Tender For Repair/ Maintenance Of Internal Wirings Including Fittings,Fans/Wall Fans/ Exhaust Fans/ Air Circulators, Geysers, Earthing, Building Security Light And Connected Works For Certain Bldgs Under Age E/M-Ii Of Ge (N) Mamun, mamun-Punjab

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Internal Wirings Including Fittings,Fans/Wall Fans/ Exhaust Fans/ Air Circulators, Geysers, Earthing, Building Security Light And Connected Works For Certain Bldgs Under Age E/M-Ii Of Ge (N) Mamun. Submission Date for this Tender is 27-02-2023. Electrification Work Tenders in mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36160279
Corrigendum : Tender For Repair/ Maintenance Of Internal Wirings Including Fittings,Fans/Wall Fans/ Exhaust Fans/ Air Circulators, Geysers, Earthing, Building Security Light And Connected Works For Certain Bldgs Under Age E/M-Ii Of Ge (N) Mamun
Open Tender
Indian
Punjab
mamun
27-02-2023

Tender Details

Repair/ Maintenance Of Internal Wirings Including Fittings,Fans/Wall Fans/ Exhaust Fans/ Air Circulators, Geysers, Earthing, Building Security Light And Connected Works For Certain Bldgs Under Age E/M-Ii Of Ge (N) Mamun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF INTERNAL WIRINGS INCLUDING FITTINGS, FANS/WALL FANS/ EXHAUST FANS/ AIR CIRCULATORS, GEYSERS, EARTHING, BUILDING SECURITY LIGHT AND CONNECTED WORKS FOR CERTAIN BLDGS UNDER AGE E/M-II OF GE (N) MAMUN
Sl. No. Item Description
1Taking down carefully unserviceable copper/aluminiumpoint wiring (light/fan/Bell/socket or power) complete,including fixture and fittingssuch as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sketch fitting etc removing materials to store for keeping in safe custodyfor taking credit and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed.
2M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through and incl concealedPVC conduit medium grade of dia not less than 20mm, wall thickness 1.8mm thick and connected to common earth dolly with 1.6 mm thick cadmium platedCI/GI pressed steel sunken boxes and 3 mm thick plastic laminated sheet cover fixed with brass screws complete including cutting grooves for concealed wiring for light/fan/bell point controlled by one 1 way switch complete all as specified and directed. Note: 1. Conduitshall be fixed on surface/ceiling with necessary saddles where concealing of conduit is not feasible. 2.Connections of cable with MCBs or switch/sockets shall be done through proper size copper/brass pin/U type thimbles.
3All as per item No 2but for light points controlled by two way switch .
4All as per item No. 02 but for one bell/buzzer point controlled by one bell push 5 Amp
5All as per item No 2but for one5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
6All as per item No 2but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on independentboard.
7All as per item No. 2 but for one 15Amp socket pointwith 3x2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor.
8M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed/multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through existing conduit and connected to common earth dolly with 1.6 mm thick cadmium platedCI/GI pressed steel sunken boxes and 3 mm thick plastic laminated sheet cover fixed with brass screws for concealed wiring for light/fan/bell point controlled by one 1way switch complete all as specified and directed. Note: 1. Connections of cable with MCBs or switch sockets shall be done through proper size copper/brass pin/U type thimbles.
9All as per item No. 08 but for One light point controlled by 2 way switch
10All as per item No. 08 but for one bell/buzzer point controlled by one bell push 5 Amp
11All as per item No 08 but for one5 Amp socket outlet points controlled by one switch 5 Amps one way on same board.
12All as per item No 08 but for one 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way.
13All as per item No 08 but for one one 15Amp socket pointwith 3x2.5Sqmm FRLS PVC insulated multi-strand copper conductor.
14S&F in switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
15S & F Switch Socket combination 2 in 1, 5 Amp flush type, 240 V,complete all as specified and as directed.
16S & F Switch Socket Combination 15 Amp, 5 in 1, 3 pin,240 volts complete all as specified and as directed.
17S & F socket outlet 2 in 1, 3 pin, 5 Amps, flush type with shutters, 240 volts all as specified and as directed.
18S & F socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volts all as specified and as directed.
19S & F switch 15 Amps, flush type single pole one way, 240 volts all as specified and as directed.
20S&F Bell push, flush type, 5 amp AC 230 Volt etc complete all as specified and directed.
21S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed.
22S & F switch piano flush button single pole two way 5 amp 240 volts, all as specified and as directed.
23S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
24S & F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type.
25S&F fancy type Lamp holder jumbo, PVC/Polycarbonate type with back plate complete all as specified and directed.
26Supply and fix LED lamp 12 watts 230 volts retfrofit suitable for any type lamp holder as required.
27Taking down carefully unserviceable copper/aluminium sub main wiring of any size including old broken steel/PVC conduit and removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed.
28S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing PVC concealed conduit completeall as specified and directed.
29All as per item No 28 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
30Taking down unserviceable any type of Main Switch, DB"s including MCBs incl wooden/GI/MS sheet board etc and removing from site, making good the disturbed surface of wall etc in CM 1:3 complete all as specified and as directed.
31S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SPN MCB 20 Amps complete all as specified and directed.
32S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neutral bar, earth bar and cable ties for cable managementincluding polyuthrene gasket complete all as specified and directed.
33All as per item No 32 but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
34All as per item No 32 but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
35S & F in replacement TPN DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar of rating not less than 200Amps, insulated neutral bar, earth bar and cable ties for cable managementincluding polyuthrene gasket complete all as specified and directed.
36S & F in replacement sheet metal enclosures double door VTPN MCB DB 4 way, 415 V AC, 50 Hz AC with 200 Amps copper bus bar complete with IP43, IK09 protection suitable for wall including MCCB 160 Amps, 4P, 16KA with fixed magnetic and thermal setting of same make as of DB and making connection suitable size of aluminium thimbles, making good the disturbed surface to match with existing complete all as specfied and directed.
37S&F in replacement MCCB 3 Pole 415 V fixed type, 125 Amps with breaking capacity 16 KA complete all as specified and directed.
38S & F in replacement MCB TPN 40 to 100 Amps 415 volts B curve, 50 HZ AC 10 KA complete all as specified.
39S & F in replacement MCB TP25 to 63 Amps 415 volts B curve, 50 HZ AC 10 KA complete all as specified.
40S & F in replacement MCB SPN06 -32 Amps 230 volts B curve, 50 HZ AC 10 KA complete all as specified.
41S & F in replacement MCB SP 06 to 32 Amps 230 volts B curve, 50 HZ AC 10 KA complete all as specified.
42S&F in replacement 1x18W 4ft LED 6500K 230V Tube Rod with surface/wall mounted box type fitting with all accessories complete internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
43S & F in repairs Energy efficient surface Mounted LED batten Luminire 18 watts 4" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtrcomplete all as specified and directed.
44S & F in repairs recess mounting high lumen LED flat panel 1"X4" 36Watt, panel having white powder coated CRCA body high quality PMMA diffuser suitable for 600x600 grid ceiling with highpower LED, white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed.
45S&F in replacement surface mounted 10 Watt 2" box type LED batten as mirror light with wall mounting arrangment including connecting up with 3 core flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
46S & F LED post top fitting 25 watt, powder coated aluminium die cast and spun aluminum body with clear opal diffuser, suitable for landscape lighting complete all as specified and directed.Make :- Polycab Cat No - PGR0201008 equivalant as approved.
47S & F in replacement recess mounting high lumen LED flat panel 2"X2" 36 Watt, white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed.
48S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10W with PDC aluminium housing and polycarbonate diffuser complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
49Taking down old unservicable CFL/LED bulb and Supply and fix retrofit LED bulb 15W 240volts, 50Hz complete all as specified and directed.
50S&F in replacement surface mounted scintillate LED square frameless panel capacity 18 watt , square power coated PDC aluminium body and high quality LGP & PMMA diffser, separate driver, CRI>80, BEAM ANGLE 120"complete all as specified and directed. (Make :- Polycab Cat No LD00117006 or equivalant as approved)
51Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and keeping aside for refixing and dismantling old burnt/unserviceable meter boxand removing to store for keeping in safe custodyfor taking credit and making good to disturbed surfaces of walls , floors etc. in CM 1:3 complete all as specified and directed.
52S&F in replacement sheet moulded compound (SMC) meter box fire retardant type of size not less than 600x500x150mm to enclose 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangement and flush mounting in wall incl refixing the serviceable electric meters dismantled under Srl Item No 51 and making electrical connections including cleaning of disturbed area and making good the disturbed surfacein CM 1:3 to match with existing specification complete all as specified and directed.
53M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by4 mm GI wireas earth leadby means of nuts and bolt, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) in PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fairfinish internal surface with 15 mm thick plaster in CM 1:4,funnel, including charcoal dust and common salt and specified including provision of 4mm dia GI wire upto 7.5 metre long protected by 15 mm bore light grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point andto mainswitch board as specified and testing on completion, all as shown in electrical plate No 3 of MES SSR Part -1 (2009) complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
54S & F in replacement for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan complete all as specified and directed.
55S & F LED bollard light capacity 10watt, powder coated PDC aluminium body with opal diffuser, suitable for landscape lighting, IP-65 protection, height not less than 600mm, including PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for fixing ofbollard light acomplete all as specified and directed. Make :- Polycab Cat No PGR0201022 (PCGLBH2 01 10X -600MM)or equivalant as approved
56S&F in replacementof building security light 60W luminaire, having pressure die cast aluminium housing, PC diffuser and integrated electronic driver with high efficiency, with polycarbonate cover, IP-65 protection including 32mm bore light grade GI pipe bracket,mounted on wall or roof includingall accessories viz FI clamps, fasteners, nut bolt, washer etc including connecting up with 3 core flexible copper conductor cablein flexible conduit pipe of suitable sizecomplete all as specified and directed.
57S&FLED flood light fitting 210 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP 66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole by providingMS angle iron bracket of adequate length as per site requirement with MS flat iron clamp with necessary nuts, bolts and washers etc and making cable connection complete all as specified and directed.
58Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size and ensuring all blades screwed properly before refixingincl replacement of PVC fan box round sheet and making electric connection withflexible copper conductor of size 3 core 0.50Sqmm complete all as specified and directed. (rewinding and unserviceable parts other than specified in this item if any will be measured seperately).
59Taking out burnt winding wire by cutting, cleaningslots and re-winding of AC ceiling fan motor 1400/1200mm sweepany makewith super enameled colour copper winding wire of gauge 35 SWG including, sleeve work, varnishing with 1st class insulation paper with threading complete all as specified and directed. Note:- Total weight of winding wire should not be less than 200gm. Make of winding wire: BIC/ Devidyal or equivalent make as per command approved list.
60Servicing of Exhaust fans of size upto 450 mm sweep including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size and ensuring fan blades screwed properly before refixing and making electric connection withflexible copper conductor od size 3core 0.50Sqmm complete all as specified and directed. Note: Rewinding and unserviceable parts other than specified in this item if any will be measured seperately.
61Taking out burnt winding wire by cutting, cleaningslots and re-winding of exhaust fan motor upto 380mm sweep with super enameled copper winding wire of gauge 35SWG including cutting and getting out old brunt winding, sleeve work, varnishing with E class insulation varnish, threading complete all as specified and directed.
62All as per Srl item No 61 but of size 450mm sweep.
63Supply only for replacement of old unserviceable gun metal bush of ceiling fan of size 1200/1400mm sweep as per existing size complete all as specified and directed.
64Supply only for replacement of old unserviceable capacitor AC 440 volts 2.5 mfd with copper wire terminal incl PVC clamp complete all as specified and directed.
65All as per Srl item No 64 Above but of rating 3.15mfd.
66All as per Srl item No 64 Above but of rating 4.0mfd.
67Supply only ball bearing suitable for ceiling fan/exhaust fan/wall/pedestal fan any type complete all as specified and directed.
68Supply only for replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp -02 Nos, nut ,check nut,spring washer, bolt not less tha 6.0mm dia & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweepcomplete all as specified and directed.
69Supply only in replacement of old unserviceable ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.0mm suitable for 1400/1200mm sweep ceiling fan complete all as specified & directed.
70Supply and fix down rodmade of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rodwith spray painted two coat of synthetic enamel paintover one coat of red oxide primer complete all as specified and directed.
71Supply and fix in replacement PVC canopy for ceiling fan of suitable size complete all as specified and directed.
72Supply only for replacement of casing (upper and lower) for housing ceiling fan motor of size required at site for ceiling fan 1200mm/1400mm sweep made out of powder coated CRCA sheet complete all as specified and directed.
73Supply only for replacementof old unserviceable fan blades made of MS sheet duly powder coated of type, make and colour as of existing exhaust fan suitable for size upto 380mm sweep complete all as specified.
74All as per Srl item No 73 but of size 450mm sweep.
75Deduct Total amount of SCHEDUL "A" SECTION-II (SCH OF CREDIT) Rs 94,555.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail