| 1 | AIR CONDITIONER (WINDOW TYPE) |
| 2 | M&L for servicing of AC 1.5/2.0 Ton Window type AC by taking out/down from existing position/location and re-installation after, Washing and Cleaning Cooling Coil by providing water bag so that water does not spill on floor and cleaning Condenser along with Fittings First with Air Blower, then with spraying with coil cleaning chemical (Non-acidic type) of best quality in Coil and Condenser, then washing with Plain Fresh Water with the help of high pressure water gun until all Chemicals are removed and Testing, complete all as specified and as directed.Note: 1. Water bag for the servicing so that water does not spill on floor shall be provided by contractor at no extra cost.2. Descaling chemical shall be measured seperately |
| 3 | S&F Fan Blade with Allen Nuts (as approved) suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 4 | S&F Fan Motor (as approved) suitable for following make of AC Voltas/LG/Bluestar/ Carrier/ Hitachi/Samsung of AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 5 | S&F capacitor of any type and size for reciprocating/rotary compressor of AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 6 | S&F blower suitable for AC 1.0/1.5/2.0 Ton Window Type including taking out/down unserviceable one, complete all as specified and as directed. |
| 7 | S&F Selector Switchsuitable for following make of AC Voltas/LG/Bluestar/Carrier/ Hitachi /samsung AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 8 | M&L Sealed Compressor Unit,reciprocating/rotary, suitable for following make of AC Voltas/LG/Bluestar/Carrier/Hitachi/Samsung for AC 1.5/2.0 Ton Window type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing including taking out/ down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Note: (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.(b) Charging of refrigerant is deem to be included in Quoted Unit Rate |
| 9 | M&L Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter and Air Filter of AC 1.5/ 2.0 Ton Window type, testing on completion, complete all as specified and as directed. |
| 10 | M&L for fault finding of unserviceable window AC and rectifying the same complete all as specified and as directed.Note: Parts replaced for rectifying the fault of window AC shall be measured seperately. |
| 11 | AIR CONDITIONER (SPLIT TYPE) |
| 12 | M&L for servicing of AC 1.5/2.0 Ton Split AC by taking out/down from existing position/location and re-installation after, Washing and Cleaning Cooling Coil by providing water bag so that water does not spill on floor and cleaning Condenser along with Fittings First with Air Blower, then with spraying with coil cleaning chemical (Non-acidic type) of best quality in Coil and Condenser, then washing with Plain Fresh Waterwith the help of high pressure water gun until all Chemicals are removed and Testing, complete all as specified and as directed.Note: 1. Water bag for the servicing so that water does not spill on floor shall be provided by contractor at no extra cost.2. Descaling chemical shall be measured seperately |
| 13 | M&L for fault finding in Auto Circuit Plate 220 Volt, 50Hz suitable for following make of AC Voltas/LG/Bluestar/ Carrier/Hitachi/samsung 1.0/1.5/2.0 Ton AC of any type (Window/Split) and rectifying the fault by replacing the whichever part is defective i.e. capacitor, resistor, varistor, IC chip, capacitor, relay or any other part that is required to rectify the fault including taking out/ down and refitting the auto circuit plate, complete all as specified and as directed. |
| 14 | S&F Fan Blade with Allen Nuts (as approved) suitable for AC 1.5/2.0 Ton Spilt type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 15 | S&F Fan Motor (as approved) suitable for following make of AC Voltas/LG/ Bluestar/ Carrier/ Hitachi/samsung for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 16 | S&F Blower Motor (as approved) suitable for following make of AC Voltas/LG/ Bluestar/ Carrier/ Hitachi/samsung for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 17 | S&F Blower suitable for following make of AC Voltas/LG/ Bluestar/ Carrier/ Hitachi/samsung for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 18 | S&F Copper Tubing of any size and make size suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 19 | S&F Insulation Sleeve type of Best quality for Copper Tubing for Suction/ Discharge Pipe any size including taking out/down unserviceable one, complete all as specified. |
| 20 | S&F Plastic PVC Pipe of 15mm bore heavy duty, ISI mark as Drain Pipe of ACs Split type, fixed to Wall with necessary Mild Steel Clamps, Screws, etc. including taking out/ down unserviceable one, complete all as specified and as directed. |
| 21 | S&F capacitor of any size and make suitable for reciprocating/rotary compressor ofAC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 22 | S&F Starting Relay Assembly with Cover & Clip suitable for AC 1.5/ 2.0 Ton capacity, Split type including taking out/ down unserviceable one, complete all as specified and as directed. |
| 23 | M&L Sealed Compressor Unit suitable for following make of AC Voltas/LG/Bluestar/Carrier/ Hitachi/Samsung for AC 1.5/2.0 Ton Split type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, and Compressor Oil, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and testing on completion including taking out/down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. NOTE :- (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.(b) Charging of refrigerant shall be deemed to be included in Quoted Unit Rate. |
| 24 | M&L Taking out Fan Motor suitable for following make of AC Voltas/LG/Bluestar/Carrier/ Hitachi/samsung AC 1.5/2.0 Ton Split type, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of insulating materials, winding, varnishing and drying well after varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, Testing on Load after fixing, complete all as specified and as directed. |
| 25 | Dismantling existing AC 1.5/2.0 Ton Split type including Outdoor and Indoor Unit & installation of Compressor Unit of AC 1.5/2.0 Ton Split type fixing of Air Conditioner on wall with necessary Mild Steel Stand, providing connection of Copper Pipes of Compressor/Air Conditioner Unit the Pipe connection should be leak proof including necessary brazing of Pipes required, providing proper insulation of Copper Pipes as per requirement Installation of Voltage Stabilizer, making connections of Electric Cable of Compressor with Air Conditioner and further to Voltage Stabilizer and Power Point including Provision of Extra quantity of Flexible Copper Conductor Cable 3 Core 1100 of size 40/0.0076 and Top Plug 15 Amp, complete all as specified and as directed. NOTE :- (a) Refilling of gas shall be deemed to be included in quoted unit rates. |
| 26 | M&L Cleaning Gas System with suitable chemical, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary of AC 1.5/ 2.0 Ton Split type, Testing on Completion, complete all as specified and as directed. |
| 27 | M&L for fault finding of unserviceable split AC and rectifying the same complete all as specified and as directed.Note: Parts replaced for rectifying the fault of split AC shall be measured seperately. |
| 28 | Supply only descaling chemical non-acidic foaming type for servicing of Split/Window AC complete all as specified as directed. |
| 29 | DESERT COOLER |
| 30 | S&F Fan Leaf of best quality suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 31 | S&F Front Grill Double Partition type of 20 SWG, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all Accessories as required incl taking out/ down unserviceable one, complete all as specified and as directed. |
| 32 | S&F Motor Kit suitable 1/7 HP, 180 Watt, 3 speed for Desert Cooler, Copper wounded completeand One Set of Lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. |
| 33 | S&F Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers including taking out/down unserviceable one, complete all as specified and as directed. |
| 34 | S&F Plastic PVC Pipe of 15mm bore suitable for Desert Cooler, heavy duty, ISI mark including taking out/down unserviceable one, complete all as specified and as directed. |
| 35 | S&F Running Capacitor 2.5/4/6mfd suitable for Fan Motor of Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. |
| 36 | S&F Selector Switch suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 37 | S&F Submersible Water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. |
| 38 | S&F Plug Top, 3 Pin, 5/6 Amp including taking out/ down unserviceable one, complete all as specified and as directed. |
| 39 | S&F PVC Round Flexible 3 Core Copper Connection Lead of size 2.5 Sqmm, 3 meter long with plug including taking out/ down unserviceable one, complete all as specified and as directed. |
| 40 | M&L Mild Steel Desert Cooler Body of 22 SWG Powder Coated with 03 Nos Side Shutters of size 3ft x 2ft x 2ft minimum size, Noise Pollution Controlcomplete Bodyincluding taking out/ down unserviceable one, complete all as specified and as directed. |
| 41 | M&L Taking out Fan Motor from Desert Cooler any size and Make, 230 Volts, 50 Cycles, removing burnt Winding Wire, rewinding the Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of Insulating Materials, winding, Varnishing and drying well after Varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed. |
| 42 | S&F Mild Steel stand for supporting fan motor of desert cooler including taking out/down unserviceable one and fixing new one with the help of screws,complete all as specified and as directed |
| 43 | S&F Wood Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed. |
| 44 | M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying two coats of Synthetic Enamel Paint (as approved) with Spray Gun Machine and Tank with Black Bituminous Paint from Inside Tank, complete all as specified and as directed. |
| 45 | WATER COOLER |
| 46 | S&F Fan Motor with copper winding suitable for water cooler 40/80 Ltr complete with Blades suitable for including taking out/down unserviceable one, complete all as specified and as directed. |
| 47 | S&F Fan Motor with copper winding suitable for water cooler 120/120 Ltr complete with Blades suitable for including taking out/down unserviceable one, complete all as specified and as directed. |
| 48 | S&F Capacitor of any size and make suitable for compressor of Water Cooler 40/120/150 Ltr capacity including taking out/ down unserviceable one, complete all as specified and as directed. |
| 49 | S&F Self Closing Tap Brass Chromium plated 15mm suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. |
| 50 | M&L Sealed Compressor Unit suitable for Water Cooler 40/80 ltr capacity including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. |
| 51 | M&L Sealed Compressor Unit suitable for Water Cooler 120/150 Ltr/hr cooling capacity including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. |
| 52 | M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 40 Ltr/hr cooling capacity, Testing on Completion, complete all as specified and as directed. |
| 53 | M&L Cleaning Gas System charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 120/150 Ltr/hr cooling capacity, Testing on Completion, complete all as specified and as directed. |
| 54 | REFRIGERATOR |
| 55 | S&F Thermostatic Switch suitable for refrigerator of any description including taking out/ down unserviceable one, complete all as specified and as directed. |
| 56 | M&L Sealed Compressor suitable for Refrigerator 120 to 170 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. |
| 57 | M&L Sealed Compressor suitable for Refrigerator 286/310/315 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. |
| 58 | M&L Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 120 to 170 Litre, Testing on Completion, complete all as specified and as directed. |
| 59 | M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 286/310/315 Litre, Testing on Completion, complete all as specified and as directed. |
| 60 | DEEP FREEZER |
| 61 | M&L Sealed Compressor Unit suitable for Deep Freezer 400/500 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. |
| 62 | M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of deep freezer, Testing on Completion, complete all as specified and as directed. |
| 63 | S&F in replacement fan motor suitable for deep freezer of any type capcity 400/500 Ltr including necessary connection and taking down unserviceable motor complete all as specified and as directed. |
| 64 | VOLTAGE STABILIZER |
| 65 | M&L for fault finding Voltage Stabilizer 4.0/5.0 KVA of any Make, and rectifying the fault by replacing the whichever of the following part is defective i.e, relay, IC, capcitor, resistor, transformer, circuit plate or any other part required to rectify the fault, complete all as specified and as directed. |
| 66 | MISC ITEMS |
| 67 | S&F Connection Lead 3 Core, PVC insulated and sheathed Copper Cable size 2.5 Sqmm including taking out/ down unserviceable one, complete all as specified and as directed. |
| 68 | S&F MCB 32 Amp, Single Pole, 220 Volt, 50 Hz, suitable for split AC 1.5/2.0 Ton with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 69 | S&F 20 Amp metal socket with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed. |
| 70 | S&F 20 Amp metal plug with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed. |
| 71 | S&F 20 Amp AC box with metal plug and socket without MCB including taking out/ down unserviceable one, complete all as specified and as directed. |