Sl. No. | Item Description |
1 | PART-A (Building Work) Based on BSR PWD - 2019, Bikaner |
2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
3 | PCC in foundation :Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
4 | Brick Work masonary with F.P.S bricks of Ist Class Desgnation in Foundation and plinth in. Cement Sand Mortar 1:6 ( 1 Cement :6 Coarse sand) Add extra over item of brick workwith class designation 10.0 in substitutionof class designation 7.5 :Quantity in Cum. |
5 | Plinth Beam:-Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
6 | Dry brick on edge flooring in required pattern with bricks of class designation 75 on bed of 12 mm mud mortar including filling joints with river sand complite . |
7 | HALF BRICK WORK :- Half brik masonary in supperstructure , above plinth level up to floor five level using F.P.S.bricks of designation 75 cement mortar 1:4 (1-cement:4-course sand) |
8 | FLYASH BRICK WORK:- Brick work with mechanised autooclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level up to floor five level in cement mortar 1:6. |
9 | Lintel Beams:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
10 | Slab & Beam:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
11 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
12 | Steel Reinforcement:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire)all complete upto floor five leve TMT bars (Conforming of relevent IS Code). |
13 | Door Frames:-Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.angle iron (40x40x5mm. @ 3 kg/m) |
14 | Doors:-Providing and fixing M.S. sheet 1 mm thickdouble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint. Add extra for double leaf shutters |
15 | Glazed Window:Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%] |
16 | Wire Gauge Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at not exceeding 150 mm distance. |
17 | Guard Bars: P&F square bars or other flat welded to window/ventilators etc. |
18 | kota stone slab flooring 25 mm thick over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 Course sand ) for area 2001 to 5000 sq. Cm |
19 | kota stone slabs 25 mm thick in risers and stepsskirting, dado and pillars laid on 12 mm (average)thick cement mortar 1:3(1 cement: 3 Course sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs , including rubbing and polishing completeFor areaof each slab upto2001 sq. Cm |
20 | TERRAZO TILES OVER ROOF:- Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size up to 6 mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles , including cutting, grinding rubbing with machine complete on 20 mm thick bed of cement sand mortar 1:4. |
21 | Providing & Fixing Ist quality standard White, gray, ivory,fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 and IS: 15622 of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls and piller) |
22 | Internal Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick |
23 | External Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick |
24 | Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand) |
25 | Black Board : Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick |
26 | Grading roof for water proofing treatment withwater proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
27 | Gola:- Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. |
28 | INTERNAL FINISHING:- Distempring with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding new work ( two or more coats ) over and including scrapping and priming coat with cement primer. |
29 | EXTERIOR FINISHING :- Finishing walls with acrylic smooth exterior paint of rquired shade including all scaffolding .New work ( two or more coat applied @ 1.67 /lit/10 sqm. ) |
30 | PUTTY:-Providing and applying white based cement putty over plastered surface to prepare the surface even and smooth complete. |
31 | Painting On Doors, Windows & Ramp Raling :- Painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shadenew steel work (2 or more coat on new work). |
32 | Copping: Cement concrete flooring 1:2:4 (1 cement: 2 Course sand: 4 Greded stone aggregate) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. |
33 | For rain water-P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
34 | For rain water-P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia |
35 | Pipe Clip110 mm dia |
36 | Providing and laying factory made chamfered edge Plastic coated Designer Cement Concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method, to attain superior smooth finish using PU or equivalent moulds, laid in required Grey/Yellow/Red or any other colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge: |
37 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
38 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
39 | Part- C (Sanitary Item) Provinding and fixing3- layer PP-R (Polyproylene random copolymer) pipeS SDR 7.4 UV stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. This includes testing of joint complete as per direction of engineer-incharge.(internal work-exposed on wall)PN-16 Pipe, 25 mm OD |
40 | Provinding and fixing3- layer PP-R (Polyproylene random copolymer) pipeS SDR 7.4 UV stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. This includes testing of joint complete as per direction of engineer-incharge.(internal work-exposed on wall)PN-16 Pipe, 16 mm OD |
41 | P & F squatting pan ( Indian type ) white glaze viterous china 1st quality W.C. pan ( IS: 2556 MARK) with 100 mm viterous chinaP or S trap including cutting & making good the wall & loor (excluding a pair of foot rest ) size 510 mm |
42 | P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make,25 mm G.I. waste pipe complete including cutting & making good the wall.: 450 x 300 mm |
43 | P & F Bib Cock (IS : 8931 Mark) superior quality of approved make.C.P. Brass 400 gm, 15 mm nominal bore. |
44 | P & F Inlet connection (Angle Valves) Superior quality of approved make C.P. Intel connection 15 mmbrass(IS : 8931) |
45 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
46 | P& F waste Coulping with fittings of approved quality /make:C.P. brass 40 mm dia |
47 | P& F waste Pipe with All fittings of approved quality /make: P.V.C. with C.P. Nut 40 mm dia |
48 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia |
49 | Pipe Clip110 mm dia |
50 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Plain floor trap 110 mm dia |
51 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant P-Trap 110 mm dia |
52 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Vent Cowel 110 mm dia |
53 | P & F Ist quality WVC urinal ( IS:2556 mark) with 25mm dia G.I Waste pipe dome couplings, Concealed iron brackets or screws etc. complete. |
54 | S/F RCCmain hole covers with frame of approved make (Light Duty) Size 450x450 mm |
55 | P/F Grating of Approved quality Stainiese Steet sheet size 125 mm dia |
56 | Construction of Soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.inner dia 90 cm & 10 to 12 m deep |
57 | Construction of Chamber in all types of soil with 300 mm thick masnory in CM. 1 : 6, 100 mm thick C.C. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in Cm 1 : 6, finished with floating neat cement 50 mm thick M-15 grade C.C. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 Mtr.Inside size 300 x 300 mm depth upto 0.5 M & 5 Kg CI cover with frame. |
58 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 400 gm, 15 mm |
59 | P & F 15 mm dia connection pipe of approved quality make PVC Pipes with nuts 450 mm. |
60 | P & F Stop cock (IS:8931 Mark),Superior quality and of approved mark: Brass 400 gm. 15 mm nominal bore |
61 | P&F GI Pipes (External Work) with GI fittings excluding union (SI: 1239 Mark) including trenching and refilling each etc. 15 mm dia nominal bore B Class |
62 | P & F PVC Storage Tank ISI Marked ( IS: 12701) indicating the BIS license No. of approved make with cover, 25mm dia 1 M long G.I. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity |
63 | Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make group-2 Light point Short point (up to 3 mtr.) |
64 | Medium point (up to 6 mtr) |
65 | Long point (up to 10 mtr) |
66 | Fan point- Short point (up to 3 mtr.) |
67 | Fan point- Medium point (up to 6 mtr) |
68 | Long point (up to 10 mtr) |
69 | Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces group - On board |
70 | S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. Group-225 mm dia |
71 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. Group-2 (1 x 1.5 sq. mm) |
72 | 2 x 1.5 sq. mm |
73 | 2 x 2.5 sq. mm |
74 | P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. Group-2 6 A to 32 A rating |
75 | P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB termination with copper lux, testing etc. as reqd. . group-2Single door(Single Phase) 8 way |
76 | P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel)complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube)1x36 watts with OCCB. Group-2 |
77 | P & F Fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts |
78 | P/I aying PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:1554 P-I of Groups of approved make in ground as per IS:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, Iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm |
79 | P & F star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated |
80 | P & F IS:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup-2 (E071400) |
81 | P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required |
82 | P & F 18 swg MS Recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp-1 |
83 | P & F 18 SWG Sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmX 100 mmX60 mm |
84 | P & F paper phenolic resin bonded laminates confirming to IS: 2036- 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick |