Military Engineer Services-MES has published Tender For Repair Maintenance Of Dg Sets, Amf Panels And Its Connected Items At Jalipa Mil Stn Under Ge Army Barmer. Submission Date for this Tender is 13-03-2023. Diesel Generators Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Feb-2023 | Corrigendum | BOQ | 28-02-2023 |
2 | 28-Feb-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-03-2023 |
3 | 07-Mar-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-03-2023 |
Sl. No. | Item Description |
1 | M&L for maintanence and servicing of 250 KVA Diesel genarator sets installed at 74 Armd Regt Make : cumminsincluding connected Alternator and carryng out routine "A" check of the engine and servicing works as listed below for smooth functioning all as per manufactures instructions and directed. (a) To check (every 50hrs/1 month wichever is earlier) (i) Lubrication greasing to all parts (ii) Check all engine level (b) Fuel system : Drain sediment from fuel tanks. (c) Air System: every 50hrs/1 month wichever is earlier (i) Clean pre Cleaner dustpan weekly (ii) Check Air cleaner restriction clean/change cleaner element if required. (d) Cooling system: Check coolent level OTHER MAINTENANCE: (i) Drainer tank (ii) Check and correct leaks (iii) Drain fuel filter.Water separator. (iv) Check belts & adjust if required Note: Engine oil/Radiator coolent oil top up will be measured and paid separately. |
2 | All as per Srlitem No.1 above but 100 KVA installed at MES pump house, Bde pump house,74 Long term Pump house and 17 Guards. |
3 | All as per Srlitem No.1 above but 82.5 KVA installed at 13 Guards. |
4 | All as per Srlitem No.1 above but 62.5 KVA installed at Main Pump House, MH, Signal Centre and 22 guards. |
5 | All as per Srl item No 01 above but 20 KVAat 22 Guards Pump house. |
6 | All as per Srl item No 01 above but 30 KVAinstalled at BdePump House. |
7 | M&L for carring out following periodical maintanence on 250 KVA Diesel genaratorsets installeed at 74 Armd Regt (a) To check (every 250 Hrs/Every 6 month) (i) Repeat "A" Lubrication(ii) Changing Engine Oil (iii) Record oil pressure. (b) Fuel system : (i) Check Hydrulic Governor oil. (ii) Check throttle linkage.(iii)Lubricant Ball joints of the throttle linkage ofHydrulic Governor. (iv) Change of Fuel filter. (v) Clean fuel tank breather.. (c) Air System: (i) Clean / Change cranckcase Breather. (ii) Check Air Pipings/durettes (d) COOLING SYSTEM: (i) Check coolant in radiator.(ii) Add coolant concentrate if required(maintaining pH value in between 7.5 to10.5) (iii) Check heat exchanger zinc (sacrificial Anode) plugs. Note: (i) Coolant oil, Engine oil utilised will be measured and paid separatly. (ii) The rate quoted must be inclusive of the necessary oil filter, fuel filter , air filter units and thegaskets, O rings and clips required for changing of the filter elements |
8 | All as per Srl item No 07 above but 100 KVA installed at MES pump house, Bde pump house and 74 Long term Pump house. |
9 | All as per Srl item No 07 above but 82.5 KVA installed at 13 Guards Pump house. |
10 | All as per Srl item No 07 above but 62.5 KVA installed at MH, Signal Centre, 22 Guards and Main Pump House. |
11 | All as per Srl item No 07 abobe but 20 KVAat 22 Guards Pump House. |
12 | All as per Srl item No 07 abobe but 30 KVAinstalled at BdePump House. |
13 | Removing the unserviceable display unit from the control panel and supply and fix in repair display unit (LCD) in the control panel of 100 KVA DG set including connecting with the necessary wiring with soldering and testing after fixing complete all as specified and directed. |
14 | M&L for servicing of Self Starter assyby disconnecting from engine and dismantling the same cleaning all accessories , replace the wornout partslike :- brushes, bushes , contact plates, jumping leads and seals, revarnishing the field coil , armatureand reassembling the same , refitting the engine and testing of250 KVA DG set complete all as specified and directed. |
15 | All as per Srlitem No 14 above but 100 KVA installed at MES pump house, Bde pump house,74 Long term Pump house and 17 Guards. |
16 | All as per Srlitem No 14 above but 82.5 KVA installed at 13 Guards Pump house. |
17 | All as per Srlitem No 14 above but 62.5 KVA installed at Main Pump House, MH, Signal Centre and 22 Guards. |
18 | All as per Srl item No 14 above but 20 KVAat22 Guards Pump House. |
19 | All as per Srl item No 14 above but 30 KVAinstalled at BdePump House. |
20 | Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 180 AH. Make: Exide/Amaron or its eqvt. |
21 | Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 150 AH. Make: Exide/Amaron or its eqvt. |
22 | Supply and filling/top up engine oil SAE 15 W - 40 [CH grade). |
23 | Supply and filling/top up Radiator coolant. |
24 | Overhauling of radiator assy of DG set 250 KVA by disconnecting and removing from eingine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion ..etc by means of acid cleanig and high pressure water washing , air cleaning , re assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses ,clips as required and specified. |
25 | All as per Srl item No 24 above but 100 KVA installed at MES pump house, Bde pump house and 74 Long term Pump house. |
26 | All as per Srl item No 24 above but 82.5 KVA installed at 13 Guards Pump house. |
27 | All as per Srl item No 24 above but 62.5 KVA installed at MH and Signal Centre. |
28 | All as per Srl item No 24 above but 20 KVAat 22 Guards Pump House. |
29 | Supply and fixing in replacement fan belts as per exisiting make for 250 KVA capacities of DG Sets. |
30 | All as per Srl item No 29 above but 100 KVA . |
31 | All as per Srl item No 29 above but 82.5/62.5 KVA . |
32 | All as per Srl item No 29 above but 20/30 KVA . |
33 | Supply and fixing in replacement Solenoid switch, 24 Volts, Suitable for 100 KVA DG SET. |
34 | Supply and fixing in replacement Engine control Unit [ IN-NT-PLUS] 24 Volts, Suitable for 100 KVA DG SET. |
35 | M & L for sevicing and calibration of governor unitin-situ including replacement of worn out parts if any and testing it for a maximum droop of 20% complete all as specified and directed for 250 KVA DG set. |
36 | All as per Srl item No 35 above but 100 KVA. |
37 | All as per Srl item No 35 above but 82.5/62.5 KVA . |
38 | All as per Srl item No 35 above but 20/30 KVA . |
39 | Supply and fixing in replacement Brass, Batteryterminals. |
40 | Repair and servicing of 100 KVA PT pump assembly and injectors by replacing the unserviceable parts like centre shaft, loading spring, relief valve-2 Nos bearings, governor barrels & plunger-1Set O-ring kits,gasket kit,injector plunger & barrel -6Nos,ball check -6Nos and calibration and phasing of injectors and FIP in test bench andreassemblingetc as required. |
41 | All as per Srl item No 40 above but 82.5 KVA . |
42 | All as per Srl item No 40 above but 62.5 KVA . |
43 | All as per Srl item No 40 above but 30/20 KVA . |
44 | S & F in repair Changeover switch 200 Amps 415 Volt with sheet metal encloser, side handle operated of Make- HPL/Havells/C&G. |
45 | S & F in reapirChangeover switch 100 Amps 415 Volt with sheet metal encloser, side handle operated of Make- HPL/Havells/C&G. |
46 | Supply and Fixing in replacement MCCBs 415 V, 50 Hz, Four pole, fixed thermal & fixed magnetic setting, rupturing capacity 25 kA of rating 160 Amps complete all as specified and directed, Make Havells/L&T/ Legrand or eqvt. |
47 | Supply and Fixing in replacement MCCBs 415 V, 50 Hz, Four pole, fixed thermal & fixed magnetic setting, rupturing capacity 25 kA of rating 125 Amps complete all as specified and directed, Make Havells/L&T/ Legrand or eqvt. |
48 | Supply and Fixing in replacement MCCBs 415 V, 50 Hz, Four pole, fixed thermal & fixed magnetic setting, rupturing capacity 25 kA of rating 100 Amps complete all as specified and directed, Make Havells/L&T/ Legrand or eqvt. |
49 | Supply, Fixing, Testing and commissioning in replacement Digital Automatic mains failure (AMF) panel (CPRI Approved) suitable for 250 KVA DG Set of CRCA Sheetenclosure of 3.15mm thickness outdoor type double door duly powder coated including 500Amp MCCBs 4P 36KA Icu=Ics=100% Microprocessor release-03 Nos, 500A TP Contactor-02 Nos, RYB indication light-03 Nos, Voltmeter, Ampere Meter, VSS, ASS, CT 250/5A-03 Nos,6A Control MCB-03 Nos, Battery charger, Aux Relay-02 Nos, Under Voltage Relay-02 Nos, On Delay Timer, Push Button-02 Nos, Control Contactor 2NO+2NC-02 Nos and A/M Selector Switch complete all as specified and directed. |
50 | Supply, Fixing, Testing and commissioning in replacement Digital Automatic mains failure (AMF) panel (CPRI Approved) suitable for 20 KVA DG Set of CRCA Sheetenclosure of 3.15mm thickness outdoor type double door duly powder coated including 63Amp MCCBs 4P 25KA Icu=Ics=100% Microprocessor release-03 Nos, 63A TP Contactor-02 Nos, RYB indication light-03 Nos, Voltmeter, Ampere Meter, VSS, ASS, CT 50/5A-03 Nos,6A Control MCB-03 Nos, Battery charger, Aux Relay-02 Nos, Under Voltage Relay-02 Nos, On Delay Timer, Push Button-02 Nos, Control Contactor 2NO+2NC-02 Nos and A/M Selector Switch complete all as specified and directed. |