Tender For Repair/Maintenance Of Summer Appliances Like Ceiling, Exhaust Fan Etc Under Ge (W) Mathura, mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Summer Appliances Like Ceiling, Exhaust Fan Etc Under Ge (W) Mathura. Submission Date for this Tender is 01-03-2023. Air Conditioner Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36160283
Corrigendum : Tender For Repair/Maintenance Of Summer Appliances Like Ceiling, Exhaust Fan Etc Under Ge (W) Mathura
Open Tender
Indian
Uttar Pradesh
mathura
01-03-2023

Tender Details

Tender For Repair/Maintenance Of Summer Appliances Like Ceiling, Exhaust Fan Etc Under Ge (W) Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Contract No:GE(W)/MTR/ OF 2022-23
Sl. No. Item Description
1M&L for attending daily complaints in repairs and maintenance ofceiling fans, exhaust fans and wall mounting fans/Air circulator fans lodged by the users complete to make serviceable condition with skilled electrician ofFans at Mathura Cantt and obtaining signature from users complete all as specified and directed. Note:-(a) The minor complaints (non functioning of fans, replacement of fan capacitor, flexible wire, switch, fan regulator, replacement of fan blade, replacement of fan louvers) shall be competed within 24 hrs by deploying required manpower. (b) Major complaints like rewinding of fan, replacement of metal shaft, replacement of ball bearingshall be completed within one week. (c) Contractor fails to attend the minor complaints of normal/minor nature within 24 Hrs and and major complaints within one week otherwise he shall be levied penalty of Rs 100/- per complaint per day for minor complaints and Rs 200/- per complaint per day for major complaints . (d) Contractor either himself or his accredited agent shall collect the day to day complaint slip from concern JE in the morning daily and deposit the same after complaince.
2Taking down of ceiling fan 1200/1400 mm of any make & capacity from any height and removing its blades keep aside if fan is brunt/unsv/jam for repair or replace/deffective fan regulator, switch, fan condenser and refixing the same after repair/ overhauling/rewinding complete as directed by Engineer- in- charge. Note:Rewinding, switch, fan regulator & condenser etc are measured and paid seperatly under relevant item.
3All as per ser item No 2.00(here-in-before) but for exhaust fan.
4M&L for rewinding of ceiling fan motor size 1200/1400mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including changing PVC capacitor clip & taking out old copper wire before rewinding complete all as specified. Note :Deffctive fan condenser and shaft measured and paid separtely under relavent item of this schedule.
5M&L for replacement of deffetive metal shaft by new one for ceiling fan motor of size 1200/1400mm as per exiting shape & size , including taking out old deffective shaft and testing it as specified complete all as specified and directed.
6M&L for rewinding of exhaust fan/wall mounting fan motor size 200/250/275/300 mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
7M&L for rewinding of exhaust fan motor size 375/450mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
8M&L for replacement of deffetive metal shaft by new one for exhaust fan motor of size 200/250/275/300 mm as per exiting shape & size , including taking out old deffective shaft and testing it complete all as specified and directed.
9M&L for replacement of deffetive metal shaft by new one for exhaust fan motor of size375/450mm as per exiting shape & size , including taking out old deffective shaft and testing it complete all as specified and directed.
10Dismantling and overhauling of fan motor of any size and removing unserviceable grease, bearings, bushes, split pin, nuts and bolts and cleaning withpetrol /kerosene, applying new grease and reassembling complete including replacement of wornout spares with new like split pin, nut & bolts, but excluding bearings, bushes, shaft etc. (Note: New spares except like split pin, nut bolts & washer shall be measured and paid separately as supply only) complete all as specified and directed.
11M&L for painting of ceiling fans ( motor and blades etc) of existing colour or approved by Engineer-in-Charge with super enameled paint one coat including cleaning and scraping of rusted portion all as specified and as directed.
12Supply only ball bearing of suitable size (6201/6202/6203) complete all as specified and directed.
13Supply onlyCapacitor 2.5 Mfd 230 Volts complete all as specified and directed.
14Supply only Capacitor 4.0 Mfd 230 Voltscomplete all as specified and directed.
