Tender For Up Gradation Of Electrical Main And Sub-Main
Tender Value
3.48 Lakhs
Estimated cost
Bid Submission
14 Feb 2023
0 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
haldibari → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Up gradation Of Electrical Main And Sub-Main Up gradation Of Electrical Main And Sub-Main By Providing Changeover And Spn Db Including Ei Works At Haldibari Ps Building At Haldibari In The District Of Coochbehar.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand-607711/ L&T-LTSD08N). |
| 2 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/L&T).(i) 40A DP MCB for SPN DB. |
| 3 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/L&T).(ii) 6-32A SP MCB for SPN DB. |
| 4 | Fixing only upto 100A TPN switch fuse units/Changeover in Sheet Steel enclosure with HRC fuses on angle iron frame on wall. |
| 5 | Supplying and fixing of 18\"x12\"x1\" Wooden Plank (Sal/Sirish) on wall including fixing of Energy meter with screws & other fixing materials incl. making necessary holes and connections. |
| 6 | Supplying of 415V, 3-Phase 40A/32A Automatic Changeover with Current Limiter (ACCL) of following properties:• Settable overload current limit at DG side• Separate power consumption monitoring for Mains & Genset• Settable overvoltage & undervoltage protection• Settable TPN or SPN mode at DG side• Protection against single phasing.(L&T Cat No. AUCL03040032 or Similar as approved by EIC). |
| 7 | Dismantling of existing Energymeter, TPN Main Switch, Changeover etc to another part of same building and return the Main Swich to the Department etc. required as per direction of EIC. |
| 8 | Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size. |
| 9 | Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size. |
| 10 | Laying of cablein underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size. |
| 11 | Laying of cablein underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.i)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size. |
| 12 | Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size. |
| 13 | Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size. |
| 14 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size. |
| 15 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size. |
| 16 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size. |
| 17 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size. |
| 18 | Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel to an average depth of 3.65 Mts. |
| 19 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 20 | Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting. |
| 21 | Supplying and fixing 240V AC 1200 mm sweep Pearl Ivory 3 Blade ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.(Orient Rapid Air/Orient Ocean/Usha of similar as per instruction given by EIC.) |
| 22 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 23 | Supply & Fixing 240 V, 25 A, Modular type starter (Legrand/L&T) with 25A Modular switch type DP MCB (C Curve)/25A 5 pin socket and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 24 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Anchor make) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (For AC only). |
| 25 | Supply & Fixing 240 V, 2 nos. modular 16A plug socket with separate 2 nos. 16A Piano key type switch, indicator on requisite size of modular switch board embedded in wall and top cover (brand approved by EiC)and making necessary connections as required. |
| 26 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. |
| 27 | Supplying & Fixing of 23 cm (9\") exhaust fan including S&F of louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection etc. complete.(EPC/Usha DBB) |
| 28 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(a) Average run 7 mtr. |
| 29 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(b) On Board. |
| 30 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(c) Average run 4.5 mtr. |
| 31 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(i) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC for VTPN to SPN DB. |
| 32 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(ii) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC. |
| 33 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(iii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for Power Plug. |
| 34 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(iv) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for Circuit. |
| 35 | Supplying & Fixing Square LED Recess Panel light fitting (Havells/ Philips/ Crompton make) with die cast aluminium housing & frosted glass on ceiling complete set. Item Code: LHEBAEP71Z1W012 or Similar of specifed make. |
| 36 | Supplying & Fixing Round LED Recess Panel light fitting (Havells/ Philips/ Crompton make) with die cast aluminium housing & frosted glass on ceiling complete set. Item Code: LHEBHDP71Z1W012 or Similar of specifed make. |
| 37 | Supplying and fixing Pressure die cast housing LED bulkhead with IP66 protection and IK09 impact resistance suitable for surcace and wall mounting application by screws etc. Philips Cat No. WT202W LED6S NW PSU S2 PC or similar of Crompton/Havells as directed by EiC. |
| 38 | Supplying and fixing high performance street light luminaire with single die ceramic base high power LED light source, IP 66 protection, PDC housing & aesthetic finless design and toughened glass cover etc on wall including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of wall to light fiting through wall & bracket (without control switch) including making connections & painting.Philips Cat No. BRP 052 LED 045 CW SLMR FG S1 PSU GR or similar of Crompton/Havells as directed by EiC. |
| 39 | Supplying and Fixing GI water proof looping cable box of size 200 x 150 x 100 mm having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. |
| 40 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 0.5mx50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 41 | Connecting the equipments to earth busbar with solid GI wire 6 SWG including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. |
AI Tender Summary
Tender Timeline
Feb 07, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 14, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 16, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender