Tender For Re E Tender (3Rd Call) For Procurement Of Some Consumable Items For Two Years From The Date Of Award Of Contract (Aoc)
Tender Overview
Project Description
Wbhf /Hst/ 1P-112-2022/ Con-Rt2(176_212)/2023/235 Re E Tender (3Rd Call) For Procurement Of Some Consumable Items For Two Years From The Date Of Award Of Contract (Aoc) , Advance Vaccum Positioning : Positioner Attachment 360 Degree Articulation With Dynamic Tissue Adherence To The Apex Of The Heart Ensures Stabilization On Beating Heart ; Vaccum Stabilization Minimizes Tissue Trauma. , Advance Vaccum Stabilization: Stabilizer With Ball Attachment , Suction 360 Degree Articulation Maximizes Vessel Access And Stabilization , Malleable Footprint. , Cage Plates Screws For Cervical Fixations , D.J. Stent (Double Pig Tail)- Poly Urethane Made , Non Hydrophilic Coated. Sizes: 5.5Fr/26 Cm (One End Closed), 5.5 Fr/ 26 Cm (Both End Open), 6 Fr/26 Cm (Both End Open), 4 Fr/ 18 Cm (Both End Open), 6 Fr/26 Cm (One End Closed) , Dialyzer High Flux (F60s/Hf80s/Hdf100s) For Hdf Specification : 1. Surface Area-1.3M2 To 1.8M2 2.Blood Priming Volume-80 Ml To 110 Ml. 3. Uf-Co-Efficient-40Ml/Hr/Mmhg To 55Ml/Hr/Mmhg 4. Maximum Tmp-500 Mm/Hg To 600 Mm/Hg 5. Dialyser Membrane-Polysulfone 6. Sterilization Method-Inlineserilization , Dialyzer Single Use For Sero Positive Specification : 1. Surface Area-1.3M2 To 1.6M2 2.Blood Priming Volume-64 Ml To 90 Ml. 3. Uf-Co-Efficient-12Ml/Hrs/Mm Hg To 16Ml/Hrs/Mmhg 4. Maximum Tmp-500 Mm/Hg To 600 Mm/Hg 5. Dialyser Membrane-Polysulfone 6. Sterilization Method-Inline Steam Sterilization , Guide Wire For Intensive Care Unit Data Processing Unit , Intra Venous Cannula (Disposable) (Child) 24/26 G In Peel Off Sterile Packs - Three Way Iso 10555-1 Iso 10555-5 , Miss (Minimally Invasive Spinal Set Kit) , Monitor, Capnometer, (For Monitoring Of Co2 In Breathing Circuit) With Numerical Digital Display & Wave Form. , Nebuliser With Humidifier Having Features For Fixed And Variable Concentration Oxygen Therapy, Aerosol (Humidification) Therapy And Nebulisation Therapy. Face Mask- Properly Fitted Adult Or Pediatric With Nose Clip • Nebulizer Adapter, Allowing Oxygen Concentrations Of 28-98% • 22Mm Connector For Patient Tubing • Aerosol Particle Size Between 1.2 And 8 Microns • Supplied Individually In A Peelable Pouch • Sterile (Eto) Is /Iso/Qms Certified From Nabcb Accreditated Bodies Or Ce/Usfda Certified. , Needle, Suture, Round Body, Half Circle For Using Catgut, 9 Sizes 2,4,6,8,10,12,14,16,18,20 D.B 469/ F Is 9165: 1992 , Needle, Suture, Triangular Cutting 3/8 Circle 9 Sizes: 2,4,6,8,10,12,14,16,18 Is 9165: 1992 , Needle, Suture,Triangular Cutting Halfcircle 15 Sizes: 2,4,6,8,10,12,14,16,18,20,22,24,26,28,30 Is 9165: 1992 , Needles, Suture, Triangular Cutting, Straight 8 Sizes: 2, 4, 6, 8, 10, 12, 14, 16 Is 9165:1992 , Orthopaedic Surgical Pack Specification : 1. Drape Sheet (150 Cm X 150Cm ) (Plain Sheet)-2 2. Extreamly Drape (228 Cm X 330Cm) -1 3. Mayo Table / Instrument Table(150 Cm X 200Cm)-1 4. Cautery Bag (30 Cm X 35Cm)-1 5. Cling Drape (Universal )-1 , Sterilizer, Instrument Sterilizer Made Of Steel, Hot Air, With Automatic Adjustable Temperature Regulator From 120C-200C/ 220-Ac/Dc. Inside Measurement: 600Mm. X 600Mm. X 600 Mm. (2 Ft. X 2 Ft. X 2 Ft.)(Hot Air Sterilizers) Is 3119 , Volume Administration Set, Transfusion Sets For Single Use, For Children With Transparent Plastic Cylinder 50 Ml. Size Graduated At Interval Of 5 Ml. With A Top Narrow Short Tube Outlet. The Needle Will Be Thinner & Suitable For The Purpose. In Sterile Packing Is 9824 : Part 3, Filter Is:4445 , Vp Shunt (Programmable/ Antibiotic Impregnated) , Wax Bath: Large Size. Is 5827 , Wax Bath: Medium Size Is 5827
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Feb-2023 | REVISED TECHNICAL DATA SHEET | Other | 28-Feb-2023 |
| 2 | 15-Feb-2023 | CORRIGENDUM-1 | BOQ | 28-Feb-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Advance Vaccum Positioning : Positioner Attachment 360 degree articulation with dynamic tissue adherence to the apex of the heart ensures stabilization on beating heart ; vaccum stabilization minimizes tissue trauma. |
| 2 | Advance vaccum stabilization: Stabilizer with ball attachment , suction 360 degree articulation maximizes vessel access and stabilization , Malleable footprint. |
| 3 | Cage Plates Screws for Cervical Fixations |
| 4 | D.J. STENT (Double pig tail)- Poly urethane made , Non hydrophilic coated. Sizes: 5.5fr/26 cm (one end closed), 5.5 fr/ 26 cm (both end open), 6 fr/26 cm (both end open), 4 fr/ 18 cm (both end open), 6 fr/26 cm (one end closed) |
| 5 | Dialyzer High Flux (F60S/HF80S/HdF100S) for HDFSpecification : 1. Surface Area-1.3m2 to 1.8m22.Blood Priming Volume-80 ml to 110 ml.3. UF-Co-efficient-40ml/hr/mmHg to 55ml/Hr/mmHg4. Maximum TMP-500 mm/hg TO 600 mm/Hg5. Dialyser Membrane-Polysulfone6. Sterilization Method-InlineSerilization |
| 6 | Dialyzer Single Use for Sero PositiveSpecification :1. Surface Area-1.3m2 to 1.6m22.Blood Priming Volume-64 ml to 90 ml.3. UF-Co-efficient-12ml/hrs/mm Hg to 16ml/Hrs/mmHg4. Maximum TMP-500 mm/hg TO 600 mm/Hg5. Dialyser Membrane-Polysulfone6. Sterilization Method-Inline Steam Sterilization |
| 7 | GUIDE WIRE FOR INTENSIVE CARE UNIT DATA PROCESSING UNIT |
| 8 | INTRA VENOUS CANNULA (DISPOSABLE) (CHILD) 24/26 G IN PEEL OFF STERILE PACKS - THREE WAY ISO 10555-1 ISO 10555-5 |
| 9 | Miss (Minimally Invasive Spinal Set Kit) |
| 10 | MONITOR, CAPNOMETER, (FOR MONITORING OF CO2 IN BREATHING CIRCUIT) WITH NUMERICAL DIGITAL DISPLAY & WAVE FORM. |
| 11 | Nebuliser with HumidifierHaving features for fixed and variable concentration oxygen therapy, aerosol (humidification) therapy and nebulisation therapy.Face mask- properly fitted adult or pediatric with nose clip• Nebulizer adapter, allowing oxygen concentrations of 28-98%• 22mm connector for patient tubing • Aerosol particle size between 1.2 and 8 microns • Supplied individually in a peelable pouch• Sterile (ETO)IS /ISO/QMS certified from NABCB Accreditated bodies or CE/USFDA Certified. |
| 12 | NEEDLE, SUTURE, ROUND BODY, HALF CIRCLE FOR USING CATGUT, 9 SIZES 2,4,6,8,10,12,14,16,18,20 D.B 469/ F IS 9165: 1992 |
| 13 | NEEDLE, SUTURE, TRIANGULAR CUTTING 3/8 CIRCLE 9 SIZES: 2,4,6,8,10,12,14,16,18 IS 9165: 1992 |
| 14 | NEEDLE, SUTURE,TRIANGULAR CUTTING HALFCIRCLE 15 SIZES: 2,4,6,8,10,12,14,16,18,20,22,24,26,28,30 IS 9165: 1992 |
| 15 | NEEDLES, SUTURE, TRIANGULAR CUTTING, STRAIGHT 8 SIZES: 2, 4, 6, 8, 10, 12, 14, 16 IS 9165:1992 |
| 16 | Orthopaedic Surgical PackSpecification :1. Drape Sheet (150 cm x 150cm ) (Plain Sheet)-22. Extreamly Drape (228 cm x 330cm) -13. Mayo Table / Instrument Table(150 cm x 200cm)-14. Cautery bag (30 cm x 35cm)-15. Cling Drape (Universal )-1 |
| 17 | STERILIZER, INSTRUMENT STERILIZER MADE OF STEEL, HOT AIR, WITH AUTOMATIC ADJUSTABLE TEMPERATURE REGULATOR FROM 120C-200C/ 220-AC/DC. INSIDE MEASUREMENT: 600MM. X 600MM. X 600 MM. (2 FT. X 2 FT. X 2 FT.)(Hot Air Sterilizers) IS 3119 |
| 18 | VOLUME ADMINISTRATION SET, TRANSFUSION SETS FOR SINGLE USE, FOR CHILDREN WITH TRANSPARENT PLASTIC CYLINDER 50 ML. SIZE GRADUATED AT INTERVAL OF 5 ML. WITH A TOP NARROW SHORT TUBE OUTLET. THE NEEDLE WILL BE THINNER & SUITABLE FOR THE PURPOSE. IN STERILE PACKING IS 9824 : Part 3, Filter IS:4445 |
| 19 | Vp Shunt (Programmable/ Antibiotic Impregnated) |
| 20 | WAX BATH: LARGE SIZE. IS 5827 |
| 21 | WAX BATH: MEDIUM SIZE IS 5827 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender