Uttar Pradesh Jal Nigam-UPJN has published Tender For Water Supply Reorganisation Scheme Survey Design Supply Of All Material Labour Etc For Construction Of Oht Cwr Pump House Staff Quarter Boundary Wall Site Development Laying Of Rising Main Distribution System Sitc Work Of Tubewell Including Pl. Submission Date for this Tender is 04-03-2023. Wall Construction Tenders in jalaun Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Construction OF R.C.C Clear Water Reservoir (C.W.R) cum Pump House of Various Zonal Sites |
2 | Design and supply of all labour,material T&P etc to construct RCC Clear Water Resevoir cum pump house of required capacity in all type of strata with HT, LT and meter room, MS pipes railling consisting of 3 rows and posts on the roof/doom periphery, M.S ladder from ground level to top of tank and inside the tank, locking device, CI cowl type with mosquito mesh ventilator, supply and fixing water level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint of approved make and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipe assembly and valves with by pass arrangement etc all complete as per approved design and drawing. (detail specification as per tender document) |
3 | 500 KL in Zone 1 |
4 | 450 KL in Zone 2 |
5 | 600 KL in Zone 3 |
6 | Construction of R.C.C Over Head Tank (OHT) of various capacity at different sites/zones |
7 | Design & supply of all labour material T&P etc and construct RCC over head Tank of following capacity and staging including inlet outlet washout & overflow arrangements with RCC two column staircase & 1m wide balcony,G.I pipes ralling consisting of 3 rows of 20mm dia G.I pipe and angle iron posts around balcony and at the dome periphery, M.S. ladder from balcony to top of tank and inside the tank, MS grill gate of 2 m height and box type enclosure at entrance of staircase with locking arrangement, chambers for all valves, ventilating shafts with steel frame and fixing G.I fly proof mesh of 26 gauge, CI manhole frame and covers, copper lightening conductor, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC column, fixing of water level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150mm semicircular drain around the tank, escape channel of 20m length, two coats of apex paint of approved make and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes assembly and valves with bypass arrangement etc all complete as per approved design and drawing. (detail specification as per tender document) |
8 | 1550 / 20 m stagging in Zone 2 |
9 | 1800 / 22 m stagging in Zone 2 |
10 | 2350 / 22 m stagging in Zone 3 |
11 | Add or substract according to the stagging height of OHT if increased or decreased, it also includes variation in foundation and staircase accordingly. |
12 | Renovation of Existing Over Hand Tank of following capacity in Zone 1 including repairing of floor, drain, appron, balcony walls & columns with scracping of old concrete and CC grouting with waterproofing chemical for water tightness inside and outside of container wall, fixing/reparing of railing, pipes, valves and fittings, chambers, ventilator shaft, fixing of manhole covers, water level indicator and lightning conductor, apex painting with two coats etc including all labour, material t&p etc for proper completion of work. |
13 | 350 KL/ 20 m stagging |
14 | Dismantling of Existing Old Over Head Tank of following Capacity at Zone 1 by mechnical or manual means including supply of all labour, material t&p required for completion of work with proper safety measures to be carried out during dismantling of OHT necessary to safegaurd the nearby structures and disposal of malwa or dismantelled material upto 8km lead as per directions. |
15 | 200 KL/18 m stagging |
16 | Pump House |
17 | Renovation of existing pumphouse |
18 | construction of staff quarter with pile foundationas per approved design/drawing including with pile foundationwith supply of all material, labour, t&p all complete with providing complete doors, windows, ventilators, flooring, painting, drainage, electricity, plumbing and lighting facilities as per requirement. |
19 | Type I - 2 set (3 Nos.) - 40.80 sqm |
20 | Type II (1 Nos.) - 54 sqm |
21 | Type III (1 Nos.)- 63 sqm |
22 | Demolition/dismantling of abandoned existing old staff quarters, pumphouse, store etc at Jalsansthan water works campus including shifting/disposal of dismantled malwa/scrap upto 8 km lead as per directions. |
23 | construction of Administrating building as per approved design/drawing at site demarcated with pile foundationfor the same including all labour, material t&p all complete as per reqiurement alongwith making provision of water supply testing lab with supply and installation of all necessary apparatus and euipments to completely fufill the testing requirement of potable water supplied to the consumers |
24 | Building work complete in all respect |
25 | Lab Equipments as per requirements |
26 | Construction of Boundary wall as per approved design/drawing including supply of all labour, material T&P etc to complete the work. With pile foundation andYShape M.S Angel Iron including concertina coil fencing. Including Painting departmental approved colour |
27 | Zonal water supply campus |
28 | MS Gate as per approved drawing with priming coat and paint as per specifications. |
29 | MS wicket gate as per approved drawing with priming coat and paint as per specifications. |
30 | Construction of new interlocking tile road as per approved drawing and specifications inside water work campus, levelling & plantation for asthetically development of water work campus as per directions. |
31 | Filling of good earth in lower portion at various zonal campus including levelling and dressing with proper compaction by mechnical or manual means at water work campus. |
32 | Design and construction of RWH chamber with all necessary arrangement as per approved design/drawing for Rain Water Harvesting at zonal water works and admin building etc including supply of all labour, material t&p for proper completion of work. |
33 | Distribution network |
34 | Supply of ISI Marked or its relevant code HDPE Pipes of approved make of follwing sizes (Dia in mm) with jointing materials, (Electric Fusion Coupler)specials of sizes required during constructionas per latest I.S.amendement upto site of work including loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval of Engineer. |
35 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
36 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
37 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
38 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
39 | Supply of ISI Marked or its relevant code DI K-7 Pipes of approved make of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendements upto site of work including loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer.with sectional testing |
40 | D.I. K-7/ 200 mm |
41 | D.I. K-7/ 250 mm |
42 | D.I. K-7/ 300 mm |
43 | D.I. K-7/ 350 mm |
44 | D.I. K-7/ 400 mm |
45 | Supply of following size ofSluice Valves/ Scour Valves, Fire hydrants & Air Valves of approved make as per relevent I.S or its latest amandementup to store/site of work including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. |
46 | Air Valve as per as I.S : 14845 |
47 | 20 mm. dia DI D/FAir Valve |
48 | D.I. D/F Sluice valve/ Scour valve |
49 | 100 mm dia. |
50 | 200 mm dia. |
51 | 250 mm dia. |
52 | 300 mm dia. |
53 | 350 mm dia. |
54 | 400 mm dia. |
55 | Fire hydrant (65 mm dia.) |
56 | Dismantling of following types of roads including sorting out of servicable materials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work. |
57 | Interlocking tile |
58 | C.C Road |
59 | Bituminous Road |
60 | B.O.E Road |
61 | Excavation for pipe line trenches in all type of soil requiring use of specialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surplus earth upto 50m including supply of alllabour T&P etc complete and as per direction of engineer incharge. |
62 | Cartage from local store to site of work for following size (dia in mm)HDPE pipes and specials coupling, fittings, and lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bends, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. & including sectional testing. |
63 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
64 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
65 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
66 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
67 | Cartage of DI K-7 pipes and specials of following size (dia in mm)from store to site of work, lowering them into trenches and laying, jointing true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P and all jointing material etc complete required for proper completion of work. |
68 | D.I. K-7/ 200 mm |
69 | D.I. K-7/ 250 mm |
70 | D.I. K-7/ 300 mm |
71 | D.I. K-7/ 350 mm |
72 | D.I. K-7/ 400 mm |
73 | Carting of following size of Sluice Valves/ Scour Valves, Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C support below fittings etc all complete. |
74 | 20 mm dia DI D/F Air Valve |
75 | D.I. D/F Sluice valve/ Scour valve |
76 | 100 mm dia. |
77 | 200 mm dia. |
78 | 250 mm dia. |
79 | 300 mm dia. |
80 | 350 mm dia. |
81 | 400 mm dia. |
82 | Fire hydrant (65 mm dia.) |
83 | Design and construction of R.C.C. Thrust block with cement, coarse sand, and 20mm gauges stone ballast in propotion of 1:1.5:3 in thrust block of pipe line including reinforcement and its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work as approved by Engineer. |
84 | For 250 mm to 400 mm dia |
85 | For 80 mm to 200 mm dia |
86 | Reinstatement of following types of roads including sorting out of servicable materials stacking and disposal of unservicable materials with in a distance of 50 m. including supply of required new matarials & reinstatement the same including supply of labour T&P etc. required for proper completion of work. |
87 | Interlocking tile |
88 | C.C Road |
89 | Bitumenous Road |
90 | B.O.E Road |
91 | Supply of all matarial labour T&P etc and constuction of following type of chamber as per approved design & drawing according to diretion of engineer incharge . |
92 | Sluice valve chamber |
93 | Scour Valve Chamber |
94 | Air Valve chamber |
95 | Fire hydrant chamber |
96 | Provision for shifting of house connection which are cominginpipe line alignment during excavation including all labour, material t&p etc all complete. |
97 | Upto 110 mm dia |
98 | For 125 mm to 160 mm dia |
99 | For 180 mm to 250 mm dia |
100 | Provision for Nala/Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of DI/HDPE pipe & specials of required size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. |
101 | For crossing of (1.0to 1.5 m wide) |
102 | For crossing of (1.5to 2.0 m wide) |
103 | Construction of Single Tap pillar type Stand post including all material, labour T&P etc complete |
104 | Provision for Inter Connection with existing pipeline from new pipe line including bailing out of water, fixing of clamps etc. complete for proper completion of work.including all material, labour T&P etc complete forproper completion of work. |
105 | 250 mm D.I. |
106 | 200 mm D.I. |
107 | 160 mm HDPE |
108 | 110 mm HDPE |
109 | 90 mm HDPE |
110 | Rising Main |
111 | Supply of ISI Marked or its relevant code DI K-7/K-9 Pipes of follwing sizes (Dia in mm) with jointing materials, specials of sizes required during construction included jointing as per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval of Engineer. |
112 | D.I. K-7/ 150 mm |
113 | D.I. K-7/ 200 mm |
114 | D.I. K-7/ 250 mm |
115 | D.I. K-7/ 300 mm |
116 | D.I. K-9/ 350 mm |
117 | Supply of following size ofSluice Valves/ Scour Valves, Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. |
118 | D.I. D/F Sluice valve/ Scour valve |
119 | 150 mm dia. |
120 | 200 mm dia. |
121 | 250 mm dia. |
122 | 300 mm dia. |
123 | 350 mm dia. |
124 | Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m including supply of labour specials T&P etc. required for proper completion of work |
125 | Interlocking tile |
126 | C.C Road |
127 | Bitumenous Road |
128 | B.O.E Road |
129 | Excavation for pipe line trenches in ordinary soil use ofspecialT&P etc with lift upto 1.5 m lead upto 50 m including filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50m including supply of all materials labour T&P etc complete and as per direction of engineer incharge. |
130 | Cartage of following size (dia in mm.) of DI K-7/K-9 pipes and specials includingjointingmaterials from store to site of worklowering the same into excavated pipe line tenches true toaligment and gradidient and jointing the same including testing of pipe line including supply of all materials labaour T&P etc complete and as per direction of engineer incharge |
131 | D.I. K-7/ 150 mm |
132 | D.I. K-7/ 200 mm |
133 | D.I. K-7/ 250 mm |
134 | D.I. K-7/ 300 mm |
135 | D.I. K-9/ 350 mm |
136 | Carting of following size of Sluice Valves/ Scour Valves, from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. |
137 | D.I. D/F Sluice valve |
138 | 150 mm dia. |
139 | 200 mm dia. |
140 | 250 mm dia. |
141 | 300 mm dia. |
142 | 350 mm dia. |
143 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1:1.5:3 in thrust block of pipe line including reinforcement and its bending the same with 0.08 mm thick binding wire in position and necessary shuttering including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
144 | For 250 mm to 400 mm dia |
145 | For 80 mm to 200 mm dia |
146 | Supply of all material labour T&P etc for constuction of following type of chamber as per type design & drawing according to diretion of engineer-in-charge . |
147 | Sluice valve/Scour Valve chamber |
148 | Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour specials T&P etc required for proper completion of work. |
149 | Interlocking Road |
150 | C.C Road |
151 | Bitumen Road |
152 | B.O.E Road |
153 | Making water supply house connection in New/Existing pipe line as per approved drawing and material including supply of all labour, material T&P required for proper completion of house connection work as per approved drawing, |
154 | In Kachcha Road |
155 | Upto 110 mm dia |
156 | For 300 mm dia |
157 | For 350 mm to 500 mm dia |
158 | In BOE Road |
159 | Upto 110 mm dia |
160 | For 125 mm to 160 mm dia |
161 | For 180 mm to 250 mm dia |
162 | In Cement Concrete Road |
163 | Upto 110 mm dia |
164 | For 125 mm to 160 mm dia |
165 | For 180 mm to 250 mm dia |
166 | For 300 mm dia |
167 | For 350 mm to 500 mm dia |
168 | In Bituminous Road |
169 | Upto 110 mm dia |
170 | For 125 mm to 160 mm dia |
171 | For 180 mm to 250 mm dia |
172 | For 300 mm dia |
173 | In Interlocking Road |
174 | Upto 110 mm dia |
175 | For 125 mm to 160 mm dia |
176 | For 180 mm to 250 mm dia |
177 | ELECTRICAL AND MECHANICAL WORKS (Supply, storage,testing and comissioning and Trail & Run of Following as per details) |
178 | CONSTRUCTION OF (9No)NEW & (2No)REBORE TUBEWELLS |
179 | Resistivity Survey of Tubewell Site |
180 | Transportation of rig machine erection, dismantling and associated T&P Complete in all respect including required all material , labour etc. |
181 | DRILLING OF TUBEWELL BORE |
182 | Drilling of 550 mm. dia bore from G.L. to 100M. BGL (100mx11No) |
183 | Drilling of 550 mm. dia bore from 101 BGL to 120M. BGL (20mx11No) |
184 | Logging of bore hole by electirc logger |
185 | TUBEWELL ASSEMBLY |
186 | M.S. tube well assembly with all required parts like plain pipe, slotted pipe rings,, well cap, bail plug clamp, reducer, central guide, support structure etc. as required and as per typed design complete in all respect. |
187 | 300 mm. dia 7.1 mm thick MSERW Plain Pipe with MS ring & reducer(60mx11No) |
188 | 200 mm.dia 7.1 mm thick M.S. Plain pipe & Slotted pipe with MS ring(50mx11No) |
189 | Lowering of tubewell assembly duly welded including welding electrode and shrounding of pea Gravel complete in all respect. |
190 | 300 mm. dia 7.1mm thick MSERW Plain/Slotted Pipe |
191 | 200 mm. dia Plain/Slotted Pipe 61 M. BGLto 110 M. BGL |
192 | DEVELOPMENT OF TUBEWELL |
193 | Transportation, Erection, Dismantling of 250 P.S.I. Compressor. |
194 | Development by 250 P.S.I. Compressor |
195 | Transportation, Erection, Dismantling of 2 Cusec O.P. Unit and yeild Test. |
196 | Development by 2 Cusec/Suitable capacity O.P. Unit |
197 | Chemical and Bacteriological test of water sample form departmentel / approved lab. |
198 | Supply & Shrouding of Lal Kuan Pea Gravel 1.6 to 4.8 mm. size for Tubewell |
199 | PUMPING PLANT FOR NEW AND REBORE TUBWELLS WITH PAINTING WORK |
200 | Supply, installation,testing and commissioning of Clear water submersible pump (IS 9236) complete with electric motor (IS 8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. supply of 1000 Lpm, 60 mtr Head or as per design & HP as per Design with margin according to CEEPHO manual |
201 | Supply, installation,testing and commissioning of Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house (Internal & External)and gauges complete in all respect with all required material, T&P labour 100 mm Dia. size |
202 | Supply, installation,testing and commissioning of 3 Mtr Long Heavy duty exta Coloum pipe 100 mm Dia. Size (8 Nos for each TW) |
203 | Supply, installation,testing and commissioning of Electrically Operated Actuater suitable for 100 mm Size sluice valves (1No for Each TW) |
204 | Supply, installation,testing and commissioning of Submersible flat copper condutor cable 1x3Cx4mm2 PVC Sheathed double run (1x2Rx30m=60m for each TW) |
205 | Supply, installation,testing and commissioning of PVC Sheathed Aluminium armoured cable from UPPPCL Pole/Trasformer to Meter and Meter to Pump house 1x3.5Cx25mm2 |
206 | Supply, installation,testing and commissioning of SCADA compitable 3 Phase Control Panel with Soft stater module incuding RS 485 Port- 400 V suitable to operate TW submersible pumping plant |
207 | Supply & Installtion of 30 KVA Servo VoltageStablizer with 63Amp changeover switch |
208 | Supply, installation,testing and commissioning ofof 2 Ton 4.5 mtr lift chain pully block |
209 | Supply, installation,testing and commissioning of CE/UL Certified Electromegnatic flowmeter 100mm |
210 | Supply, installation,testing and commissioning of Auto phase reversal unit with inbuilt time delay & enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) suitable to 25 HP |
211 | Supply, installation,testing and commissioning of CE/UL Certified Pressure transmitter |
212 | Supply, installation,testing and commissioning of CE/UL Certified Surge protector for control panel |
213 | Supply, installation,testing and commissioning of Security Survelliance IP Camera with required accessories |
214 | RENNOVATION WORK OF EXSISTING WORKS WITH PAINTING WORK |
215 | Supply, installation,testing and commissioning of Clear water submersible pump (IS 9236) complete with electric motor (IS 8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. supply of 1000 Lpm, 60mtr Head or as per design & HP as per Design with margin according to CEEPHO manual |
216 | Supply, installation,testing and commissioning of Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house (Internal & External)and gauges complete in all respect with all required material, T&P labour 100 mm Dia. size |
217 | Supply, installation,testing and commissioning of 3 Mtr Long Heavy duty exta Coloum pipe 100 mm Dia. Size (8 Nos for each TW) |
218 | Supply, installation,testing and commissioning of Electrically Operated Actuater suitable for 100 mm Size sluice valves (1No for Each TW) |
219 | Supply, installation,testing and commissioning of Submersible flat copper condutor cable 1x3Cx4mm2 PVC Sheathed double run (1x2Rx30m=60m for each TW) |
220 | Supply, installation,testing and commissioning of SCADA compitable 3 Phase Control Panel with Soft stater module incuding RS 485 Port- 400 V suitable to operate TW submersible pumping plant |
221 | Supply & Installtion of 30 KVA Servo VoltageStablizer with 63Amp changeover switch |
222 | Supply, installation,testing and commissioning of CE/UL Certified Electromegnatic flowmeter 100mm |
223 | Supply, installation,testing and commissioning of Auto phase reversal unit with inbuilt time delay & enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) suitable to 25 HP |
224 | Supply, installation,testing and commissioning of CE/UL Certified Pressure transmitter |
225 | Supply, installation,testing and commissioning of CE/UL Certified Surge protector for control panel |
226 | Supply, installation,testing and commissioning of Security Survelliance IP Camera with required accessories |
227 | PUMPING PLANT AT 500 KL CWR (ZONE - 1) CWR feed from 6No TW"s (3exsisting+3new) |
228 | (A) VT Pumping Plant :- Supply of 1400 LPM,Head as per actual design , 1450 RPM , S.S 410 impeller & shaft,Pump Casing 2% NiCi,IS:210 FG: 260 Self Water Lubricated VT Pump set coupled with squirrel cage VHS/VSS TEFC IP-55 induction motor (Operating Voltage 415 V + 10%, 3 ph, 50Hz + 5%) as per actual design including according to CEEPHO manual with Bowl Assembly Discharge Head, Head Shaft, Strainer and 5 mts (or suitable sump depth) Column Assembly to feed 350 KL Exsisting OHT (1w+1s) |
229 | (B) VT Pumping Plant :- Supply of 2400 LPM,Head as per actual design, 1450 RPM , S.S 410 impeller & shaft,Pump Casing 2% NiCi,IS:210 FG: 260Self Water LubricatedVT Pump set coupled with squirrel cage VHS/VSS TEFC IP-55 induction motor (Operating Voltage 415 V + 10%, 3 ph, 50Hz + 5%) as per actual design including according to CEEPHO manual with Bowl Assembly Discharge Head, Head Shaft, Strainer and 5 mts (or suitable sump depth) Column Assembly to feed 1550 KL New OHT (2w+1s) |
230 | CONTROL PANNEL :- |
231 | Supply of M.S. Fabricated Dust and Vermin Proof, Cubical Type, Floor Mounted, Control Panel compitable to SCADA with RS485 Port consisting as following INCOMING :-1 No. M.C.C.B. motorised & microprocessor based250 Amp capacity OUTGOING :- (i) 2 Nos. Outgoing Consist of SCADA Compatible Motorised M.C.C.B. microprocessor based 80Amp Capacity, suitable to operate 25 HP induction motor (ii) 3 Nos. Outgoing Consist of SCADA Compatible Motorised M.C.C.B.microprocessor based 100 Amp Capacity, suitable to operate 40 HP induction motor (iii) 2 Nos MCCB 63 Amp for lighting and fan Control Panel / Starter :- (i) 2 Nos. 25 H.P Soft starter with Ampere Meter, Power Capacitor, Motor protections, Indicating Lamps, Toggle Switches and Instrument Fuses suitable to SCADA operation with RS485 Port (ii) 3 Nos.40 H.P Soft Starter with Ampere Meter, Power Capacitor, Motor protections, Indicating Lamps, Toggle Switches and Instrument Fuses suitable to SCADA opertation with RS485 Port (iii) APFC Panal with SCADA compatible of suitable capacityas per design Note :- Starter and MCCB rating may be vary as per actual capacity according to site situation and no extra payment shall be made for this |
232 | supply of CE/UL Certified Surge protector for control panel |
233 | Supply of 3 Core 35 sq.mm Copper Conductor Cable from L.T. Panel to respective Motors with lugs etc. |
234 | Supply of Powder coated MS Cable Tray 150mmx50mmx1.6mm |
235 | EARTHING :-Strip Double Plate Earthing for Complete Electrical Installation in the Pump House (As per IER/IS) including civil work with all materials Individual Earthing for each equipment shall be carried out |
236 | Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) 315 Amp. |
237 | MAIN PIPING AND VALVES :-( for 1400 LPM VT Pumps) |
238 | Reflex Valve 150 mm size CIDF PN 1.0 |
239 | Sluice Valve 150 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
240 | Sluice Valve 150 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) for common header |
241 | Sluice Valve 150 mm Size CIDF PN 1.0 (Manual for Bypass) |
242 | Main Pipings 1. 150 x 150 x 150 mm MS D/F Tee (12mm thickness) - 3 No 2. 150 mm MS D/F Pipe 0.50 mt. (12mm thickness) - 3 No 3. 150 mm MS D/F Pipe 1.00 mt.(12mm thickness) - 3 No 4. 150 mm MS D/F Pipe 2.00 mt. (12mm thickness) - 3 No 5. 150 mm MS D/F (12mm thickness) Bend 90o - 3 No 6. 150 mm Blind Flange - 1 No 7. Necessary Nut Bolt’s & Rubber Packing - 1 Lot And all other specials required to complete the work in proper manner |
243 | MAIN PIPING AND VALVES :-( for 2400 LPM VT Pumps) |
244 | Reflex Valve 150 mm size CIDF PN 1.0 |
245 | Sluice Valve 150 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
246 | Sluice Valve 200 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) for common header |
247 | Sluice Valve 200 mm Size CIDF PN 1.0 (Manual for Bypass)- 1 No |
248 | Main Pipings 1. 200 x 150 x 200 mm MS D/F Tee (12mm thickness) - 3 No 2. 150 mm MS D/F Pipe 0.50 mt. (12mm thickness) - 3 No 3. 150 mm MS D/F Pipe 1.00 mt. (12mm thickness) - 3 No 4. 200 mm MS D/F Pipe 2.00 mt. (12mm thickness) - 3 No 5. 200 mm MS D/F Bend 90o - 3 No 6. 200 mm Blind Flange - 1 No 7. Necessary Nut Bolt’s & Rubber Packing - 1 Lot (S.S.) Including all other specials required to complete the work in proper manner |
249 | 3 Ton Capacity 6.00 mt Lifting Tackle Manual with traveling trolley chain pully block & double gurder H type |
250 | Tools & Spanner Pipe wrenches - 2No D/E Spanner 22/6 mm - 6No Adjustable wrench 300 mm - 1No Screw driver/Tester 250 mm - 1No Screw driver/Tester 200 mm - 1No Screw driver/Tester 150 mm - 1No Combination pliers 200 mm - 1No Nose pliers 150 mm - 1No Hammer with handle 1 kg. - 1No Line tester (Taparia make) - 1No Cripming tool of suitable size - 1No |
251 | CO2/ABC Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
252 | 200 mm diameter, CE/UL Certified Electromagnetic type flow meter digital reading |
253 | 150 mm diameter, CE/UL Certified Electromagnetic type flow meter digital reading |
254 | Internal & External electrification of CWR & Substation with 5 nos solar street lights |
255 | Electromegnatic dozzer of suitable capacity SCADA compatible |
256 | CE/UL Certified Pressure transmitter for each pump |
257 | CE/UL Certified Residual cholorine sensor at OHT outlet |
258 | CE/UL Certified Radar type Level sensor with RTU communication for OHT |
259 | CE/UL Certified Ultrasonic Level sensor for CWR |
260 | CE/UL Certified Electomgnatic flow meter at OHT outlet of suitable size |
261 | Security Survelliance IP Camera (optional) |
262 | 1feet hight MS stand for LT Panel made fromMS angle iron |
263 | Testing of Pumping Plant & Control Panel at Manufacturer Works |
264 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -1 includingpainting of pumping plants. |
265 | 160 KVA SUB STATION AT CWR 500 KL (Zone-1) |
266 | Indoor type floor mounted metal clad, 11 KV VCB HT panel with 1No. incoming VCB & 2Nos outgoing VCB totally enclosed, horizontal drawout, horizontal/ vertical isolation type breaker as per IS with all necessory protection and also should be compatible to SCADA operation with RS485 port and multifunction meter. |
267 | 70 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to H.T. incoming Panel, and H.T. panel to Transformer. |
268 | 160 KVA, 11/0.44 KV, 3 Phase, 50 Hz, Dyn11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +7.5% & -15%,LV side @ 2.5% each tapping complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 (Revised) & as per specificationcomplete in all respects as required at site. |
269 | H.T. Cable end termination heat shrink joint kit Indore Type 70 sq.mm. |
270 | H.T. Cable end termination heat shrink joint kit Outdoor Type 70 sq.mm. |
271 | Earthing system shall executed as per IS : 3043 and I.E. rules. |
272 | Sheet fabricated factory wired, floor mounting type L.T. panel comprising of following. L.T. panel comprising of 2 no incomer MCCB of 250 Amp capacity panel and 1 no. outgoing 250 Amp MCCBand 1 nos 250 Amp for DG set for future planning (all are electrically and mechanicaly interlockd) & 1Nos 63 Amp MCCB for lighting complete panel of suitable for above 160 KVA transformers. All MCCB should be motorised and microprocessor based compatable for SCADA |
273 | 1.1 KVgrade 120 sq mm 3.5 core PVCinsulated Armored Aluminum cable from160 KVA Transformer to L.T. Panel. |
274 | Rubber Sheet of size 1mX2m and 19 mm thick shock resistance sheet |
275 | Supply , Installation of transformer Sub – station Fencing with painting complete. |
276 | CO2/ABC Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
277 | Testing of HT,LT Panel & Transformer at Manufactrer works |
278 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -1 substation. |
279 | NOC for substation from electrical sefety department |
280 | PUMPING PLANT AT 450 KL CWR (ZONE - 2) CWR feed from 6No TW"s (2exsisting+3new) |
281 | VT Pumping Plant :- Supply of2600 LPM, 40 mtr Head or as per actual design , 1450 RPM , S.S 410 impeller & shaft,Pump Casing 2% NiCi,IS:210 FG: 260 Self Water Lubricated VT Pump set coupled with squirrel cage VHS/VSS TEFC IP-55 induction motor (Operating Voltage 415 V + 10%, 3 ph, 50Hz + 5%) 40 HP or as per actual design including CEEPHO margin with Bowl Assembly Discharge Head, Head Shaft, Strainer and 5 mts Column Assembly to feed 2150 KL OHT (2w+1s) |
282 | L.T PANEL WITH CONTROL PANNEL :- |
283 | Supply of M.S. Fabricated Dust and Vermin Proof, Cubical Type, Floor Mounted, LT Panel with Control Panel compitable to SCADA with RS485 Port consisting as following INCOMING (from Transformer) :-2 No. M.C.C.B. motorised & microprocessor based250 Amp capacity (electrically & mechanically interlocked) & 1 No. M.C.C.B. motorised & microprocessor based250 Amp capacity & Outgoing 1 No. M.C.C.B. motorised & microprocessor based250 Amp capacity (for DG set ) both are electrically & mechanically interlocked,Volt Meter with Selector Switch, Ampere meter with selector switch, KWH smart meter ,Power Factor meter, Frequency Meter, Indicating lamps, Toggle switch, Instrument fuses and Aluminum Bus Bar. OUTGOING :- (i) 3 Nos. Outgoing Consist of SCADA Compatible Motorised M.C.C.B. microprocessor based 100 Amp Capacity, suitable to operate 40 HP induction motor (ii) 2 Nos MCCB 63 Amp for lighting and fan Control Panel / Starter :- (i) 3 Nos. 40 H.P Soft starter with Ampere Meter, Power Capacitor, Motor protections, Indicating Lamps, Toggle Switches and Instrument Fuses suitable to SCADA operation with RS485 Port (ii) APFC Panel SCADA Compatible of suitable capacity as per design Note :- Starter and MCCB rating may be vary as per actual capacity according to site situation and no extra payment shall be made for this |
284 | supply of CE/UL Certified Surge protector for control panel |
285 | Supply of 3 Core 35 sq.mm Copper Conductor Cable from L.T. Panel to respective Motors with lugs etc. |
286 | Supply & Fixing of Powder coated MS Cable Tray 150mmx50mmx1.6mm |
287 | EARTHING :-Strip Double Plate Earthing for Complete Electrical Installation in the Pump House (As per IER/IS) including civil work with all materials Individual Earthing for each equipment shall be carried out |
288 | Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) 315 Amp. |
289 | MAIN PIPING AND VALVES :-( for 2500 LPM VT Pumps) |
290 | Reflex Valve 200 mm size CIDF PN 1.0 |
291 | Sluice Valve 200 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
292 | Sluice Valve 250 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
293 | Sluice Valve 250 mm Size CIDF PN 1.0(Manual for Bypass) |
294 | Main Pipings 1. 250 x 200 x 250 mm MS D/F Tee (12mm thickness) - 3 No 2. 200 mm MS D/F Pipe 0.50 mt.(12mm thickness) - 3 No 3. 200 mm MS D/F Pipe 1.00 mt. (12mm thickness) - 3 No 4. 250 mm MS D/F Pipe 2.00 mt.(12mm thickness) - 3 No 5. 250 mm MS D/F (12mm thickness) Bend 90o - 3 No 6. 250 mm Blind Flange - 1 No 7. Necessary Nut Bolt’s & Rubber Packing - 1 Lot Including all other specials required to complete the work in proper manner |
295 | 3 Ton Capacity 6.00 mt Lifting Tackle Manualwith traveling trolley chain pully block& double gurder H type |
296 | CO2/ABC Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
297 | 250mm diameter, CE/UL Certified Electromagnetic type flow meter digital reading |
298 | CE/UL Certified Electomgnatic flow meter at OHT outlet of suitable size |
299 | Internal & External electrification of CWR & Substation with 5 nos solar street lights |
300 | Electromegnatic dozzer of suitable capacity SCADA compatible |
301 | CE/UL Certified Radar type Level sensor with RTU communication for OHT |
302 | CE/UL Certified Ultrasonic Level sensor for CWR |
303 | CE/UL Certified Pressure transmitter for each pump |
304 | CE/UL Certified Residual chlorine sensor at OHT outlet |
305 | Security Survelliance IP Camera with all required accessories |
306 | 1feet hight MS stand for LT Panel made fromMS angle iron |
307 | Testing of Pumping Plant & Control Panel at Manufacturer Works |
308 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -2includingpainting of pumping plants. |
309 | 100 KVA SUB STATION AT CWR 450 KL (Zone-2) |
310 | Indoor type floor mounted metal clad, 11 KV VCB HT panel with 1No. incoming VCB & 2Nos outgoing VCB totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS with all necessory protection and also should be compatible to SCADA operation with RS485 port and multifunction meter. |
311 | 70 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to H.T. incoming Panel, and H.T. panel to Transformer. |
312 | 100 KVA, 11/0.44 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +7.5% & -15%, LV side @ 2.5% stapping complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 (Revised) & as per specificationcomplete in all respects as required at site. |
313 | H.T. Cable end termination heat shrink joint kit indoortype 70sq.mm. |
314 | H.T. Cable end termination heat shrink joint kit outdoor type 70sq.mm. |
315 | Earthing system shall executed as per IS : 3043 and I.E. rules. |
316 | 1.1 KVgrade 120 sq mm 3.5 core PVCinsulated Armored Aluminum cable fromTransformer to L.T. Panel. |
317 | Rubber Sheet of size 1mX2m and 19 mm thick shock resistance sheet |
318 | Supply , Installation of transformer Sub – station Fencing with painting complete. |
319 | CO2 Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
320 | Testing of HT Panel & Transformer at Manufactrer works |
321 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -2 substation. |
322 | NOC for substation from electrical sefety department |
323 | PUMPING PLANT AT 600 KL CWR (ZONE - 3) CWR feed from 7No TW"s (4exsisting+3new) |
324 | VT Pumping Plant :- Supply of3650 LPM, 40 mtr Head or as per actual design , 1450 RPM , S.S 410 impeller & shaft,Pump Casing 2% NiCi,IS:210 FG: 260 SelfWater Lubricated VT Pump set coupled with squirrel cage VHS/VSS TEFC IP-55 induction motor (Operating Voltage 415 V + 10%, 3 ph, 50Hz + 5%) 50 HP or as per actual design including according to CEEPHO manual with Bowl Assembly Discharge Head, Head Shaft, Strainer and 4.5 mts Column (or suitable sump depth) Assembly to feed 2350 KL OHT (2w+1s) |
325 | L.T PANEL WITH CONTROL PANNEL :- |
326 | Supply of M.S. Fabricated Dust and Vermin Proof, Cubical Type, Floor Mounted, LT Panel with Control Panel compitable to SCADA with RS485 Port consisting as following INCOMING (from Transformer) :-2 No. M.C.C.B. motorised & microprocessor based320 Amp capacity (electrically & mechanically interlocked) & 1 No. M.C.C.B. motorised & microprocessor based320 Amp capacity & Outgoing 1 No. M.C.C.B. motorised & microprocessor based320 Amp capacity (for DG set ) both are electrically & mechanically interlocked,Volt Meter with Selector Switch, Ampere meter with selector switch, KWH smart meter ,Power Factor meter, Frequency Meter, Indicating lamps, Toggle switch, Instrument fuses and Aluminum Bus Bar. OUTGOING :- (i) 3 Nos. Outgoing Consist of SCADA Compatible motorised M.C.C.B. microprocessor based 125Amp Capacity, suitable to operate 50 HP induction motor (ii) 2 Nos MCCB 63 Amp for lighting and fan Control Panel / Starter :- (i) 3 Nos. 50 H.P Soft starter with Ampere Meter, Power Capacitor, Motor protections, Indicating Lamps, Toggle Switches and Instrument Fuses suitable to SCADA operation with RS485 Port (iii) APFC Panel SCADA Compatible of suitable capacity as per design Note :- Starter and MCCB rating may be vary as per actual capacity according to site situation and no extra payment shall be made for this |
327 | CE/UL Certified Surge protector for control panel |
328 | Supply of 3 Core 35 sq.mm Copper Conductor Cable from L.T. Panel to respective Motors with lugs etc. |
329 | Supply & Fixing of Powder coated MS Cable Tray 150mmx50mmx1.6mm |
330 | EARTHING :-Strip Double Plate Earthing for Complete Electrical Installation in the Pump House (As per IER/IS) including civil work with all materials Individual Earthing for each equipment shall be carried out |
331 | Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) 315 Amp. |
332 | MAIN PIPING AND VALVES :-( for 3500 LPM VT Pumps) |
333 | Reflex Valve 200 mm size CIDF PN 1.0 |
334 | Sluice Valve 200 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
335 | Sluice Valve 250 mm Size CIDF PN 1.0 ( with actuater suitable to SCADA operation) |
336 | Sluice Valve 250 mm Size CIDF PN 1.0 (Manual for Bypass) |
337 | Main Pipings 1. 250 x 200 x 250 mm MS D/F Tee (12mm thickness) - 3 No 2. 200 mm MS D/F Pipe 0.50 mt.(12mm thickness) - 3 No 3. 200 mm MS D/F Pipe 1.00 mt.(12mm thickness) - 3 No 4. 250 mm MS D/F Pipe 2.00 mt.(12mm thickness) - 3 No 5. 250 mm MS D/F (12mm thickness) Bend 90o - 3 No 6. 250 mm Blind Flange - 1 No 7. Necessary Nut Bolt’s & Rubber Packing - 1 Lot Including all other specials required to complete the work in proper manner |
338 | 3 Ton Capacity 6.00 mt Lifting Tackle Manual with traveling trolley chain pully block& double gurder H type |
339 | CO2/ABC Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
340 | 250 mm diameter,CE/UL Certified Electromagnetic type flow meter digital reading |
341 | CE/UL Certified Electomgnatic flow meter at OHT outlet of suitable size |
342 | Internal & External electrification of CWR & Substation with 5 Nos solar street lights |
343 | Electromegnatic dozzer of suitable capacity SCADA compatible |
344 | CE/UL Certified Radar type Level sensor with RTU communication for OHT |
345 | CE/UL Certified Ultrasonic Level sensor for CWR |
346 | CE/UL Certified Pressure transmitter for each pump |
347 | CE/UL Certified Residual cholorine sensor |
348 | Security Survelliance IP Camera with required accessories |
349 | Testing of Pumping Plant & Control Panel at Manufacturer Works |
350 | 1feet hight MS stand for LT Panel made fromMS angle iron |
351 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -3 includingpainting of pumping plants. |
352 | 160 KVA SUB STATION AT CWR 600 KL (Zone-3) |
353 | Indoor type floor mounted metal clad, 11 KV VCB HT panel with 1No. incoming VCB & 2Nos outgoing VCB totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS with all necessory protection and also should be compatible to SCADA operation with Rs485 port and multifunction meter. |
354 | 70 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to H.T. incoming Panel, and H.T. panel to Transformer. |
355 | 160 KVA, 11/0.44 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +7.5% & -15%, LV side @2.5% stapping complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 (Revised) & as per specificationcomplete in all respects as required at site. |
356 | H.T. Cable end termination heat shrink joint kit indore type 70 sq.mm. |
357 | H.T. Cable end termination heat shrink joint kit out door type 70 sq.mm. |
358 | Earthing system shall executed as per IS : 3043 and I.E. rules. |
359 | 1.1 KVgrade 120 sq mm 3.5 core PVCinsulated Armored Aluminum cable from160 KVA Transformer to L.T. Panel. |
360 | Rubber Sheet of size 1mX2m and 19 mm thick shock resistance sheet |
361 | Supply , Installation of transformer Sub – station Fencing with painting complete. |
362 | CO2/ABC Dry Powder type Fire Extinguisher 4.5 kg as per IS:15683 |
363 | Testing of HT Panel & Transformer at Manufactrer works |
364 | Installation. Commissioning and testing of all above equipments as per approved drawings at CWR zone -3 substation |
365 | NOC for substation from electrical sefety department |
366 | SCADA WORKS OF TUBEWELLS(18 No) |
367 | Supply, storage, installation, testing and comissioning of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified. One each for each tubewell to store and transmit data on GSM backbone, RTU designed with logic to tansfer data at multiple stations and also compatible for satellite communication along with control panel for all equipment and 24V power supply |
368 | Supply, storage, installation, testing and comissioning of GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge till Handed over |
369 | Supply, storage, installation, testing and comissioning of CE & UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters |
370 | Supply, storage, installation, testing and comissioning of CE/UL Certified Intelligent energy meters with communication port |
371 | SCADA WORKS OF 500 KL CWR to 350 KL OHT & 1550 KL OHT (Zone-1) (Having 5 Nos Pumps) |
372 | Supply, storage, installation, testing and comissioning of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to tansfer data at multiple stations and also compatible for satellite communicationalong with control panel for all equipment and 24V power supply |
373 | Supply, storage, installation, testing and comissioning of GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge till Handed over |
374 | Supply, storage, installation, testing and comissioning of CE & UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters |
375 | Supply, storage, installation, testing and comissioning of CE/UL Certified Intelligent energy meters |
376 | Complete cabling for CWR & OHT (above 3 pumps) |
377 | SCADA WORKS OF 450 KL CWR to 2150 KL OHT(Zone-2) (for 3 pumps) |
378 | Supply, storage, installation, testing and comissioning of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to tansfer data at multiple stations and also compatible for satellite communication along with control panel for all equipment and 24V power supply |
379 | Supply, storage, installation, testing and comissioning of GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge till Handed over |
380 | Supply, storage, installation, testing and comissioning of CE & UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters |
381 | Supply, storage, installation, testing and comissioning of CE/UL Certified Intelligent energy meters |
382 | Complete cabling for CWR & OHT (upto 3pumps) for scada |
383 | SCADA WORKS OF 600 KL CWR to 2350 KL OHT (Zone-3) (for 3 pumps) |
384 | Supply, storage, installation, testing and comissioning of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to tansfer data at multiple stations and also compatible for satellite communicationalong with control panel for all equipment and 24V power supply |
385 | Supply, storage, installation, testing and comissioning of GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge till Handed over |
386 | Supply, storage, installation, testing and comissioning of CE & UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters |
387 | Supply, storage, installation, testing and comissioning of CE/UL Certified Intelligent energy meters |
388 | Complete cabling for CWR & OHT (upto 3pumps) for SCADA |
389 | LOCAL CONTROL STATION (LCS) FOR TW"s AND CWR"s |
390 | Supply, storage, installation, testing and comissioning of CE/UL & BIS Certified industrial grade LED MONITOR with latest configuration as per specification 65" (upto 50 Tubewells) |
391 | Supply, storage, installation, testing and comissioning of Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements |
392 | Supply, storage, installation, testing and comissioning of CE/UL certified Local control room PLC with redundant CPU & power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect |
393 | Supply, storage, installation, testing and comissioning of CE/UL certified Field gateway agent for transfering data from MCS to central control room |
394 | Supply, storage, installation, testing and comissioning of GSM/GPRS based wireless/Broadband/equivelent communication system for PLC Capable to transfer and receive data & gather data from remote sites to control stations all accessories included with signal enhancer, antenna along with running expences till DLP |
395 | Supply, storage, installation, testing and comissioning of CE/UL certified Firewall for network protection |
396 | Supply, storage, installation, testing and comissioning of Surge protector for Ethernet communication protection |
397 | Supply, storage, installation, testing and comissioning of CE/UL Certified industrial grade Ethernet switch |
398 | Supply, storage, installation, testing and comissioning of CE/UL Certified 3 KVA UPS with Batterieswith 02 hrs backup required for mentioned work |
399 | Supply, storage, installation, testing and comissioning of HP or equivalent 600 DPI ink jet colour printer |
400 | Supply, storage, installation, testing and comissioning of HP or equivalent Laser Printer 1018 or equivalent. |
401 | Core i5 10th gen Desktop with 8 gb ram and 1TB SSD |
402 | Core i5 10th gen 15.6 inch laptop with 8 gb ram and 1TB SSD for SCADA presentation and record work |
403 | Supply, storage, installation, testing and comissioning of Security Survelliance IP Camera with recorder |
404 | Installation. Commissioning and testing with required furniture |
405 | Trial & Run for 3 months for electrical - mechanical & SCADA work with Operators,Technician and SCADA Operators |
406 | Sodium Hypochloride for 3 months trial & run |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail