Law and Justice Local Bodies Closing in 0 days TDR #36115414

Tender For Up Gradation Of Electrical Main And Sub-Main

Issued by Local Bodies · haldibari, West Bengal
Tender Value
3.48 Lakhs
Estimated cost
Bid Submission
14 Feb 2023
0 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
haldibari → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Up gradation Of Electrical Main And Sub-Main Up gradation Of Electrical Main And Sub-Main By Providing Changeover And Spn Db Including Ei Works At Haldibari Ps Building At Haldibari In The District Of Coochbehar.

BOQ

NAME OF WORK: Upgradation of Electrical Main and Sub-Main by providing Changeover and SPN DB including EI works at Haldibari PS Building at Haldibari in the district of Coochbehar.
Sl. No. Item Description
1Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand-607711/ L&T-LTSD08N).
2Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/L&T).(i) 40A DP MCB for SPN DB.
3Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/L&T).(ii) 6-32A SP MCB for SPN DB.
4Fixing only upto 100A TPN switch fuse units/Changeover in Sheet Steel enclosure with HRC fuses on angle iron frame on wall.
5Supplying and fixing of 18\"x12\"x1\" Wooden Plank (Sal/Sirish) on wall including fixing of Energy meter with screws & other fixing materials incl. making necessary holes and connections.
6Supplying of 415V, 3-Phase 40A/32A Automatic Changeover with Current Limiter (ACCL) of following properties:• Settable overload current limit at DG side• Separate power consumption monitoring for Mains & Genset• Settable overvoltage & undervoltage protection• Settable TPN or SPN mode at DG side• Protection against single phasing.(L&T Cat No. AUCL03040032 or Similar as approved by EIC).
7Dismantling of existing Energymeter, TPN Main Switch, Changeover etc to another part of same building and return the Main Swich to the Department etc. required as per direction of EIC.
8Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size.
9Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size.
10Laying of cablein underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size.
11Laying of cablein underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.i)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size.
12Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size.
13Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size.
14Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size.
15Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size.
16Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :(a)Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(i) 3.5 Core x 25 sqmm size.
17Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :(b))Supplying of 650/1100 V grade PVC/XLPE insulated aluminium armoured Cable (Polycab/KEI/Havells).(ii) 2 Core x 4 sqmm size.
18Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel to an average depth of 3.65 Mts.
19Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
20Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
21Supplying and fixing 240V AC 1200 mm sweep Pearl Ivory 3 Blade ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.(Orient Rapid Air/Orient Ocean/Usha of similar as per instruction given by EIC.)
22Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
23Supply & Fixing 240 V, 25 A, Modular type starter (Legrand/L&T) with 25A Modular switch type DP MCB (C Curve)/25A 5 pin socket and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
24Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Anchor make) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (For AC only).
25Supply & Fixing 240 V, 2 nos. modular 16A plug socket with separate 2 nos. 16A Piano key type switch, indicator on requisite size of modular switch board embedded in wall and top cover (brand approved by EiC)and making necessary connections as required.
26Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
27Supplying & Fixing of 23 cm (9\") exhaust fan including S&F of louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection etc. complete.(EPC/Usha DBB)
28Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(a) Average run 7 mtr.
29Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(b) On Board.
30Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.(c) Average run 4.5 mtr.
31Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(i) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC for VTPN to SPN DB.
32Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(ii) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC.
33Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(iii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for Power Plug.
34Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25/20 mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. Fittings and copper socketing as required.(iv) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for Circuit.
35Supplying & Fixing Square LED Recess Panel light fitting (Havells/ Philips/ Crompton make) with die cast aluminium housing & frosted glass on ceiling complete set. Item Code: LHEBAEP71Z1W012 or Similar of specifed make.
36Supplying & Fixing Round LED Recess Panel light fitting (Havells/ Philips/ Crompton make) with die cast aluminium housing & frosted glass on ceiling complete set. Item Code: LHEBHDP71Z1W012 or Similar of specifed make.
37Supplying and fixing Pressure die cast housing LED bulkhead with IP66 protection and IK09 impact resistance suitable for surcace and wall mounting application by screws etc. Philips Cat No. WT202W LED6S NW PSU S2 PC or similar of Crompton/Havells as directed by EiC.
38Supplying and fixing high performance street light luminaire with single die ceramic base high power LED light source, IP 66 protection, PDC housing & aesthetic finless design and toughened glass cover etc on wall including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of wall to light fiting through wall & bracket (without control switch) including making connections & painting.Philips Cat No. BRP 052 LED 045 CW SLMR FG S1 PSU GR or similar of Crompton/Havells as directed by EiC.
39Supplying and Fixing GI water proof looping cable box of size 200 x 150 x 100 mm having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting.
40Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 0.5mx50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
41Connecting the equipments to earth busbar with solid GI wire 6 SWG including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.

AI Tender Summary

OUR REF NO 36115414
AUTHORITY Local Bodies
TENDER VALUE 3.48 Lakhs
LAST DATE 14-02-2023
Authority
Authority Name District Magistrate
Work Description Up gradation Of Electrical Main And Sub-Main Up gradation Of Electrical Main And Sub-Main By Providing Changeover And Spn Db Including Ei Works At Haldibari Ps Building At Haldibari In The District Of Coochbehar.
Basic Detail
Tender No 25 OF 2022-23 OF THE EXECUTIVE OFFICER, HALDIBARI
Bidding Type Tender
Location
City haldibari
State West Bengal
Key Dates
Publish Date 07 Feb 2023
Submission Date 14 Feb 2023
Open Date 16 Feb 2023
Finance
Tender Value 3.48 Lakhs
Tender Fee Ref. Documents
EMD 7000
Exemption Not Available
Document List
65f6ca95-72f0-4618-ab51-c13f22fb428f.html
SPECIALTERMSANDCONDITION.pdf
2911ii.pdf
ALLFORMS.pdf
BOQ_942154.xls
NIT2NDCALL.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 07, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 14, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

65f6ca95-72f0-4618-ab51-c13f22fb428f.html

pdf

SPECIALTERMSANDCONDITION.pdf

pdf

2911ii.pdf

pdf

ALLFORMS.pdf

xls

BOQ_942154.xls

pdf

NIT2NDCALL.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders