosure, 400Amps, 4P, 415 V all as specified and as directed |
| 63 | M&L for 4 sqmm, 2 core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old unserviceable cable all as specified and as directed. |
| 64 | All as per serial item No 63 but 10 sqmm, 2 core |
| 65 | M&L for repair and replacment of unserviceable time switch accessories/ spares including reconnecting and testing complete all as specified and as directed.Note : - Spares/accessories required for replacement shall be measured and paidseperatly under respective items of BoQ. |
| 66 | S&f in repairs, time switch analog type, single phase, 230 Volts of rating 20 Amps all as specified and as directed. |
| 67 | S&F in repairs, contactor, 40 amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugsall as specified and as directed. |
| 68 | S&F in repairs, contactor, 63 amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugsall as specified and as directed. |
| 69 | S&F in repairs,MCB TPN 16-32 Amps, 415 Volts, 50 Hz, \"C\" series, AC supply systemall as specified and as directed. |
| 70 | S&F in repairs, MCB TPN 40-100 Amps, 415 Volts, 50 Hz\"C\" series, AC supply systemall as specified and as directed. |
| 71 | M&L for 70 sqmm, single core, 1100 volts grade, heavy duty cable, PVC insulated, copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed including taking down old unserviceable cable and protection covers all as specified and as directed. |
| 72 | M&L for three core, 4 sqmm, 1100 volts, PVC Insulated & PVC sheated Industrialflat copper cable for submersible pump motors including water proof jointincluding taking down old unserviceable cable all as specifiedand as directed. Make- Havells Cat no.WHPNDSKG34X0 or equivalent from list of makes. |
| 73 | S&F in repairs, LED solar street light fitting, 40 watt including galvanised steel pole 100mm bore dia 5m long, embedded in and includingPCC 1:2:4, type B2 concrete, in built,lithium ion battery 24 AH 12.8V,solar panel 100 W ,charge controller with disk down sensor, excavation and earthwork completeall as specified and as directed. Make of LED solar street light fitting: Luker Cat Part No : LSTPSOLO40 or equivalent model of make Philips / GE/ Crompton/ Havells/Century LED/ Halonix/ SYSKA. |
| 74 | M&L in repairs/replacement of battery charger, 24 V DC SMPS 10 Amp for AMF panelall as specified and as directed. |
| 75 | S&F in repairs water pump assembly for Kirloskar make DG set Model 6SL all as specified and as directed. |
| 76 | S&F in repairs turbocharger repair kit for KirloskarDG set model -6SL all as specified and as directed. |
| 77 | M&L for preparation of exposed surfaces of DG set upto 200kVA capacity and spray painting with synthetic enamel paint of approved shade all as specified and as directed. |
| 78 | Repair to FIP of 320 KVA capacity DG Set by taking out carefully and re-fixing after calibration at authorised service centre / dealer including replacement of unserviceable worn out parts such as Tacho shaft, Gasket, O rings, Main Shaft, Element, Delivery valves, washer, nuts & bolts, control springs etc. all as specified and as directed. |
| 79 | S&F in repairs of 24 V starter assembly suitable for 200 kVA DG set all as specified and as directed. |
| 80 | Excavation in trenches n, exc,1.5 m wide and n, exc,1.5 m in depth for laying of cable, foundation of pole/stayand getting out in soft/loose soil complete all as specified and as directed. |
| 81 | Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers n,exc.25cm thick all as specified and as directed. |
| 82 | Removing excavated soil to distance n, exc 50 m and depositing where directed at a level n,exc.1.5 m above the starting point complete all as specified and as directed. |
| 83 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 120 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioning including taking out existing cable alongwith protection covers complete allasspecified and as directed. |
| 84 | All as per serial item No 83 but cable of size 95 sq mm, 3.5 core. |
| 85 | All as per serial item No 83 but cable of size 70 sq mm, 3.5 core. |
| 86 | All as per serial item No 83 but cable of size 50 sq mm, 3.5 core. |
| 87 | All as per serial item No 83 but cable of size 25 sq mm, 3.5 core. |
| 88 | All as per serial item No 83 but cable of size 16 sq mm, 4 core. |
| 89 | All as per serial item No 83 but cable of size 16 sq mm, 2 core. |
| 90 | All as per serial item No 83 but cable of size 10 sq mm, 2 core. |
| 91 | M&L in repairs for straight through cable jointing kit, heat shrinkablefor 1.1 KV grade,25 to 50 sqmm 3.5 coreXLPE cable with jointing material and accessories and testing after jointing all as specified and as directed. |
| 92 | All as per serial item No 91 but for 70 to 120 sqmm, 3.5 core XLPE cable |
| 93 | Supply and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/sq. cm, 50 mm bore with fusion, laid in trenches including jointing and testing complete all as specified and as directed. |
| 94 | Supply and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/sq. cm, 100/110 mm bore with fusion,laid in trenches including jointing and testing complete all as specified and directed. |
| 95 | S&F in repairs, 50 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed. |
| 96 | S&F in repairs, 80 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed. |
| 97 | S&F in repairs, LED flood light fitting, 200 watt, 230 V, AC, outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. |
| 98 | S&F in repairs, LED flood light fitting, 120 watt, 230V, AC, outdoor typewith thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lampall as specified and as directed. |
| 99 | S&F in repairs, LED flood light fitting, 70 watt, 230V, AC, outdoor typewith thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lampall as specified and as directed. |
| 100 | S&F in repairs, LED street light fitting, 100 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and asdirected. |
| 101 | S&F in repairs, LED street light fitting, 35Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and asdirected. |
| 102 | S&F in repairs, LED street light fitting, 60 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and asdirected. |
| 103 | S&F in repairs, LED post top lantern, 20 watt, 230 Volt, AC with decorative post top 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete all as specified and as directed. |
| 104 | S&F in repairs, automatic street light switch, using infra-red sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural light Lux*level. Required llluminance Level for switching ON is <_60Lux and for Switching OFF>_10Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs , The Sensor along with suitable Power Contactor(s) and Incoming-outgoing MCBs and Auto -manual (sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made ofRust Proof, Electric Shock Proof, Termite proof and FR grade SMC junction box/ Enclosure conformig to IP 54 with suitable steel clamps,nuts, bolts for installation on pole complete as directed. The circuit should be suitable enough to take single phase load of 5 - 8 KW (swadeep-02EC-5KW1P) with contactor ,incoming MCBs,outgoing MCBs rating of 40-63 Amps and main load circuit wiring (copper cable) of min 10 sqmm all as specified and as directed.Make :- (a) Nature switch : Kakatiya Energy Systems/Bajaj/Healer, (b) Contractor : L&T, conform to IEC -60947-4-1 /IS-13947-4-1(c) MCB : L& T, conform to IEC-60898 /IS-8828 (d) Enclosure & Circuit Sheet : Sintex or Equivalent as approved from list of makes specified in tender documents, (e) Circuit wiring: Polycab/Finolex |
| 105 | S&F in repairs, 4 pole MCCB, 630 amps, 50 KA, 415 Volts, with adjustable type settings all as specified and as directed. |
| 106 | All as per serial item No 105 but MCCB 250 Amps, 36 KA |
| 107 | All as per serialitem No 105 but MCCB 200 Amps, 36 KA |
| 108 | All as per serial item No 105 but MCCB 160 Amps, 36 KA |
| 109 | All as per serial item No 105 but MCCB 125 Amps, 25 KA |
| 110 | All as per serialitem No 105 but MCCB 25 to 100 Amps, 25 KA |
| 111 | S&F in repairs/replacement of steel tubular swaged pole complete with mild steel box plate, 6 mm thick of size 300 x 300 mm, finial taper plug, pole cap, bolts,nuts, washers & screws as specified, type410- SP-31 (9 m long), made outof ERW mild steel tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc erected in true vertical position including painting the pole with two coats of aluminium paint over a coat of red oxide primer on exposed pole surfaces and two coats of black bituminoius paint for portion embedded in concrete including painting three black/red/ bands at lower portion of pole of 1.8 m height at 300 mm spacing, painting pole No with black paint at suitable height including demolition of foundation concrete and coping complete all as specified and as directed. |
| 112 | M&L for PCC 1:4:8, type D2, using 40 mm graded stone aggregates as in foundation of pole/stays all as specified and as directed. |
| 113 | M&L for PCC 1:3:6, type C1, using 20 mm graded stone aggregates as in coping of pole and similar work etc including necessary formwork and finishing even and smooth without using extra cement complete all as specified and as directed. |
| 114 | M&L for cutting/drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and directed at site. |
| 115 | S&F cross arms, bracings, support channel, back plate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint including dismantling existing cross arms, MS Channel or anglesectioncomplete all as specified and as directed. |
| 116 | S&F pin type porcelain vitreous brown/white insulator with approved make including one galvanised MS spindle two GI Washers and GI nut of size 100 mm height and 65 mm dia 1100 Volt grade including taking out old unserviceable insulator complete all as directed |
| 117 | All as per serial item 116 but size 150mm dia , 150 mm height for 11000 Volts grade. |
| 118 | S&F shackle type, porcelain, vitreous, brown/white insulator of size 75 mm height, 90mm dia with approved make including galvanised MS strip of section 31 mm x 3 mm,insulated bolts 12mm dia, washers, nut etc for working pressure 1100 volt grade, including taking out of old unserviceable insulator complete all as directed. |
| 119 | S&F single disk assemblyinsulator, porcelain, vitreous, 145mm high and 225 mm dia, and socket typewhite, brown or green with all acessoriesincluding taking out of old unserviceable insulator complete all as directed. |
| 120 | S&F in repairs, Male contact / Moving contact Blade all as specified and as directed.Make :Jaipuria Brs / Pactil / Atlas |
| 121 | Unbinding of the ACSR conductor from insulator on pole, pruning tree branches3 mtr all arround conductor andrestringing ACSR conductor of 2 to 6 conductors, tightening ofOH Lines, binding to the insulators using required size of aluminium binding wire complete all as directed by Engr-in-charge . |
| 122 | Labour andfault detector machine required for locating fault in undergroundcable, 11 KV by using fault detector machine including transportation and by carring out high pressure test all as directed by Engr-in-charge. |
| 123 | Labour andfault detector machine required for locating fault in undergroundLT cable, 1100 volts by using fault detector machine including transportation and by carring out high pressure test all as directed by Engr-in-charge. |
| 124 | Trimming/cutting oftree branches 3 mtr adjacent to the LT OH lines/street light feeder on both sides as per the direction of AGE E/M/JE incharge including removing the tree branches from site complete all as specified and directed.Note : (i)Written shut down shall be obtained from concerned JE/AGE (E/M) before taking the trimming work in hand by contractor.(ii)Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (iii) Any damage caused due to negligence of workmen will be rectified without any extra payment (iv)T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor. |
| 125 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to GI earth wire 4 mm dia , by means of nut bolts, check nuts and washer, GI earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 126 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI or steel earth strip 32 mm x 6 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 40mm dia GI protection pipe, light grade,including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 127 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI or steel earth strip 25 mm x 4 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 32mm dia GI protection pipe, light grade,including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 128 | M&L in repairs, air termination, single pointed aluminium rod, 12 mm dia and 300 mm long, mounted on 40 mm dia pipe of length 0.5 meter including grouting of pipe all as specified & asdirected |
| 129 | M&L in repairs, test point terminal block, made of gun metal or phosphorus bronze, size 75mm x 75mm x 25 mm, drilled and screwed, including 3 Nos. 8 mm dia, 25 mm long hexagonal head screw all as specified & as directed. |
| 130 | M&L in repairs, 32mm x 6 mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in counduit /pipe or fixed to poles or any other indicated situation for loop earthing all as specified and as directed. |
| 131 | All as per serial item No 130 but25mmx 3.15mm aluminium strip |
| 132 | M&L for aluminium conductor steel reinforced (ACSR), any size, (Weasel/Ferret/Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag complete including dismantling ACSR conductor from LT/HT pole all as specified and as directed. |
| 133 | Repair & Replacing Digital Voltmeter square type complete including necessary fixing, fixed in replacement complete all as specified and as directed. |
| 134 | Repair & Replacing Digital Ammeter square type complete including necessary fixing, fixed in replacement complete all as specified and as directed. |
| 135 | S&F in replacement Phase indicator lamps complete all as specified and as directed.(set of R Y B) |
| 136 | Dismanthing/taking down carefully the defective street light/security light/ floodlight fittings/ Post top lanterns of any description and servicing/ cleaning, checking connections, replacement of unserviceable spares, reassembling and refixingat its original location including reconnections and testing / commisssioning complete all as directed. Note: (i) Spares to be replaced shall be measured separately under relevant items of schedule.(ii)Cost of minor parts like screws, nut bolts, washers, pieces of wires and insulation tape etc required on site is deemed to be included in the quoted rates. |
| 137 | S&F in repairs, LED drivers for 18 Wto 30 W LED panel lights/Post top /batten fittings any type and any make as per sample, all as specified and as directed. |
| 138 | S&F in repairs, LED Drivers for 34 W to 48 WLED panel lights any type and any make as perall as specified and as directed. |
| 139 | S&F in repairs,LED Drivers for 30 W to 50 WLED Security lightfittings any type and any make as per sample,all as specified and as directed. |
| 140 | S&F in repairs, LED Drivers for 60 Wto 90 W LED Security lightfittings any type and any make as perall as specified and as directed. |
| 141 | S&F in repairs,LED Drivers for 70 W to 200 WLED Flood light fittings any type and any make as per sample,all as specified and as directed. |
| 142 | S&F in repairs,LED surge protectors for exisiting Size/CapacityLED fittings any type and any make as per sample,all as specified and as directed. |
| 143 | S&F in repairs,brackets made out of 40mm bore GI pipe, light grade, 1.5M long, bend to shape and including suitable MS clamps made out of 40 x 6mm flat iron, necessary bolts, nuts, washers etc complete and painting the bracket and clamps with 2 coats of synthetic enamel paint over a coat of red oxide zinc chromate primer allasspecified and directed. |
| 144 | S&F PVCweather proof, hinged door, junction box with 10A Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unserviceable junction boxallasspecified and directed. Make : Sintex- Cat No. GSJB 2014 or equivalent as approved from list of makes specified in tender documents. |
| 145 | M&L for preparation of surface of steel tubuler poles including cross arms, channels, clamps, street light brackets and GI protection pipes etc which are fitted on pole, by scrapping and applying two coats of aluminium paint and marking pole Nos on each pole with red and black colour radium paint alternate strips, 15 cm in width of each strip upto 1 m from bottom of the pole all as specified and as directed. |
| 146 | M&L for scrapping old paints, preparation of surface oftwo pole structure including cross arms, channels, clamps etc and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and as directed. |
| 147 | M&L for scrapping old paints, preparation of surface offour pole structure including cross arms, channels, clamps etc and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and as directed. |
| 148 | S&F lightening arrester, expulsion type complete with all fitting , transmission class ,discharge capacity 65 KA , suitable for 11 000 V complete all as specified and as directed . |
| 149 | Taking out unserviceable Gang Operated Device(GOD) and supply and fixing triple pole mechanically operated with fifteen insulator , 11000 volts grade gang operated air break switch (GOD) horizontally / vertically operated complete with operating mechanism using GI pipe 25mm dia suitable for operating mechanism working from ground level for current rating upto 200 Amps capacity complete as specified & as directed. |
| 150 | S&F in replacement of dropout fuse unit, expulsion type for outdoor air break switch (GOD) single pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 10-60 Amps only all as specified and directed. |
| 151 | Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT Panel box (Design as approved by GE),Indoor type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron 45 cm above ground and 45cm grounted in ground with PCC 1:2:4 Type B1 and coping 30cm above ground level,well Ventilated, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangementand including dismantling/ taking down old unserviceable LT feeder piller box , comprises of following. Incoming : (a)MCCB 200 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No(b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, mounted on insulators for incomming supply - 01 Set. (c)digital Volt meter,415 volts, 50 Hz AC supply -01 set.(d)digitalAmp meter,415 volts, 50 Hz AC supply -01 set. (e)Neon indicating lamps (R, Y & B) -01 Set.(f) Control MCB1P 6 Amp - 04 No ,(g) CT 200/5 - 04 NoOutgoing : (a)MCCB 25 to 100 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 05 No (b) digital Volt meter,415 volts, 50 Hz AC supply -05 set.(c)digitalAmp meter,415 volts, 50 Hz AC supply -05 set. (d)Neon indicating lamps (R, Y & B) -05 Set. |