15S&F down rod made out of 19/20 mm bore MS pipe of long 45 cm including making hole threading etc. complete all as specified and directed.
16S&F MS clamp including rubber real complete complete all as specified and directed.
17Supply only Fan regulator 200W switch type 3 Speed electronic typecomplete all as specified and directed.
18Supply only Fan regulator 200W socket type 3 Speed electronic type complete all as specified and directed.
19Supply only Fan regulator 200 W moduler type 3 Speed electronic type complete all as specified and directed.
20Supply only switch piano 5 Amp flush type ISI mark as per existing size and shapecomplete all as specified and directed.
21Supply only switch 5 Amp moduler type ISI mark as per existing size and shape complete all as specified and directed.
22Supply only exhaust fan blade set of mild steel as per existing size and shapeupto 275mm sweep approved by Engineer-in-Charge complete all as specified and directed.
23Supply only exhaust fan blade set of mild steel as per existing size and shape 300/450 mm sweep approved by Engineer-in -charge complete all as specified and directed.
24Supply only set of blade suitable for 1200mm/1400mm as per exiting size & shape as approved by Engineer-in -charge complete all as specified and directed.
25Supply only louvers made out of sheet metal and mild steel frame suitable for exhaust fan 300/450mm sweep complete with nut & bolts etc as per existing size including grouting to wall etc complete all as specified and directed.
26Supply only MS Frame suitable for exhaust fan of 200/275mm sweep complete with set oflegs for fixing complete all as specified and directed.
27Supply only MS Frame suitable for exhaust fan of 300/450mm sweep complete with set oflegs for fixing complete all as specified and directed.
28M&L for conversion of bush type ceiling fan into bearing type ceiling fan by suitable lathe machine work complete all as specified and directed.
29S&F PVC circularflexible wire multi strand three core of size 1.5 sqmm to connect from ceiling fan connector to ceiling rose complete all as specified and directed.
30M&L for rewinding of wall mountingfan motor size 400/450 mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including changing PVC gears set & taking out old copper wire before rewinding complete all as specified and directed. Note : Deffctive fan condenser and shaft measured and paid separtely under relavent item of this schedule.
31M&L for rewinding of Air circulator fan motor size 600/750 mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including changing PVC gears set & taking out old copper wire before rewinding complete all as specified and directed. Note : Deffctive fan condenser and shaft measured and paid separtely under relavent item of this schedule.
32S&F metal blade setsuitable for 400mm/450mm wall mounting fan as per existing size & shape as approved by Engineer-in -charge complete all as specified and directed.
33Taking down surface / concealed copper / aluminium point wiring (light,bell,fan,socket or power) complete, including fixtures and fittings such as switches,ceiling roses,lamp holders,pendants,sockets, regulators,tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and as directed.
34M&Lfor point wiring with PVC insulated, unsheathed 1.5 sqmm FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC concealed conduit medium grade not less than 20 mm dia ISI marked ivory colour with and including all conduit fittings and fixing accessories including not less than 1.60mm thick sunken anodised pressed steel terminal boxes/modular boxes suitable for fixing of modular face plates, 3.0 mm thick hylam sheet cover/modular plate cover for mounting switches, sockets, fan regulators etc incuding 1.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for the following:- (a) one light point controlled by one switch
35All as per item No 34.00 (here-in-before) but for bell point controlled by bell push .
36All as per item No 34.00 (here-in-before) but for one fan/exhaust point controlled by one switch.
37All as per item No 34.00 (here-in-before) but for one 3 pin socket outlet 5 Amps point controlled by one switch on independent board.
38All as per item No 34.00 (here-in-before) but for one 3 pin socket outlet 5 Amps point controlled by one switch on the same board with other switches.
39S&Fswitch piano flush button single pole standard size , one way 5 Amp 240 Voltcomplete all as specified and directed.
40S&F socket 5 amps 5 pin flush type standard size, 230 volts complete all as specified and directed.
41S&Fbell push flush type5 Amp 240 Voltcomplete all as specified and directed.
42M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.