Tender For Provision Of Works Services For Recycling Of Grey Water At Af Stn Under Ge (Af) Tughlakabad, tughlakabad-Maharashtra

Military Engineer Services-MES has published Tender For Provision Of Works Services For Recycling Of Grey Water At Af Stn Under Ge (Af) Tughlakabad. Submission Date for this Tender is 25-03-2023. Water Treatment Plant Tenders in tughlakabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36094496
Corrigendum : Tender For Provision Of Works Services For Recycling Of Grey Water At Af Stn Under Ge (Af) Tughlakabad
Open Tender
Indian
Maharashtra
tughlakabad
25-03-2023

Tender Details

Tender For Provision Of Works Services For Recycling Of Grey Water At Af Stn Under Ge ( Af ) Tughlakabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Feb-2023 Corrigendum1 Date 06-03-2023
2 27-Feb-2023 Corrigendum2 BOQ 06-03-2023
3 06-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2023
4 13-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-03-2023
5 18-Mar-2023 Date Extended 18Mar2023 Admin Corrigendum Date Extend 20-03-2023
6 22-Mar-2023 Corrigendum3 Date 25-03-2023
7 22-Mar-2023 Corridendum4 Other 25-03-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 100300.0 /-
Tender Value
INR 50.18 Lakhs /-

BOQ Items

Name of Work: PROVN OF WORKS SERVICES FOR RECYCLING OF GREY WATER AT AF STNUNDER GE (AF) TUGHLAKABAD
Sl. No. Item Description
1Sch "A" Part-I Sewage Disposal
2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply with CPVC Schedule 80 pipes & plain CPVC Schedule 80 fittings including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as specified and directed for 80 mm Nominal dia pipes in trenches or in wall per direction of Engineer in Charge. Note: 1) Yellow solvent/adhesive used for CPVC joining is deemed to be included in quoted rates. 2) All the CPVC plain Fittings required at site is deemed to be included in quoted rates.
3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supplywith Pipes SDR 11 & Plain CPVC SDR 11 fittings including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as specified and directed for 50 mm Nominal dia pipes in trenches or in wall per direction of Engineer in Charge. Note: 1) Yellow solvent/adhesive used for CPVC joining is deemed to be included in quoted rates. 2) All the CPVC plain Fittings required at site is deemed to be included in quoted rates. 3) Rate of clamps, T&P required at site and labour for clamping CPVC pipe on 15Mtrs high bldg is deemed to be included in quoted rates.
4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply with Pipes SDR 11 & Plain CPVC SDR 11 fittings including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as specified and directed for 40 mm Nominal dia pipes in trenches or in wall per direction of Engineer in Charge. Note: 1) Yellow solvent/adhesive used for CPVC joining is deemed to be included in quoted rates. 2) All the CPVC plain Fittings required at site is deemed to be included in quoted rates. 3) Rate of clamps, T&P required at site and labour for clamping CPVC pipe on 15Mtrs high bldg is deemed to be included in quoted rates.
5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply with Pipes SDR 11 & Plain CPVC SDR 11 fittings including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as specified and directed for 25 mm Nominal dia pipes in trenches or in wall per direction of Engineer in Charge. Note: 1) Yellow solvent/adhesive used for CPVC joining is deemed to be included in quoted rates. 2) All the CPVC plain Fittings required at site is deemed to be included in quoted rates. 3) Rate of clamps, T&P required at site and labour for clamping CPVC pipe on 15Mtrs high bldg is deemed to be included in quoted rates.
6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply with CPVC Schedule 80 pipes & plain CPVC Schedule 80 fittings including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as specified and directed for 100 mm Nominal dia pipes in trenches or in wall per direction of Engineer in Charge. Note: 1) Yellow solvent/adhesive used for CPVC joining is deemed to be included in quoted rates. 2) All the CPVC plain Fittings required at site is deemed to be included in quoted rates.
7NOTE :- The contractor shall submit leakage test report of Pipe and Joints duly signed by the Engr-in-Charge for complete payment of Item no. 2.00 to 6.00.
8Supplying, fitting and fixing of CPVC Ball Valve of80mm dia, conforming to IS-15778 : 2007 of approved make / brand, complete all as specified and directed.
9Supplying, fitting and fixing of CPVC Ball Valve of50mm dia, conforming to IS-15778 : 2007 of approved make / brand, complete all as specified and directed.
10Supplying, fitting and fixing of CPVC Ball Valve of40mm dia, conforming to IS-15778 : 2007 of approved make / brand, complete all as specified and directed.
11Supplying, fitting and fixing of CPVC Ball Valve of25mm dia, conforming to IS-15778 : 2007 of approved make / brand, complete all as specified and directed.
12M&L forconstruction of new valve pit of size 90cm x 90cm x 90cm ( internal dimension) including necessary excavation, earth work , 150 mm thick PCC 1:4:8 type D-2 as in foundation, brick work in CM 1:4, 12 mm thick internalplastering in cement mortar 1:4 , 100 mm thick internal PCC 1:2:4, type BI in coping including MS cover fabricated out of 3 mm thick MS sheet and angle iron frame of size 40x40x6mm and locking arrangement including painting with two coats of synthetic enameled paintingover a coat of red oxide primer after preparation of surface complete all as specified and directed by Engr-in-Charge.
13Supply, install, connecting, testing and commissioning elctric driven monoblock centrifugal pumpset of CI body with bronze impeller operating at 2800 RPM capable of discharge of 4.0 Ltrs per Sec at a head of 45mtrs 3 Phase, copper wounded class "B" insulation, IP-44, for evacuating rain water mounted on a common MS fabricated platform including stater, PCC foundation & grounting foundation bolts for fixing MS channel, complete all as specified & directed. Note: 1) Foundation required as per OEM & Rain shed for pumpset is included in rates quoted. 2) 3 phase DOL starter suitable for pumpset & connected work is deemed to be included quoted rates. 3) Fittings & pipe required of any size & qty as per OEM specification for making header of pumpset is deemed to included in quoted rates. 4)Making hole in RCC wall for suction of motor as per foundation is deemed to be included in rates quoted.
14Supply & laying on wall/floor, PVC insulated and PR PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volts, confirming to IS 694 of size 16Sqmm, 3 core, complete all as specified & directed.
15Supply and fix CI Foot Valve Flanged end swing type operation with rubber seat having single disc, conforming to IS 4038 of size100 mm (4”) dia, complete all as specified & directed.
16Supply and fix globe valve screwed type of size 100mm dia, complete all as specified and directed.
17Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
18Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
19Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
20Supplying and fixing CPVC fittings of 100mm inner dia confirming to CPVC schdule 80 as mentioned below:
21Union 100mm inner dia
22End cap 100mm inner dia
23Male Brass Threaded Adaptor (MTA/ MBTA) ) 100mm inner dia
24Female Brass Threaded Adaptor (FTA/ FBTA)75mm inner dia
25Supplying and fixing CPVC fittings of 75mm inner dia confirming to CPVC schdule 80 as mentioned below:
26Union 75mm inner dia
27End cap 75mm inner dia
28Male Brass Threaded Adaptor (MTA/ MBTA) ) 75mm inner dia
29Female Brass Threaded Adaptor (FTA/ FBTA)75mm inner dia
30Supplying and fixing CPVC fittings of 50mm inner dia confirming to CPVC SDR 11 as mentioned below:
31Union 50mm outer dia
32Male Brass Threaded Adaptor (MTA/ MBTA) ) 50mm outer dia
33Female Brass Threaded Adaptor (FTA/ FBTA)50mm outer dia
34Supplying and fixing CPVC fittings of 40mm inner dia confirming to CPVC SDR 11 as mentioned below:
35Union 40mm outer dia
36Male Brass Threaded Adaptor (MTA/ MBTA) ) 40mm outer dia
37Female Brass Threaded Adaptor (FTA/ FBTA)40mm outer dia
38Supply and fixing PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 16 Sqmm 3 core, 1100 Volt, conforming to IS 694, complete all as specified and directed.
39M&L for road cutting upto 400mm deep including making good the disturbed surface by filling mass concrete of 20mm thick complete all as specified and directed.
40M&L for cement concrete in foundation filling, pole coping and mass concrete of type D2 1:4:8 (40mm graded aggregate), complete all as specified and directed.
41Supply and fixing of Multi grade sand media filter FRP vessel of size 1200mm approx dia and height of of 1800mm approx having vertically mounted multiport valve, suitable for flow rate of 14000-16000 Ltrs/hr, of capacity of 1600Ltrs including multigrade media not less than 900kg & other specifications as per specified by OEM. Note: 1) Foundation required as per OEM is included in rates quoted. 2) Alternate Layers of media of varioussize, thicks etc should be done in supervion of OEM 3) Multiport valve of suitable size is deemed to be included in quoted rate.
42Supply and fixing of Activated carbon media filter FRP vessel of size 1200mm approx dia and height of of 1800mm approx having vertically mounted multiport valve, suitable for flow rate of 14000-16000 Ltrs/hr, of capacity of 1600Ltrs including multigrade media not less than 900kg & other specifications as per specified by OEM. Note: 1) Foundation required as per OEM is included in rates quoted. 2) Alternate Layers of media of varioussize, thicks etc should be done in supervion of OEM 3) Activated Carbon used should be of IV 600 Grade. Contractor has to submit certifacte from OEM for it genuinity. 4) Multiport valve of suitable size is deemed to be included in quoted rate.
43Supply, install, connecting, testing and commissioning elctric driven Filter Feed pump of having head of 6-12mtrs, discharge 34-22 LPS, 3 pahse, C/s area of 100mm for suction & discharge, copper wounded class "B" insulation, IP-44, complete all as specified by OEM. Note: 1)Foundation required as per OEM & Rain shed for pumpset is included in rates quoted. 2) 3 Phase DOL starter suitable for pumpset & connected work is deemed to be included quoted rates. 3) Fittings & pipe required of any size & qty as per OEM specification for making header of pumpset is deemed to included in quoted rates.
44M&L for plumbing work required connection of Filter feed pump to Sand media filter, Carbon Activated media filter and outlet to storage tank with 100mm UPVC pipe including fittings & 100mm valves as specified by OEM.
45Supply only Bio culture solution to enhance growth of bacteria in MMBR as specified by OEM
46M&L for dismantling and taking down old u/s MS Cylinder of sand media filter & activated carbon media filter of 1100mm & 900mm dia along with connected pipe work and butterfly valve and removing it from site/clearing site for installation of new tanks, complete all as specified and directed.
47Sch "A" Part-I Bldg Works
48S & F in repair PVC low level flushing cistern of 10 ltrs capacity with top push button inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make.
49M& L for cutting holes, square or circular n exc. 0.1 sq. m in any of the foregoing boards,sheets or tiles including brick work in any thickness all as specified and as directed by Engr in Charge.
50S & F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality.
51S & F in repair 15 mm bore Angle stop valve cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed all as specified
52S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
53S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
54M&L for brick work built in cement and sand mortar 1:6 with sub class "B" old size bricks straight or curved on plan exceeding 6 m means radius complete all as specified.
55M&L rendering 15 mm thick in cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smoothe without using extra cement.
56S&F 1000 ltrs three layer in white colour capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
57S&Fgun metal gate valves with iron wheel head 20mm bore complete all as specified.
58M&L for 100 mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) as in sub base under interlocking tiles/chequred tile etc complete all as specified.
59M&L for 75 mm thick PCC 1:3:6, type C-2 (40mm graded aggregate) as in sub base under interlocking tiles/chequred tile etc complete all as specified.
60M&L chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors including 20 mm screed bed in CM 1:6complete all as specified.
61Supply only integral water proofing compound ISI marked
62M&L for applying APP modified membrane (minimum 3 mmthick), it shall be taken upto height of minimum 300mmthrough a fillet or 75mmx75mm and shall be inserted inside a groove cut in the parapet and fixed. If the height of parapet is 300mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface to the parapet. For RCC inverted beam the whole beam shall be covered with membrane irrespective of the depth. In case of roof projection, the membrane shall be taken 50mm on the reverse side of roof at the edges.with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 100mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
63Supply & fixingfor framed work such as grills, gratings,tank cover, drain covers made of MS Angle, Channel, Bars and sheets etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 complete all as specified and directed by the Engineer-in-Charge.
64S&F welded steel wire fabric n exc 4 Kg/ Sqm welded to steel section at any position complete.
65M&L for preparation of new steel surfaces exc 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
66Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail